Fabrication and Evaluation of a VHF Focusing Ultrasonic Transducer Made of PVDF Piezoelectric Film  

Yoon, Ju-Ho (부경대학교 기계공학과)
Oh, Jung-Hwan (부경대학교 의공학과)
Kim, Jung-Soon (동명대학교 멀티미디어공학과)
Kim, Moo-Joon (부경대학교 물리학과)
Ha, Kang-Lyeol (부경대학교 물리학과)
Abstract
In order to obtain high resolution images, a focusing ultrasonic transducer operated in very high frequency (VHF) range was fabricated and its characteristics were evaluated. A 9-${\mu}m$ thick PVDF film with only one metalized surface for electric ground was adhered to a CCP (Copper-clad polyimide) film by using epoxy. It was pressed by a metal ball to form a concave surface and its rear side was filled with the epoxy. The radius of curvature and the f-number of the fabricated transducer are 7.5 mm and 1.7, respectively. The pulse-echo measurement results from a target located at the focal point showed that the frequency bandwidth was 35.0 MHz and the insertion loss near the peak frequency of approximately 40 MHz was about 60 dB. Those values agreed well with the simulation results by the KLM equivalent circuit analysis including the effect of the epoxy bonding layer. When the image of thin copper lines by the 35 MHz transducer of the UBM (Ultrasonic Backscattering Microscope) system was compared with the image by the transducer fabricated in this study, the fabricated transducer was observed that the axial resolution was improved although the lateral resolution was degraded.
Keywords
Very high frequency (VHF); Ultrasonic transducer; PVDF piezoelectric film; Insertion loss; Spatial resolution;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 R. Krimholtz, D.A. Leedom, and G.L. Matthaei, "New equivalent circuit for elementary piezoelectric transducers", Electron. Lett., vol. 6, pp. 398-399, 1970.   DOI   ScienceOn
2 S. Sherrit, S.P. Leary, B.P. Dolgin, and Y. Bar-Cohen "Comparison of the Mason and KLM equivalent circuits for piezoelectric resonators in the thickness mode", 1999 IEEE Ultrasonics Symposium, pp. 921-926, 1999.
3 양정화, 이경성, 강관석, 팽동국, 최민주, "초음파프로브의 결함이 B-모드 영상의 공간 분해능에 미치는 영향," 한국음향학회 2009년도 춘계학술발표대회 논문집, 제28권, 1(s)호, 176-179쪽, 2009.
4 최광윤, 하강렬, 김무준, 김정순, 양정화, 강관석, 최민주, "의료용 초음파프로브의 압전소자 결함이 과도음장과 B-모드 영상에 미치는 영향," 한국음향학회지, 제29권, 8호, 476-482쪽, 2010.
5 G. S. Kino, Acoustic waves -devices, imaging, & analog signal processing-, Prentice-Hall Inc., Englewood Cliffs, 1987.
6 T. A. Ritter, T. R. Shrout, R. Tutwiler, and K. K. Shung, "A 30-MHz piezo-composite ultrasound array for medical imaging applications", IEEE Trans. on UFFC, vol. 49, no. 2, pp. 217-230, 2002.   DOI   ScienceOn
7 M. Robert. G. Molingou, K. Snook, J. Cannata, and K. K. Shung, "Fabrication of focused poly (vinylidene fluoridetrifluoroethylene) P (VDF-TrFE) copolymer 40-50 MHz ultrasound transducers on curved surfaces", Journal of Applied Physics, vol. 96, no. 1, pp. 252-256, 2004.   DOI   ScienceOn
8 J. A. Ketterling, F. L. Lizzi, O. Aristizabal, and D. H. Turbull. "Design and fabrication of a 40-MHz annular array transducer", IEEE Trans. on UFFC, vol. 52, no. 4, pp. 672- 681, 2005.   DOI   ScienceOn
9 A. Denoyer, F. Ossant, B. Arbeille, F. Fetissof, F. Patat, L. Pourcelot, and P. J. Pisella, "Very-high-frequency ultrasound corneal imaging as a new tool for early diagnosis of ocular surface toxicity in rabbits treated with a preserved glaucoma drug", Ophthalmic Res., vol. 40, pp. 298-308, 2008.   DOI   ScienceOn
10 F. S. Foster, C. J. Pavlin, G. R. Lockwood, L. K. Ryan, K. A. Harasiewicz, L. R. Berube, and A. M. Rauth, "Principles and applications of ultrasound backscatter microscopy", IEEE Trans. on UFFC, vol. 40, no. 5, pp. 608-617, 1993.   DOI   ScienceOn
11 F. S. Foster, C. J. Pavlin, K. A. Harasiewicz, D. A. Christopher, and D. H. Turnbull, "Advanced in ultrasound biomicroscopy", Ultrasound in Med. & Bilo., vol. 26, no. 1, pp. 1-27, 2000.   DOI   ScienceOn
12 http://www.capolabs.com/index.htm
13 C. Passmann and H. Ermert, "A 100-MHz ultrasound imaging system for dermatologic and ophthalmologic diagnostics", IEEE Trans. on UFFC, vol. 43, no. 4, pp. 545-552, 1996.   DOI   ScienceOn