• Title/Summary/Keyword: 프리스트레스 강선

Search Result 24, Processing Time 0.021 seconds

Numerical Study on Wire Strength Under Both Tension and Deflection for Use as Prestressing Steel (인장과 휨을 동시에 받는 프리스트레스 강선의 굴절인장성능 평가)

  • Kim, Jin-Kook;Seong, Taek-Ryong;Yang, Jun-Mo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.1
    • /
    • pp.147-153
    • /
    • 2019
  • The prestressing steel wire, which is applied a tension to reinforce the structure, is applied flexure simultaneously by the duct and the deviator. In order to evaluate the deflected tensile performance of the prestressing steel wire subjected to both tensile and flexural stresses, the numerical analysis for 600 cases with variables of wire diameters, mandrel diameters, and friction coefficient between mandrel and steel wire was performed. As the result of analysis, the larger the diameter of the steel wire was, the lower the deflected tensile performance was, and the effect decreased with the increase of the wire elongation. The effect of mandrel diameter and friction coefficient between mandrel and wire on the deflected tensile performance of the wire was very small. But the deflected tensile performance and the friction coefficient between mandrel and strand showed a relatively high correlation. Therefore, it is necessary to make enough large elongation to secure the deflected tensile performance. If there is a restriction on the elongation, it is necessary to reduce the diameter of the steel wire to an appropriate value, and to increase the friction between steel wires by adjusting the surface condition of the steel wire.

A Study on Strengthening of Reinforced Concrete Pier Caps Using Prestressed Near Surface Mounted CFRP (프리스트레스가 도입된 표면매립 CFRP를 이용한 교각 두부 보강에 관한 연구)

  • Hong, Sung-Nam;Kim, Tae-Wan;Park, Sun-Kyu;Park, Jong-Sup;Park, Young-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.5
    • /
    • pp.595-602
    • /
    • 2007
  • Recently, concrete structures with carbon fiber reinforced polymer (CFRP) reinforcements have been commonly used for the bridge and building construction. In this paper, pier caps were strengthened by prestressed near surface mounted CFRP. To verify the effectiveness of the strengthening method, 7 pier cap specimens were fabricated. One specimen was designed for control, two for external prestressing steel strands, two for CFRP plates, and two for CFRP bars. Experimental variables consist of type of reinforcement materials and prestressing levels. The results of laboratory have shown that the ultimate load capacities of prestressed near surface mounted CFRP specimens were about $20{\sim}33%$ greater than that of a control specimen. Also, ultimate load capacities of prestressed near surface mounted CFRP specimens were similar to those of external prestressing specimens with steel strands.

Finite Element Analysis of Earth Retention System with Prestressed Wales (프리스트레스트 띠장을 적용한 흙막이 시스템의 유한요소해석)

  • Park, Jong-Sik;Kim, Sung-Kyu;Joo, Yong-Sun;Kim, Nak-Kyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.3
    • /
    • pp.25-34
    • /
    • 2008
  • A finite element analysis was performed for new earth retention system with prestressed wales. A 3D finite element model was adopted in this study to investigate the behavior of the earth retention system with prestressed wales. A procedure of the 3D finite element modeling of this earth retention system was presented. The procedure included the modeling of soil, wall, strut, and members of prestressed wale system which consists of wale, support leg, and steel wires, and the interface modeling of soil-wall and wall-wale. The numerical predictions of lateral wall deflection, and axial load on the members of prestressed wale systems and struts were evaluated in comparison with the measurements obtained from field instruments. A sensitivity analysis was performed using the proposed 3D finite element model to investigate the behavior of new earth retention system on a wide range of prestress load conditions of steel wires. The lateral deflection of the wall and wale, the bending moment of the wale, and the lateral earth pressure distribution on the wall were computed. Implications of the results from this study were discussed.

Experimental Verification of Age-adjusted Effective Modulus Method to Long-Term Behavior Estimation of Prestressed Composite Girders (재령보정 유효계수방법에 의한 프리스트레스트 합성거더의 장기거동 실험 검증)

  • Bae, Doo-Byong;Oh, Chang-Kook;Choi, Sok-Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.5
    • /
    • pp.571-582
    • /
    • 2012
  • Prestressed composite girders provide efficient composite action by applying prestress to the sub-encasing concrete. In this study, an enhanced prestressed composite girder with forms suspended from the steel girder is utilized. Long-term behavior of the prestressed composite girder is estimated using age-adjusted effective modulus method, which is verified experimentally using measurements obtained from an in-service bridge. Then, parametric study is carried out to investigate the influences caused by ambient temperature, humidity, prestressing and concrete casting date.

A study on Development of Methods to Rehabilitate the Damaged Prestressed Concrete beam Using Glass Fiber (유리섬유를 이용한 손상된 프리스트레스트 콘크리트 보의 보강공법 개발연구)

  • Kang, Won-Ho;Han, Man-Yop;Lee, Taek-Sung;Rhu, Young-Min
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.167-175
    • /
    • 1999
  • Many composite girder bridges have been constructed for about thirty five years. Nowadays they are aged or deteriorated because of the increase in traffic and vehicle loads. In this study, the effect of strengthening with glass fiber sheet is investigated to estimate the possibility for applying to damaged prestressed concrete bridges. One normal and eight cracked specimens which had been preloaded were tested. The cracked specimens were strengthened with either external prestressing or bonding glass fiber sheet, or using both methods. The results showed that the maximum loads are almost same for both methods. So it seems that the strengthening with glass fiber sheet can be used for strengthening damaged prestressed concrete girders. It is important that proper devices should be selected to prevent glass fiber sheet from premature bonding failure below its maximum load, which is similar to end anchorage problem in external prestressing method. It is proved that the devices proposed in this paper have sufficient anchoring capability to increase load carrying capacity.

Detection of Fracture Signals of Low Prestressed Steel Wires in a 10 m PSC Beam by Continuous Acoustic Monitoring Techniques (연속음향감지기법을 이용한 긴장력이 감소된 10 m PSC보의 PS 강선 파단음파 감지)

  • Youn, Seok-Goo;Lee, Chang-No
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.1
    • /
    • pp.113-122
    • /
    • 2010
  • Corrosion of prestressing tendons and wire fractures in grouted post-tensioned prestressed concrete bridges have been considered as a serious safety problem. In bridge evaluation the condition of prestressing tendons should be inspected, and if corroded tendons are found, the loss of tendon area should be included when we calculate the ultimate strength. In the previous study, it was evaluated that continuous acoustic monitoring techniques could be considered as a reliable non-destructive method for detecting wire fractures of fully grouted post-tensioned prestressing tendons. In the present study, an experimental test was performed for detecting wire fractures of post-tensioned prestressing tendons which are prestressed lower than current design level. A 10 m prestressed concrete beam was fabricated, which included two tendons prestressed 66 percentage and 40 percentage of tensile strength, respectively. The corrosion of two tendons was induced by an accelerated corrosion equipment and the test beam was monitored by using seven acoustic sensors and a continuous acoustic monitoring system. From each prestressing tendon, two acoustic signals of wire fractures were successfully detected and source locations were estimated within 20 mm error. Based on the test results, it is considered that continuous acoustic monitoring techniques can be applied to detect low-prestressed wire fracture in fully grouted post-tensioned prestressed concrete beams.

A Study on the Prediction of Ultimate Stress of Tendon in Unbonded Prestressed Concrete Beams without Slip (비부착 PSC 보에서 슬립이 없는 강선의 극한 응력 예측에 관한 연구)

  • Hong, Sung-Su;Yoo, Sung-Won;Park, Seung-Bum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4A
    • /
    • pp.537-548
    • /
    • 2008
  • Recently, the prestressed unbonded concrete structures are increasingly being built. The mechanical behavior of prestressed concrete beams with unbonded tendon is different from that of normal bonded PSC beams in that the increment of tendon stress was derived by whole member behavior. The purpose of the present paper is therefore to evaluate the flexural behavior and to propose the equation of ultimate tendon stress by performing static flexural test according to span/depth, concrete compression strength, reinforcement ratio and the effect of existing bonded tendon. From experimental results, for cracking, yielding and ultimate load, the effect of reinforcement ratio was more effective than concrete compression strength, and the beams having high strength concrete had a good performance than having low concrete, but there was no difference between high strength and low strength. And as L/dp was larger, test beams had a long region of ductility. This means that unbonded tendon has a large contribution after reinforcement yielding. Especially, the equation of ACI-318 was not match with test results and had no correlations. After analysis of test results, the equation of ultimate unbonded tendon stress without slip was proposed, and the proposed equation was well matched with test results. So the proposed equation in this paper will be a effective basis for the evaluation of unbonded tendons without slip, analysis and design.

Experiment of Flexural Behavior of Prestressed Concrete Beams with External Tendons according to Tendon Area and Tendon Force (강선량 및 긴장력에 따른 외부 강선을 가진 PSC 보의 휨거동 실험)

  • Yoo, Sung-Won;Yang, In-Hwan;Suh, Jeong-In
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.4
    • /
    • pp.513-521
    • /
    • 2009
  • Recently, the externally prestressed unbonded concrete structures are increasingly being built. The mechanical behavior of prestressed concrete beams with external unbonded tendon is different from that of normal bonded PSC beams in that the slip of tendons at deviators and the change of tendon eccentricity occurs as external loads are applied in external unbonded PSC beams. The purpose of the present paper is therefore to evaluate the flexural behavior by performing static flexural test according to tendon area and tendon force. From experimental results, before flexural cracking, there was no difference between external members and bonded members. However, after cracking, yielding load of reinforcement, ultimate load, and the tendon stress of external members was lower than that of bonded members. For the relationship of load-tendon stress, the increasing of tendon strain was inversely proportional to the initial tendon force. However, even if the initial tendon force was large, the tendon strain with small effective stress was smaller than that with large effective stress. The concrete compressive strain was proportional to the effective stress of external tendon. From the comparison between test results and codes, the ACI-318 could not consider the effect of tendon force or effective stress, and especially the results of ACI-318 were very small, so it was very conservative. And the AASHTO 1994 could be influenced on the tendon area, initial force and effective stress, but as it was made on the basis of internal unbonded tendon, its results were much larger than the test results. For this reason, the new correct predict equation of external tendon stress will be needed.

Investigation of Stress Changes in Concrete and Strands according to Cutting Order of the Strands in Pre-tensioned Concrete Slab (프리텐션 슬래브 구조에서 긴장강선 용접절단순서에 따른 긴장재 및 콘크리트의 응력변화 고찰)

  • Moon, Do-Young;Kim, Jang-Ho;Kim, Gyu-Seon;Yun, Man-Geun;Zi, Goang-Seup
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.4
    • /
    • pp.419-429
    • /
    • 2009
  • This study focuses on the effect of the cutting order of prestressing strands on the strain change in the strands and on the state of stress of concrete, experimentally and numerically. In the experiment, strain of strands and of transversal reinforcement were measured for three different cutting orders during detensioning process by using flame-cutting procedure. The experimental results were compared with those obtained from the FE analysis. As a results of the experiment, it is confirmed that the cutting order of prestressing strands affected on the strain of strands as well as of transversal reinforcement. The FE analysis gave similar results to those obtained from the experiment. Therefore, the cutting order should be chosen appropriately to when the strands get detensioned.

Current Status and Analysis of PSC Bridge in Korea (국내 프리스트레스트 콘크리트 교량 현황조사 및 분석)

  • Son, Hyeok-Soo;Oh, Myung-Seok;Yoon, Cheol-Kyun;Kim, Ik-Su;Kim, Jin-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.23-24
    • /
    • 2010
  • In this research, the comparison and analysis of domestic prestressed concrete bridges were performed with major variations of superstructure type, and span lengths using the 'current status of roadbridge and tunnel' informations provided by MLTM and STATISTICS KOREA. As a result of analysis, steel box girder bridges with 50~100m span length represent about 76% of bridges, but prestressed concrete bridges represent a relatively smaller percentage. In order to replace steel box girder bridges with prestressed concrete bridges, it is necessary to develop prestressed concrete bridges with high-strength tendons and concrete.

  • PDF