• Title/Summary/Keyword: 풀림 장치

Search Result 24, Processing Time 0.022 seconds

Development on integrated Pay Off Reel for Varied Diameter of Coil Inner (코일 내경 통합 적용형 PAY OFF REEL 개발)

  • Park, Jeong-Ho;Park, Hyoun-Jin;Lee, Dae-Hee;Kim, Soon-Kyoung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.1
    • /
    • pp.61-66
    • /
    • 2010
  • Pay off reel is the device to release in the form of coil. Every time the device becomes a hassle to exchange, each diameter of two forms has been applied to the coil reel. There is the change of reel diameter of the sleeve portion to be the part of segment geometry. This unit is conducting on 3-dimensional modeling design. The basic strength and deformation of the device could be checked in advance by the basis of 3-d modeling data to perform simulations. The production of each part can be completed and assembled. Conducted for the final product which is tested and measured, all items are satisfied within the limits of targets. Due to the development of this device, the efficiency on operations can be increased and the production time becomes shortened.

Comparative analysis of accuracy of how to use the implant torque controllers (사용 방법에 따른 임플란트 토크 조절기의 정확성 비교 분석 연구)

  • Cho, Lee-Ra;Park, Chan-Jin;Huh, Yoon-Hyuk;Lee, Ji-Hye;Kim, Dae-Gon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.300-306
    • /
    • 2013
  • Purpose: This study was to evaluate the accuracy of how to use the Mechanical Torque-Limiting Devices. Materials and methods: Three different implant manufacturers (Dentium, Osstem, Shinhung) were prepared for each two implant torque controllers. Divided into two groups depending on the method used for removal torque was measured. Repeated measures of ANOVA test (${\alpha}=.05$) was used as statistics to evaluate the effect of repeated loading number on the removal torque. Independent t-test was used to evaluate the difference in removal torque of two groups. Results: The removal torque significantly decreased as the number of loading repetition increased (P<.05). There was significant difference between two groups. Conclusion: Loosen the handle part of the implant torque controllers spring resilience to recover one group compared to the group that did not, showed a little more closed to the reference value.

A Study on the Durability Improvement of Movable Bracket Structures (가동 브라킷 구조물의 내구 성능 향상 방안 연구)

  • Park, Yong-Suk;Seo, Jeong-Beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.3
    • /
    • pp.1117-1121
    • /
    • 2011
  • The movable bracket structure, which is an apparatus for supplying electric power to a running electric locomotive, is applied by a repeated load during the passage of the electric locomotive. Such a repeated load becomes an excitation source that causes screws constituting the movable bracket structure to be loosened. This study was conducted on the causes and countermeasures of the bolt loosening caused by the repeated vibration using a computer simulation. As the result, a simulation model was constructed to enable the dynamic analysis of the movable bracket structure. It could be found that the principal excitation frequency range for the bolt loosening of the movable bracket structure was less than 200 Hz. In addition, the bolts are prevented from being loosened by increasing stiffness of H beams. The vibration mode of a lower band bracket is found to be triggered in a frequency range between 300 and 600 Hz. And the increase in stiffness of the lower band bracket exhibits the effect to avoid the bolt loosening at a frequency range of 200 Hz or more.

The effect of a titanium socket with a zirconia abutment on screw loosening after thermocycling in an internally connected implant: a preliminary study (내부연결 임플란트용 타이타늄 소켓을 이용한 지르코니아 지대주에서 열순환이 나사풀림에 미치는 영향: 예비연구)

  • Kyung, Kyu-Young;Cha, Hyun-Suk;Lee, Joo-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.2
    • /
    • pp.114-118
    • /
    • 2017
  • Purpose: The aim of this study was to investigate the effects of a titanium component for the zirconia abutment in the internal connection implant system on screw loosening under thermocycling conditions. Materials and Methods: Internal connection titanium abutments and external connection zirconia abutments with titanium sockets were connected respectively to screw-shaped internal connection type titanium implants with 30 Ncm tightening. These implant-screw-abutment assemblies were divided into two groups of five specimens each; titanium abutments as control and zirconia abutments with titanium sockets as experimental group. The specimens were subjected to 2,000 thermocycles in water baths at $5^{\circ}C$ and $55^{\circ}C$, with 60 seconds of immersion at each temperature. The removal torque values (RTVs) of the abutment screws of the specimen were measured before and after thermocycling. RTVs pre- and post-thermocycling were investigated in statistics. Results: There was not screw loosening identified by tactile and visual inspection in any of the specimens during or after thermocycling. The mean RTV difference for the control group and the experimental group were $-1.34{\pm}2.53Ncm$ and $-1.26{\pm}2.06Ncm$, respectively. Statistical analysis using an independent t-test revealed that no significant differences were found in the mean RTV difference of the groups (P > 0.05). Conclusion: Within the limitations of this in vitro study, the titanium socket for the zirconia abutment did not show a significant effect on screw loosening under thermal stress compared to the titanium abutment in the internal connection implant.

Design of induction heating power supply for forging by interleaved method and current source inverter (인터리브드 방식과 전류원 인버터를 통한 단조용 유도가열 전원장치 설계)

  • Lee, Changwoo;Choi, Seung-Soo;Kim, In-Dong;Jung, Jang Han;Seo, Dong Hoan
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.294-295
    • /
    • 2018
  • 유도가열은 전자기 유도 현상을 이용하여 금속체를 직접 가열하는 방식이며 높은 변환 효율로 전기에너지를 열에너지로 변환할 있다. 이로 인해 금속의 단조, 용해, 표면경화, 풀림 등 여러 응용분야를 통해 철강 및 기계 산업에 기여하고 있다. 단조용 유도가열기 전원장치는 높은 전력용량을 사용하여 주로 SCR을 이용한 위상제어 정류기를 적용한다. 하지만 입력단의 저 역률 및 전류의 THD가 높은 단점을 가진다. 따라서 본 논문에서는 이러한 단점을 보안하기 위해 단조용 유도가열 작업에 맞는 인터리브드 방식의 벅 컨버터와 전류원 인버터를 사용한 고효율 유도가열 전원장치를 제안한다.

  • PDF

Properties of High Impact Resisting Mortar based on Polyurethane (폴리우레탄계 고내충격성 모르타르의 물성치 연구)

  • Lee, Chin-Yong;Choi, Dong-Uk;Ha, Sang-Su;Kim, Dong-Wan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.645-648
    • /
    • 2008
  • The expansion joint is an important part of the bridge, but the failure is occurred on the non-shrinkage concrete which is connected to the slab of the bridge and the expansion joint, and the other problem is the release of anchors in expansion joint due to the impact and vibration during the driven car on the bridge, especially an overloaded car. In this study, to overcome the failure of non-shrinkage of concrete, high impact resisting mortar is developed. The high impact resisting mortar shall be a polyurethane material compounded with an aggregate system to develop excellent flexibility characteristics, high load bearing capacity.

  • PDF

Finite element analysis of the effect of novel Lock Screw system preventing abutment screw loosening (지대주 나사 풀림 방지를 위한 새로운 Lock Screw 시스템의 효과에 대한 유한요소해석적 연구)

  • Im, Eun Sub;Kim, Jong Eun;Kim, Jee Hwan;Park, Young Bum
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.3
    • /
    • pp.132-142
    • /
    • 2019
  • Purpose: The purpose of this finite element analysis study is to introduce the novel Lock screw system and analyze its mechanical property to see if it can prevent abutment screw loosening. Materials and Methods: The Lock screw is a component tightened on the inside of the implant abutment which applies compressive force to the abutment screw head. To investigate the effect, modeling was done using CAD program and it was analyzed by finite element analysis under various load conditions. First, the preload was measured according to the tightening torque of the abutment screw then it was compared with the theoretical value to verify the analytical model. The validated analytical model was then divided into those with no external load and those with 178 N, and the tightening torque of the lock screw was changed to 10, 20, 30 Ncm respectively to examine the property of stress distribution on the implant components. Results: Using Lock screw under various loading conditions did not produce equivalent stresses beyond the yield strength of the implant components. In addition, the axial load was increased at the abutment-abutment screw interface. Conclusion: The use of Lock screw does not exert excessive stress on the implant components and may increase the frictional force between the abutment-abutment screw interface, thus it is considered to prevent loosening of the abutment screw.

Fatigue Analysis for Locking Device in Landing Gear Retract Actuator (착륙장치 작동기 내부 잠금장치 피로해석)

  • Lee, Jeong-Sun;Kang, Shin-Hyun;Jang, Woo-Chul;Lee, Seung-Gyu;Oh, Seong-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.1
    • /
    • pp.91-96
    • /
    • 2012
  • The retract actuator makes the landing gear retract or extend during take-off and landing of an aircraft. To prevent folding of landing gear that has remained in the extended state because of an unexpected external disturbance, an internal locking device is applied to the retract actuator. The locking device is restrained with another internal component by oil pressure supplied to the retract actuator, and this restraint makes the locking of the actuator possible. Because locking and unlocking are repeated during retraction and extension of the landing gear, the locking device takes repeated identical loads, and the possibility of fatigue failure exists. In this study, the process and results of fatigue analysis for the locking device are presented, and the appropriateness of the analysis result is verified using a fatigue test.

A Study on the Improvement of Passenger Ship Rudder Stock and Tiller Locking Nut Loosening by Analyzing an Investigation Report and the NAS 3350 Test (조타장치 사고 재결서 분석과 NAS 3350 시험을 통한 카페리 여객선 타두재와 틸러 체결 너트 풀림 개선에 관한 연구)

  • Kang, Dae-Kon;Kim, Shin Hyo;Park, Jai-Hak
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.2
    • /
    • pp.253-259
    • /
    • 2018
  • In February 2014, the rudder upper stock and the nut of a passenger ship were released and an accident occurred. That accident occurred because the steering gear of passenger ships that was intended to move many passengers. The accidents due to steering gear was zero according to 2010-2016 statistics. There is no rules prevent loosening of the upper rudder nut in "Ship Safety Act" and "Structural standard of steel ship". Since the accident, the Korea register has been revised to the joining method in Part 5 Chapter 7 of the rules in the classification of steel ships. In the field survey of 12 passenger ships operating on Mokpo and surrounding islands, the welding method was applied in the cases as the fastening method. The fastening type was equipped with two C-type structures. It was structured to be difficult to access. The NAS 3350 test was conducted to investigate ways to prevent homologous accident considering the characteristic of passenger ships that need to lift or unload rides once a year.

Implant overdenture using milled bar and attachment in partially edentulous mandible: a case report (하악 부분 무치악 환자에서 Milled Bar와 부착장치를 이용한 임플란트 피개의치 수복 증례)

  • Kim, Min-Jung;Huh, Jung-Bo;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Jo, Yong-Bum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.71-79
    • /
    • 2022
  • Excessive crown height space increases can cause crestal bone loss and screw loosening after prosthesis is placed. Milled bar and implant overdenture can be used as a treatment method for partially edentulous patients who have severe alveolar bone loss and excessive crown height space. Milled bar can provide primary splinting effect and stability between implants. Also, milled bar with additional retention device such as Advanced Dental Device-Treatment Of Choice (ADD-TOC) and magnet can provide additional retention force for implant overdenture. In this case, the patient has a partially edentulous mandible that has severe alveolar bone loss and multiple number of teeth loss after excision due to leiomyosarcoma. Because of the long-term loss of mandibular molars, the opposing teeth were extruded. Maxillary left molars were corrected to the occlusal plane through molar intrusion, and mandibular left molar region were treated with implant overdenture, using milled bar with ADD-TOC and magnet after implant placement. The clinical result was satisfactory on the aspect of esthetic and masticatory function.