• 제목/요약/키워드: 표면복사

검색결과 240건 처리시간 0.02초

고출력 LED 램프 용 방사형 히트싱크의 형상 및 표면코팅이 LED 냉각성능에 미치는 영향에 대한 연구 (THE EFFECTS OF RADIAL HEAT SINK GEOMETRY AND SURFACE COATINGS ON THE LED COOLING PERFORMANCE FOR HIGH POWER LED LAMP)

  • 김효성;박상희;김동주;김경진
    • 한국전산유체공학회지
    • /
    • 제18권1호
    • /
    • pp.63-68
    • /
    • 2013
  • The purpose of this study is to investigate the cooling performance of radial heat sink used for high power LED lightings by natural convection cooling with surrounding air. Experimental and numerical analyses are carried out together. Parametric studies are performed to compare the effects of geometric parameters in radial heat sink such as the number of fins, fin height, fin length, and thickness of fin base as well as the surface coatings of radial heat sink. In this study, the cooling of 60 W LED lamp is examined with radiative heat transfer considered as well as natural convection. Numerical results show the optimum condition when the number of fin is 40, heat sink height is 120 mm, fin length is 15 mm, and fin base thickness is 3 mm. The difference in temperature of the LED metal PCB is within $1^{\circ}C$ between numerical analyses and experimental results. Also, the CNT coating on the heat sink surface is found to increase the cooling performance significantly.

인공위성 원격탐사를 이용한 대기보정 기술 고찰 (A Review on Atmospheric Correction Technique Using Satellite Remote Sensing)

  • 이권호;염종민
    • 대한원격탐사학회지
    • /
    • 제35권6_1호
    • /
    • pp.1011-1030
    • /
    • 2019
  • 인공위성 또는 항공기에서 사용되는 원격탐사용 센서는 지구 대기를 통과하는 전자기파를 측정하므로, 지구 대기에 의하여 흡수 또는 산란되는 과정에서 지표면의 정보가 영향을 받게 된다. 인공위성은 탑재센서의 사용목적에 따라 파장범위, 해상도가 다르지만, 공통적으로 지구 표면의 대상의 분광신호를 정확히 측정하기 위하여 대기에 의한 영향을 제거해야 하는 대기보정이 이루어져야 한다. 대기보정의 목적은 원격탐사 영상에서 대기 효과를 제거하여 지표면 반사도 값을 결정하고 지표면의 물리적 매개 변수를 도출하는 것이다. 현재까지 개발된 대기보정 알고리즘은 영상기반의 경험적인 방법 또는 현지 관측 자료를 이용한 간접적인 보정 방법에서 보다 복잡한 복사전달과정을 수치해석적으로 해석하는 직접적인 보정 방법으로 발전해 왔다. 본 연구는 지난 40여년 동안 개발된 대기보정 알고리즘에 대한 연구 기록을 분석함으로써, 대기보정 기술의 현황 및 주요 대기보정 알고리즘에 대한 연구 결과를 체계적으로 정립하여 관련 기술의 현황 및 연구동향을 제시하였다.

열간 압연공정의 강판 온도 분포 해석 (Bar Temperature Analysis of a Hot Rolling Process.)

  • 백기남;고명삼
    • 대한전기학회논문지
    • /
    • 제38권4호
    • /
    • pp.307-315
    • /
    • 1989
  • 본 논문에서는 열간압연공정중 소재가 가열로에서 추출되어 조압연 공정을 마치기 까지 소재인 slab의 온도변화추이를 해석키 위하여 rolling process 상에서 온도에 영얄을 미치는 인자인 1) 대기중 복사 및 대류에 의한 냉각 2) 소성가공발열 3) descaling water에 의한 수냉각 4) rolling roll, 운반 roll과의 접촉냉각등 제요인에 관한 사항을 rolling process 상에서의 문제로 평가도입하여 해석하고저 하는 slab 표면에서의 경계조건 설정과 관련한 적용기법을 정립하였고 소재의 냉각 현상을 two dimensional transient heat flow문제로 취급, 유한차분방정식을 이용하여 해석하는 과정과 관련 rollinh작업을 sequence화 하여 적용하는 기법을 제시하였다. simulation 결과 계산치와 실계측편차 (${\pm}18^{\circ}C$)범위내에서 일치함을 제시하였고 또한 rolling event 별로 나타나는 온도하강 pattern이 실제의 압연상황과 잘 일치함을 제시하므로서 본 computer simulation 과정에서 적용한 가정, 조건, 물성치 등의 적정성 등을 입증하였다.

태양열 이용 냉난방 공조시스템중 평판형 집열기의 동계 상부 열손실 해석 (Analysis of the Top Loss Coefficient for Flat Plate Collector in a Solar Air-Conditioning System during Winter)

  • 김보철;최광환;금종수;김종렬
    • 태양에너지
    • /
    • 제18권3호
    • /
    • pp.15-24
    • /
    • 1998
  • 태양열 집열기의 열손실은 크게 3가지 즉 상부 열손실, 하부 열손실, 측부 열손실로 대별되나 단열이 양호한 집열기에서는 일반적으로 측면으로의 열손실은 무시한다. 측부 열손실을 제외한 두 열손실 중에서도 상부 열손실은 집열기의 대부분의 열손실을 차지하는 지배적인 요소이다. 따라서 태양열 집열기의 집열 성능을 정확하게 파악하기 위해서는 상부 열손실 계수를 정확하게 계산할 필요가 있다. 본 연구에서 사용한 평판형 태양열 집열기(재생기)는 하계에는 제습 및 냉방을 행하고 동계에는 난방을 행하는 전천후 집열판으로 제작되었다. 따라서 장치의 전환없이 겨울에 난방용으로 사용하였을 경우의 집열 성능을 파악하기 위하여 옥외에서 실험을 하였다. 동계 기간 실험을 통하여 본 집열기의 상부 열손실 계수는 약 $3{\sim}4.5W/m^2^{\circ}C$임을 알 수 있었다. 그리고 집열표면에 선택흡수막을 입혀서 난방용으로 사용하면 주위와의 복사 열손실을 크게 줄일 수 있기 때문에 본 집열기의 집열 성능을 향상시킬 수 있을 것으로 사료된다.

  • PDF

수직평행채널의 벽면에 부착된 단일모듈로부터의 3차원 자연대류 열전달 (Three-Dimensional Natural Convection from a Single Module on the Wall of a Vertical Parallel-Plate Channel)

  • 유갑종;이진호;김현우
    • 태양에너지
    • /
    • 제19권3호
    • /
    • pp.29-41
    • /
    • 1999
  • 본 연구에서는 돌출된 단일 모듈이 부착된 수직 채널내의 3차원 자연대류 특성을 실험적으로 조사하였으며, 특히 모듈로부터 대류에 의한 열에너지 제거에 초점을 두었다. 채널내의 유동장은 smoke-method를 이용하여 가시화 하였다. 또한 채널내부, 수직벽면 및 모듈표면의 국소온도를 열전대와 열플럭스 센서를 이용하여 측정하여 복사와 전도에의한 열손실량을 계산하였다. 실험결과 대류열전달은 모듈 하부의 모서리 부근에서 가장 활발히 일어나고, 모듈 상부에서의 재순환영역은 열전달을 감소시킴을 알 수 있으며 임계 채널간격비를 예측할 수 있는 상관식을 레일리히수의 함수로 구하였다. 또한 $8.28{\times}10^3<Ra^*_c<3.48{\times}10^6$의 범위에서 수정 채널 레일리히수의 함수로써 평균 누셀트수와의 상관식을 구하였다.

  • PDF

외복사근과 다열근에 대한 초음파 영상과 표면 근전도 측정방법의 신뢰도와 타당도 (Reliability and Validity of Ultrasound Imaging and sEMG Measurement to External Abdominal Oblique and Lumbar Multifidus Muscles)

  • 김창용;최종덕;김선엽;오덕원;김진경
    • 한국전문물리치료학회지
    • /
    • 제18권1호
    • /
    • pp.37-46
    • /
    • 2011
  • The purpose of this study was to investigate intra-rater reliability and determine the validity of electromyography (EMG) measurements to represent muscle activity and ultrasonography (US) to represent muscle thickness during manual muscle testing (MMT) to external abdominal oblique (EO) and lumbar multifidus (MF). Twenty healthy subjects were recruited for this study and asked to perform MMT at differing levels. The subjects' muscle activity using EMG was measured by a ratio to maximum voluntary contraction (MVC) and root mean square (RMS) methods. The subjects' muscle thickness using US was measured by raw muscle thickness and change ratio of thickness to maximum (MVC) or resting condition. In three trials, measurements were performed on each subject by one examiner. The intra-rater reliability of measurements of EMG and US to EO and MF was calculated using intra-class coefficients. The intra-rater reliability of all measurements was excellent (ICC=.75~.98) in EMG and US. The conduct validity was calculated by one-way ANOVA with repeated measurements to compare whether the EMG and US measurements were different between MMT at different levels. There was only a significant difference between all grades at %MVC thickness measurement of US. These results suggest that a %MVC thickness measurement of US was a more sensitive and discriminate in all manual muscle testing grades. This information will be useful for the selection of US measurement and analysis methods in clinics.

분광분석을 활용한 고에너지 레이저 환경에서의 알루미늄-산소 화학반응 연구 (The spectroscopic study of chemical reaction of laser-ablated aluminum-oxygen by high power laser)

  • 김창환
    • 한국항공우주학회지
    • /
    • 제44권9호
    • /
    • pp.789-795
    • /
    • 2016
  • 이차 추진제로 많이 쓰이는 알루미늄을 고출력 레이저를 조사하여 공기 중의 산소와 반응시켜 발생되는 알루미늄과 산소의 화학 반응을 레이저 분광분석법을 이용하여 연구를 수행 하였다. 7ns의 펄스 주기와 1064nm의 주파수를 가진 Q-switched Nd:YAG 레이저로 40 - 2500mJ($6.88{\times}10^{10}-6.53{\times}10^{11}W/cm^2$)의 에너지가 공급되었으며, 플라즈마 빛은 echelle 회절 분광기와 ICCD 카메라로 감지하였다. 분광분석을 통하여 알루미늄과 산소의 원자/분자 신호 분석과 현상이 일어나는 플라즈마 환경의 특성 연구를 위해 들뜸 온도(2200K~6600K) 및 전자밀도($3.15{\times}10^{15}{\sim}2.38{\times}10^{16}cm^{-3}$) 계산, 그리고 알루미늄 표면의 크레이터(Crater) 분석을 수행하였다. 본 연구는 고 레이저 복사 조도 환경하에서 발생되는 화학 반응과 플라즈마의 특성을 파악하는 방법을 제시하고 있다.

토지이용 유형별 공간특성을 고려한 ENVI-met 모델의 현장측정자료 기반의 검증 (Validation of ENVI-met Model with In Situ Measurements Considering Spatial Characteristics of Land Use Types)

  • 송봉근;박경훈;정성관
    • 한국지리정보학회지
    • /
    • 제17권2호
    • /
    • pp.156-172
    • /
    • 2014
  • 본 연구는 미기후 분석 프로그램인 ENVI-met 모델의 정확도를 검증하기 위해 경상남도 창원시를 대상으로 도시지역의 주요 토지이용 유형별 공간특성을 고려하여 선정된 조사구역의 현장측정 기상자료와 비교하였다. 현장측정은 주간시간대 2일, 야간시간대 1일 총 3일간이동식으로 측정하였고, ENVI-met 모델링은 현장측정과 동일한 시간대로 설정하여 수행하였다. 측정항목별 분석결과에 따르면, 주간시간대의 순복사에너지는 ENVI-met 모델링이 현장측정값보다 약 $300Wm^{-2}$ 정도 높았고, 야간시간대는 현장측정값이 $200Wm^{-2}$ 정도 더 높았다. 기온은 주간 및 야간 시간대 모두 현장 측정값이 약 $3{\sim}6^{\circ}C$ 정도 더 높은 것으로 분석되었다. 표면온도도 현장측정값이 ENVI-met 모델링보다 약 $7{\sim}13^{\circ}C$ 더 높았다. 풍속은 ENVI-met 모델링과 현장측정값 간의 차이가 매우 큰 것으로 나타났다. 회귀분석 결과에서는 기온자료의 $R^2$값이 약 0.6정도로 비교적 높게 나타난 반면에, 나머지 순복사에너지와 표면온도, 풍속은 낮은 상관성을 보였다. 이는 ENVI-met 모델링이 태양 및 지구복사에너지를 과대 또는 과소 예측하고 있으며, 모델링 및 현장측정을 위해 선정된 조사구역들을 둘러싸고 있는 인접한 주변 지역의 공간구조적, 미기후적 특성 차이에 의한 영향으로 판단된다. 따라서 향후 이에 대한 보다 면밀한 실증적 연구가 필요할 것으로 판단된다.

코밍 노출면 방열 두께 및 비 노출면 방열 길이 변화에 따른 방화 댐퍼의 내화성능에 관한 실험적 연구 (An experimental study on the fireproof performance of fire damper according to change of the insulation conditions on the exposed side and unexposed side of the coaming)

  • 최태진;김정식;임영수;이경현;강호근;박성호;김유택
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권1호
    • /
    • pp.99-104
    • /
    • 2014
  • 본 논문에서는 탄화수소화재 조건에 따른 방화 댐퍼의 내화성능 평가에 대한 선행논문 실험체 -1(126 mm, $136^{\circ}C$)에 대하여 H-120 등급 방열성 확보가 가능한 최적의 코밍 방열 조건을 도출 하고자 노출면 코밍 방열 두께와 비 노출면 코밍 방열 길이 변화를 변수로 하여 내화실험을 수행 하였다. 내화실험 결과 실험체-2(88 mm, $171^{\circ}C$)는 H-120 방열성 허용기준을 만족하였으나, 실험체-3(50 mm, $185^{\circ}C$)은 110분에 방열성능 허용기준을 초과하는 것으로 나타나 실험체-2의 방열 조건이 실험체-1로부터 경량화가 가능한 최적의 방열 조건으로 확인 되었으며, 온도상승에 대한 비교결과 노출면 코밍 방열두께가 감소될 경우 방열재 표면온도는 격벽을 통한 전도열에 의한 영향 크며, 코밍 표면온도는 블레이드와 노출면 코밍으로부터 방사되는 복사열에 의한 영향이 큰 것으로 판단된다.

과열에 의해 발화된 동물성 식품의 화염 및 탄화 패턴에 관한 연구 (Flame and Carbonization Patterns of Animal-Origin Foods Ignited by Overheating)

  • 이정훈;최충석
    • 한국화재소방학회논문지
    • /
    • 제33권6호
    • /
    • pp.126-131
    • /
    • 2019
  • 과열방지장치가 없는 가스레인지를 이용하여 동물성 식품의 실물 화재 실험을 실시하였다. 동물성 식품의 연소 초기에는 흰색의 연기와 수증기가 다량 발생했으나 물기가 없어지고 동물성 식품의 탄화가 시작되면 검정색 연기가 발생하였다. 가스레인지의 과열 시간이 5,400 s가 경과되어도 고등어, 명태 및 닭고기 등은 착화되지 못했다. 그러나 돼지고기는 2,643 s, 쇠고기는 2,819 s, 참치는 6,492 s에서 발화되는 것을 확인하였다. 동물성 식품의 화염 패턴은 층류와 난류가 혼합된 형태이며, 달무리 패턴(Halo Pattern)이 발생하는 것을 알 수 있었다. 주방 후드가 작동할 때의 화염은 모래시계 패턴을 형성하였고, 주방 후드가 작동하지 않을 때는 삼각형 패턴을 나타냈다. 냄비에 담긴 참치가 과열되면 6,492 s에 자연발화 되었고, 주방 후드의 표면 온도는 464.5 ℃로 급격히 상승하였다. 그리고 냄비 상부의 바깥 표면으로부터 6 cm 이격된 냄비 후면의 온도는 6,660 s에 복사열로 인해 869 ℃로 측정되었다. 화염에 의해 소손된 주방 벽면에는 모래시계 패턴이 형성되었으며, 주방 후드가 작동하지 않거나 천장 높이보다 화염이 작게 성장할 때는 삼각형 패턴을 나타내는 것이 확인되었다.