• Title/Summary/Keyword: 프리캐스트 콘크리트 판구조

Search Result 54, Processing Time 0.025 seconds

Applicability Evaluation of Precast Deck to the Maglev Guideway System : Static Performance Test (프리캐스트 바닥판의 자기부상열차 가이드웨이 시스템 적용성 평가 : 정적 성능 실험)

  • Jin, Byeong-Moo;Kim, In-Gyu;Kim, Young-Jin;Lee, Yun-Seok;Ma, Hyang-Wook;Oh, Hyun-Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.985-988
    • /
    • 2008
  • Maglev is a system that a train runs levitated above a rail. Therefore it is very important to maintain a constant levitation gap for achieving serviceability and ride comfort. This study is a cooperation research subject of the 3-1 subject, performance improvement of maglev track structures, of the Center for Urban Maglev Program in Korea, started in 2006. The aim of this study is development of rapid constructions of bridge superstructure for maglev. At present, precast deck is widely used because of its superiority to cast-in-place concrete on quality and the term of works. The research group suggested basic systems of maglev guideway with PSC-U type and trapezoidal open steel box type girder, and precast deck, cooperating with Korea Railroad Research Institute, the managing institute of the 3-1 subject. In this study, full-scale structure was fabricated for structural safety evaluation of precast decks and rail, and a static performance test of those structures was performed.

  • PDF

Fatigue Performance of Bridge Decks using Half-Depth Precast Panel with Loop Joint (루프이음 반단면 프리캐스트 패널을 이용한 교량 바닥판의 피로성능)

  • Chung, Chul Hun;Lim, Seung Jun;Kim, Hyun Jun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1A
    • /
    • pp.35-43
    • /
    • 2010
  • The panels are used as a composite part of the completed deck. They replace the main bottom transverse deck reinforcement and also serve as a form surface for the cast-in-place concrete upper layer that contains the top of deck reinforcement. However, in order to apply the precast panels to bridges properly, it is necessary to fully understand the structural characteristics of joint in precast panels. Particularly, since the bridge deck is under repeated loads such as traffic loads, fatigue behavior and characteristics of joint should be investigated. In this paper, fatigue tests of composite deck with shear ties and loop joints were conducted. The fatigue tests were conducted with an application of repeated loading and wheel loading. Test results were analyzed to examine the current design code for fatigue of reinforcement bar and serviceability under repeated loading.

Strength of PSC Bridge Decks using Half-Depth Precast Panel with Loop Joint (루프이음 반단면 프리캐스트 패널을 이용한 PSC 바닥판의 강도평가)

  • Chung, Chul Hun;Kim, Yu Seok;Hyun, Byung Hak;Kim, In Gyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.433-445
    • /
    • 2009
  • The panels are used as a composite part of the completed deck. They replace the main bottom transverse deck reinforcement and also serve as a form surface for the cast-in-place concrete upper layer that contains the top of deck reinforcement. Research has also demonstrated that mechanical shear ties on the top of the panels are required. In a composite deck with precast panels, it is required to notice behavior of transverse joints between panels. In this paper, static tests of composite deck with shear ties and loop joints were conducted. From the results, the validity of loop joints for continuity of deck was observed. Also, a composite behavior was abserved between precast panel and slab concrete. Tested composite decks with shear ties have 140~164% ultimate strength than have no shear ties due to the increase of composite action. Therefore, the shear ties between the slabs were sufficient to enforce composite flexural behavior to failure.

Analytical Modeling of Precast Concrete Large Panel Structures Taking Account of Stiffness of Vertical Joints (수직접합부 강성을 고려한 프리캐스트 콘크리트 대형판구조물의 해석모델)

  • 이한선;장극관;신영식
    • Computational Structural Engineering
    • /
    • v.7 no.3
    • /
    • pp.105-113
    • /
    • 1994
  • Precast concrete(P.C.) large panel structures have usually weaker stiffness at joints than that of monolithic in-situ reinforced concrete structures. But structural designers do not in general take into account this characteristics of P.C. large panel structures and use the same analytical models as for the monolithic structure. Therefore, the results of analysis obtained by using these models may be quite different from those actually occurring in real P.C. structure. In this study, the change in force and stress distribution and deflections of structure caused by applying lower shear stiffness at vertical joints are investigated through trying several finite element modeling schemes specific for P.C. structures, Finally, for engineers in practice, a simplified model, which takes account of the effect of lower shear stiffness at vertical joints, is proposed with the understanding on possible amount of errors.

  • PDF

Evaluation on Structural Performance of Precast Bridge Deck Joint using HSFRC (고강도 강섬유보강콘크리트를 적용한 프리캐스트 바닥판 이음부의 구조성능 평가)

  • Lee, Han-Joo;Chung, Chul-Hun;Shin, Dong-Ho;Park, Se-Jin;Kim, In-Gyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.196-205
    • /
    • 2017
  • In precast deck system, structural performance and serviceability are mostly determined by the connection methods between the precast decks. This study proposes precast deck system with asymmetric ribbed connection details using High Strength Fiber Reinforced Concrete(HSFRC) with filler. To verify the proposed method, the flexural performance experiment was carried out with variation of joint cross section type and splice rebar details. From the test results, regardless of joint details, spliced tensile rebars of specimens were deformed to yielding strain level. Also, all types of specimens resulted in sufficient flexural performance. These test results show that the minimum lap splice length specified in current Korea Highway Bridge Design Code is conservative for precast deck joint using HSFRC. Therefore, splice details can be simplified and joint width can be reduced by using HSFRC with filler between the precast decks, and the proposed precast deck systems can be applied to the connection part of precast decks effectively.

Crack Width Control on Concrete Slab using Half-Depth Precast Panels with Loop Joints (루프이음 반두께 프리캐스트 바닥판을 갖는 콘크리트 바닥판의 균열폭 제어)

  • Kim, Dong Wook;Shim, Chang Su
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.1
    • /
    • pp.19-29
    • /
    • 2015
  • As the half-depth precast concrete decks are increasingly applied to the construction sites, researches on connection details have been increased. For design of concrete bridge deck with half-depth precast panels, it is required to provide appropriate details of transverse loop joints between panels. In this paper, the structural performance of precast decks was evaluated to investigate continuity of the proposed loop joint details. From the results, the validity of the joints for the continuity of deck was observed in the aspect of flexural strength and crack control. The ultimate strength increased 1.52 times as the reinforcement spacing in the joint was reduced. In terms of crack control, direct crack width calculation for the loop joint showed appropriate results comparing with measured crack width.

Shaking Table Tests of 1/3-Scale 3-Story Wet-Jointed Precast Concrete Large Panel Box Model (1/3축소 3층 습식접합 프리캐스트 콘크리트 대형판 입체모델의 진동대 실험)

  • 이한선
    • Magazine of the Korea Concrete Institute
    • /
    • v.5 no.1
    • /
    • pp.115-127
    • /
    • 1993
  • 본 연구의 목적은 프리캐스트 콘크리트(P.C) 대형판 아파트 구조물에 대한 우리나라 내진설계기준안 및 지침을 수립하기 위해 필요로 하는 정보를 취득하는데 있다. 이것은 실제 지진과 유사한 진동을 발생시키는 진동대를 사용하여 P.C대형판 구조물의 거동을 분석관찰함으로써 달성되었다. 여기에 사용된 시험체중의 하나는 습식접합 1/3 축소 3층 입체 P.C모델이었다. 지진파를 일으키기 위해 4mx4m 크기의 진동대가 사용되었다. 또한 선택한 입력지진가속도파는 Taft N21E 성분기록지진파로서 최대지진가속도(PGA)는 원하는 지진세기수준에 따라 조정되었고 시간축으로는 동적상사성법칙에 따라 축소되었다. 이 P.C모델의 진동대 실험을 통해 얻은 결과를 근거로 하여, 근거로 하여 다음과 같은 결론을 도출하였다. (1)이 시험체에 관한한, 지진안전계수는 7-8정도로 나타났으며, (2)이 P.C모델이 감쇠계수는 대체로, 철근콘크리트구조물 감쇠계수의 두배에 해당하는 값인 8%정도이며, (3) 이 모델은 접합부의 벌어짐과 미끄러짐에 의한 에너지소산을 통해서 2-3정도의 전체적인 변위연성비를 보여주었다.

FE Analysis on Maglev Guiderail Connection System (자기부상열차 가이드레일 연결시스템의 유한요소 해석)

  • Jin, Byeong-Moo;Lee, Yun-Seok;Kim, In-Gyu;Kim, Young-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.203-204
    • /
    • 2009
  • The maglev guiderail systems, which receive directly the live load of maglev train and transfer the load to the main girder, is a important constituent in guideway system. As a process of development of maglev guideway girder adopting the precast decks, static and fatigue loading tests of the connections systems of precast deck and guiderail have been accomplished. In this stude, the structural characteristics of precast deck-guiderail connection systems are being evaluated by performing a detailed finite element analyses.

  • PDF

A Study on the Similitude of Precast Concrete Panel Structure Using one-third Scale Subassemblage Model (1/3 축적 모형실험에 의한 프리캐스트 콘크리트 판구조의 상사성에 관한 연구)

  • 윤재진
    • Magazine of the Korea Concrete Institute
    • /
    • v.4 no.3
    • /
    • pp.123-134
    • /
    • 1992
  • 본연구는 실물크기의 프리캐스트 콘크리트 판구조물의 부분구조체를 모형화하여 실험한 결과를 분석한 것이다. 구조물의 역학적 특성과 파괴성상을 파악하기 위한 구조실험은 실물크기의 구조물과 부재로써 실시하는 것이 가장 좋은 방법이지만, 이것은 치수가 크므로 공간적으로 제한을 받고 많은 시간과 비용을 필요로 하기 때문에 모형실험을 이용하게 된다. 이러한 모형실험을 최소한의 오차범위내에서 원형실험과 같은 재현하고 예측하도록 실험을 준비하는 데에는 상사법칙이 필요하게 된다. 모형은 무엇보다도 원형과의 응력-변형도 관계 등 구성재료에 대한 상사요구조건을 만족시키는 것이 중요하지만, 본 연구의 대상은 1/3축척으로써 기하학적인 요소와 사용재료에 대한 강도의 상사성만을 고려한 모형이다. 본 연구에서는 이러한 모형구조물의 거동을 원형실험결과와 비교하여 상사성 확보의 문제와 가능성을 조사하였다.

A Experimental Comparison Study on Structural Behavior of Prefabricated Bridge (조립식 바닥판 교량의 거동에 대한 실험적 비교 연구)

  • Han, Man-Yup;Kim, Seong-Dong;Jin, Kyung-Seok;Kang, Sang-Hun;Cho, Byung-Ku
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.25-28
    • /
    • 2008
  • Currently, the prefabricated bridge having the effects to reduce the term of works and the cost of construction is often studied and countries such as America have already developed members, the parts of it, and the technique of construction. In addition, they have supplied them to the fields. The study of prefabricated method of steel composite bridge, which has the precast deck - plate and main girder fixed by high tension bolt and can resist horizontal sheer, is being progressed. However, it is difficult to understand the characteristics of the prefabricated bridge's behavior when the superstructure of the prefabricated method is analyzed by applying to the analysis model of existing bridges. Therefore, this study has the purpose of understanding real structural behavior of prefabricated bridge through comparison and analysis between the structural analysis model reflecting the characteristics of the real prefabricated bridge's superstructure and real size experiment.

  • PDF