• Title/Summary/Keyword: 표준평균범위

Search Result 363, Processing Time 0.029 seconds

Analysis of Spatial Variability for Infiltration Rate of Field Soil -I. Variogram (토양(土壤)중 물의 침투속도(浸透速度)의 공간변이성(空間變異性) 분석(分析) -I. Variogram)

  • Park, Chang-Seo;Kim, Jai-Joung;Cho, Seong-Jin
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.16 no.4
    • /
    • pp.305-310
    • /
    • 1983
  • Spatial variability of infiltration rates of 96 samples from Hwadong SiCL was studied by using geostatistical concepts. The measurement was made at the nodes of the regular grid consisting of 12 rows and 8 columns. Sample spacing within rows and columns was 3 and 2 meters, respectively. This study illustrated the use of variogram as a tool to identify the degree of dependency of the infiltration rate on the distance between pairs of measurements and how to take advantage of this dependency. Fractile diagram showed that the distribution of observation was approximately normal. The range of the variogram was about 7.4 meters. The minimum number of samples necessary to reproduce the results similar to the 96 measured values was 8 to 10. Coefficients of theoretical variogram function for computing kriged values and kriged varionces of nuogget effect, slope, and range were 0.444 cm/day, 0.003 cm/day, and 7.4 m, respectively.

  • PDF

Improvement Effects of Cement Grouting using Vibration Method through a Field Test (현장시험을 통한 시멘트 진동주입공법의 보강효과)

  • Han, Sanghyun;Yea, Geugweun;Kim, Hongyeon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.5
    • /
    • pp.23-29
    • /
    • 2014
  • So far, the grouting using pressure injection has been extensively used to avoid adverse effects such as soil disturbance. Whereas, the pressure injection to the limitations of the diffusion range, so that the kinks would last injection of cement particles by introducing a frequency oscillation effect improved injection method have been recently developed. In this study, a pilot test was performed to compare injection effects of the both methods. The injections using both methods were tested on the embankment which consists of core clay and weathered soil. Subsequently, the injected volume, SPT N values, in-situ permeability and electrical resistivity were measured to compare their effects. The vibration method showed more effective permeation comparing with the pressure method. Also, it showed more homogeneously improved ground than the existing method. For SPT results, the vibration method presented increase of mean N value as much as 17.4 % comparing with the conventional method. Higher electrical resistivity was presented in case of injecting with vibration method and it indicated the injection was extensively completed. Finally, it is expected that the economic feasibility will be improved by decrease of drilling spacing, when the existing method is replaced with vibration method.

Roles of the Specialized Education Recognized by Professional Panels (전문가 패널들이 인식하는 공업계고등학교의 전문교육 역할)

  • Oh, Seung-gyun
    • 대한공업교육학회지
    • /
    • v.33 no.1
    • /
    • pp.1-22
    • /
    • 2008
  • The purpose of this research is to clarify the elements of the function of the role of industrial high schools that its experts perceived. The content of this research is verify the function element required for the performance of the role of specialized education through content validity ratio(CVR). This research adopted the method of literature research and Delphi method, which is to collect and come to an agreement of the opinions of the 26 research panels. The first round is constructed by the semi-constructed questionnaire for the analysis of the opinions of the panels by inductive method. The second round is to categorize the result of the first one into 7 domains, and asked each category by Likert's 5 scale checklists, and statistically analyzed mean, medium, standard deviation, and quartile. The third round is to statistically analyze Mean, standard deviation, medium, and validity ratio(CVR) to reassure the opinions of the panels on the basis of the result of the first one. The categorized contents of the function required for the performance of the specialized education in this research is 'in-service visit and in-service training', 'licence acquiring education', 'employment counseling and job employment information', 'custom-made education connected with industry', 'career education' and 'enhancement of basic career competency'. The panels are divided into professors, teachers, professionals, and policy administrators, and they verified the validity rate of the function role and priority of emphasis. The result showed that the tendency of the education is converting from physical function-centered education to education of emotional attitude and competence of thought.

Comparative Analysis of Accuracy between Computerized Tomography and Cephalogram for 3-Dimensional Measurement of Maxillofacial Structure (악안면 3차원 계측시 컴퓨터 단층촬영과 두부 방사선 규격사진의 정확성 비교 분석)

  • Paek, Jong-Su;Song, Jae-Chul;Lee, Hee-Kyung
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.1
    • /
    • pp.123-137
    • /
    • 2001
  • Background: The purpose of this study is to evaluate the accuracy of measurements obtained from 3-dimensional computerized tomography and 3-dimensional cephalogram constructed by using the frontal and lateral cephalogram of six human dry skulls. Materials and Methods: After CT scans and each cephalograms were taken, 3-dimensional coordinates (X, Y, Z) of landmarks were obtained using computer programs. In this study, the accuracy of both methods were determined by means of 14 linear measurements compare with caliper measurements. Results: The standard deviation of landmarks of 3-dimensional CT and 3-dimensional cephalogram were 0.23 mm, and 0.30 mm in X axis, 0.27 mm and 0.25 mm in Y axis, and 0.27 mm and 0.31 mm in Z axis. In both methods, the standard deviation were less than 0.5 mm in all landmarks, and the most of landmarks showed less than 1 mm in range. Concerning the accuracy, the mean difference between 3-dimensional CT and manual measurements was 0.33 mm, and 1.13 mm between 3-dimensional cephalogram and manual measurements. The distance between RGo and LGo showed the largest difference (2.03 mm). There were highly significant, and large correlation with manual measurements in both methods (p<0.01). Conclusion: It is concluded that closeness of repeated measures to each skulls reveal the precision of both methods. Computerized tomography and cephalogram for 3-dimensional measurement of maxillofacial structure are equivalent in quality to caliper measurements.

  • PDF

Serum Angiotensin-Converting Enzyme Levels in Coal Worker's Pneumoconiosis (탄광부 진폐증환자의 Angiotensin-Converting Enzyme 활성치)

  • Kim, Kyung-Dong;Choi, Myung-Sook;Lee, Chae-Hoon;Kim, Chung-Sook;Bae, Eun-Kyung
    • Journal of Yeungnam Medical Science
    • /
    • v.6 no.1
    • /
    • pp.109-119
    • /
    • 1989
  • We measured fasting serum angiotensin -converting enzyme (SACE) in 100 healthy controls and 75 coal worker's pneumoconiosis (CWP) patients by a commercial kits($ACEcolor^{(R)}$, Fujirio Inc., Japan) and evaluated this manual method. The linear range extends to an activity of 80U/L. Precision on a commercial control serum (ACE control-$N^{(R)}$, Sigma Co.)with a mean value, of 9.47U/L yielded a within-run and between-run CVs are 5.6% (N=15) and 6.9% (N=14) respectively. SAVE in 75 CWP was $20.3{\pm}5.7U/L$ ($mean{\pm}s.d.$) ; higher than in healthy controls ($13.4{\pm}3.9U/L$, P<0.01). No correlation was found between SACE, sex, and age. The results suggest that the measurement of SACE and follow-up SACE in coal workers may be a useful diagnostic fools for CWP.

  • PDF

Effects of the Open Level of the Side Window on the Control of the Temperature and Relative Humidity in the Fog Cooling Greenhouse (포그냉방 온실에서 측창개폐수준이 온습도 제어에 미치는 영향)

  • Kim, Young-Bok;Sung, Hyun-Soo;Yun, Nam-Kyu;Lee, Si-Young;Hwang, Seung-Jae;Kim, Hyeon-Tae;Lee, Jang-Pyung
    • Journal of agriculture & life science
    • /
    • v.45 no.6
    • /
    • pp.265-278
    • /
    • 2011
  • Effects of the open level of the side window were studied to control the temperature and relative humidity in the fog cooling greenhouse. The greenhouse was cooled by air atomizing spray nozzles of the air and water two-fluid process. The control process includes the measuring of environmental variables, setting and coding of the water balance equations and heat balance in greenhouse, calculating of the roof window open and spray water, and operating of the motor and pump. The target temperature and relative humidity were set at $28^{\circ}C$, 75%, respectively. The three modes of the side window open level were 0%, 50% and 100%. The average dry bulb temperatures of the inside air were 28.2, 27.2 and $26.3^{\circ}C$, respectively and their standard deviation was ranged from $0.4^{\circ}C$to $0.8^{\circ}C$. Also the relative humidity of the 0% mode was the best controlled one with the average of 76.3% and the standard deviation of 2.1%.

Vertical Temperature Difference of Steel Box Girder Bridge Considering Asphalt Thickness of Concrete Deck (콘크리트 바닥판의 아스팔트 두께에 따른 강박스거더교의 상하 온도차)

  • Lee, Seong-Haeng
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.602-608
    • /
    • 2019
  • The purpose of this study was to calculate the temperature difference of the sectional elevation according to the asphalt thickness of the steel box girder bridge deck and provide data on the design basis accordingly. Asphalt thicknesses produced four steel box girder model specimens of 0mm, 50mm, 100m and 150mm. In each model, 17 to 23 temperature sensors were attached to upper concrete and steel box girders. Six temperature gauges were selected to compare the temperature difference with Euro codes. The maximum and lowest temperature were calculated at the reference atmospheric temperature of each model, and the temperature difference (slope) was calculated based on this calculation. Four models of temperature difference are presented at each model. The 0mm to 100mm temperature difference models showed a -0.9 to -1.5 degree lower temperature difference compared to the temperature difference of Euro codes at the top of the slab. Overall, the measured temperature difference was found to be between 5.45% and 8.33% compared to the Euro code. The standard error coefficient, which was calculated by multiplying the average temperature with the standard error, was calculated from a range of 2.50 to 2.51 times the average at the top and bottom. It is estimated that the proposed temperature difference model can be used as a basic data when calculating temperature difference criteria for bridges in Korea.

Jitter and Shimmer of the Deaf Voice (농자 음성의 주파수 변동율 및 진폭 변동율)

  • Ok-ran Jeong
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.7 no.1
    • /
    • pp.39-42
    • /
    • 1996
  • The present study analyed jitter and shimmer of the deaf in 4 different voicing conditions. Thirty-two male subjects and 27 female subjects participated in the study on a voluntary basis. The age ranged from 6 to 18 for male and 8 to 21 for female subjects. The subjects were either congenitally or prelingually deaf The four different voicing conditions included /a/ prolongation, counting, reading, and conversation. The experiment utilized CSL Visi-Pitch Model 6095(Kay Elemetrics Corp.) to sample and analyze the data. Both jitter and shimmer means were higher than the threshold values(normative data) reported. In addition, this investigation performed two separate 2-factor ANOVAs in order to determine if jitter and shimmer change as a function of gender and voicing condition. The results showed the following. First of all there was the gender effect on shimmer but not on jitter, in that male subjects 'shimmer was higher than females'. secondly, there was the voicing condition effect both on jitter and shimmer. /a/ prolongation and reading produced lower jitter than counting and conversation. /a/ prolongation produced lower shimmer than the remaining conditions. Finally, no interaction between gender and voicing condition existed.

  • PDF

Changes in Body Temperature of Piglets in a Day (자돈의 일중 체온변화에 관한 연구)

  • Yi, One-Hyeon;Jeong, Wang-Yong;Lee, Sang-Cheol;Lee, Sang-Rak
    • Journal of Animal Environmental Science
    • /
    • v.18 no.2
    • /
    • pp.91-94
    • /
    • 2012
  • This study was conducted to develop an algorithm for determination of abnormal body temperature in piglets through skin and core temperature database at normal condition. 5 piglets (mean BW : 46 kg) were employed for the experiment. They were adapted in the individual metabolism cage set at $22.5{\pm}2.0^{\circ}C$ of room temperature for 2 weeks before the measurement of body temperature. Ear, neck, head and subcutaneous neck temperature (as core temperature) of piglets were measured for every 1 minute during 30 consecutive days through 1mm k-type thermocouple wire and NI-devices (National Instruments Corporation, Austin, Texas, USA). Body temperature data were accumulated and integrated into the 1 day unit. Change of daily mean skin and core body temperatures in piglets were lowest at around 06:00, highest at around 14:00 and gradually decreased until the day after 06:00. Each skin temperatures were varied with the measuring site and largely depended on the room temperature changes. Established database of skin and core body temperature in piglets through this study can be applied to develop an algorithm for monitoring and determining the abnormal condition of animal by using radio frequency identification.

Analysis on the Change of Haed Loss Coefficients at Four-Way Square Combining Manhole (4방향 사각형 합류맨홀에서의 손실계수 변화분석)

  • Jo, Jun Beom;Yoon, Sei Eui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.176-176
    • /
    • 2017
  • 배수시설 내 맨홀에서의 과부하 흐름은 관거시설의 배수 능력을 저하시켜 우수의 역류로 인한 도시 침수피해의 가중 요인이 된다. 특히, 도시 유역 중 하류부의 저지대에서 주로 설치되는 합류 맨홀은 저지대 침수에 많은 영향을 미치므로 합류맨홀에서의 흐름특성 분석 및 유입유량 변화에 따른 손실계수의 변화에 관한 연구가 필요한 실정이다. 현재까지 중간맨홀, $90^{\circ}$ 접합맨홀 및 3방향(T형) 합류맨홀 등에 관한 연구는 지속적으로 수행되고 있으나 4방향 합류맨홀에 관한 연구는 기초적인 연구만 수행되고 있다. 4방향 합류맨홀은 세 개의 유입관과 한 개의 유출관으로 구성되어 있으므로 각 유입관의 유입유량 변화에 따라서 맨홀에서의 손실계수가 다양하게 변화된다. 이와 같은 유입유량 변화에 따른 맨홀 내 흐름특성 분석 및 손실계수 산정에 관한 연구는 국내에서는 전무한 실정이다. 그러므로 유입유량 변화에 따른 4방향 합류맨홀에서의 손실계수 변화특성의 분석이 필요하다. 본 연구에서는 4방향 사각형 합류맨홀에서 세방향에서 유입되는 각 유입유량의 유입비($Q_{in}/Q_{out}$)가 0.0~1.0으로 변화하는 조건에서 평균 손실계수를 산정하기 위하여 하수도시설기준(환경부, 2011)의 표준 1호 맨홀 및 연결관경을 1/5로 축소하여 수리실험 장치를 제작하였다. 유출유량은 $3{\ell}/sec$이고 각 유입관(주유입관 및 좌 우측면유입관)의 유입유량을 $0{\sim}3{\ell}/sec$까지 유입유량의 비율을 각각 10%씩 변화시키면서 수리실험을 실시하였다. 실험결과 주관거의 유입유량이 줄어들고 측면관거의 유입유량이 늘어나면서 손실계수가 상승하는 것으로 나타났으며, 한쪽 측면 관거에서만 유입유량이 들어오는 $90^{\circ}$ 접합맨홀의 형태에서 손실계수가 가장 크게 나타났으며, 유입유량 변화에 따른 4방향 합류맨홀에서의 손실계수의 범위는 0.5~1.7으로 산정되었다. 이는 과부하 4방향 사각형 합류맨홀에서는 측면 유입관에서의 유입유량의 증가에 따라 평균 손실계수 값이 크게 증가되는 것으로 판단된다. 이는 김정수(2010) 등이 산정한 $90^{\circ}$ 접합맨홀의 손실계수 및 중간맨홀의 손실계수와 유사하게 나타났으므로 전체적인 손실계수의 범위는 타당하다고 판단된다. 또한, Wang(1988) 등의 유사연구와의 유입유량 변화에 따른 손실계수의 변화 경향도 유사하였다. 따라서 본 연구에서 산정된 유입유량 변화 조건이 고려된 4방향 합류맨홀에서의 손실계수는 XP-SWMM 등의 부정류 흐름이 고려된 도시지역의 침수해석이나 관거 배수능력 평가에 활용이 가능할 것으로 판단된다.

  • PDF