• Title/Summary/Keyword: 폴리머코팅

Search Result 208, Processing Time 0.019 seconds

Interaction of Bone Marrow Stromal Stem Cells with Adhesive Protein and Polypeptide-adsorbed Poly(lactide-co-glycolide) Scaffolds (골수유래 간엽줄기세포와 점착성 단백질 및 폴리펩타이드가 흡착된(락티이드/글리콜라이드) 공중합체 지지체와의 상호작용)

  • Choi, Jin-San;Lee, Sang-Jin;Jang, Ji-Wook;Khang, Gil-Son;Lee, Young-Moo;Lee, Bong;Lee, Hai-Bang
    • Polymer(Korea)
    • /
    • v.27 no.5
    • /
    • pp.397-404
    • /
    • 2003
  • The interaction of cell adhesive protein and polypeptide with bone marrow stromal stem cells (BMSCs) grown in tissue engineered films and scaffolds were examined. Several proteins or polypeptide known as cell-adhesive were coated adsorption on poly(lactide-co-glycolide) (PLGA) films and scaffolds and adhesion and proliferation behavior of BMSC on those surfaces were compared. The protein and polypeptide used include collagen IV, fibrinogen, laminin, gelatin, fibronectin, and poly(L-lysine). The protein and polypeptide were adsorbed on the PLGA film surfaces with almost monolayer coverage except poly(L-lysine). BMSCs were cultured for 1, 2, and 4 days on the protein- or polypeptide-adsorbed PLGA films and scaffolds. The cell adhesion and proliferation behaviors were assessed by sulforho damine B assay. It was observed that the protein- or polypeptide-adsorbed surfaces showed better cell adhesion and proliferation than the control.

Physical Properties of Covered Stent in Gastric Acid Environment: In Vitro Study (위산 환경에서 피막형 스텐트의 물성 변화)

  • Park, Sung Chul;Park, Nark-Soon;Kim, Dong-Gon;Nah, Jae-Woon;Jeen, Yoon Tae;Cho, Hye Jin;Kim, Eun Sun;Keum, Bora;Seo, Yeon Seok;Lee, Hong Sik;Chun, Hoon Jai;Um, Soon Ho;Kim, Chang Duck;Ryu, Ho Sang
    • Polymer(Korea)
    • /
    • v.38 no.3
    • /
    • pp.351-357
    • /
    • 2014
  • In membrane covered stent, occlusion and fracture from membrane degradation by gastric acid sometimes occurred. Therefore, we investigated the physical properties of membrane covered stent according to its ingredient and concentration in gastric acid environment. Membrane covered stents consisted of silicone and polyurethane with 15%, 18%, 20% concentrations were used. After incubating stents in a condition of pH 1.2, we checked any changes at every 3 weeks for 18 weeks. The changes of membrane surface, radial expansion and recovery force of stent were investigated. Coating thickness increased proportionally to an increase in ingredient concentration. Surface was evenly coated with silicone compared to the case with polyurethane and its homogeneity was excellent in a high concentration. Degradation was much severe in the case of polyurethane. The radial force of silicone was higher than polyurethane, and the decrease of radial and recovery force was higher in the case of polyurethane. In conclusion, high concentration of silicone membrane was more stable than polyurethane in acid environment of in vitro study.

Fabrication and Characterization of UV-curable Conductive Transparent Film with Polyaniline Nanofibers (폴리아닐린 나노섬유를 이용한 광경화형 전도성 투명필름의 제조 및 특성)

  • Kim, Sung-Hyun;Song, Ki-Gook
    • Polymer(Korea)
    • /
    • v.36 no.4
    • /
    • pp.531-535
    • /
    • 2012
  • Conductive polyaniline (PANI) nanofibers in UV-curable resin were used for a transparent conductive film. The emeraldine-salt PANI (ES-PANI) nanofibers were prepared by chemical oxidation polymerization of aniline, which could be changed into emeraldine-base PANI by dedoping. EB-PANI nanofibers as a precursor for conductive fillers were thereby transformed into re-dpoed PANI (rES-PANI) by dodecylbenzenesulfonic acid in the UV-curable resin solution. rES-PANI nanofibers have high conductivity and long-term stability in the solution without a defect of nanostructure. The resulting conductive resin solution was proved to be highly stable where no precipitation of rES-PANI fillers was observed over a period of 3 months. The transparent film was spin-casted on a poly(methyl methacrylate) sheet of thickness ca. $5{\mu}m$. A surface resistance of $6.5{\times}10^8{\Omega}/sq$ and transmittance at 550 nm of 91.1% were obtained for the film prepared with a concentration of 1.4 wt% rES-PANI nanofibers in the solution. This transformation process of rES-PANI from ES-PANI by dedoping-redoping can be an alternative method for the preparation of an antistatic protection film with controllable surface resistance and optical transparencies with the PANI concentration in UV-curable solution.

Synthesis and Water Repellency of Polymers with Fluorinated Alkyl Group and Isocyanate Group (불소화 알킬기와 이소시아네이트기를 가지는 고분자의 합성과 발수성)

  • Baek Chang-Hoon;Kong Jong-Yun;Hyun Seok-Hee;Lim Yong-Jin;Kim Woo-Sik
    • Polymer(Korea)
    • /
    • v.29 no.5
    • /
    • pp.433-439
    • /
    • 2005
  • The copolymers were prepared by the emulsion copolymerization of fluoroalky lacrylate-stearylacrylate-m-isopropenyl-${\alpha},\;{\alpha}'$-dimethylbenzyl isocyanate (TMI) in order to obtain water repellent polymers. The respective copolymerization rates of the three monomers considerably depended upon the use of the nonionic emulsifier and the nonionic-cationic mixed emusifier, and the optimum conditions were obtained. The particle sizes of the copolymers were in the range of 105 to 222nm. The particle sizes of the copolymers prepared by the use of the mixed emulsifiers were smaller than those of the copolymers prepared by the use of the nonionic emulsifier. The reactions of both TMI-N-methyl acetamide and TMI-cellobiose did not take place. However, the reaction of TMI-n-butylamine occurred. The water contact angles before and after washing three times for nylon and poly(ethylene terephthalate) (PET) fabrics coated with the copolymer prepared by the use of mixed emulsifier were about $139^{\circ}\;and\;133^{\circ}$ Therefore, the copolymer showed good durable repellency for nylon and PET.

Synthesis and Characterization of Polyamide Having Photoreactive Group in the Backbone and its Liquid Crystal Aligning Property (광반응성 작용기를 주사슬에 갖는 폴리아미드의 합성과 특성 분석 및 액정분자의 배향 특성)

  • Jung, Eun-Young;Lee, Tae-Jin;Lee, Seung-Woo
    • Polymer(Korea)
    • /
    • v.35 no.4
    • /
    • pp.350-355
    • /
    • 2011
  • A soluble polyamide containing photosensitive l,4-phenylenediacrylic acid (PDA) in main chain with biphenyl moiety was synthesized. The chemical structure of synthesized polyamide was investigated by means of $^1H$ NMR spectroscopy. The polymer was stable up to $280^{\circ}C$ and soluble in organic solvents, giving a good quality of thin films. The photoreaction of unpolarized LTV irradiated films was investigated by means of UV-vis absorption spectroscopy and FTlR spectroscopy, and liquid crystals (LCs) alignment property was examined by exposing to linearly polarized UV light (LPUVL) of 260~380 nm. The polyamide in film has excellent photoreactivity to unpolarized UV light. Direction selective photoreaction of PDA moiety in Lhe film was found to further induce nematic liquid -crystals to align along a perpendicular direction with respect to the electric vector of LPUVL, regardless of exposure energy of LPUVL. In addition, pretilt angle was measured by means of crystal rotation method. LPUVL-exposed polymer film induced the alignment of liquid-crystals (LC) with a pretilt angle of 0.2~$0.5^{\circ}$.

Effect of Drug Eluting Uniformity for Biodegradable Stent by Solid Freeform Fabrication (쾌속조형기법을 이용한 생분해성 스텐트용 메쉬필름의 약물방출거동 효과)

  • Cheong, Sin Young;Kim, Yang Eun;Koh, Young Joo;Shin, Wang Soo;Lee, Jun Hee;Kim, Wan Doo;Yoo, Young Eun;Park, Su A
    • Polymer(Korea)
    • /
    • v.38 no.1
    • /
    • pp.93-97
    • /
    • 2014
  • Biodegradable drug-eluting stent has dual functions of supporting the lumen and treating internal tumor preventing the restenosis by releasing drug. In this study, the polycaprolactone (PCL) based three dimensional (3D) mesh loaded with paclitaxel (PTX) was presented by rapid prototyping (RP) technique of solid freeform fabrication (SFF) for biodegradable drug-eluting stent application. PCL has many advantageous properties such as good biocompatibility, good mechanical properties, and good drug permeability. PTX is widely used in the cancer treatment by inhibiting tumor cell proliferation. Analytical methods of HPLC and NMR were used for simultaneous quantification of PTX. Scanning electron microscopy (SEM) was performed to observe the architecture and morphologies of 3D mesh. The cytotoxicity assay results indicated released PTX's biological activity. This study provided that PCL based 3D mesh loaded with PTX by RP technique has great potential for biodegradable drug-eluting stent application.

Cell-cultivable ultrasonic transducer integrated on glass-coverslip (세포 배양 가능한 커버슬립형 초음파 변환자)

  • Keunhyung Lee;Jinhyoung Park
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.412-421
    • /
    • 2023
  • Ultrasound brain stimulation is spot-lighted by its capability of inducing brain cell activation in a localized deep brain region and ultimately treating impaired brain function while the efficiency and directivity of neural modulation are highly dependent on types of stimulus waveforms. Therefore, to optimize the types of stimulation parameters, we propose a cell-cultivable ultrasonic transducer having a series stack of a spin-coated polymer piezoelectric element (Poly-vinylidene fluoride-trifluorethylene, PVDF-TrFE) and a parylene insulating layer enhancing output acoustic pressure on a glass-coverslip which is commonly used in culturing cells. Due to the uniformity and high accuracy of stimulus waveform, tens of neuronal cell responses located on the transducer surface can be recorded simultaneously with fluorescence microscopy. By averaging the cell response traces from tens of cells, small changes to the low intensity ultrasound stimulations can be identified. In addition, the reduction of stimulus distortions made by standing wave generated from reflections between the transducers and other strong reflectors can be achieved by placing acoustic absorbers. Through the proposed ultrasound transducer, we could successfully observe the calcium responses induced by low-intensity ultrasound stimulation of 6 MHz, 0.2 MPa in astrocytes cultured on the transducer surface.

CLINICAL STUDY OF SHADE IMPROVEMENT AND SAFETY OF POLYMER-BASED PEN TYPE BlancTis Forte WHITENING AGENT CONTAINING 8.3% CARBAMIDE PEROXIDE (8.3% Carbamide Peroxide 함유 펜 형 자가미백제인 BlancTis Forte의 색조개선 및 안전성에 관한 임상연구)

  • Lee, Jin-Kyung;Min, Sun-Hong;Hong, Sung-Tae;Oh, So-Ram;Chung, Shin-Hye;Hwang, Young-Hye;You, Sung-Yeop;Bae, Kwang-Shik;Baek, Seung-Ho;Lee, Woo-Cheol;Son, Won-Jun;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.154-161
    • /
    • 2009
  • This clinical study evaluated the whitening effect and safety of polymer based-pen type BlancTis Forte (NIBEC) containing 8.3% carbamide peroxide. Twenty volunteers used the BlancTis Forte whitening agent for 2 hours twice a day for 4 weeks. As a control. Whitening Effect Pen (LG) containing 3% hydrogen peroxide was used by 20 volunteers using the same protocol. The change in shade (${\Delta}E^*$, color difference) was measured using $Shadepilot^{TM}$ (DeguDent) before, during, and after bleaching (2 weeks, 4 weeks, and post-bleaching 4 weeks). A clinical examination for any side effects (tooth hypersensitivity or soft tissue complications) was also performed at each check-up. The following results were obtained. 1. Both the experimental and control groups displayed a noticeable change in shade (${\Delta}E$) of over 2. No significant differences were found between the two groups (p > 0.05), implying that the two agents have a similar whitening effect.2. The whitening effect was mainly due to changes in a and b values rather than in L value (brightness). The experimental group showed a significantly higher change in b value, thus yellow shade, than the control (p < 0.05). 3. None of the participants complained of tooth hypersensitivity or soft tissue complications, confirming the safety of both whitening agents.