Drying Shrinkage Evaluation of Concretes with Various Volume-Surface Ratios, Aggregate Types and Concrete Pavement Mixes (시험체 형상비와 골재종류 및 배합특성에 따른 건조수축 특성평가)

  • Yang, Sung-Chul
    • International Journal of Highway Engineering
    • /
    • v.14 no.1
    • /
    • pp.45-53
    • /
    • 2012
  • This study was performed to analyze test results on drying shrinkage for concrete specimens mixed with various constituents in concrete mixes. Test variables are coarse aggregate types(Limestone, Sandstone, Granite, Andesite, Gneiss), fine aggregate types(natural sand, crushed sand) and cement amounts(normal strength, high strength). Epoxy coating of(U&V-H(A,B)) was applied onto the specimen surface to simulate diverse volume surface ratios(22.2, 40, 85.7, 150, 200, 300) with different specimen sizes. The experiments had been executed during 1,014 days at a condition of $20^{\circ}C$ and relative humidity of 60% in environmental chambers. Test results showed that shrinkage strain from the specimen equivalent to real pavement decreased to 39% compared to the standard specimen recommended by KS. Test results also showed that shrinkage strain of the specimen mixed with Limestone was 56~76% of that with Sandstone, thus Limestone mix seems to be suitable to the concrete pavement.

Matrix Effects on X-Ray Fluorescence Intensities in Fe-Ni-Cr System (철-니켈-크롬 三成分系에서 X-線 螢光의 매트릭스 效果에 관한 硏究)

  • Yang Che-Hyon;Yeh Jin-Hae
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.10
    • /
    • pp.861-866
    • /
    • 1993
  • In general, the concentration of constituents can be more accurately measured in x-ray fluorescence analysis of Fe-Ni-Cr alloy by reducing and correcting the matrix effect with standard ingot samples. Because of the difficult the treatment at a high temperature in preparing the ingot samples of various concentrations, several standard specimens were prepared by mixing the powders of the metallic oxides in certain proportions and pressing them with a costant pressure. With the metallic oxide specimens thus obtained, different matrix coefficients were calculate from the intensities of the strength of the x-ray fluorescence and the concentration of the substances. It is found that effects of Fe and Cr on Ni are absorption rich and effects of Fe and Ni on Cr are enhancement rich, whereas Ni enhances Fe Fluorescence but Cr absorves Fe K${\alpha}$ line. And the x-ray fluorescence intensities were compared and analyzed between the metallic oxides and the ingot samples.

  • PDF

탄소와 질소 함량 변화에 따른 type 347 스테인리스강의 피로균열거동 연구

  • Min, Gi-Deuk;Kim, Dae-Hwan;Lee, Bong-Sang;Kim, Seon-Jin
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.42.1-42.1
    • /
    • 2009
  • 오스테나이트 스테인리스강은 우수한 내식성 및 기계적 특성으로 인해 구조용 재료로 널리 사용되고 있다. 표준원전 경수로의 경우 가압기 밀림관소재로 Nb 안정화 오스테나이트 스테인리스강인 type 347 스테인리스강이 사용되고 있다. 그러나 원전배관에서는 운전중 배관내 온도편차에 의한 열응역과 하중변화에 의한 기계적하중에 의해 피로손상을 받는다. 일반적으로 범용 오스테나이트 스테인리스강(AISI 304, 316)의 피로균열 성장거동에 대한 연구결과는 국내외적으로 다수 축적되어 있으나 type 347 탄소, 질소 함량에 따른 기계적 특성 및 피로균열성장 연구는 매우 미비하다. 따라서 본 연구에서는 탄소와 질소의 함량에 따른 기계적거동을 평가하고, 이에 따른 피로균열전파속도를 관찰하여 스테인리스강의 정확한 피로균열전파속도 곡선을 제시하고자 한다. 실험에 사용된 시편은 두께 5mm, 폭 25.4mm CT시편을 사용하였으며, 1mm의 예비균열을 주었다. 그리고 실험온도는 상온과 원전가동온도인 $316^{\circ}C$에서 실시하였으며, 주파수는 10Hz를 주었다. 실험결과 각 함량에 따른 type 347의 미세조직 관찰결과 기지내에 압연방향을 따라 조대한 석출물의 흐름이 관찰되었으며, 크기나 분포가 큰 차이를 보였다. C+N 함량이 낮은 시편은 주로 $0.1\;{\mu}m$ 이하의 미세한 입자들이 오스테나이트 기지조직의 입내와 입계에 고르게 분포되어 있었다. 그러나 C+N 함량이 높은 시편의 경우에는 $0.1\;{\mu}m$ 이하의 미세한 입자들과 함께 국부적으로 $1\sim10\;{\mu}m$의 조대한 입자들이 분포하고 있는 것이 관찰되었다. 그리고 질소의 함량이 높아짐에 따라 인장강도는 증가하였으며, 피로시험결과 고온에서 실험한 피로균열성장률 곡선이 상온보다 높게 나타남을 확인할 수 있었다. 그리고 질소가 적게 첨가되고 탄소의 함량이 많을수록 피로균열성장률은 ASME 곡선보다 낮게 나타났다.

  • PDF

Physical Property of W-C-N Diffusion Barrier through Stress-Strain curve (Stress-Strain curve를 이용한 W-C-N 확산방지막 물성 특성 연구)

  • Lee, Kyu-Young;Kim, Soo-In;Park, Sang-Jae;Lee, Dong-Kwan;Jeong, Yong-Rok;Jung, Jun;Lee, Jong-Rim;Lee, Chang-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.4
    • /
    • pp.266-270
    • /
    • 2011
  • This paper suggest tungsten (W)-carbon (C)-nitrogen (N) thin films for diffusion barrier that W is main material and C and N are additives. W-C-N thin films are deposited with fixed rates of W and C but with a variation of $N_2$ gas flow and W-C-N thin films are heated at $600^{\circ}C$. From the experimental results, the variation of elastoplastic region for W-C-N thin film measured by tribological property is larger than that of elastic region with a variation of $N_2$ gas flow. These results show that the $N_2$ gas flow is more directly related with the elastoplastic region of W-C-N thin film. Nanoindenting test executed 16 times consecutively and we got the stress-strain curve graphs and hardness datas at each sample. Through the stress-strain curve graphs, the standard diviation of stress-strain curve for $N_2$ gas flow rate of 2.0 sccm is smaller than that of 0, 0.5, 1.5 sccm. Consequently, the physical stability of W-C-N thin film depends on the flow rate of $N_2$ gas.

Chemical Analysis and Thermoelectric Properties of the PbSnTe Semiconductors (화학조성에 따른 PbSnTe계 반도체의 열전특성조사)

  • Oh, Kyu-Whan;Oh, Seung-Mo
    • Applied Chemistry for Engineering
    • /
    • v.1 no.1
    • /
    • pp.83-90
    • /
    • 1990
  • The semiconducting $(Pb_1\;_xSn_x)_1$ $_yTe_y$, one of the low - temperature thermoelectric materials, has been prepared and its chemical composition and nonstoichiometry has been analyzed. The content of Pb in the specimens was determined by the complexometric back - titration method with EDTA and Pb(II) standard solutions. Te - content was analyzed with the redox titration method. The electrical conductivity and the thermoelectric power have also been measured by the DC 4 - probe and the heat-pulse technique, respectively. All of the specimens showed a nonstoichiometric behavior in their chemical compositions (Te excess), thus gave rise to a p - type semiconducting property, and the nonstoichoimetry became bigger as the Sn - content increased. The thermoelectric power vs. temperature results have been analyzed upon the basis of the Fermi level vs. temperature profiles in the saturation regime. The specimen of x=0.1 evolved a transition from p - to n - type property at about 670K, which has been explained by the fact that the mobility of electrons is bigger than that of holes in the temperature range of the intrinsic regime.

  • PDF

Preparation and Characterization of New Conversion Coating Solutions for Good Corrosion Resistance on Magnesium Plate (마그네슘판재의 고내식 화성처리 용액제조 및 특성 고찰)

  • Jeong, Yong-Gyun;Lee, Jae-Ryung
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.114-114
    • /
    • 2009
  • 마그네슘은 실용금속 중에서 열역학적으로 가장 활성이 큰 부류에 속하며, 그 표준적극전위는 -2.363VNHE (NHE: 수소표준전극기준)으로 대기중에서 표면부터 신속하게 산화되는 내식성에 큰 취약점을 가지고 있어, 내식성과 낮은 표면전기저항성을 갖는 마그네슘판재용 화성처리를 제안하기 위해 망간-인산염, 바나듐, 세륨, 불화 실리콘 등의 화합물로 구성되는 여러 가지의 화성처리용액을 제조한 뒤 침지처리시간을 달리하는 방법으로 마그네슘판재를 코팅하였다. 코팅된 시편을 이용하여 색상과 광택, 표면전기저항, 내식성 등에 대한 특성을 고찰하였다.

  • PDF

Magnetoelastic Force Sensor Using Amorphous Alloy (비정질합금을 이용한 자기탄성 힘센서)

  • Son, D.;Kim, C.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.1 no.1
    • /
    • pp.37-41
    • /
    • 1991
  • A force sensor which employ the measurement of the change in the maximum induction of an amorphous core was constructed. This force sensor has a standard deviation of the non-linearity less than 0.1% within the range of 0 to 1 N, and a resolution of $1{\times}10^{-4}N$ for the core cross section of $6{\times}10^{-8}/m^{2}$. The sensor can also measure transient force at a sampling rate of 10 kHz which is the same as the magnetizing frequency of the core.

  • PDF

THE COMPARATIVE STUDY ON THE COLOR OF THE DECIDUOUS TEETH AND RESTORATIVE MATERIALS (유치의 치아색과 수복재의 색조선택에 관한 비교연구)

  • Baik, Byeong-Ju;Oh, Kyoung-Seon;Kim, Jae-Gon;Yang, Cheol-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.3
    • /
    • pp.376-381
    • /
    • 2002
  • The purpose of this study was to analyse the color of natural deciduous teeth in Korean children and to compare with that of composite resin specimens. The subjects were 148 children (80 boys and 68 girls) with good general condition and normal teeth color, aged between 3 and 6 years. The color of middle third of maxillary central incisor in deciduous teeth was examined with shade guide and then measured by means of the colorimeter CV300 which can be measured by CIELAB system. The data were analyzed statistically by SPSS program. The results were summerized as follows; 1. Over 90% of the color for the deciduous anterior teeth was in A1, A2, B1, B2 and P shade. 2. The means of deciduous teeth color were $L^*=58.72,\;a^*=-1.18,\;b^*=-0.63$ by colorimeter CV300. 3. $L^*,\;a^*\;and\;b^*$ prices for A1, A2, B1, B2, P were $L^*=52.52,\;a^*=-1.90,\;b^*=1.18$ in A1 specimen, $L^*=54.90,\;a^*=-1.87,\;b^*=1.60$ in A2 specimen, $L^*=59.80,\;a^*=-2.70,\;b^*=-0.63$ in B1 specimen, $L^*=56.90,\;a^*=-1.70,\;b^*=1.63$ in B2 specimen, $L^*=52.93,\;a^*=-2.33,\;b^*=1.10$ in P specimen. The means of B1 color specimen were most similar to those of deciduous teeth color. The A1 color values were similar to the P color values. 4. The standard deviation of $L^*,\;a^*$ was small among colors, but that of $b^*$, in the yellowish color, was large.

  • PDF

Measurements of Two-dimensional Gratings Using a Metrological Atomic Force Microscope and Uncertainty Evaluation (길이 표준 소급성을 갖는 원자간력 현미경을 이용한 2차원 격자 시편 측정과 불확도 평가)

  • Kim, Jong-Ahn;Kim, Jae-Wan;Kang, Chu-Shik;Eom, Tae-Bong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.9
    • /
    • pp.68-75
    • /
    • 2007
  • The pitch and orthogonality of two-dimensional (2D) gratings have been measured by using a metrological atomic force microscope (MAFM) and measurement uncertainty has been analyzed. Gratings are typical standard artifacts for the calibration of precision microscopes. Since the magnification and orthogonality in two perpendicular axes of microscopes can be calibrated simultaneously using 2D gratings, it is important to certify the pitch and orthogonality of 2D gratings accurately for nano-metrology using precision microscopes. In the measurement of 2D gratings, the MAFM can be used effectively for its nanometric resolution and uncertainty, but a new measurement scheme was required to overcome some limitations of current MAFM such as nonnegligible thermal drift and slow scan speed. Two kinds of 2D gratings, each with the nominal pitch of 300 nm and 1000 nm, were measured using line scans for the pitch measurement of each direction. The expanded uncertainties (k = 2) of measured pitch values were less than 0.2 nm and 0.4 nm for each specimen, and those of measured orthogonality were less than 0.09 degree and 0.05 degree respectively. The experimental results measured using the MAFM and optical diffractometer were coincident with each other within the expanded uncertainty of the MAFM. As a future work, we also proposed another scheme for the measurements of 2D gratings to increase the accuracy of calculated peak positions.

Scale Effects of the Specimen on Shear Strength of sand by Direct Shear Test (직접전단시험에 의한 모래의 전단강도에서 시편의 크기효과)

  • Kim, Joon-Seok;Kim, Ji-Hyun
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.4
    • /
    • pp.590-596
    • /
    • 2019
  • Purpose: An experimental study was conducted on the sand samples for the size effect of the test specimens, one of the problems of the direct shear test. Method: Jumunjin standard sand, a representative sand of Korea, was used as sand sample. The large direct shear test was performed to analyze the shear strength at 50%, 60%, 70%, and 80% relative density, and then the comparative results were compared with the test results of the small direct shear test. Result: It was analyzed that the internal friction angle of the small shear tester tended to be relatively large in the dense region. It was analyzed that the results of the large shear tester tend to be relatively large in the region of medium relative density. Conclusion: The size effect on the samples in the direct shear test on sandy soil was analyzed to be relatively small.