• Title/Summary/Keyword: 표준화환자

Search Result 371, Processing Time 0.03 seconds

A Study on the Optimal Image Acquisition Time of 18F- Flutemetamol using List Mode (LIST mode를 이용한 18F-Flutemetamol 의 최적 영상획득 시간에 관한 연구)

  • Ryu, Chan-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.891-897
    • /
    • 2021
  • With the development of Amyloid PET Tracer, the accuracy of Alzheimer's diagnosis can be improved through the identification of beta-amyloid neurites. However, the long image acquisition time of 20 minutes can be difficult for the patient. PET/CT scans are sensitive to patient movement and may partially affect test results. In this study, we studied the proper image acquisition time without affecting the quantitative evaluation of the image through the list mode acquisition method according to the time of the distribution of radioactive drugs in the body. The list mode includes information about time compared to the existing frame mode, and it is easy to analyze data because it can reconstruct images about the time that researchers want. The research method obtained a reconstructed image by time using a list mode of 5min frame/bed, 10min frame/bed, 15min frame/bed, and 20min frame/bed to compare the difference between signal-to-pons take ratio (SNR) and lesion-to-pons uptake ratio (LPR) and the difference in reading time to obtain an appropriate image. As a result of quantitative analysis, when measuring in list mode, SUVmean values decreased in 6 regions of interest as the image acquisition time increased, but showed the largest difference in 5 min/bed images, followed by 10 min/bed and 15 min/bed. As a result, the difference in SUVmean values decreased. Therefore, it was found that SUVmean values at 15 min/bed did not differ enough to not affect image evaluation. There was no difference in LPR values. As a result of the qualitative analysis, there was no change in the reading findings according to the PET image acquisition time and there was no significant difference in the qualitative analysis score of the image reconstruction according to time. As a result of the study, there is no significant difference between 15 min/bed and 20 min/bed images during the 18F-flutemetamol PET/CT test, so it can be said that it is clinically useful to reduce the image acquisition time selectively using 15 min/bed via list mode depending on the patient's condition.

Association between Medial Temporal Atrophy, White Matter Hyperintensities, Neurocognitive Functions and Activities of Daily Living in Patients with Alzheimer's Disease and Mild Cognitive Impairment (알츠하이머병 및 경도인지장애 환자에서 내측두엽 위축, 대뇌백질병변, 신경인지기능과 일상생활 수행능력과의 연관성)

  • An, Min hyuk;Kim, Hyun;Lee, Kang Joon
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.29 no.1
    • /
    • pp.67-76
    • /
    • 2021
  • Objectives : The aim of this study was to compare activities of daily living (ADLs) according to degenerative changes in brain [i.e., medial temporal lobe atrophy (MTA), white matter hyperintensities] and to examine the association between neurocognitive functions and ADLs in Korean patients with dementia due to Alzheimer's disease (AD) and mild cognitive impairment (MCI). Methods : Participants were 111 elderly subjects diagnosed with AD or MCI in this cross-sectional study. MTA in brain MRI was rated with standardized visual rating scales (Scheltens scale) and the subjects were divided into two groups according to Scheltens scale. ADLs was evaluated with the Korean version of Blessed Dementia Scale-Activity of daily living (BDS-ADL). Neurocognitive function was evaluated with the Korean version of the Consortium to Establish a Registry for Alzheimer's Disease assessment packet (CERAD-K). Independent t-test was performed to compare ADLs with the degree of MTA. Pearson correlation and hierarchical multiple regression analyses were performed to analyze the relationship between ADLs and neurocognitive functions. Results : The group with high severity of the MTA showed significantly higher BDS-ADL scores (p<0.05). The BDS-ADL score showed the strongest correlation with the word list recognition test among sub-items of the CERAD-K test (r=-0.568). Findings from the hierarchical multiple regression analysis revealed that the scores of MMSE-K and word list recognition test were factors that predict ADLs (F=44.611, p<0.001). Conclusions : ADLs of AD and MCI patients had significant association with MTA. Our study, which identifies factors correlated with ADLs can provide useful information in clinical settings. Further evaluation is needed to confirm the association between certain brain structures and ADLs.

Usefulness Evaluation of Artifacts by Bone Cement of Percutaneous Vertebroplasty Performed Patients and CT Correction Method in Spine SPECT/CT Examinations (척추 뼈 SPECT/CT검사에서 경피적 척추성형술 시행 환자의 골 시멘트로 인한 인공물과 CT보정방법의 유용성 평가)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.49-61
    • /
    • 2014
  • Purpose: With the aging of the population, the attack rate of osteoporotic vertebral compression fracture is in the increasing trend, and percutaneous vertebroplasty (PVP) is the most commonly performed standardized treatment. Although there is a research report of the excellence of usefulness of the SPECT/CT examination in terns of the exact diagnosis before and after the procedure, the bone cement material used in the procedure influences the image quality by forming an artifact in the CT image. Therefore, the objective of the research lies on evaluating the effect the bone cement gives to a SPECT/CT image. Materials and Methods: The images were acquired by inserting a model cement to each cylinder, after setting the background (3.6 kBq/mL), hot cylinder (29.6 kBq/mL) and cold cylinder (water) to the NEMA-1994 phantom. It was reconstructed with Astonish (Iterative: 4 Subset: 16), and non attenuation correction (NAC), attenuation correction (AC+SC-) and attenuation and scatter correction (AC+SC+) were used for the CT correction method. The mean count by each correction method and the count change ratio by the existence of the cement material were compared and the contrast recovery coefficient (CRC) was obtained. Additionally, the bone/soft tissue ratio (B/S ratio) was obtained after measuring the mean count of the 4 places including the soft tissue(spine erector muscle) after dividing the vertebral body into fracture region, normal region and cement by selecting the 20 patients those have performed PVP from the 107 patients diagnosed of compression fracture. Results: The mean count by the existence of a cement material showed the rate of increase of 12.4%, 6.5%, 1.5% at the hot cylinder of the phantom by NAC, AC+SC- and AC+SC+ when cement existed, 75.2%, 85.4%, 102.9% at the cold cylinder, 13.6%, 18.2%, 9.1% at the background, 33.1%, 41.4%, 63.5% at the fracture region of the clinical image, 53.1%, 61.6%, 67.7% at the normal region and 10.0%, 4.7%, 3.6% at the soft tissue. Meanwhile, a relative count reduction could be verified at the cement adjacent part at the inside of the cylinder, and the phantom image on the lesion and the count increase ratio of the clinical image showed a contrary phase. CRC implying the contrast ratio and B/S ratio was improved in the order of NAC, AC+SC-, AC+SC+, and was constant without a big change in the cold cylinder of the phantom. AC+SC- for the quantitative count, and AC+SC+ for the contrast ratio was analyzed to be the highest. Conclusion: It is considered to be useful in a clinical diagnosis if the application of AC+SC+ that improves the contrast ratio is combined, as it increases the noise count of the soft tissue and the scatter region as well along with the effect of the bone cement in contrast to the fact that the use of AC+SC- in the spine SPECT/CT examination of a PVP performed patient drastically increases the image count and enables a high density of image of the lesion(fracture).

  • PDF

Comparative Analysis of Delivery Management in Various Medical Facilities (의료기관별 분만관리 양상의 비교 분석)

  • Park, Jung-Han;You, Young-Sook;Kim, Jang-Rak
    • Journal of Preventive Medicine and Public Health
    • /
    • v.22 no.4 s.28
    • /
    • pp.555-577
    • /
    • 1989
  • This study was conducted to compare the delivery management including laboratory tests, medication and surgical procedures for the delivery in various medical facilities. Two university hospitals, two general hospitals, three hospitals, two private obstetric clinics, and two midwifery clinics in a large city were selected as they permitted the investigators to abstract the required data from the medical and accounting records. The total number of deliveries occurred at these 11 facilities between 15 January and 15 February, 1989 was 789 among which 606(76.8%) were vaginal deliveries and 183 (23.3%) were C-sections. For the normal vaginal deliveries, CBC, Hb/Hct level, blood typing, VDRL, hepatitis B antigen and antibody, and urinalysis were routinely done except the private clinics and midwifery clinics which did not test for hepatitis B and Hb/Hct level at all. In one university hospital ultrasonography was performed in 71.4% of the mothers and in one general hospital liver function test was done in 76.7% of the mothers. For the C-section, chest X-ray, bleeding/clotting time and liver function test were routinely done in addition to the routine tests for the normal vaginal deliveries. Episiotomy was performed in 97.2% of the vaginal deliveries. The type and duration of fluid infused and antibiotics administered showed a wide variation among the medical facilities. In one university hospital antibiotics was not administered after C-section at all while in the general hospitals and hospitals one or two antibiotics were administered for one week on the average. In one private clinic one pint of whole blood was transfused routinely. A wide variation was observed among the medical facilities in the use of vitamin, hemostatics, oxytocics, antipyreptics, analgesics, anti-inflammatory agents. sedatives. digestives. stool softeners. antihistamines. and diuretics. Mean hospital day for the normal vaginal deliveries of primipara was 2.6 days with little variation except one hospital with 3.5 days. Mean hospital day for the C-section of primipara was 7.5 days and that of multipara was 7.6 days and it ranged between 6.5 days and 9.4 days. Average hospital fee for a normal vaginal delivery without the medical insurance coverage was 182,100 Won for the primipara and 167,300 Won for the multipara. In case of the primipara covered by the medical insurance a mother paid 82,400 Won and a multiparous mother paid 75,600 Won. Average hospital fee for a C-section without the medical insurance was 946,500 Won for the primipara and 753,800 Won for the multipara. In case of the primipara covered by the medical insurance a mother paid 256,200 Won and a multiparous mother paid 253,700 Won. Average hospital fee for a normal vaginal delivery in the university hospitals showed a remarkable difference, 268,000 Won vs 350,000 Won, as well as for the C-section. A wide variation in the laboratory tests performed for a normal vaginal delivery and a C-section as well as in the medication and hospital days brought about a big difference in the hospital fee and some hospitals were practicing the case payment system. Thus, standardization of the medical care to a certain level is warranted for the provision of adequate medical care for delivery.

  • PDF

A study of facial soft tissue of Korean adults with normal occlusion using a three-dimensional laser scanner (3차원 레이저 스캐너를 이용한 한국 성인 정상교합자의 안면 연조직에 대한 연구)

  • Baik, Hyoung-Seon;Jeon, Jai-Min;Lee, Hwa-Jin
    • The korean journal of orthodontics
    • /
    • v.36 no.1 s.114
    • /
    • pp.14-29
    • /
    • 2006
  • Developments in computer technology have made possible the 3-dimensional (3-D) evaluation of hard and soft tissues in orthodontic diagnosis, treatment planning and post-treatment results. In this study, Korean adults with normal occlusion (male 30, female 30) were scanned by a 3-D laser scanner, then 3-D facial images formed by the Rapidform 2004 program (Inus Technology Inc., Seoul, Korea.). Reference planes in the facial soft tissue 3-D images were established and a 3-D coordinate system (X axis-left/right, Y axis-superior/inferior, Z axis-anterior/posterior) was established by using the soft tissue nasion as the zero point. Twenty-nine measurement points were established on the 3-D image and 43 linear measurements, 8 angular measurements, 29 linear distance ratios were obtained. The results are as follows; there were significant differences between males and females in the nasofrontal angle $(male:\;142^{\circ},\;female:\;147^{\circ})$ and transverse nasal prominence $(male:\;112^{\circ},\;female:\;116^{\circ})$ (p<0.05). The transverse upper lip prominence was $107^{\circ}$ in males, $106^{\circ}$ in females and the transverse mandibular prominence was $76^{\circ}$ in both males and females. Li-Me' was 0.4 times the length of Go-Me'(mandibular body length) and the mouth height was also 0.4 times the width of the mouth width. The linear distance ratio from the coronal reference plane of FT, Zy, Pn, ULPm, Li, Me' was -1/-1/1/0.5/0.5/-0.6 respectively. The 3-D facial model of Korean adults with normal occlusion were be constructed using coordinate values and linear measurement values. These data may be used as a reference in 3-D diagnosis and treatment planning for malocclusion and dentofacial deformity patients and applied for 3-D analysis of facial soft tissue changes before and after orthodontic treatment and orthognathic surgery.

An Analysis of Ten Year Trends of Cancer Incidence and Quality Control of Cancer Registration Data in Jeollabuk-do, Korea: 2001~2010 (전라북도의 10년간(2001~2010) 암 발생률 추이 및 암등록 자료의 질 관리 지표 분석)

  • Lee, Byeong Ki
    • Journal of agricultural medicine and community health
    • /
    • v.39 no.1
    • /
    • pp.46-58
    • /
    • 2014
  • Objectives: This study was aimed to analyze the trends of cancer incidence and evaluate the quality control of cancer registration data in Jeollabuk-do from 2001 to 2010. Methods: Incidence data of all cancers and indices of quality of cancer registration data in Jeollabuk-do for the 10-year period were obtained from the Population-based Regional Cancer Registry in the Jeonbuk Regional Cancer Center. Trends in crude incidence rate (CR) and age-standardized incidence rate (ASR) for all cancers and incidence rates for major cancer sites by gender were analyzed. Joinpoint regression tool was used to describe and quantify trends. And the completeness and validity of cancer registration data were analyzed. Results: The major cancer sites in males were the stomach (22.2%), lung (16.6%), colorectum (12.8%), liver (12.3%) and prostate (6.2%), and in females were the thyroid (17.8%), stomach (14.7%), breast (11.6%), colorectum (11.5%) and lung (7.7%). Between 2001 to 2010, ASR for all cancers increased 13.7% in men, 68% in women, and 36.5% overall. ASR for all cancers increased by 1.2% per year in males and by 6.7% per year in females from 2001 to 2010. In the quality control of the cancer registration data between 2001 and 2010, death certificate only (DCO%) for men was decreased from 5.6% to 1.3% and DCO% for women decreased from 6.1% to 1.8%. Microscopic verification (MV%) increased in both men and women. And mortality/incidence ratio (MI%) declined in both men and women. Conclusions: The cancer incidence during the 10 years (2001-2010) in Jeollabuk-do was increasing especially for the colorectum and prostate in men, and for the thyroid and breast in women. The overall quality control of the cancer registry was gradually improving.

Preliminary Study on the Standardization of Korean Version of Type D Personality Scale 14 : Internal Consistency and Construct Validity (D형 인격 척도의 표준화 예비연구 : 내적일치도 및 구성타당도)

  • Lee, Moon-Soo;Park, Young-Min;Lim, Hong-Euy;Song, Woo-Hyuk;Ahn, Jung-Chun;Kim, Seong-Hwan;Lee, Bun-Hee;Han, Chang-Su;Kim, Yong-Ku;Joe, Sook-Haeng;Ko, Young-Hoon
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.15 no.2
    • /
    • pp.81-87
    • /
    • 2007
  • Objectives : The distressed personality (type-D) pattern, consisting of negative affectivity and social inhibition, has been shown by Denollet et al. For measuring the Type D characteristics, Denollet has devised the 14 item Type D scale (DS14). In the present study, this instrument was translated into Korean. The reliability and validity of the Korean DS14 was pilot tested. Methods : Preliminary version of the total 17-item DS14 scale was translated into Korean. 372 controls that did not have any coronary heart diseases (CHD) were randomly sampled in Seoul and Gyeonggi province. Preliminary Korean version was applied to controls and 14 items were finally selected to maximize reliability of the scale. We compared the distribution of type-D personality among the normal controls, hypertensive patients, and the CHD patients. Results : 7 of 10 items in social inhibition were selected and final 14-item version was made. The internal consistency of negative affectivity (0.817) and social inhibition (0.797) were high. In addition, the prevalence of type-D personality in the CHD patients group was significantly higher than normal controls. Conclusion : These findings suggest that Korean version of DS14 is a valid tool for measuring the type D characteristics. Type-D characteristics can be suggested to predict adverse prognosis in patients with CHD.

  • PDF

Performance effectiveness of pediatric index of mortality 2 (PIM2) and pediatricrisk of mortality III (PRISM III) in pediatric patients with intensive care in single institution: Retrospective study (단일 병원에서 소아 중환자의 예후인자 예측을 위한 PIM2 (pediatric index of mortality 2)와 PRIMS III (pediatric risk of mortality)의 유효성 평가 - 후향적 조사 -)

  • Hwang, Hui Seung;Lee, Na Young;Han, Seung Beom;Kwak, Ga Young;Lee, Soo Young;Chung, Seung Yun;Kang, Jin Han;Jeong, Dae Chul
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.11
    • /
    • pp.1158-1164
    • /
    • 2008
  • Purpose : To investigate the discriminative ability of pediatric index of mortality 2 (PIM2) and pediatric risk of mortality III (PRISM III) in predicting mortality in children admitted into the intensive care unit (ICU). Methods : We retrospectively analyzed variables of PIM2 and PRISM III based on medical records with children cared for in a single hospital ICU from January 2003 to December 2007. Exclusions were children who died within 2 h of admission into ICU or hopeless discharge. We used Students t test and ANOVA for general characteristics and for correlation between survivors and non-survivors for variables of PIM2 and PRISM III. In addition, we performed multiple logistic regression analysis for Hosmer-Lemeshow goodness-of-fit, receiver operating characteristic curve (ROC) for discrimination, and calculated standardized mortality ratio (SMR) for estimation of prediction. Results : We collected 193 medical records but analyzed 190 events because three children died within 2 h of ICU admission. The variables of PIM2 correlated with survival, except for the presence of post-procedure and low risk. In PRISM III, there was a significant correlation for cardiovascular/neurologic signs, arterial blood gas analysis but not for biochemical and hematologic data. Discriminatory performance by ROC showed an area under the curve 0.858 (95% confidence interval; 0.779-0.938) for PIM2, 0.798 (95% CI; 0.686-0.891) for PRISM III, respectively. Further, SMR was calculated approximately as 1 for the 2 systems, and multiple logistic regression analysis showed ${\chi}^2(13)=14.986$, P=0.308 for PIM2, ${\chi}^2(13)=12.899$, P=0.456 for PRISM III in Hosmer-Lemeshow goodness-of-fit. However, PIM2 was significant for PRISM III in the likelihood ratio test (${\chi}^2(4)=55.3$, P<0.01). Conclusion : We identified two acceptable scoring systems (PRISM III, PIM2) for the prediction of mortality in children admitted into the ICU. PIM2 was more accurate and had a better fit than PRISM III on the model tested.

Usefulness of Dynamic $^{18}F-FDG$ PET Scan in Lung Cancer and Inflammation Disease (폐암과 폐 염증성질환의 동적양전자방출단층검사 (Dynamic $^{18}F-FDG$ PET)의 유용성)

  • Park, Hoon-Hee;Roh, Dong-Wook;Kim, Sei-Young;Rae, Dong-Kyeong;Lee, Min-Hye;Kang, Chun-Goo;Lim, Han-Sang;Oh, Ki-Back;Kim, Jae-Sam;Lee, Chang-Ho
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.249-255
    • /
    • 2006
  • Purpose: The diagnostic utility of fluorine-18 2-deoxy-D-glucose positron emission tomograhpy ($^{18}F-FDG $PET) for the non-invasive differentiation of focal lung lesions originated from cancer or inflammation disease by combined visual image interpretation and semi-quantitative uptake value analysis has been documented. In general, Standardized Uptake Value(SUV) is used to diagnose lung disease. But SUV does not contain dynamic information of lung tissue for the glucose. Therefore, this study was undertaken to hypothesis that analysis of dynamic kinetics of focal lung lesions base on $^{18}F-FDG$ PET may more accurately determine the lung disease. So we compared Time Activity Curve(TAC), Standardized Uptake Value-Dynamic Curve(SUV-DC) graph pattern with Glucose Metabolic Rate(MRGlu) from Patlak analysis. Methods: With lung disease, 17 patients were examined. They were injected with $^{18}F-FDG$ over 30-s into peripheral vein while acquisition of the serial transaxial tomographic images were started. For acquisition protocol, we used twelve 10-s, four 30-s, sixteen 60-s, five 300-s and one 900-s frame for 60 mins. Its images were analyzed by visual interpretation TAC, SUV-DC and a kinetic analysis(Patlak analysis). The latter was based on region of interest(ROIs) which were drawn with the lung disease shape. Each optimized patterns were compared with itself. Results: In TAC patterns, it hard to observe cancer type with inflammation disease in early pool blood area but over the time cancer type slope more remarkably increased than inflammation disease. SUV-DC was similar to TAC pattern. In the result of Patlak analysis, In time activity curve of aorta, even though inflammation disease showed higher blood activity than cancer, at first as time went by, blood activity of inflammation disease became the lowest. However, in time activity curve of tissue, cancer had the highest uptake and inflammation disease was in the middle. Conclusion: Through the examination, TAC and SUV-DC could approached the results that lung cancer type and inflammation disease type has it's own difference shape patterns. Also, it has outstanding differentiation between cancer type and inflammation in Patlak and MRGlu analysis. Through these analysis methods, it will helpful to separation lung disease.

  • PDF

Efficient Application of Westgard Multi-Rules and Quality Control Implementation Improvement (Westgard Multi-Rules의 효율적 적용과 조치사항의 개선)

  • Jung, Heung Soo;Oh, Youn Jung;Bae, Jin Soo;Baek, Jin Young;Hwang, Bo ra;Shin, Yong Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.60-64
    • /
    • 2017
  • Purpose Westgard multi-rules application based on test quality improvement and commercialized international standard has been widely used in quality control. However, it is difficult to applicate the Westgard multi-rules in nuclear medicine in vitro tests due to the larger sample sizes and the simultaneous measurement of quality control material and patient sample. This study investigated the usefulness of Westgard multi-rules application in nuclear medicine in vitro tests. Materials and Methods A total of 282 systematic error multi-rules (22s, 101s) recorded in the samsung medical center computer system from January 2013 to June 2016 along with 117 cases of corrective measure record was analyzed. The Quality control implementation is recorded in Hospital information system were divided into 4 high-level areas including quality control material error, experimental procedural error, Kit lot number management error, and others. To prevent quality control material error, the existing method that each staff used their own method was changed. The staff who in charge of managing the quality control material was designated and daily consumption amount of every test was strictly controlled by one person. To prevent other errors, every test step was standardized so that the entire test procedures are identically implemented. Results The total quality control implementation was 117 cases; As a result, 62 quality control material errors were 62 cases, experimental process errors were 24 cases, Kit lot number control errors were 18 cases, and other errors were 13 cases. The quality control material error was corrected and could be used fresh materials within 2 days after thawing. The cases of systemic error were decreased to causes as quality control material error. The quality control materials were reduced above 10 vials to a monthly average. In addition, these errors of experimental processing and Kit lot number were improved by test standardization. Consequently, the cases of 101s and 22s in systematic error rules decreased at least 2 cases to a monthly average. Conclusion To confirm of systematic error through multi-rules application quickly, it is necessary to base on management of the QC material, target values and standard deviation. Moreover, in the event of a systematic error, it was found important to record measures based on test cause analysis. The experiment results are expected to contribute to internal quality control improvement and prompt and accurate result reporting through error recording and causal analysis based on Westgard multi-rules analysis.

  • PDF