• Title/Summary/Keyword: 풍력-디젤

Search Result 42, Processing Time 0.026 seconds

Modeling of Hybrid Generation System with Wind Turbine and Diesel Generator (풍력-디젤 하이브리드 발전시스템 모델링에 관한 연구)

  • Kim, Jae-Eon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1806-1813
    • /
    • 2012
  • This paper proposes a modeling method for hybrid generation system with wind turbine and diesel generator applicable in island area. For modeling objects, squirrel-cage induction generator is considered as wind turbine generator and synchronous generator as diesel generator. Parameters and controllers related to them are established and modeled through analysis of traditional small capacity class. The simulation results for practical size hybrid generation system were suggested.

An Economic Feasibility Study of Wind-Diesel Hybrid Power Systems for an Island in the Yellow Sea (서해 도서지역의 풍력-디젤 하이브리드 발전에 대한 경제성 분석)

  • Lee, Tak-Kee;Nam, Yong-Yun;Kim, Jae-Dong;Han, Jeong-Woo
    • Journal of Navigation and Port Research
    • /
    • v.35 no.5
    • /
    • pp.381-385
    • /
    • 2011
  • In this paper, an economic feasibility study of wind-diesel hybrid power systems for an island in the Yellow Sea, where the maximum power generation is about 500kW, was performed. For the study, annual electric load variation and wind resource data of the island were collected and analyzed. HOMER program - a typical hybrid optimization model for electric renewables including wind resource, developed by the National Renewable Energy Laboratory - was used. Wind speed and diesel price were picked out as variables for the sensitivity analysis in order to find the economic accountability for the wind-diesel hybrid power system. As the result, even though it is not feasible economically under the present condition, if mean wind speed is over 3 m/sec. or diesel price goes up to 2.4 $ per liter, the wind-diesel hybrid power system for the island becomes a prospective candidate.

풍력발전

  • 전홍석;박경호
    • 전기의세계
    • /
    • v.41 no.6
    • /
    • pp.25-33
    • /
    • 1992
  • 국내에서의 풍력발전 연구는 낙도나 여지와 같은 미전화지역에 적합한 신뢰성있는 풍력발전기를 개발하고 또한 보다 안정된 전력 공합을 위하여 태양광이나 디젤발전과의 복합발전기술을 개발하는 방향으로 추진됨이 요구된다. 아울러 에너지 자립도를 높이고 환경오염을 가능한 한 줄일수 있도록 강풍지역과 풍력자원이 풍부한 지역을 발굴하고 이들 지역에 풍력발전원지를 건설 운용함이 바람직하다.

  • PDF

A Diesel Power Sharing Algorithm for Wind-Diesel Hybrid Electric Power Generation Systems (풍력-디젤 하이브리드 발전 시스템의 디젤 출력 배분 알고리즘 개발)

  • Nam, Yong-Youn;Lee, Geun-Ho;Han, Jeong-Woo;Park, Young-Jun;Lee, Young-Soo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.5
    • /
    • pp.673-678
    • /
    • 2011
  • For the wind-diesel hybrid electric power generation system equiped with two diesel generators, the diesel power sharing is studied analytically and a power sharing technique of less fuel consumption is developed. Based on the technique, as example, a diesel power sharing algorithm is suggested for two diesel generators of capacity 500Kw(200Kw+300Kw).

Modeling of Hybrid Generation System with Wind Turbine, Diesel Generator and Flywheel Energy Storage System (풍력-디젤-플라이휘일 하이브리드 발전시스템 모델링에 관한 연구)

  • Kim, Jae-Eon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2979-2984
    • /
    • 2013
  • This paper proposes a modeling and controller design method of Flywheel Energy Storage System(FESS) for solving the unstable operation problem in hybrid generation system with wind turbine and diesel generator applied in island area. FESS is considered as a permanent magnetic synchronous machine connected to flywheel because of its efficiency. The controller of FESS is composed of AC/DC/AC back-to-back converter. The AC/DC converter is designed to charge/discharge according to the frequency variation and the DC/AC converter to operate to keep the DC bus voltage constant. The proposed modeling and controller design method of FESS was applied to hybrid generation system with wind turbine and diesel generator. The unstable operation problem owing to wind variations was solved through simulation results.

Modeling & Operating Algorithm of Islanding Microgrid with PMSG Wind Turbine and Diesel Generator (영구자석형 풍력-디젤 복합발전시스템 모델링 및 운전제어 알고리즘에 관한 연구)

  • Kim, Jae-Eon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6419-6424
    • /
    • 2015
  • Recently, high-cost energy storage systems are applying to hybrid generation systems with wind turbine and diesel generator in island areas for stable operation. But, this paper proposes an operating algorithm and modeling method of an islanding microgrid that is composed of PMSG(Permanent Magnet Synchronous Generator) and Diesel Generator applied in island areas without such energy storage system. Initially, the operating algorithm was proposed for frequency and voltage to be maintained within the proper ranges for the load and weather change. And then the modeling method were proposed for PMSG, WT-side AC/DC converter and Grid-side DC/AC converter. The proposed operating algorithm and modeling method were applied to a typical islanded microgrid with PMSG wind turbine and diesel generator. The frequency and voltage was kept within the permissible ranges and the proposed method was proven to be appropriate through simulations.

해외동향

  • Korea Electrical Manufacturers Association
    • NEWSLETTER 전기공업
    • /
    • no.97-20 s.189
    • /
    • pp.27-39
    • /
    • 1997
  • PDF

Economic Evaluation between Diesel vs Renewable Energy for Remote Islands (도서지역 기존 디젤과 신재생 전원의 경제성 비교 방안)

  • Kim, Bong-Suck;Jung, Jee-Hong;Kim, Hae-In;Beum, Yoon-Yong;Ryu, Je-Myun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.584-585
    • /
    • 2011
  • 우리나라 자가발전 도서 132개 중 10개 도서를 대상으로 디젤발전과 태양광 풍력의 경제성을 비교하였다. 도서별 전력수요 추정과 함께 발전원의 수명기간 동안 총 비용을 총 발전량으로 나눈 균등화발전단가(원/kWh)를 경제성 분석지표로 사용하였다. 도서별 실제 태양광과 풍황 등 자원량을 반영하지는 않았고 태양광 15%, 풍력 21% 이용률을 가정하였다. 그 결과 4개도서가 경제성 확보가 가능한 것으로 분석되었다. 향후 국가 차원의 손실 최소화 방안 및 국가적 편익 비용을 산출함으로서 향후 도서지역 중장기 경제적 전력공급을 위한 도서 전원 구성에 관한 정책적 방향을 제시할 예정이다.

  • PDF

Economic and Environmental Feasibility on the Wind-Diesel Hybrid Power System in an Island near Seamangeum Area (새만금 부근 섬 지역에서 풍력-디젤 복합 전원 시스템의 경제 및 환경적 타당성에 관한 연구)

  • Seo, Hyun-Soo;Chang, Se-Myong;Kim, Eun-Il
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.277-280
    • /
    • 2006
  • This paper deals with the possibility on the hybrid power system concerning wind energy at a really existing island, Sunyoo-do in the west sea near Seamangeum. In the present stage, Diesel system produces all the electrical power of the Island. However, in the new proposed system of Diesel and wind energy, an optimized guideline for drive from the economic analysis on this hybrid system is given by a mathematical and statistical modelling with a share software HOMER (hybrid optimization model for electric renewables). After a series of analysis it has been shown that the hybrid system can reduce the total expenses as well as air pollution.

  • PDF

Modeling & Operating Algorithm of Islanding Microgrid with Wind Turbine, Diesel Generator and BESS (풍력-디젤-BESS 독립형 마이크로그리드 모델링 및 운전제어 알고리즘에 관한 연구)

  • Kim, Jae-Eon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5893-5898
    • /
    • 2014
  • This paper proposes a modeling method and operating algorithm of an islanding microgrid that is composed of a Battery Energy Storage System (BESS), wind turbine and diesel generator applied in island areas. Initially, the bilateral AC/DC converter was designed for charge/discharge for frequency and voltage to be maintained within the proper ranges according to the load and weather change, and the operating method was proposed for a diesel generator to operate when power supply from the wind turbine or BESS is insufficient. The proposed modeling and controller design method of BESS was applied to a typical islanded microgrid with a wind turbine and diesel generator. The frequency and voltage was kept within the permissible ranges and the proposed method was proven to be appropriate through simulations.