• Title/Summary/Keyword: 표준평균범위

Search Result 364, Processing Time 0.217 seconds

Determination of Sodium Alginate in Processed Food Products Distributed in Korea

  • Yang, Hyo-Jin;Seo, Eunbin;Yun, Choong-In;Kim, Young-Jun
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.6
    • /
    • pp.474-480
    • /
    • 2021
  • Sodium alginate is the sodium salt of alginic acid, commonly used as a food additive for stabilizing, thickening, and emulsifying properties. A relatively simple and universal analysis method is used to study sodium alginate due to the complex pretreatment process and extended analysis time required during the quantitative method. As for the equipment, HPLC-UVD and Unison US-Phenyl column were used for analysis. For the pretreatment condition, a shaking apparatus was used for extraction at 150 rpm for 180 minutes at room temperature. The calibration curve made from the standard sodium alginate solution in 5 concentration ranges showed that the linearity (R2) is 0.9999 on average. LOD and LOQ showed 3.96 mg/kg and 12.0 mg/kg, respectively. Furthermore, the average intraday and inter-day accuracy (%) and precision (RSD%) were 98.47-103.74% and 1.69-3.08% for seaweed jelly noodle samples and 99.95-105.76% and 0.59-3.63% for sherbet samples, respectively. The relative uncertainty value was appropriate for the CODEX standard with 1.5-7.9%. To evaluate the applicability of the method developed in this study, the sodium alginate concentrations of 103 products were quantified. The result showed that the detection rate is highest from starch vermicelli and instant fried noodles to sugar processed products.

Noise Measurement by Percentage of Effective Linear Attenuation Coefficient of Water in CT Image of AAPM CT Performance Phantom (AAPM CT 성능 팬텀의 CT영상에서 물 유효선감쇠계수의 백분율에 의한 노이즈 측정)

  • Jong-Eon, Kim;Sang-Hun, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.771-778
    • /
    • 2022
  • The purpose of this study is to present a method of measuring noise by the percentage of effective line attenuation coefficient of water that can be used for quality control of CT image noise using AAPM CT performance phantom in clinical practice. In the CT images obtained by scanning the AAPM CT performance phantom with a 120 kVp CT X-ray beam, the mean CT number was measured for each pin and water in the CT number linearity insert part. The effective energy was determined as the photon energy with the largest correlation coefficient from the correlation coefficients of the linear regression analysis of the measured mean CT number for each pin and water and the linear attenuation coefficient for each photon energy. And for water and acrylic, the contrast scale was calculated as 0.000188 cm-1 · HU-1 from the measured mean CT number and effective line attenuation coefficient. Using the calculated contrast scale, the effective line attenuation coefficient of water, and the standard deviation measured in the water of the alignment pin part of the AAPM CT performance phantom, The noise measurement value by the percentage of effective line attenuation coefficient of water obtained 0.31 ~ 0.52% in the range of 100 ~ 300 mAs.

Characteristics of Total Carbon and Total Organic Carbon Using Elemental Analyzer in Hyung-Do Intertidal Zone Sediments (원소분석기를 이용한 형도 퇴적물의 총탄소 및 총유기탄소 특성)

  • Lee, Jun-Ho;Park, Kap-Song;Woo, Han-Jun
    • Economic and Environmental Geology
    • /
    • v.45 no.6
    • /
    • pp.673-684
    • /
    • 2012
  • Quantitative understanding of total carbon, total inorganic carbon and total organic carbon contained in ocean sediments is a basic data for interpretation of oceanic sediment environments. Elemental analyzer(EA) is frequently used for the analysis of carbon contents in inland soils and ocean sediments. Carbon and nitrogen contents of the soil reference material analyzed by an EA were 2.30% and 0.21% with standard deviations of 0.02 and 0.01, respectively. Relative standard deviations were 0.01 and 0.06, respectively, representing a high precision. Regression analysis of TOC and TC analysis results for the samples with TOC of less than 2.0% for the site in Hyung-Do showed a linear relationship with a slope of 0.9743($R^2$=0.9989, n=38), and the results of a relationship regression analysis between total organic carbon contents less than 0.5% and average grain size except for two samples showed a linear relationship with a slope of 0.0444($R^2$=0.6937 n=36). TOC contents of surface sediments were in the ranges of 0.10~1.67%(Average $0.26{\pm}0.37%$) with TOC values of 1.67% at S02 sampling site, 1.13% at S07 sampling site, and less than 1.00% at remaining sites. In the case of PC 01 core sediments, TOC showed the highest value of 0.20% near 70 cm. In the case of PC 02 core sediments, the highest value of 0.24% was indicated near 60 cm. The analysis method of organic carbon obtained from Hyung-Do Intertidal zone sediment sample results may be considered applicable to an organic carbon analysis for ocean sediments and useful for organic carbon analysis experiments of ocean sediments with a reduction in time required for the analysis and a high precision coupled with a high accuracy.

Evaluation of Puretone Threshold Using Periodic Health Examination Data on Noise-exposed Workers in Korea (소음 특수건강진단 자료를 이용한 순음청력검사 평가)

  • Kim, Yang-Ho;Choi, Jung-Keun;Park, Jung-Sun;Moon, Young-Han;Kim, Kyoo-Sang
    • Journal of Preventive Medicine and Public Health
    • /
    • v.32 no.1
    • /
    • pp.30-39
    • /
    • 1999
  • Objectives. This study was carried out to evaluate hearing impairment judgement and to investigate the differences in various diagnostic criteria for noise-induced hearing loss (NIHL) among workers who required for close observation (C). Methods. Out of 731,029 workers who had taken the specific periodic health examination in 1994, we used the audiometric data on 37,999 workers (C) eliminating the employees who had previous otologic problems. Many investigators have being using different criteria for the evaluation of hearing impairment. In this study, we used the criteria of early (1989-1994), current, compensation for NIHL in Korea, 2-, 3-, 4-divided classification and hearing loss at 4,000 Hz and compared the evaluation results. Results. The prevalences of C and workers who had occupational disease $(D_1)$ diagnosed for NIHL were 11.1 % and 0.44 %. There were significant difference in the prevalences of C and $D_1$, depending on different province of Korea. Pure tone averages (PTAs) were not appropriately applied in their evaluation 97% of workers whom we studied on were below the level of mild hearing loss judged by ISO standard. However, there were wide variations in the prevalence rate of mild hearing loss by diagnostic criteria. Thus, there were different judgements in determining the degree of NIHL depending on which diagnostic criteria were utilized. PTAs were found 20.54 (Rt) and 20.74 (Lt) when the method of 3-divided classification was applied for audiometric data. The degree of hearing impairment of the left ear was more severe than that of right ear. The prevalence of normal hearing threshold below 20 dB was 75.4% and the range of difference in both ear was below 10 dB. Right sided hearing threshold levels were 21.08 dB (500 Hz), 18.44 dB (1,000 Hz), 22.09 (2,000 Hz) and 52.36 dB (4,000 Hz). There was typical high frequency loss (C5-dip at 4,000 Hz) above 30 - 40 dB in normal hearing level. The increasing trend in hearing threshold level was gradually decreased by the increase of PTAs. The difference between PTAs and threshold at 4,000 Hz was about 10 dB. Conclusions. We could found that PTAs in the previous examination were not appropriately evaluated. This study revealed that they did not use unique criteria for managing the workers of NIHL. For the prevention of NIHL, it was found that the quality control on diagnosis and comprehensive management program were required, especially for those of hearing loss (C).

  • PDF

UBVI CCD Photometry of NGC 7790 (NGC 7790의 UBVI CCD 측광)

  • Choi, Dong Yeol;Kim, Hee Soo;Lim, Beomdu;Sung, Hwankyung
    • Journal of the Korean earth science society
    • /
    • v.36 no.7
    • /
    • pp.661-673
    • /
    • 2015
  • UBVI CCD photometry of the intermediate age open cluster NGC 7790 has been obtained using AZT-22 1.5 m telescope (f/7.74) at the Maidanak Astronomical Observatory in Uzbekistan. NGC 7790 contains three ${\delta}$ Cep variable stars including CEa Cas, CEb Cas, and CF Cas. PSF photometry was carried out using IRAF/DAOPHOT for all observations. The total number of stars observed both in V and I filter was 1008 and the limiting magnitude was $V{\approx}22$. To determine atmospheric extinction coefficients and photometric zero points, many blue and red standard stars as well as the standard stars in the celestial equator under various airmass were observed. Photometric data were transformed into the standard Johnson-Cousins' UBVI standard system. From the analysis of UBVI color-magnitude diagram and color-color diagram, the color excess in V and I filter [$E(B-V)=0.58{\pm}0.02$], the selective extinction ratio in V and I filter [$R_V{\equiv}A_V/E(B-V)=3.02{\pm}0.09$] and distance modulus ($V_0-M_V=12.65{\pm}0.10$) of the cluster were determined. The age of the cluster was estimated to be log $age=8.05{\pm}0.05$ [yr] based on the position of these three Cepheid variables in the color-magnitude diagram, the isochrone of the Geneva group ($Ekstr{\ddot{o}}m$ et al., 2012-Z=0.019), and the isochrone of the Padova group (Bressan et al., 2012-Z=0.014) were used to compare each other. Of them, the Geneva models that considered stellar rotation well described the position of ${\delta}$ Cepheid variables in the blue loop. Although they were well consistent with standard period-luminosity relation of ${\delta}$ Cepheid variables, three Cepheid variables in NGC 7790 were, on average, brighter by about 0.5 mag than the absolute magnitude estimated from the mean period-luminosity relation at a given period.

Use of Real-Time PCR and Internal Standard Addition Method for Identifying Mixed Ratio of Chicken Meat in Sausages (Real-Time PCR과 Internal Standard Addition법을 이용한 돼지고기 소시지에 혼합된 닭고기의 정량)

  • Lee, Namrye;Joo, Jae-Young;Yeo, Yong-Heon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.9
    • /
    • pp.1097-1105
    • /
    • 2017
  • This study examined how much chicken meat was in sausage made with pork. Both real-time polymerase chain reaction (PCR) and internal standard addition were used. Fifty ng of chicken DNA was added to the sausages as an internal standard. The addition of standard DNA increased the amplification efficiency of PCR and confirmed the possibility of quantitative analysis. A QIAamp DNA Micro Kit was used to improve the DNA recovery and amplification efficiency. The density of template DNA and primer were suitable for $3.0{\sim}5.0{\mu}L$ and $0.5{\mu}L$, respectively. Each DNA of pig and chicken was diluted in 10-fold from steps 50 ng to 0.05 ng. The detection limit of both pig and chicken meat was more than 0.05 ng and the correlation coefficient of the standard curve was at least 0.98. The result of the quantitative analysis after heat treatment of 3 samples of pigs and chickens mixed at 70:30 showed a 5.7% difference (64.3:35.7) between the expected value and measured value. The quantitative value was changed by affecting the DNA according to the heat treatment ($70^{\circ}C$, 10 min). An analysis of the pork and chicken content in sausages showed that it was difficult to detect chicken meat and the quantitative value of DNA according to the Ct value was very low. On the other hand, when adding standard material (50 ng of chicken DNA) to the sausages, the Ct value decreased gradually with increasing chicken mixing ratio. Thus, the mixing ratio of chicken in sausages could be estimated.

Development of NCS Based Vocational Curriculum Model for the Practical and Creative Human Respirces (실전 창의형 인재 양성을 위한 NCS 기반 직업교육과정의 모형 개발)

  • Kim, Dong-Yeon;Kim, Jinsoo
    • 대한공업교육학회지
    • /
    • v.39 no.2
    • /
    • pp.101-121
    • /
    • 2014
  • The study aims to develop the NCS based vocational curriculum model for the practical and creative human resources. For effectiveness of the study, the study consists of literature studies of both domestic and international, contents analysis, case study, expert(9samples) consultation and review, and in-depth-interview of the three advisory members. The validity of the developed model is analyzed through mean, standard deviation and contents validity ratio(CVR). The main results of the model development in our study are as follow. First, our NCS based vocational curriculum model for the practical and creative human resources is developed with the analyses of NCS development manuals, training standard utilization and training curriculum organization manuals, NCS learning module development manual and case studies, NCS research report, NCS based curriculum pilot development resources directed toward the high schools and vocational school as well as the domestic and international literature study on career training model like NCS. Second, based on the findings of our analysis in combination with the findings from the consultations with the expert and advisory committee, total 19 sub-factors of each step and domain are extracted. The sub-factors of domain in step 1 are the competency unit, definition of competency unit, competency unit element, performance criteria, range of variable, guide of assessment, key competency; in step 2, they are subject title, subject objectives, chapter title, chapter objectives, pedagogical methods, assessment methods and basic job competence; and in step 2, they are NCS based subject matrix table, NCS based subject profile, NCS based job training curriculum table, NCS based subjects organization flowchart, NCS based job training operation plan. Third, the final model including step 3 NCS based subject profile are developed in association with the linked organizational sub-factors of step 1 and step 2. Forth, the validity tests for the final model by the step and domain yield the mean 4.67, CVR value 1.00, indicating the superior validity. Also, the means of each sub-factors are all over 4.33 with the CVR value 1.00, indicating the high validity as well. The means of the associated organizations within the model are also over 4.33 with the CVR value of 1.00. Standard deviations are all .50 or lower which are small. Fifth, based on the validity test results and the in-depth-interview of the expert and advisory committee, the model is adjusted complemented to establish final model of the NCS based vocational curriculum for the practical and creative human resources.

Establishment of Reference Value of Insulin Using the Statistical Analysis (통계적 분석을 통한 Insulin의 정상 참고치 설정)

  • Kim, Whe-Jung;Yoon, Pil-Young;Shin, Young-Goon;Yoo, Seon-Hee;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.143-146
    • /
    • 2010
  • Purpose: Insulin is involved in carbohydrate metabolism and also it's very important because it increases storage of glycogen, synthesis of fatty acids, absorption of amino acid, synthesis of protein. Insulin is clinically useful when we evaluate fasting patients in hypoglycemia, classify and predict diabetes, assess the activity of ${\beta}$-cell, research insulin resistance. We are going to increase usability of insulin assay by establishing normal reference value according to statistical analysis. Material & Method: We selected 6,648 patients who visited asan health medical center from May to August in 2008. We set exclusion criteria as family of diabetes, diabetes medication, the past history of blood glucose rise, more than 100 mg/dL in normal fasting blood glucose, outside the scope of BMI 18.5~22.9 $kg/m^2$, and more than HbA1c 6.5%. We determine whether the subgroup is portioned as sex and age or not and establish normal reference value by conducting statistical analysis as Bayesian's method and Hoffman's method. Result: Portioning of subgroup as sex and age is not needed. By statistical analysis of Bayesian method, results 1.5-11.0 uIU/mL. By statistical analysis of Hoffman method, results 1.8~12.8 uIU/mL. Conclusion: We established 1.8~12.8 uIU/mL as Insulin normal reference value by Hoffman method. This is a similar value with reporting reference value 1.7~11.8 uIU/mL in kit. This will enhance the usability of insulin assay by establishing normal reference value.

  • PDF

Cadmium Extraction from Solutions by Solid-Phase and its Trace Determination (고상에서 용액으로 부터 카드뮴 추출과 잔유물 측정)

  • Ashrafi, F.;Attaran, A.M.;Kermani, N. Memar
    • Journal of the Korean Chemical Society
    • /
    • v.52 no.2
    • /
    • pp.133-139
    • /
    • 2008
  • A new sensitive and selective spectrophotometric method for determination of trace amounts of cadmium using a polyvinyl chloride membrane containing bis-(2-ethylhexyl)phthalate as a solid phase extraction medium was investigated. Bis-(2-ethylhexyl)phthalate has used as a plasticizer. Cd(II) in an aqueous solution was trapped on the membrane in the form of colorful Cd (II)-I- - MG complexes (which MG is malachite green) and the cadmium complex was concentrated in the membrane. The absorbance of the green membrane was measured at 629 nm using a spectrophotometer, and then, the concentration of the cadmium was calculated using a calibration curve, which expressed the relationship between the Cd(II) concentration and the membrane absorbance after coloring for 25 min. The calibration curve was linear in the range of 10-760 μgL-1 cadmium in the test solution. The detection limit based on the 3Sbl criterion was 1.8199 μgL-1 and the relative standard deviations (RSD) were less than 4 % (n=5). The proposed method has been successfully applied to the determination of trace amounts of cadmium in the Tadjan River water sample (Sari-Iran), and the mean value of 28.7 μgL-1 was obtained.

Time-to-Digital Converter Implemented in Field-Programmable Gate Array using a Multiphase Clock and Double State Measurements (Field Programmable Gate Array 기반 다중 클럭과 이중 상태 측정을 이용한 시간-디지털 변환기)

  • Jung, Hyun-Chul;Lim, Hansang
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.8
    • /
    • pp.156-164
    • /
    • 2014
  • In a delay line type of a time-to-digital converter implemented in Field Programmable Gate Array, the timing accuracy decreases for a longer carry chain. In this paper, we propose a structure that has a multi-phase clock and a state machine to check metastability; this would reduce the required length of the carry chain with the same time resolution. To reduce the errors caused by the time difference in the four delay lines associated with a four-phase clock, the proposed TDC generates a single input pulse from four phase clocks and uses a single delay line. Moreover, the state machine is designed to find the phase clock that is used to generate the single input pulse and determine the metastable state without a synchronizer. With the measurement range of 1 ms, the measured resolution was 22 ps, and the non-linearity was 25 ps.