Search Result 112, Processing Time 0.028 seconds

Iterative Target Localization Method for Distributed MIMO Radar System (반복적 연산을 이용하는 Distributed MIMO 레이다 시스템의 위치 추정 기법)

  • Shin, Hyuksoo;Chung, Young-Seek;Yang, Hoon-Gee;Kim, Jong-mann;Chung, Wonzoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.10
    • /
    • pp.819-824
    • /
    • 2017
  • This paper presents a target localization scheme for distributed Multi-input Multi-output(MIMO) radar system using ToA measurements obtained from multiple transmitter and receiver pairs. The proposed method can locate the target from an arbitrary initial point by iteratively finding the Taylor linear approximation equation. The simulation results show that proposed method achieves the better mean square error(MSE) performance than the existing target localization methods, and furthermore, attains Cramer-Rao Lower Bound(CRLB).

A Study on Multi Sensor Track Fusion Algorithm for Naval Combat System (함정 전투체계 표적 융합 정확도 향상을 위한 알고리즘 연구)

  • Jung, Young-Ran
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.34-42
    • /
    • 2007
  • It is very important for the combat system to process extensive data exactly at short time for the better situation awareness compared with the threats in these days. This paper suggests to add radial velocity on the decision factor of sensor data fusion in the existing algorithm for the accuracy enhancement of the sensor data fusion in the combat system.

Implementation of Intelligent Moving Target Tracking and Surveillance System Using Pan/Tilt-embedded Stereo Camera System (팬/틸트 탑제형 스테레오 카메라를 이용한 지능형 이동표적 추적 및 감시 시스템의 구현)

  • 고정환;이준호;김은수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.4C
    • /
    • pp.514-523
    • /
    • 2004
  • In this paper, a new intelligent moving target tracking and surveillance system basing on the pan/tilt-embedded stereo camera system is suggested and implemented. In the proposed system, once the face area of a target is detected from the input stereo image by using a YCbCr color model and then, using this data as well as the geometric information of the tracking system, the distance and 3D information of the target are effectively extracted in real-time. Basing on these extracted data the pan/tilted-embedded stereo camera system is adaptively controlled and as a result, the proposed system can track the target adaptively under the various circumstance of the target. From some experiments using 80 frames of the test input stereo image, it is analyzed that standard deviation of the position displacement of the target in the horizontal and vertical directions after tracking is kept to be very low value of 1.82, 1.11, and error ratio between the measured and computed 3D coordinate values of the target is also kept to be very low value of 0.5% on average. From these good experimental results a possibility of implementing a new real-time intelligent stereo target tracking and surveillance system using the proposed scheme is finally suggested.

A Study for Assessment of Track Accuracy of Phased Array Radar Associated with α-β Filter (α-β 필터를 사용한 위상배열 레이더의 실표적 추적 정확도 평가 알고리듬 연구)

  • Shin, Sang-Jin;Kim, Wan-Gyu
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.9
    • /
    • pp.828-836
    • /
    • 2015
  • In this paper, the assessment technique for track accuracy in the phased array radar is proposed. It is assumed that ${\alpha}-{\beta}$ tracking filter to track the target is established in the phased array radar. In order to assess the track accuracy strictly, we should use the real target position data acquired from the special instrument, ACMI(Air Combat Maneuvering Instrument) pod or DGPS(Differential Global Positioning System). However, this method leads to increase the experiment cost and test time. We derive the relationship between the residuals of tracking filter and the standard deviations of range and angle tracking errors which are assigned as track assessment index. The theory of sample variance is introduced in this assessment because track accuracy has to be calculated with many residual samples.

Comparison of Multi-Static Sonar Target Positioning Performance (다중상태 소나망 위치 추정 성능 비교)

  • Park, Chee-Hyun;Ko, Han-Seok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.4
    • /
    • pp.166-172
    • /
    • 2007
  • In this paper, we address the target positioning performance of Multi-Static sonar with respect to target positioning method and measurement error. Based on the analysis on two candidate solution approaches, namely, Least Square (LS) using range and angular information simultaneously and Maximum Likelihood (ML) using only range information as the existing information fusion methods for possible application to Multi-Static sonar, we propose to employ ML using range and angular information. Assuming that each sensor can receive range and angular information, we conduct representative comparison experiments over the existing and proposed methods under various measurement noise scenarios. We also investigate the target positioning performance according to number of sensors, distance between transmitter and receiver. According to the experimental results, RMSE of the proposed ML with distance and direction information is found to be more superior to ML using distance alone and to LS in case distance between transmitter and receiver is longer and number of receiver is smaller.

Accuracy in target localization in stereotactic radiosurgery using diagnostic machines (정위적 방사선수술시 진단장비를 이용한 종양위치결정의 정확도 평가)

  • 최동락
    • Progress in Medical Physics
    • /
    • v.7 no.1
    • /
    • pp.3-7
    • /
    • 1996
  • The accuracy in target localization of CT, MR, and digital angiography were investigated for stereotactic radiosurgery. The images using CT and MR were obtained out of geometrical phantom which was designed to produce exact coordinates of several points within a 0.lmm error range. The slice interval was 3mm and FOV was 35cm for CT and 28cm for MR. These images were transferred to treatment planning computer using TCP/IP in forms of GE format. Measured 3-D coordinates of these images from planning computer were compared to known values by geometrical phantom. Anterior-posterior and lateral films were taken by digital angiography for measurement of spatial accuracy. Target localization errors were 1.2${\pm}$0.5mm with CT images, 1.7${\pm}$0.4mm with MR-coronal images, and 2.1${\pm}$0.7mm with MR-sagittal images. But, in case of MR-axial images, the target localization error was 4.7${\pm}$0.9mm. Finally, the target localization error of digital angiography was 0.9${\pm}$0.4mm. The accuracy of diagnostic machines such as CT, MR, and angiography depended on their resolutions and distortions. The target localization error mainly depended on the resolution due to slice interval with CT and the image distortion as well as the resolution with MR However, in case of digital angiography, the target localization error was closely related to the distortion of fiducial markers. The results of our study should be considered when PTV (Planning Target Volume) was determined.

  • PDF

Selection of Signal Strength and Detection Threshold for Optimal Tracking with Nearest Neighbor Filter (NN 필터 추적을 위한 최적 신호 강도 및 검출 문턱값 선택)

  • Jeong, Yeong-Heon;Gwon, Il-Hwan;Hong, Sun-Mok
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.3
    • /
    • pp.1-8
    • /
    • 2000
  • In this paper, we formulate an optimal control problem to obtain the optimal signal strength and detection threshold for tracking with NN filter, First, we predict the tracking performance of NN filter by using the HYCA method. Based on this method, the predicted tracking performance is represented with respect to signal strength and detection threshold. Using this relation, we find the optimal parameters for following three examples: 1) the sequence of optimal detection threshold which minimizes sum of position estimation error; 2) the sequence of optimal detection threshold which minimizes sum of validation gate volume; and 3) the sequence of optimal signal strength and detection threshold which minimizes sum of signal strength.

  • PDF

Improved Method to Select Targets in Phase Gradient Autofocus on Real Time Processing (실시간 처리를 위한 PGA 표적 선택기법 개선)

  • Lee, Hankil;Kim, Donghwan;Son, Inhye
    • The Journal of Korean Institute of Information Technology
    • /
    • v.17 no.10
    • /
    • pp.57-63
    • /
    • 2019
  • Motion errors which are caused by several reasons, non-ideal path, errors of navigation systems, and radar system errors, have to be corrected. Motion compensation methods can compensate the motion error, but not exactly. To correct these residual errors, several autofocus methods are invented. A popular method is phase gradient autofocus (PGA). PGA does not assume specific circumstances, such as isolated point targets and shapes of errors. PGA is an iterative and adaptive method, so that the processing time is the main problem for the real time processing. In this paper, the improved method to select targets for PGA is proposed to reduce processing time. The variances of image pixels are used to select targets with high SNR. The processing of PGA with these targets diminishes the processing time and iterations effectively. The processed results with real radar data, obtained by flight tests, show that the proposed method compensates errors well, and reduce working time.

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF

An accuracy analysis of Cyberknife tumor tracking radiotherapy according to unpredictable change of respiration (예측 불가능한 호흡 변화에 따른 사이버나이프 종양 추적 방사선 치료의 정확도 분석)

  • Seo, jung min;Lee, chang yeol;Huh, hyun do;Kim, wan sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.157-166
    • /
    • 2015
  • Purpose : Cyber-Knife tumor tracking system, based on the correlation relationship between the position of a tumor which moves in response to the real time respiratory cycle signal and respiration was obtained by the LED marker attached to the outside of the patient, the location of the tumor to predict in advance, the movement of the tumor in synchronization with the therapeutic device to track real-time tumor, is a system for treating. The purpose of this study, in the cyber knife tumor tracking radiation therapy, trying to evaluate the accuracy of tumor tracking radiation therapy system due to the change in the form of unpredictable sudden breathing due to cough and sleep. Materials and Methods : Breathing Log files that were used in the study, based on the Respiratory gating radiotherapy and Cyber-knife tracking radiosurgery breathing Log files of patients who received herein, measured using the Log files in the form of a Sinusoidal pattern and Sudden change pattern. it has been reconstituted as possible. Enter the reconstructed respiratory Log file cyber knife dynamic chest Phantom, so that it is possible to implement a motion due to respiration, add manufacturing the driving apparatus of the existing dynamic chest Phantom, Phantom the form of respiration we have developed a program that can be applied to. Movement of the phantom inside the target (Ball cube target) was driven by the displacement of three sizes of according to the size of the respiratory vertical (Superior-Inferior) direction to the 5 mm, 10 mm, 20 mm. Insert crosses two EBT3 films in phantom inside the target in response to changes in the target movement, the End-to-End (E2E) test provided in Cyber-Knife manufacturer depending on the form of the breathing five times each. It was determined by carrying. Accuracy of tumor tracking system is indicated by the target error by analyzing the inserted film, additional E2E test is analyzed by measuring the correlation error while being advanced. Results : If the target error is a sine curve breathing form, the size of the target of the movement is in response to the 5 mm, 10 mm, 20 mm, respectively, of the average $1.14{\pm}0.13mm$, $1.05{\pm}0.20mm$, with $2.37{\pm}0.17mm$, suddenly for it is variations in breathing, respective average $1.87{\pm}0.19mm$, $2.15{\pm}0.21mm$, and analyzed with $2.44{\pm}0.26mm$. If the correlation error can be defined by the length of the displacement vector in the target track is a sinusoidal breathing mode, the size of the target of the movement in response to 5 mm, 10 mm, 20 mm, respective average $0.84{\pm}0.01mm$, $0.70{\pm}0.13mm$, with $1.63{\pm}0.10mm$, if it is a variant of sudden breathing respective average $0.97{\pm}0.06mm$, $1.44{\pm}0.11mm$, and analyzed with $1.98{\pm}0.10mm$. The larger the correlation error values in both the both the respiratory form, the target error value is large. If the motion size of the target of the sine curve breathing form is greater than or equal to 20 mm, was measured at 1.5 mm or more is a recommendation value of both cyber knife manufacturer of both error value. Conclusion : There is a tendency that the correlation error value between about target error value magnitude of the target motion is large is increased, the error value becomes large in variation of rapid respiration than breathing the form of a sine curve. The more the shape of the breathing large movements regular shape of sine curves target accuracy of the tumor tracking system can be judged to be reduced. Using the algorithm of Cyber-Knife tumor tracking system, when there is a change in the sudden unpredictable respiratory due patient coughing during treatment enforcement is to stop the treatment, it is assumed to carry out the internal target validation process again, it is necessary to readjust the form of respiration. Patients under treatment is determined to be able to improve the treatment of accuracy to induce the observed form of regular breathing and put like to see the goggles monitor capable of the respiratory form of the person.

  • PDF