Browse > Article
http://dx.doi.org/10.5806/AST.2006.19.1.001

Determination of bromine in 1000 ㎍/g Cl standard solution by ID-ICPMS  

Park, Chang Joon (Division of Chemical Metrology and Material Evaluation, Korea Research Institute of Standards and Science)
Suh, Jung Kee (Division of Chemical Metrology and Material Evaluation, Korea Research Institute of Standards and Science)
Song, Hyun Joo (Department of Chemistry, Yonsei University)
Lee, Dong Soo (Department of Chemistry, Yonsei University)
Publication Information
Analytical Science and Technology / v.19, no.1, 2006 , pp. 1-8 More about this Journal
Abstract
The isotope dilution method was used for the determination of Br impurity in $1000{\mu}g/g$ Cl standard solution. Since relatively pure KCl salt was used for the preparation of the Cl standard solution, the Br impurity determination suffers from both spectral and non-spectral interferences due to the presence of a large amount of K and Cl matrices. AG2-X8 anion-exchange resin was employed to separate the Br analyte from the matrices, and RF power was raised to 1500 W and nebulizer gas flow rate was lowered to 0.77 L/min to reduce background from the $ArArH^+$ molecular ions. The Br impurity in the $1000{\mu}g/g$ Cl standard solution was determined to be 43.7 ng/g with the standard addition method. The analytical result was in good agreement with 41.2 ng/g (RSD 1.6%) determined by the isotope dilution method to lower uncertainty from poor reproducibility of the anion-exchange process.
Keywords
Br impurity; Cl standard solution; anion-exchange; standard addition; isotope dilution;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 A. Seubert and J. Godfrey, Application Note, December, 18(2001)
2 A. Dudoit and S. A. Pergantis, J. Anal. At, Spectrom., 16, 575(2001)   DOI
3 A. R. Elwaer, C. W. McLeod and K. C. Thompson, Analyst, 123, 981(1998)   DOI   ScienceOn
4 M. Rose, P. Miller, M. Baxter, G. Appleton, H. Crews and M. Croasdale, J. Environ. Monit., 3, 361(2001)   DOI
5 X. Hou, C. Chai, Q. Qian, C. Li and K. Wang, Fresenius J. Anal Chem, 357, 106(1997)
6 A. Seubert, G. Schminke, M. Nowak, W. Ahrer and W. Buchberger, Journal of Chromatography A, 884, 191(2000)   DOI   ScienceOn