• Title/Summary/Keyword: 표적 위치

Search Result 440, Processing Time 0.035 seconds

A Study on Signal Processing of Ballistic Missile Warhead Discrimination Using ESPRIT in Millimeter-Wave(Ka-Band) Seeker (밀리미터파 탐색기에서 ESPRIT 기법을 이용한 탄도 미사일 탄두 식별 신호처리 기법 개발)

  • Choi, Gak-Gyu;Han, Seung-Ku;Jo, Hee-Jin;Kim, Hyo-Tae;Kim, Kyung-Tae;Song, Sung-Chan;Na, Young-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.2
    • /
    • pp.266-269
    • /
    • 2012
  • This paper introduces a signal processing technique for discrimination of ballistic missile's warhead. An interceptor missile to destroy the enemy's ballistic missile requires an information on the location of missile's warhead. In order to detect and locate the missile's warhead, a seeker radar in the interceptor missile makes use of chirp waveform to generate high resolution range profiles(HRRPs). We applied one of the well known spectral estimation technique called ESPRIT (Estimation of Signal Parameters by Rotational Invariance Technique) to these HRRPs to estimate scattering centers on the target. Using the information on the one-dimensional(1-D) scattering centers, we can find the location of the warhead by estimating the length of the missile, Simulation results show that the proposed signal processing technique is efficient in discriminating the warhead of an ballistic missile.

A Study on the Deployment of a Sea Based Sensor Platform for the Detection of a SLBM (잠수함 발사 탄도미사일 탐지를 위한 해상 센서플랫폼의 배치에 관한 연구)

  • Kim, Jiwon;Kwon, Yong Soo;Kim, Namgi;Kim, Dong Min;Park, Young Han
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.5
    • /
    • pp.363-369
    • /
    • 2015
  • This paper describes deployment of a sea based sensor platform for the detection of a submarine launched ballistic missile (SLBM). Recently, North Korea successfully conducted the underwater launching test of the SLBM, which will seriously threaten the global security. To defend these threats successfully, a sensor platform of the ballistic missile defense (BMD) should be deployed in the area of high detection probability of the missile. The maximum detection range characteristics of the typical radar sensor system, however, depend on the radar cross section (RCS) and flight trajectories of the target. In this point of view, this work analyzed the flight trajectories based on the tactics and calculated the RCS of the SLBM. In addition, sea based sensor platform position is proposed from the analysis of the detection time.

Effect of Task-irrelevant Feature Information on Visual Short-term Recognition of Task-relevant Feature (기억자극의 과제 무관련 세부특징 정보가 과제 관련 세부특징에 대한 시각단기재인에 미치는 영향)

  • Hyun, Joo-Seok
    • Korean Journal of Cognitive Science
    • /
    • v.23 no.2
    • /
    • pp.225-248
    • /
    • 2012
  • The summed-similarity model of visual short-term recognition proposes that the estimated amount of summed similarity between remembered items and a recognition probe determines recognition judgement decision (Kahan & Sekuler, 2002). This study examined the effect of a task-irrelevant location change on the recognition decision against two remembered Gabor gratings differing in their spatial frequencies. On each trial in Experiment, participants reported if two gratings displayed across the visual fields are the same or not as the probe grating displayed after about a second of memory delay. The probe grating would be the same as or different from the memory items (lure) by 1 or 4 JND units. The location of the probe would also vary randomly across the left and right visual field with respect to the location of the corresponding memory item. The participants were instructed to perform their recognition task exclusively to the spatial frequencies of the memory items and the probe while ignoring the potential location change of the probe. The results showed that false-recognition rates of the lure probe increased as the summed similarity between the memory items and the probe increased. The rates also further increased in the condition where the probe location was different from the location of the corresponding memory item compared to the condition where the probe location was the same. The increased false-recognition rates indicate that information stored into visual short-term memory is represented as a form of well-bound visual features rather than independent features.

  • PDF

Inter-fractional Target Displacement in the Prostate Image-Guided Radiotherapy using Cone Beam Computed Tomography (전립선암 영상유도 방사선 치료시 골반내장기의 체적변화에 따른 표적장기의 변화)

  • Dong, Kap Sang;Back, Chang Wook;Jeong, Yun Jeong;Bae, Jae Beom;Choi, Young Eun;Sung, Ki Hoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.161-169
    • /
    • 2016
  • Purpose : To quantify the inter-fractional variation in prostate displacement and their dosimetric effects for prostate cancer treatment. Materials and Methods : A total of 176 daily cone-beam CT (CBCT) sets acquired for 6 prostate cancer patients treated with volumetric-modulated arc therapy (VMAT) were retrospectively reviewed. For each patient, the planning CT (pCT) was registered to each daily CBCT by aligning the bony anatomy. The prostate, rectum, and bladder were delineated on daily CBCT, and the contours of these organs in the pCT were copied to the daily CBCT. The concordance of prostate displacement, deformation, and size variation between pCT and daily CBCT was evaluated using the Dice similarity coefficient (DSC). Results : The mean volume of prostate was 37.2 cm3 in the initial pCT, and the variation was around ${\pm}5%$ during the entire course of treatment for all patients. The mean DSC was 89.9%, ranging from 70% to 100% for prostate displacement. Although the volume change of bladder and rectum per treatment fraction did not show any correlation with the value of DSC (r=-0.084, p=0.268 and r=-0.162, p=0.032, respectively), a decrease in the DSC value was observed with increasing volume change of the bladder and rectum (r=-0.230,p=0.049 and r=-0.240,p=0.020, respectively). Conclusion : Consistency of the volume of the bladder and rectum cannot guarantee the accuracy of the treatment. Our results suggest that patient setup with the registration between the pCT and daily CBCT should be considered aligning soft tissue.

  • PDF

Convolution-Superposition Based IMRT Plan Study for the PTV Containing the Air Region: A Prostate Cancer Case (Convolution-Superposition 알고리즘을 이용한 치료계획시스템에서 공기가 포함된 표적체적에 대한 IMRT 플랜: 전립선 케이스)

  • Kang, Sei-Kwon;Yoon, Jai-Woong;Park, Soah;Hwang, Taejin;Cheong, Kwang-Ho;Han, Taejin;Kim, Haeyoung;Lee, Me-Yeon;Kim, Kyoung Ju;Bae, Hoonsik
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.271-277
    • /
    • 2013
  • In prostate IMRT planning, the planning target volume (PTV), extended from a clinical target volume (CTV), often contains an overlap air volume from the rectum, which poses a problem inoptimization and prescription. This study was aimed to establish a planning method for such a case. There can be three options in which volume should be considered the target during optimization process; PTV including the air volume of air density ('airOpt'), PTV including the air volume of density value one, mimicking the tissue material ('density1Opt'), and PTV excluding the air volume ('noAirOpt'). Using 10 MV photon beams, seven field IMRT plans for each target were created with the same parameter condition. For these three cases, DVHs for the PTV, bladder and the rectum were compared. Also, the dose coverage for the CTV and the shifted CTV were evaluated in which the shifted CTV was a copied and translated virtual CTV toward the rectum inside the PTV, thus occupying the initial position of the overlap air volume, simulating the worst condition for the dose coverage in the target. Among the three options, only density1Opt plan gave clinically acceptable result in terms of target coverage and maximum dose. The airOpt plan gave exceedingly higher dose and excessive dose coverage for the target volume whereas noAirOpt plan gave underdose for the shifted CTV. Therefore, for prostate IMRT plan, having an air region in the PTV, density modification of the included air to the value of one, is suggested, prior to optimization and prescription for the PTV. This idea can be equally applied to any cases including the head and neck cancer with the PTV having the overlapped air region. Further study is being under process.

Setup Verification in Stereotactic Radiotherapy Using Digitally Reconstructed Radiograph (DRR) (디지털화재구성사진(Digitally Reconstructed Radiograph)을 이용한 정위방사선수술 및 치료의 치료위치 확인)

  • Cho, Byung-Chul;Oh, Do-Hoon;Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.84-88
    • /
    • 1999
  • Purpose :To develop a method for verifying a treatment setup in stereotactic radiotherapy by ma- tching portal images to DRRs. Materials and Methods : Four pairs of orthogonal portal images of one patient immobilized by a thermoplastic mask frame for fractionated stereotactic radiotherapy were compared with DRRs. Portal images are obtained in AP (anteriorfposterior) and lateral directions with a target localizer box containing fiducial markers attached to a stereotactic frame. DRRs superimposed over a planned iso-center and fiducial markers are printed out on transparent films. And then, they were overlaid over onhogonal penal images by matching anatomical structures. From three different kind of objects (isgcenter, fiducial markers, anatomical structure) on DRRs and portal images, the displacement error between anatomical structure and isocenters (overall setup error), the displacement error between anatomical structure and fiducial markers (irnrnobiliBation error), and the displacement error between fiducial markers and isocenters (localization error) were measured. Results : Localization error were 1.5$\pm$0.3 mm (AP), 0.9$\pm$0.3 mm (lateral), and immobilization errors were 1.9$\pm$0.5 mm (AP), 1.9$\pm$0.4 mm (lateral). In addition, overall setup errors were 1.0$\pm$0.9 mm (AP), 1.3$\pm$0.4 mm (lateral). From these orthogonal displacement errors, maximum 3D displacement errors($\sqrt{(\DeltaAP)^{2}+(\DeltaLat)^{2}$)) were found to be 1.7$\pm$0.4 mm for localization, 2.0$\pm$0.6 mm for immobilization, and 2.3$\pm$0.7 mm for overall treatment setup. Conclusion : By comparing orthogonal portal images with DRRs, we find out that it is possible to verify treatment setup directly in stereotactic radiotherapy.

  • PDF

A Study on the Quality Improvement of Red Dot Sight for Grenade Launcher by Parallax Reduction (고속유탄기관총용 조준경의 시차 개선을 통한 조준경 품질 향상에 관한 연구)

  • Kim, Ji-Hoon;Jeung, Bo-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.130-135
    • /
    • 2019
  • This study performed the quality improvement of a red dot sight for a 40 mm grenade launcher through parallax reduction. The red dot sight cited in this study is currently in mass production for military use as a non-weapon system. While the red dot sight's parallax currently meets requirements, slightly greater error was observed on the outside of effective optical area of the reflection lens compared to other sights. Parallax is easily affected by eye movement, which can result in aiming error. To improve the red dot sight's quality, this study analyzed why parallax is observed in the effective optical area of the reflection lens and how to reduce it. As a result, the red dot sight demonstrated lower parallax error using the new optical system design with an increased reflection lens thickness and modified components configuration related to the reflection lens assembly. Parallax was calculated and simulated by using a particular program to verify that it decreased. This improvement for the 40 mm. grenade launcher red dot sight more than satisfies requirements, offers advanced capabilities for users, and as a result, successful operation carryout.

Evaluation of Dose and Position Compensation of Parotid Gland Using CT On-rail System in Head-and-Neck Cancer (두경부 암환자 치료 시 CT On-rail System을 이용한 이하선의 위치 보정 및 선량 평가)

  • Jang, Hyeong-Jun;Im, Chung-Geun;Chun, Geum-Sung;Jeong, Il-Seon;Kim, Hoi-Nam
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.83-89
    • /
    • 2008
  • Purpose: The checking method of target and normal structure are used by MVCBCT, KVCBCT, CT On-rail System, Ultrasound in H&N cancer patient. In case of MVCT, the utilization of bone structure is valuable to check around tissue. But the utilization of soft tissue is not enough. The point of this paper is dose variation in movable parotid and changeable volume of H&N cancer patient of CT On-rail System. Materials and Methods: The object of H&N cancer patient is 5 in this hospital. The selected patient are scanned ARTISTE CT Vision (CT On-ral System) a triweekly. After CT scanning, tranfered coordinates are obtained by movable of parotid gland comparison with planning image. Checking for the changeable volume of parotid gland. A Obtained CT image are tranfered to the RTP System. So dose variation are checked by following changed volume. Results: The changes of target coordinate by the parotid gland movement are X: -0.4~0.4 cm, Y: -0.4~0.3 cm, Z: -0.3~0.3 cm. the volume of GTV is decreased to about 7.11%/week and then both parotid gland volume are shrinked about 4.81%/week (Lt), 2.91%/week (Rt). At the same time, each parotid gland are diminished in radiation dose as 3.66%/week (Lt), 2.01%/week. Conclusion: Images from CT on the rail System which are able to aquire the better quality images of soft tissue in Target area than MVCBCT. After replanning and dose redistribution by required images, It could gain not only the correction of the patient set-tup errors but exact dose distribution. Accordingly, the delivery of compensated dose, It makes that we could do Adaptive Targeting Radiotherapy and need Real Time Adaptive Targeting Radiotherapy by reduce beam delivary time.

  • PDF

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.

A Construction of Integrated Binding Service of The Selected Objects Considering Loads in Wide-Area Object Computing Environments (광역 객체 컴퓨팅 환경에서 부하를 고려한 선정된 객체의 통합 바인딩 서비스의 구축)

  • Kang, Myung-Suk;Jeong, Chang-Won;Joo, Su-Chong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2002.11b
    • /
    • pp.1487-1490
    • /
    • 2002
  • 최근 분산 컴퓨팅 환경은 급진적으로 광역화되고, 이질적이며, 연합형태의 광역 시스템 구조로 변화하고 있다. 이러한 환경은 네트워크상에 광범위한 서비스를 제공하는 통신 네트워크 기반에서 구현된 수많은 객체로 구성된다. 더욱, 지구상에 존재하는 모든 객체들은 이름이나 속성에 의해 중복된 특성을 갖는다. 이러한 같은 특성을 갖는 객체들은 중복 객체로 정의된다. 그러나 기존의 네이밍이나 트레이딩 메커니즘은 독립적인 위치 투명성이 결여로 중복된 객체들의 바인딩 서비스 지원이 불가능하다. 서로 다른 시스템 상에 존재하는 중복된 객체들이 동일한 서비스를 제공한다면, 각 시스템의 부하를 고려하여 클라이언트의 요청을 분산시킬 수 있다. 이러한 이유로 본 논문에서는 광역 컴퓨팅 환경에서 중복된 객체들의 위치 관리뿐만 아니라 시스템들간의 부하 균형화를 유지하기 위해서 최소부하를 갖는 시스템에 위치한 객체의 선정하여 동적 바인딩 서비스를 제공할 수 있는 새로운 모델을 설계하고 구현하였다. 이 모델은 네이밍 및 트래이딩 기능을 통합한 서비스에 의해 중복된 객체들에 대한 단일 객체 핸들을 얻는 부분과, 얻어진 객체핸들을 사용하여 위치 서비스에 의해 하나 이상의 컨택 주소를 얻는 부분으로 구성하였다. 주어진 모델로부터, 우리는 Naming/Trading 서비스와 위치 서비스에 의한 전체 바인딩 메커니즘의 처리과정을 나타내고, 통합 바인딩 서비스의 구성요소들에 대만 구조를 상세하게 기술하였다. 끝으로 우리의 모델을 구현하기 위해, 윈도우 운영체제와 Solaris 2.5/2.7에서 사용되는 CORBA 사양을 따르는 VisBroker 4.1과 자바 언어, SQL Server 2000 그리고 LSF를 이용하였다. 그리고 구현 환경과 구성요소에 대한 수행 화면을 보였다.ool)을 사용하더라도 단순 다중 쓰레드 모델보다 더 많은 수의 클라이언트를 수용할 수 있는 장점이 있다. 이러한 결과를 바탕으로 본 연구팀에서 수행중인 MoIM-Messge서버의 네트워크 모듈로 다중 쓰레드 소켓폴링 모델을 적용하였다.n rate compared with conventional face recognition algorithms. 아니라 실내에서도 발생하고 있었다. 정량한 8개 화합물 각각과 총 휘발성 유기화합물의 스피어만 상관계수는 벤젠을 제외하고는 모두 유의하였다. 이중 톨루엔과 크실렌은 총 휘발성 유기화합물과 좋은 상관성 (톨루엔 0.76, 크실렌, 0.87)을 나타내었다. 이 연구는 톨루엔과 크실렌이 총 휘발성 유기화합물의 좋은 지표를 사용될 있고, 톨루엔, 에틸벤젠, 크실렌 등 많은 휘발성 유기화합물의 발생원은 실외뿐 아니라 실내에도 있음을 나타내고 있다.>10)의 $[^{18}F]F_2$를 얻었다. 결론: $^{18}O(p,n)^{18}F$ 핵반응을 이용하여 친전자성 방사성동위원소 $[^{18}F]F_2$를 생산하였다. 표적 챔버는 알루미늄으로 제작하였으며 본 연구에서 연구된 $[^{18}F]F_2$가스는 친핵성 치환반응으로 방사성동위원소를 도입하기 어려운 다양한 방사성의 약품개발에 유용하게 이용될 수 있을 것이다.었으나 움직임 보정 후 영상을 이용하여 비교한 경우, 결합능 변화가 선조체 영역에서 국한되어 나타나며 그 유의성이 움직임 보정 전에 비하여 낮음을 알 수 있었다. 결론: 뇌활성화 과제 수행시에 동반되는 피험자의 머리 움직임에 의하여 도파민 유리가 과대평가되었으며 이는 이 연구에서 제안한 영상정합을 이용한 움직임 보정기법에 의해서 개선되

  • PDF