• Title/Summary/Keyword: 표적 장치

Search Result 198, Processing Time 0.022 seconds

Directivity Characteristics Control of Ultrasonic Transducer Array Using Two-layered Piezoelectric Transducer (2층 구조 압전 트랜스듀서를 이용한 초음파 트랜스듀서 어레이의 지향 특성 가변)

  • 김정호;송인진;하강렬;김천덕;김무준
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.8
    • /
    • pp.629-636
    • /
    • 2003
  • It will be very convenient if the directivity characteristics of ultrasonic transducer array are controllable by the purpose of use in the fields of sonar system or ultrasonic diagnostic system, In this paper, a control method of the directivity characteristics was suggested. The transducer array was consisted of two-layered piezoelectric vibrators. Efficiency of each vibrator is controlled in 2nd harmonic mode by electrical capacitance. Therefore, the beam width of the transducer array can be controlled by changing the capacitance. The directivity characteristics of the array were analyzed experimentally and theoretically. As the results, it is confirmed that -3 dB beam width of main lobe can be controlled in the range of 7.6°∼16.2°.

Development of Virtual Target Signal Generator for Verifying the Shipborne Tracking Radar Performance (함정용 추적레이더 성능 검증을 위한 모의표적신호발생장치 개발)

  • Yi, Hui-Min;Son, Jae-Hyun;Na, Young-Jin;Kim, Dong-Hawn
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.66-74
    • /
    • 2012
  • The virtual target signal generator was developed to verify the shipborne tracking radar performance. It was used to DRFM(Digital RF Memory) method to generate the virtual moving targets. The target signal includes Doppler shift and RCS according to the target motion. And the signal generator can make jamming signal and clutter to test shipborne radar performance at real environmental condition. This paper described the functional diagram and the hardware configuration items to meet the test requirements for the tracking radar. And it showed the critical design points for the sub-systems. The signal generator which was developed in this paper shared the operational information of the radar with the radar command and control part. To test the frequency agility of the radar, it had the local oscillator which could do high speed frequency switching according to radar information. By communicating between the signal generator and the radar command and control part, the local oscillator of signal generator could be controlled every pulse. It reduced the instantaneous bandwidth of signal generator and minimized the spurious. So it lowered the probability of generating wrong targets.

THE ANALYTIC ANALYSIS OF SUPPRESSING JET FLOW AT GUIDE TUBE OF CIRCULAR IRRADIATION HOLE IN HANARO (하나로 원형 조사공의 안내관 제트유동 억제에 대한 해석)

  • Park Y.C.;Wu S.I.
    • Journal of computational fluids engineering
    • /
    • v.10 no.2
    • /
    • pp.1-6
    • /
    • 2005
  • The HANARO, a multi-purpose research reactor of 30 MWth, open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. The HANARO is composed af inlet plenum, grid plate, core channel with flow tubes and chimney. The reactor core channel is located at about twelve meters (12 m) depth of the reactor pool and cooled by the upward flow that the coolant enters the lower inlet of the plenum, rises up through the grid plate and the core channel and comes out from the outlet of chimney. A fission moly guide tube is extended from the reactor core to the top of the reactor chimney for easily loading a fission moly target under the reactor normal operation. But active coolant through the core can be quickly raised up to the top of the chimney through the guide tube by jet flow. This paper describes an analytical analysis that is the study of the flow behavior through the guide tube under reactor normal operation and unloading the target. As results, it was conformed through the analysis results that the flow rate, reduced to about fourteen kilogram per second (14 kg/s) from the original flow rate of sixteen point three kilogram per second (16.3 kg/s) did not show the guide tube jet.

Enhancement of Mixing Performance in Viscous Liquid Using an Electromagnetically Driven Microrobot (초소형 로봇을 이용한 점도성 유체의 혼합 효율 향상)

  • Song, Hyeonseok;Park, Yuna;Chung, Sang Kug
    • Journal of the Korean Society of Visualization
    • /
    • v.16 no.2
    • /
    • pp.53-58
    • /
    • 2018
  • This paper presents an electromagnetically driven microrobot for the enhancement of mixing performance in high viscous liquid media such as blood and bone marrow. First, an electromagnetic system was fabricated, and the magnetic flux density generated from the system was compared with the theoretical value. Second, the reciprocating motion of the microrobot was demonstrated in microchannel using electromagnetic system. As a proof of concept, the mixing performance by the electromagnetically driven microrobot in high viscous liquid was investigated using safranin solution. As a result, it was completely mixed within 140 s with the reciprocating motion of the microrobot while it took 1680 s for natural diffusion. In addition, the mixing efficiency was quantitatively evaluated through a mixing index obtained by an image analysis. The proposed method provides not only wireless actuation of a microrobot with a simple design but also high mixing performance in variety of high viscous liquid media.

Flow Characteristics for Guide Tube of Circular Irradiation Hole in HANARO (하나로 원형 조사공의 안내관 유동특성)

  • Park, Y.C.;Wu, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1835-1840
    • /
    • 2004
  • The HANARO, a multi-purpose research reactor of 30 MWth, open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. The HANARO is composed of inlet plenum, grid plate, core channel with flow tubes and chimney. The reactor core channel is located at about twelve meters (12 m) depth of the reactor pool and cooled by the upward flow that the coolant enters the lower inlet of the plenum,. rises up through the grid plate and the core channel and comes out from the outlet of chimney. A guide tube is extended from the reactor core to the top of the reactor chimney for easily un/loading a target under the reactor normal operation. But active coolant through the core can be quickly raised up to the top of the chimney through the guide tube by a jet flow. This paper describes an analytical analysis that is the study of the flow behavior through the guide tube under reactor normal operation and unloading the target. As results, it was conformed through the analysis results that the guide jet is suppressed under the top of the chimney after modifying the orifice diameter of 37.5 mm to 31 mm.

  • PDF

Application of LFM Reverberation Suppression Using Difference of Singular Values in the Underwater Obstacle Detection (수중 장애물 탐지에서의 특이 값 차이를 이용한 LFM 잔향 감소 기법 적용 연구)

  • Lee, Hyung-Soo;Kwon, Bum-Soo;Cho, Chom-Gun;Lee, Kyun-Kyung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.8
    • /
    • pp.755-760
    • /
    • 2009
  • In this paper, we apply a reverberation suppression method using difference of singular values to improve the short-distance underwater obstacle detection probability in reverberation environment induced by a linear frequency modulation signal. The reverberation suppression method using difference of singular values suppresses LFM reverberation based on subtracting the singular values for a reference beam, assumed to contain only the reverberation, from those for the current beam of interest, assumed to contain the reverberation and target echo. For the validation, the reverberation suppression method using difference of singular values is applied to real oceanic data, which are acquired using the cross type array.

A Study on the Design and Rectification Method of a KW class Power Converter Unit for an Aircraft Mounted Guided Missile (항공기 장착 유도탄의 KW급 전력변환장치 설계와 정류방식에 따른 연구)

  • Kim, Hyung-Jae;Jung, Jae-Won;Lee, Dong-Hyeon;Kim, Gil-Hoon;Moon, Mi-Youn
    • Journal of Advanced Navigation Technology
    • /
    • v.26 no.2
    • /
    • pp.99-104
    • /
    • 2022
  • Recently, the domestic demand for weapon systems based on aircraft platforms is gradually increasing. In particular, the demand for effective precision guided missile(PGM) which cruises for several hundred kilometers after launch to strike the ground target is rising drastically, but it is in the early stages of development, and research based on it are limited. This paper is a study on the power converter unit(PCU) within PGM which is mounted on an aircraft platform based on MIL-STD-1760, which is an interface between an aircraft and PGM. We investigated the electrical properties and structure of the umbilical connector, and the aircraft/store electrical interconnection system. Also, the focus on the design specifications of the PCU that supplies power were described. This result 3 phase AC input, which is the state for the guided simulation power supply in the state of being mounted on an aircraft that rectification method with power factor correction(PFC) compared to bridge rectifier circuit. In the future, it may be used as a basis for power supply design on aircraft mounted weapon systems.

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF

Prediction of Target Motion Using Neural Network for 4-dimensional Radiation Therapy (신경회로망을 이용한 4차원 방사선치료에서의 조사 표적 움직임 예측)

  • Lee, Sang-Kyung;Kim, Yong-Nam;Park, Kyung-Ran;Jeong, Kyeong-Keun;Lee, Chang-Geol;Lee, Ik-Jae;Seong, Jin-Sil;Choi, Won-Hoon;Chung, Yoon-Sun;Park, Sung-Ho
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.132-138
    • /
    • 2009
  • Studies on target motion in 4-dimensional radiotherapy are being world-widely conducted to enhance treatment record and protection of normal organs. Prediction of tumor motion might be very useful and/or essential for especially free-breathing system during radiation delivery such as respiratory gating system and tumor tracking system. Neural network is powerful to express a time series with nonlinearity because its prediction algorithm is not governed by statistic formula but finds a rule of data expression. This study intended to assess applicability of neural network method to predict tumor motion in 4-dimensional radiotherapy. Scaled Conjugate Gradient algorithm was employed as a learning algorithm. Considering reparation data for 10 patients, prediction by the neural network algorithms was compared with the measurement by the real-time position management (RPM) system. The results showed that the neural network algorithm has the excellent accuracy of maximum absolute error smaller than 3 mm, except for the cases in which the maximum amplitude of respiration is over the range of respiration used in the learning process of neural network. It indicates the insufficient learning of the neural network for extrapolation. The problem could be solved by acquiring a full range of respiration before learning procedure. Further works are programmed to verify a feasibility of practical application for 4-dimensional treatment system, including prediction performance according to various system latency and irregular patterns of respiration.

  • PDF

Fabrication and Evaluation of a VHF Focusing Ultrasonic Transducer Made of PVDF Piezoelectric Film (PVDF 압전막을 이용한 초고주파 집속 초음파 트랜스듀서의 제작 및 특성 평가)

  • Yoon, Ju-Ho;Oh, Jung-Hwan;Kim, Jung-Soon;Kim, Moo-Joon;Ha, Kang-Lyeol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.4
    • /
    • pp.215-222
    • /
    • 2011
  • In order to obtain high resolution images, a focusing ultrasonic transducer operated in very high frequency (VHF) range was fabricated and its characteristics were evaluated. A 9-${\mu}m$ thick PVDF film with only one metalized surface for electric ground was adhered to a CCP (Copper-clad polyimide) film by using epoxy. It was pressed by a metal ball to form a concave surface and its rear side was filled with the epoxy. The radius of curvature and the f-number of the fabricated transducer are 7.5 mm and 1.7, respectively. The pulse-echo measurement results from a target located at the focal point showed that the frequency bandwidth was 35.0 MHz and the insertion loss near the peak frequency of approximately 40 MHz was about 60 dB. Those values agreed well with the simulation results by the KLM equivalent circuit analysis including the effect of the epoxy bonding layer. When the image of thin copper lines by the 35 MHz transducer of the UBM (Ultrasonic Backscattering Microscope) system was compared with the image by the transducer fabricated in this study, the fabricated transducer was observed that the axial resolution was improved although the lateral resolution was degraded.