• Title/Summary/Keyword: 표준사용량

Search Result 106, Processing Time 0.037 seconds

Assessing the accuracy of electric energy monitoring system (전기 에너지 모니터링 시스템의 신뢰성 평가 방안)

  • You, Young Hag;Leem, Choon Seong;Choi, Dae Soon
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.9
    • /
    • pp.53-60
    • /
    • 2018
  • In order to manage energy efficiency by analyzing the amount of energy, it would determine the nature of the factors involved in the energy utilization. Therefore, accurate measurement of the energy consumption data is an important factor in the energy management. In this study, we are aware of the importance of the data measurement, and proposes the accuracy assessment of electric energy monitoring system. According to conventional statistical methods it is proceeded as follows; i)the measurement error value would be determined by a random variable, ii) setting the confidence interval to consider the distribution of the statistic and determines the confidence level of the measurement accuracy. And using the t-distribution CDF is used to facilitate even small sample data.

Definition and application of the human-modified hydrological drought : a case study of Han River basin (인위적 용수관리를 고려한 수문학적 가뭄의 정의 및 적용성 검토 : 한강유역을 중심으로)

  • Shin, Ji Yae;Moon, Jang-won;Kim, Min-ji;Kim, Tae-Woong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.331-331
    • /
    • 2021
  • 수문학적 가뭄의 판단은 유출량과 저수지 수위 등을 비롯한 다양한 수문자료를 활용하여 가능하다. 가뭄판단을 위한 유량 자료로는 수위관측소 관측 유량, 유출모형을 통한 모의 유량 자료가 주로 활용된다. 최근에는 관측 유량 기반의 수문학적 가뭄 판단은 인위적인 용수 배분이 고려된 것이기 때문에 인간이 만든 수문학적 가뭄(Human-modified hydrological drought, 인위적 수문학적 가뭄)으로, 모의 유량 기반의 수문학적 가뭄 판단은 자연적인 수문과정이 반영된 자연유량을 활용한 것이기 때문에 기후영향 수문학적 가뭄(Climate-induced hydrological drought)이란 정의된다. 우리나라의 경우, 홍수기에 저류된 저수량을 비홍수기 동안, 특히 용수사용량이 많은 봄철 농번기에 활용하는 것이 수자원 관리의 기본방향이다. 따라서 우리가 직면하는 수문학적 가뭄은 대부분 댐 및 저류지에서의 용수 사용량 조절에 따라 영향을 받기 때문에, 기상인자가 직접적인 원인으로 작용되는 가뭄과는 다르다. 본 연구에서는 관측 유량과 자연유량 자료를 활용하여 위에서 정의된 두 종류의 수문학적 가뭄에 대하여 비교하고, 실제 발생되었던 가뭄 피해 정보와의 일치정도를 검토하였다. 가뭄의 판단은 각각의 가뭄지수를 표준유출량지수(Standardized Runoff Index, SRI)에 적용하며, 수정 Mann-Kendall 검증으로 두 지수들의 경향성을 비교하였다. 장기간의 관측 자료를 보유하고 있는 한강유역 일부지역에 적용한 결과 두 종류의 가뭄지수 모두 뚜렷한 경향성은 없으며, 댐 상류지역에서의 두 종류의 가뭄특성은 유사하게 나왔다. 하지만, 댐 하류지역에서는 인위적 수문학적 가뭄이 기후영향 수문학적 가뭄보다 발생빈도는 적으나, 지속기간은 약 한달 정도 짧고, 가뭄심도는 약 5~20 % 정도 증가하는 강도가 센가뭄이 발생되는 경향이 있음이 확인되었다. 이는 인위적인 용수 관리로, 약한 규모의 가뭄은 감소되고 있으나 큰 규모의 가뭄은 그 영향이 더 큰 것으로 예상할 수 있다. 해당 결과를 바탕으로 효율적인 용수 관리에 통하여 약한 가뭄 뿐만 아니라 대형 가뭄을 대비하기 위한 지속적인 노력이 필요함을 확인 할 수 있었다. 장기간의 관측 유량의 자료의 한계로 많은 지역에는 적용이 어려우나 해당 연구를 통하여 국내에서도 수문학적 가뭄의 개념을 재정립하고, 용수 공급 개념을 기반으로 하는 수문학적 가뭄 지수의 개발에 활용 가능할 것이다.

  • PDF

Quality Evaluation and Mix Proportion of Antiwashout Underwater Concrete with Mineral Admixture (광물질 혼화재료를 사용한 수중불분리성 콘크리트의 배합 및 품질평가 방안 검토)

  • Park, Yong Kyu;Kim, Hyun Woo;Yoon, Ki Woon
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.6
    • /
    • pp.679-686
    • /
    • 2014
  • In this research, the mix proportion of the antiwashout underwater concrete with the mineral admixture was evaluated. It can reduce the amount used of the antiwashout admixture (hereinafter referred to as "AWA") and satisfy the properties of concrete. In addition, the review for the difference of the test and practical affairs were conducted. Optimized unit quantity of water of antiwashout underwater concrete and the amount used of AWA was revealed by $190kg/m^3$, 0.9%/W, respectively. In particularly, the mix design is reduced by 5% than the W/B of target strength even though the W and AWA reduced. Therefore, it will have the economical feasibility and qualities including the material separation, resistance characteristic and compressive strength, and etc. The stable value was shown in 1 point of minute passed in the measurement of the turbidity amounts using the turbidimeter after the checker insertion. However, it needs to be reviewed for the interrelationship between turbidity measuring machine and KCI-AD102 standard method. There were no significant differences of compressive strength of specimens in the water depending on the production methods.

A Comparative Study on Direct Instrument Methods in Open Channel for Measuring River Water Usage (하천수 사용량 계측을 위한 개수로에서의 직접 계측방법 비교 연구)

  • Baek, Jongseok;Kim, Chiyoung;Lee, Kisung;Kang, Hyunwoong;Song, Jaehyun
    • Journal of Korean Society of Disaster and Security
    • /
    • v.13 no.4
    • /
    • pp.65-74
    • /
    • 2020
  • Continuous and accurate instrument of river water usage is needed for sustainable river water management. Although the instrument methods applicable to each point of use of river water are different, more precise direct instrument methods are required at the point of major open channel. Users of river water should select appropriate direct instrument methods to measure usage, but there is a lack of standards and verification research. In this study, the H-Q rating curve method, ultrasonic method, and microwave method were applied directly to the test basin in the upper basin of Mangyeong river, and the accuracy of measurement data was evaluated by comparing absolute error between discharge data calculated by instrument method. When comparing the calculated discharge of point units, the ultrasonic method showed the best results of the actual measurement. Through continuous instrument, the sum of the daily and monthly units was compared, and the ultrasonic and microwave methods were shown to be highly accurate. Based on the results of this study, it is hoped that the appropriate direct measurement method can be selected according to the importance of the river water use facility, considering that the ultrasonic method and the microwave method are relatively costly compared to the water level-flow relationship method.

Evaluation of Structural Performance of Reinforced Concrete Beams Retrofitted by Embedded FRP Rod and Metal Fittings (매입형 FRP봉과 보강철물을 보강한 철근콘크리트 보의 구조성능 평가)

  • Ha, Gee-Joo;Shin, Jong-Hack;Ha, Young-Joo;Kang, Hyun-Wook
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.4
    • /
    • pp.445-452
    • /
    • 2012
  • In this study, experimental research was carried out to evaluate the structural performance of the reinforced concrete beam using strengthening materials (embedded FRP rod, metal fittings) in existing reinforced concrete buildings. Seven reinforced concrete beams comprised of retrofitted embedded FRP rod (BCR series), embedded FRP rod with metal fittings (BCR-AC series), and standard specimen (BSS) were constructed and tested under monotonic loading. Design parameters of test specimens were amount of embedded FRP rod and metal fittings. The test results showed that the maximum load carrying capacity of specimens with embedded FRP rod (BCR series) and embedded FRP rod with metal fittings (BCR-AC series) increased by 21~55% and 21~63%, respectively, in comparison with the standard specimen BSS. BCR series test specimens failed by the adhesion slip and concrete cover separation. BCR-AC series test specimens failed by the adhesion slip due to the confining effect of metal fittings.

Ternary Bloom Filter Improving Counting Bloom Filter (카운팅 블룸필터를 개선하는 터너리 블룸필터)

  • Byun, Hayoung;Lee, Jungwon;Lim, Hyesook
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.1
    • /
    • pp.3-10
    • /
    • 2017
  • Counting Bloom filters (CBFs) have been popularly used in many network algorithms and applications for the membership queries of dynamic sets, since CBFs can provide delete operations, which are not provided in a standard 1-bit vector Bloom filter. However, because of the counting functions, a CBF can have overflows and accordingly false negatives. CBFs composed of 4-bit counters are generally used, but the 4-bit CBF wastes memory spaces by allocating 4 bits for every counter. In this paper, we propose a simple alternative of a 4-bit CBF named ternary Bloom filter (TBF). In the proposed TBF structure, if two or more elements are mapped to a counter in programming, the counters are not used for insertion or deletion operations any more. When the TBF consumes the same amount of memory space as a 4-bit CBF, it is shown through simulation that the TBF provides a better false positive rate than the CBF as well as the TBF does not generate false negatives.

Improvement of Field Uniformity in a Reverberation Chamber with Various Numbers of a 2D CRD (2D CRD 수에 따른 전자파 잔향실 내의 필드 균일성 개선)

  • Kim, Jin-Bok;Rhee, Joong-Geun;Kim, Jung-Hoon;Rhee, Eu-Gene
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.4
    • /
    • pp.18-24
    • /
    • 2010
  • This paper presents the improvement of the field uniformity in a reverberation chamber which can be substitute an anechoic chamber for the electromagnetic interference (EMI) and immunity test. Nowadays, there are many EMI issues due to the increasing use of wireless local area network (LAN), digital multimedia broadcasting (DMB), and mobile internet. With this reason, this paper studied the field characteristics in a reverberation chamber for 2.3 GHz band. In this paper, the finite difference time domain (FDTD) method is used to analyze the field characteristics in a reverberation chamber. To improve the field uniformity in the reverberation chamber, this paper adopted a 2D cubical residue diffuser (CRD) with varying the disposition and number of CRD. For each case, the tolerance and standard deviation of the electric field strength are evaluated. In comparison with the reverberation chamber without any CRD, the reverberation chamber with two CRDs showed improved results; 1.98 dB improvement in standard deviation and 3.6 dB improvement in tolerance.

Development of Fragmentation Management Simulator for 6LoWPAN (6LoWPAN 단편화 관리 기법 시뮬레이터 개발)

  • Seo, Hyun-Gon;Han, Jae-Il
    • Journal of the Korea Society for Simulation
    • /
    • v.17 no.4
    • /
    • pp.191-198
    • /
    • 2008
  • 6LoWPAN (IPv6 Low-power Wireless Personal Area Network) is IPv6 packets transmission technology at Sensor network over the IEEE 802.15.4 Standard MAC and Physical layer. Adaptation layer between IP layer and MAC layer performs fragmentation and reassembly of packet for transmit IPv6 packets. RFC4944, IETF 6LoWPAN WG standard document define packet fragmentation and reassembly. In this paper, we propose the 6PASim (6LoWPAN Packet Simulator) to perform IPv6 packet fragmentation and reassembly for performance evaluation. The 6PASim consist of two parts. One is Packet_Transmit_module that makes IEEE 802.15.4 frames the IPv6 packet from upper layer, and transmit its. and the another is Packet_Receive_module that reassembles transferred frames and completes original IPv6 packets. we can evaluate frame transmit rate and amount of control message through 6PASim. The result of simulation shows the SRM (Selective Retransmission Method) scheme provider better performance than IRM (Immediate Retransmission Method) scheme.

  • PDF

A convergence study about Influences of hematopoietic stem cell transplantation on children growth (소아암 환아의 조혈모세포이식 후 성장에 관한 융합 연구)

  • Lim, Su-Jin
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.4
    • /
    • pp.49-57
    • /
    • 2017
  • This is a convergence study about influences of hematopoietic stem cell transplantation on children growth. For this explanatory survey research, data were collected with medical record of 112 children with malignant and hematological diseases received HSCT from February to March, 2009. To analyze the growth after HSCT, mixed-effects model was used. The mean SDS of height and weight were negative values in HSCT. The mean value of SDS were significantly lower in autologous HSCT group by height(p=0.0008) and weight(p= 0.0012). Significant factors on changes of SDS of height growth were age at HSCT(p=0.0251), autologous HSCT(p=0.0020) and total dose of steroid in allogeneic HSCT (p=0.0403) and age at HSCT(p=0.0042), autologous HSCT(p=0.0035), and duration of TPN(p=0.0159) for weight growth. According to the results, we must learn to recognize the predicting growth impairment after HSCT in children. regarding nursing interventions should be conducted in the care of these children.

Development of Standard Checklist for Safety Management of Toxic Gas facility in Domestic University Laboratory (국내 대학 실험실 독성가스 시설의 안전관리를 위한 표준 체크리스트 개발)

  • Lee, Sungjin;Kim, Byung-Duk;Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.92-98
    • /
    • 2015
  • Toxic gases are managed by High Pressure Gas Safety Control Act. Toxic Gases are "31 designated species and each gas of which the permissible concentration($LC_{50}$) is equal to or less than 5000 ppm as defined in High Pressure Gas Safety Control Act.". Korean toxic gas usage in accordance with the growth of the electronic industry has increased explosively. The demand of toxic gas research in domestic university laboratories has grown together. But the research associated with toxic gas safety management in the domestic laboratory is nonexistent state. In this study, we identified weak points of toxic gas safety management through a survey of domestic university laboratory facilities. This paper presented toxic gas safety measures in order to overcome those weak points. Also this paper developed a standard checklist to improve and ensure safe management of toxic gas facility in accordance with the proposed measures. This research is to enforce safety management of toxic gas facilities in domestic university laboratory and it will provide safety guidelines for every laboratory.