• Title/Summary/Keyword: 표준측정법

Search Result 869, Processing Time 0.026 seconds

Rotational Prism Stitching Interferometer for High-resolution Surface Testing (고해상도 표면 측정을 위한 회전 프리즘 정합 간섭계)

  • In-Ung Song;Woo-Sung Kwon;Hagyong Khim;Yun-Woo Lee;Jong Ung Lee;Ho-Soon Yang
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.3
    • /
    • pp.117-123
    • /
    • 2023
  • The size of an optical surface can significantly affect the performance of an optical system, and high spatial frequency errors have a greater impact. Therefore, it is crucial to measure the surface figure error with high frequency. To address this, a new method called rotational prism stitching interferometer (RPSI) is proposed in this study. The RPSI is a type of stitching interferometer that enhances spatial resolution, but it differs from conventional stitching interferometers in that it does not require the movement of either the mirror tested or the interferometer itself to obtain sub-aperture interferograms. Instead, the RPSI uses a beam expander and a rotating Dove prism to select particular sub-apertures from the entire aperture. These sub-apertures are then stitched together to obtain a full-aperture result proportional to the square of the beam expander's magnification. The RPSI's effectiveness was demonstrated by measuring a 40 mm diameter spherical mirror using a three-magnification beam expander and comparing the results with those obtained from a commercial interferometer. The RPSI achieved surface testing results with nine times higher sampling density than the interferometer alone, with a small difference of approximately 1 nm RMS.

Case study on the Verification of "Essential Patent to Standard" using Document Similarity anal용yzed by Morphological Characteristics (형태학적 특성 기반의 유사문헌 검증기법을 이용한 표준특허 사례연구)

  • An, Jeong-Eun;Yoon, Jong-Min
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2010.06c
    • /
    • pp.191-196
    • /
    • 2010
  • 표준특허란 표준문서의 규격을 기술적으로 구현하는 과정에서 필수적으로 적용해야 하는 특허로서, 최근 선진국은 "R&D-특허-표준화의 연계"를 강화하고 있고 글로벌 기업 또한 표준과 연계한 특허 획득에 주력하고 있다. 우리나라 또한 기술선점, 시장지배력 및 경제적 파급효과 등의 표준특허 확보의 중요성을 인식하고 있고, 정부와 정부부처의 산하 연구기관을 중심으로 표준특허 관련 법 제도 등의 관련연구가 진행되고 있다. 그러나 표준특허 분석결과만이 연구결과로 공개되고 있을 뿐, 실제로 표준특허 선별을 위한 정형화된 기법은 전무한 상태이며 분석방법론 관련연구 또한 매우 미미한 상태이다. 따라서 본 논문은 형태학적 특성에 기반을 두어 표준과 특허문서 간 유사도를 측정하고, 측정된 유사도를 분석하여 신뢰성 있게 표준특허를 선별하는 방법을 제안하고 그 적용사례를 분석한다.

  • PDF

Uncertainty Assessment of Stationary ADCP Discharge Measurement using Standardized GUM Framework (GUM 표준안을 이용한 고정 측정 방식 ADCP의 유량 측정 불확도 평가)

  • Kim, Dongsu;Kim, Jongmin;Kim, Seojun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.102-102
    • /
    • 2016
  • 일반적으로 수자원분야에서 사용되는 기초 자료 중 하나인 유량측정 성과는 설계홍수량 산정, 지점의 수위-유량 관계곡선식 산정 등 유역의 이 치수를 위한 설계나 장 단기 계획을 수립하기 위한 기초자료로서 사용되어지고 있으며, 2차원 및 3차원 수치해석을 위한 입력 자료로 사용되고 있다. 유량측정의 성과는 이렇듯 다양한 방면으로 활용되어지고 있는 반면 현재 국내에서는 측정의 성과에 대한 신뢰성을 나타낼 수 있는 지표가 제시되고 있지 않은 상황이다. ISO(International Organization for Standardization) 및 BIPM, IFCC 등 6개 기구는 공동으로 측정 불확도 산정 지침서(GUM, Guide to the expression of Uncertainty in Measurement, 1993)을 제시하였고, 최근 WMO에서는 GUM 표준안을 하천 유량 측정 불확도 산정방법으로 공인하고 있다(JCGM 100, 2008). 이에 따라 본 연구에서는 최근 유량 측정에 활발하게 사용되고 있는 ADCP의 유량 측정 성과에 대한 불확도를 GUM 표준안 기반으로 평가하고자 한다. ADCP의 측정 방법은 고정측정 방식이고, 유속-면적법으로 계산된 유량에 대한 측정 불확도를 평가하였다. 실험은 실규모에서 유량을 제어할 수 있는 건설기술연구원 하천실험센터에서 수행되었고, 사용된 유속 측정 장비는 SonTek사의 micro-ADV와 ADCP M9을 사용하였으며, ADV로 측정된 결과를 참값으로 가정한 후 실험 및 분석을 수행하였다. GUM 표준안 기반의 불확도 평가를 위해 사용된 관계식 및 불확도 요인들은 선행 연구들을 기반으로 하되, 본 실험을 통해 분석된 수치로 변경하여 최종적인 ADCP 유량 산정 불확도를 평가하였다. 본 연구에서는 고정측정 방식 ADCP의 유량 측정 결과를 GUM 표준안에 적용하여 불확도를 평가하였으며, 추가적인 연구를 진행하여 일반적으로 사용하고 있는 이동측정 방식 ADCP의 유량 측정 결과에 대한 불확도를 평가할 수 있을 것으로 기대되며, 이러한 결과는 설계 홍수량 산정이나 수위-유량 관계 곡선식 산정 등 다양한 분야에 적용할 수 있을 것으로 사료된다.

  • PDF

Robot work measurement based on selective analysis method (선택적 분석기법에 기초한 로봇 작업측정)

  • 권규식;김진선
    • Proceedings of the ESK Conference
    • /
    • 1997.04a
    • /
    • pp.50-55
    • /
    • 1997
  • 본 연구에서는 일반적으로 생산 현장에서의 로봇 작업이 "getting"과 "putting"의 동작으로 구서 되는 것에 기초하여 이들 동작을 분류. 표준화하여 2단계의 단위동작 (GET, PUT) 별로 여러 가지의 모듈을 설정하고, 동작거리별로 표준시간을 산출하는 기법을 다룬다. 즉 기존의 로봇 작업측정법이 작업을 기존동작으로 분석하는 것과는 다르게 시간의 변동요인인 모듈의 Type과 동작거리의 Case를 선택함으로써 표준시간을 설정한다.를 선택함으로써 표준시간을 설정한다.

  • PDF

중소기업의 경쟁력 강화를 위한 공장 혁신 프로그램 - 4. 작업관리

  • 유태수
    • The Optical Journal
    • /
    • v.13 no.2 s.72
    • /
    • pp.23-27
    • /
    • 2001
  • 이번 호는 작업관리르 다룬다. 작업 관리는 작업 룰(규율) 관리, 준비 교체 작업 관리, 작업 개선관리의 세 시스템으로 대별할 수 있다. 이와 함께 소정의 표준작업조건 아래서 일정한 작업방법에 따라서 숙련된 작업자가 정상적인 속도로 작업을 수행하는 데 필요한 시간인 '표준 작업시간'을 이해하고, 표준 작업시간 측정방법 가운데 Stop Watch법을 자세히 알아보기로 하자.

  • PDF

Comparisons of sample preparation (acid digestion and microwave digestion) and measurement (inductively coupled plasma mass spectrometry and graphite furnace atomic absorption spectrometry) in the determination of bone lead (골중납 측정의 시료 전처리 (산분해법과 마이크로웨이브 분해법)와 측정 방법 (유도결합 플라즈마 질량분석법과 흑연로 원자 흡수 분광 광도법)의 비교)

  • Yoon, Chungsik;Choi, Inja;Park, Sungkyun;Kim, Rokho
    • Analytical Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.152-158
    • /
    • 2003
  • This study was conducted to evaluate two sample digestion procedures and instrumental determination parameters for analysis of lead in bone. Amputated human legs were treated by acid digestion or microwave dissolution prior to spectrometric analysis. Inductively coupled plasma mass spectrometry (ICP-MS) and graphite furnace atomic absorption spectrometry (GF-AAS) were used for determining bone lead levels. Recovery efficiencies using standard reference material from acid digestion measured by ICP-MS were in good agreement with those of the certified value, but in cases of acid digestion by GF-AAS and microwave digestion by both two methods, recovery underestimated and overestimated, respectively. For the bone samples, the lead concentrations obtained by ICP-MS after acid digestionwere in good agreement with those by GF-AAS (correlation coefficient = 0.983), but GF-AAS gave systematically higher values than ICP-MS. While a good agreement between two analytical methods after microwave digestion was also obtained (correlation coefficient = 0.950), bone lead concentrations from microwave were relatively higher than those from acid digestion. In conclusion, the use of the simple nitric acid digestion procedure at an ambient temperature coupled to ICP-MS seems to be efficient for the determination of lead in bone in consideration for both the convenience and validity.

Deformation Measurement of the Slope Using Free-Net Bundle Adjustment (Free-Net 광속조정법을 이용한 사면의 변형측정)

  • Lee, Jin-Duk;Lee, Ho-Chan;So, Jae-Kyoung
    • 한국지형공간정보학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.155-160
    • /
    • 2004
  • 근거리 디지털 영상을 이용하여 도로 사면의 3차원 변형을 효율적으로 측정하고자 하였다. 광속조정법(bundle adjustment)에 근거한 사진삼각측량 방법을 적용함에 있어서 종래의 표준적인 기법과 Free-net 기법으로 각각 처리하여 사면의 약 1/35000의 정확도로 3차원 측정과 변형량을 도출하였으며, 토털스테이션에 의해 측정한 결과와 비교하였다. 연구를 통하여 Free-net 기법을 적용함으로써 복잡한 산업현장에서 기존의 측지학적 기준점측량을 행하지 않고도 신속하고 정확한 측정을 기대할 수 있음을 확인할 수 있었다.

  • PDF

Preparation of Standard Phosphatidylcholine Hydroperoxide for Chemiluminescence-HPLC Assay (화학발광고속액체크로마토그래피법에 대한 표준물질인 포스파티딜콜린 하이드로퍼옥사이드의 조제)

  • Song, Jin Hyang;Choi, Hong Yeob;Park, Dong Ki
    • Analytical Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.474-477
    • /
    • 1998
  • A simple and rapid method for preparation of standard phosphatidylcholine hydroperoxide (PCOOH) in chemiluminescence-HPLC assay (CL-HPLC) was developed using the rose bengal dependent spectrofluorometric oxidation. The concentration of obtained PCOOH was determined by FOX (ferrous oxidation-xylenol orange) assay and then subjected to a CL-HPLC system.

  • PDF

Differences in Nutrient Intakes Analysed by Using Food Frequency and Recall Method (빈도법과 회상법에 의한 영양소 섭취 평가의 차이)

  • 김영옥
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.24 no.6
    • /
    • pp.887-891
    • /
    • 1995
  • Nutrient intake data collected by both dietary methods of the 24 hour recall method and the food frequency method from 538 middle school students were analysed to investigate any measurement errors occuring while using these methods. Measurement errors were observed both in terms of differences of average intake and consistancy from the two sources of data used. Wilcoxon signed ranks test was used to test the differences between the two average intakes and Speraman's rank order correlation coefficient was used to test consistancy. As a result, average intake value estimated from the food frequency method tended to be higher than that from the 24 hour recall method. The degree of overestimation varies from one nutrient to another. For instance, carotene showed not only the most significant differences in average intake but also showed the most incoisistancies between the two sets of data. This may imply the validity of nutrient intake as derived from different dietary survey methods varied from one nutrient to another, therefore the selection of dietary survey methods has to be made more cautiously in the case of certainnutrients.

  • PDF

Determination of bromine in 1000 ㎍/g Cl standard solution by ID-ICPMS (동위원소희석 질량분석법에 의한 1000 ㎍/g 염소 표준용액 중 브롬 불순물 분석)

  • Park, Chang Joon;Suh, Jung Kee;Song, Hyun Joo;Lee, Dong Soo
    • Analytical Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.1-8
    • /
    • 2006
  • The isotope dilution method was used for the determination of Br impurity in $1000{\mu}g/g$ Cl standard solution. Since relatively pure KCl salt was used for the preparation of the Cl standard solution, the Br impurity determination suffers from both spectral and non-spectral interferences due to the presence of a large amount of K and Cl matrices. AG2-X8 anion-exchange resin was employed to separate the Br analyte from the matrices, and RF power was raised to 1500 W and nebulizer gas flow rate was lowered to 0.77 L/min to reduce background from the $ArArH^+$ molecular ions. The Br impurity in the $1000{\mu}g/g$ Cl standard solution was determined to be 43.7 ng/g with the standard addition method. The analytical result was in good agreement with 41.2 ng/g (RSD 1.6%) determined by the isotope dilution method to lower uncertainty from poor reproducibility of the anion-exchange process.