• Title/Summary/Keyword: 폭 크기

Search Result 1,454, Processing Time 0.031 seconds

The perceptual span of Junior-high school students in Korean reading (우리글 읽기에서 중학생들의 지각폭 연구)

  • Choi, Soyoung;Koh, Sungryong
    • Korean Journal of Cognitive Science
    • /
    • v.25 no.3
    • /
    • pp.189-210
    • /
    • 2014
  • The present study investigated the perceptual span(or the span of effective vision) of junior-high school students during reading Korean, using the material and the moving-window display change technique used in Choi & Koh(2009). The 8 different window sizes were used in the experiment. They were 3, 5, 7, 9, 11, 13, 15 characters in size and the whole line. Reading rate, number of fixation, saccadic distance, fixation duration were compared between each window-size condition and the whole line condition. Considering the pattern of eye-movement measures above, the size of the perceptual span of junior-high school students in Korean reading may be estimated to be 9 characters, that is 4 characters to the right and 1 characters to the left of the fixation.

Characteristics of step-pool structure in the mountain streams around Mt. Jiri (지리산 주변 산지하천의 step-pool 구조 특성)

  • Kim, Ki Heunga;Jung, Hea Reyn
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.4
    • /
    • pp.313-322
    • /
    • 2018
  • The height of the steps was almost the same as the grain size of bed materials and increased with channel slope. The step widths and step wavelengths are almost the same size, and the step wavelength was decreased when the channel slope was increased. It was analyzed that there was a clear correlation between channel width and step width, and the step width increases with channel width. In addition, the step wavelength was scaled by channel width, and the step height is governed by the grain size of the rock forming the step, so that the profile structure of the step-pool was changed according to the channel slope. the scale of the pool was found to be highly correlated with the channel width, grain size, and slope gradient. Therefore, the characteristics of step-pool structure in mountain streams were influenced by various factors, but it can be explained as the grain size, channel width and channel slope.

Relation of Grain Size with Magnetic Domain Wall for Tertiary Recrystallized 3% Si-Fe Strip (3차 재결정에 의한 극박 방향성 규소강판의 결정립 크기와 자벽수와의 관계)

  • ;K. I. Arai
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.3
    • /
    • pp.165-169
    • /
    • 1996
  • The relationship between grain size and number of magnetic domain walls for tertiary recrystallized ultra thin 3 % Si-Fe strips was investigated. It was found that the strips with different grain size can be produced by controlling the inserting speed of sample in annealing furnace. Though grain size of the stirip became smaller than 1mm, $B_{8}$ of high value above 1.95T was obtained. But $H_{c}$ increased with decaying the grain size. The magnetic domains and losses of the ultra thin grain oriented silicon steel with smaller grian size were observed. The eddy current losses of the strips were decreased with decreasing the grain size in high frequency range because strips with smaller grain have narrower magnetic domain wall spacings. But Hysteresis losses of the strips with smaller grain have high value in low frequency range. Therefore the iron loss of ultra thin grain oriented silicon steel could be controlled by the grain size. It was clarified that the minumum tatal loses depended on the exciting frequency and grain size.

  • PDF

Analysis on the Effect of Field Width in the Delineation of Planning Target Volume for TomoTherapy (토모테라피에서 계획용표적체적 설정 시 필드 폭 영향 분석)

  • Song, Ju-Young;Nah, Byung-Sik;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Yoon, Mee-Sun;Jung, Jae-Uk
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.323-331
    • /
    • 2010
  • The Hi-Art system for TomoTherapy allows only three (1.0 cm, 2.5 cm, 5.0 cm) field widths and this can produce different dose distribution around the end of PTV (Planning target volume) in the direction of jaw movement. In this study, we investigated the effect of field width on the dose difference around the PTV using DQA (Delivery quality assurance) phantom and real clinical patient cases. In the analysis with DQA phantom, the calculated dose and irradiated films showed that the more dose was widely spreaded out in the end region of PTV as increase of field width. The 2.5 cm field width showed a 1.6 cm wider dose profile and the 5.0 cm field width showed a 4.2 cm wider dose profile compared with the 1.0 cm field width in the region of 50% of maximum dose. The analysis with four patient cases also showed the similar results with the DQA phantom which means that more dose was irradiated around the superior and inferior end of PTV as an increase of field width. The 5.0 cm field width produced the remarkable high dose distribution around the end region of PTV and we could evaluate the effect quantitatively with the calculation of DVH (Dose volume histogram) of the virtual PTVs which were delineated around the end of PTV in the direction of jaw variation. From these results, we could verify that the margin for PTV in the direction of table movement should be reduced compared with the conventional margin for PTV when the large field such as 5.0 cm was used in TomoTherapy.

Size Effects on the Compressive Strength of Composite Plates with an Open Hole (홀을 갖는 복합재 적층판의 압축강도에 대한 크기 효과에 관한 연구)

  • ;;;C. Soutis
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.5 no.1
    • /
    • pp.42-48
    • /
    • 2001
  • Over two decades, many researchers have performed studies on strength size effects in composite laminates under tensile and flexural loads. It is well known that there is a tendency for the strength of fibre-reinforced composites to decrease with increasing specimen size. Under compressive load, however, little work has been done on the effect of specimen size to failure strength. This is due to the fact that compressive testing of composite is very difficult. In this paper, the effect of the test specimen size on the compressive strength of composites containing open hole was considered using T300/924C, $>[45/-45/0/90]_{3S}$. For sizing test specimens, the in-plane scaling method is used i.e., the change of two- dimensional specimen area in specimen width and gauge length. The results clearly show that there is a hole size effect in the finite width plates. In addition, the specimens which have the same a/W(hole diameter/specimen width) exhibit a tendency of size effect. In contrast, test results of the unnotched specimens did not show a clear strength size effect.

  • PDF

Detection of the Defect on the Metal Surface Using the Modulated Microwave (변조 고주파에 의한 금속표면 결함 검출)

  • Joo, G.T.;Jung, S.H.;Song, K.Y.;Kim, J.O.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.3
    • /
    • pp.173-179
    • /
    • 1999
  • The defects on the metal surface. such as the ended circular pressed hole. the penetrated circular drilled hole, and the linear hollow lanes have been investigated by means of the microwave. In this experiment, frequency was set at 9.2GHz with 3kHz modulation, and the methods of reflection, transmission, fixed carrier frequency, and mod-demodulated technique have been used for investigating defects. The magnitudes of the microwave signals have been changed at the ended circular pressed hole and the penetrated circular drilled hole. The defect sizes that were estimated from the reflected microwave signals had the dimensions enlarged by twice the original size of the penetrated circular drilled hole and 2.5 times the original size of the ended circular pressed hole. The magnitudes of the reflected microwave signals from the linear hollow lane have increased with expansion of the width of the notch. In the linear hollow lane with the depth of 2.4mm, the reflected microwave signals versus the defect widths had a maximum value at the defect width of 50mm, and in the linear hollow lanes with the depths of 1.2mm and 0.45mm, the reflected microwave signals versus the defects widths had the maximum values each at the defect depths of 55mm.

  • PDF

Effect of Micro-Cracks on Chloride Ions Penetration of Concrete II: Examination of Critical Crack Width (미세균열이 콘크리트의 염소이온 침투에 미치는영향 II: 임계 균열폭의 고찰)

  • Yoon, In-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.6
    • /
    • pp.707-715
    • /
    • 2007
  • The vulnerability of concrete to its environment is significantly dependent on the fact that concrete is a porous material. For well-consolidated and well-cured concrete, its service life is a very long and an entrance of aggressive substance might be only pores. However, for cracked concrete, cracks should be preferential channel for the penetration of aggressive substance such as chloride ions. The effect of crack on chloride penetration depends on its size for example, crack width and crack depth. The purpose of this study is examining the effect of crack width and crack depth on chloride penetration. In order to visualize chloride penetration via cracks, RCM (rapid chloride migration) testing is accomplished. Crack width is examined using an optical microscope and CMOD value is used to estimate average crack width. From the examination on the trend of chloride diffusion coefficients of concrete specimens with various crack widths, a critical crack width and a critical crack depth are found out.

대면적 방전셀을 적용한 AC PDP의 방전 특성 연구

  • Yun, Min-Su;Jeong, Hui-Un;Lee, Tae-Ho;Hwang, Gi-Ung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.449-449
    • /
    • 2012
  • 플라즈마 디스플레이 패널(PDP)은 가격 경쟁력이 뛰어나고 빠른 반응 속도를 기반으로 한 생생한 화질이 구현 가능한 장점에 힘입어 대형 평판 디스플레이 시장에서 주도적인 위치를 점하여 왔다. 이러한 특징을 갖고 있는 PDP는 최근 성장세를 보이고 있는 PID (Public Information Display) 시장에서도 그 효력을 발휘할 것으로 보인다. 따라서 기존의 HD급이나 Full HD급 미소 방전셀이 아닌 대면적 방전셀을 적용한 PDP 의 방전 특성에 대한 연구가 중요할 것으로 생각된다. 본 논문에서는 ITO 전극 간격 및 전극 폭, 격벽의 폭 및 높이 등 PDP 의 방전 특성에 영향을 미치는 요소들의 수치를 변화시켜 가며 대면적 방전셀을 적용한 PDP의 기본적인 방전 특성을 살펴보고자 하였다. 이를 바탕으로 대면적 방전셀 PDP에서 고효율을 달성하기 위해 필요한 인자의 설계 방향을 제시해보고자 하였다. 본 논문에서 연구된 PDP는 0.862.58 mm의 셀의 크기를 갖도록 설계하였다. 앞서 제시한 바와 같이 구조 변수의 최적화를 위하여 ITO 전극 간격은 80~1, 전극의 폭은 250~750로 다양하게 주어 상판을 제작하였고 격벽의 폭은 100~200, 높이는 150~300까지 다양한 크기를 가지는 하판을 제작하여 박막 증착, 합착, 가열 배기 등의 과정을 통하여 최종적으로 2인치 크기의 테스트 패널을 제작하여 각 패널별 전압 변화, 휘도, 효율 특성 등이 분석되었다. 실험 결과 격벽 폭 150, 높이는 300일 때 negative glow 방전이 안정적으로 형성될 수 있었음을 확인하였고 최적화된 격벽 수치를 기반으로 다양한 ITO 전극 간격 및 전극 폭을 적용한 패널의 방전 특성을 분석할 수 있었다. 이러한 일련의 실험 결과들을 기반으로 향후 대면적 방전셀의 방전 전압을 낮추고 발광 효율을 개선하는데에 있어서 3전극의 면방전 구조를 가지는 PDP 의 셀을 설계하는데에 있어서 올바른 방향을 마련할 수 있을 것이라 생각된다.

  • PDF

A Research of the Width of Passage in the Namyangju Elementary School Classroom (남양주 초등학교 일반교실의 통로 폭에 관한 조사 연구)

  • Yoon, Hee-Cheol
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.19 no.4
    • /
    • pp.60-69
    • /
    • 2020
  • This research is a preliminary study to find out the module of 20 students in a classroom. This research investigated the widths of passages in the 30 classrooms of 5 elementary schools in Namyangju City, Korea. The conclusions were as follows: First, the area of unit for 1 student was 650 (W) × 950 (D). Second, the desk placements for most classrooms were one-way types (87%), and group-study types constituted 13%. Third, the width between the blackboard and the very front desk was 2.17 m. The width of passage between the very back seat and the backside lockers was 1.32 m. The width of passage between the sidewall and the nearby desk was 0.8 m. The width of passage between the window and the nearby desk was 0.8 m. The average widths of 2 vertical passages between the desks were respectively 0.67 m and 0.68 m. Fourth, the area of the teacher was 2.1-2.25 m × 2.16 m = 4.5-4.8 ㎡.

Magnetic Sensitivity Depending on Width of IrMn Spin Valve Film Device (IrMn 스핀밸브 박막소자의 폭 크기에 의존하는 자장감응도)

  • Choi, Jong-Gu;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.2
    • /
    • pp.41-44
    • /
    • 2010
  • The Cu thickness dependence of magnetic sensitivity for the NiFe/Cu/NiFe/IrMn spin valve multilayer was investigated. The magnetic properties measured by minor MR curves for the Ta(5 nm)/NiFe(8 nm)/Cu(3.5 nm)/NiFe(4 nm)/IrMn(8 nm)/Ta(2.5 nm) multilayer is MR = 1.46 %, MS = 2.0 %/Oe, $H_c\;=\;2.6\;Oe$, and $H_{int}\;=\;0.1\;Oe$. The magnetic sensitivities of GMR-SV devices with ten different widths and a same length of $4.45\;{\mu}m$ by fabricated by photo lithography decreased from 0.3 %/Oe to 0.06%/Oe as from a width of $10\;{\mu}m$ to $1\;{\mu}m$.