• Title/Summary/Keyword: 포집기

Search Result 271, Processing Time 0.022 seconds

Seasonal Variations of Settling Particles and Metal Fluxes at a Nearshore Site of Marian Cove, King George Island, Antarctica (남극 킹조지섬 마리안소만에서 침강 입자와 금속 플럭스의 계절 변화)

  • Shim, Jeong-Hee;Kang, Young-Chul;Han, Myung-Woo;Kim, Dong-Seon;Chung, Ho-Sung;Lee, Sang-Hoon
    • Ocean and Polar Research
    • /
    • v.24 no.2
    • /
    • pp.123-134
    • /
    • 2002
  • Seasonal variations of settling particles and metal fluxes were monitored at a nearshore site of Marian Cove, King Geroge Island, Antarctica from 28th February 1998 to 22nd January 2000. Near-bottom sediment traps were deployed at 30m water depth of the cove, and sampling bottles were recovered every month by SCUBA divers. Total particulate flux and metal concentrations were determined from the samples. Total particulate flux showed a distinct seasonality, high in austral summer and low in austral winter: the highest flux $(21.97g\;m^{-2}d^{-1})$ was found in February of 1999, and the lowest $(2.47g\;m^{-2}d^{-1})$ in September of 1998, when sea surface was frozen completely. Lithogenic particle flux accounted for 90% of the total flux, and showed a significantly negative correlation with the thickness of snow accumulation around the study site. It was suggested that the most of the lithogenic particles trapped in the bottles was transported by melt water stream from the surrounding land. Fluxes of Al, Fe, Ti, Mn, Zn, Cii, Co, Ni, Cr, Cd, and Pb showed similar seasonal variations with the total flux, and their averaged fluxes were 34000, 9000,960, 180, 13.8, 17.6, 3.0,2.1, 5.4, 0.02, and $1.5nmol\;m^{-2}d^{-1}$ respectively. Among the metals, Cu and Cd showed the most noticeable seasonal patterns. The Cd flux correlated positively with the fluxes of biogenic components while the Cu flux correlated with both the lithogenic and biogenic particle fluxes. The Cu flux peak in the late summer is likely related to a substantial amount of inflow of ice melt water laden with Cu-enriched lithogenic particles. On the other hands, the Cd flux peak in the early spring may be associated with the unusually early occurred phytoplankton bloom.

Isolation and Characterization of Airborne Bacteria and Fungi in Indoor Environment of Elementary Schools (초등학교 실내환경에서 공기 중 세균과 진균의 분리 및 특성)

  • Kim, Na-Yeong;Kim, Young-Ran;Kim, Min-Kyu;Cho, Du-Wan;Kim, Jong-Seol
    • Korean Journal of Microbiology
    • /
    • v.43 no.3
    • /
    • pp.193-200
    • /
    • 2007
  • Indoor airborne bacterial and fungal concentrations were examined at classrooms and corridors of 3 elementary schools in Ulsan. Airborne microorganisms were collected with an impaction-type air sampler using plate count agar and dichloran rose bengal chloramphenicol agar. During the semester, concentrations of bacteria ranged $168{\sim}3,887 MPN/m^3$ at classrooms and $168{\sim}6,339 MPN/m^3$ at corridors, while those of fungi ranged $34{\sim}389 MPN/m^3$ at classrooms and $91{\sim}507 MPN/m^3$ at corridors. The bacterial concentrations showed larger variations between situations and schools compared to those of fungi. When airborne bacteria were isolated and identified, 84% were observed as Gram-positive, and Micrococcus spp. was the most abundant group with 61% of tested isolates, followed by genus Staphylococcus with 10%. The Micrococcus spp. isolates, of which 75% were identified as M. luteus, appeared to be from human origins. The protective pigments and substantial cell wall of Micrococcus may provide selective advantage for their survival in the air. We also isolated and identified 15 genera of filamentous fungi. The most common culturable fungi were Cladosporium, Aspergillus and Penicillium, and these 3 genera were 69% of fungal isolates. Genus Stachybotrys, of which S. chartarum is a well known producer of many potent mycotoxins, was also detected from one of the schools. further systematic studies are necessary with an emphasis on species identification and mycotoxin production of isolated fungal genera, including Aspergillus, Penicillium, and Stachybotrys.

Kinetic Study on Preparation of Iron Fine Powders by Hydrogen Reduction of Ferous Chloride Vapor (염화물의 기상환원반응에 의한 미립질 철분말의 생성속도에 관한 연구)

  • Lee, Hwa-Yeong;Kim, Seong-Gyu
    • Korean Journal of Materials Research
    • /
    • v.10 no.6
    • /
    • pp.385-391
    • /
    • 2000
  • A kinetic study on the preparation of iron powder by hydrogen reduction of ferrous chloride vapor has been carried out both experimentally and theoretically. For the preparation of iron powder, ferrous chloride was vaporized and transported to a reaction zone by Ar gas used as carrier. Ferrous chloride vapor and hydrogen were mixed and subject to a reduction reaction at high temperature to produce iron powder and HCI gas. Iron powder was collected with organic solvent at the end of reaction zone and HCI gas was also absorbed in a caustic soda solution to determine the conversion ratio of ferrous chloride. For the development of rate equations, a 1st-order reaction and equilibration of ferrous chloride vapor with Ar gas were assumed. According to the results, the rate constant, k could be expressed as $k=7,879exp(-53,840/RT)\textrm{dm}^3/mole.sec$ and the activation energy was found to be 53.84kJ/mole. From TEM observation, the particle size distribution of iron powder produced was found to be in the range of $0.1~1.0{\mu\textrm{m}}$ which was not significantly influenced by reaction temperature or gas flow rates.

  • PDF

A Study on the Quantitative Recovery of Dissolved Inorganic Carbonates in Ground Water for Radiocarbon Measurement (방사성탄소 측정을 위한 지하수 중에 용존된 무기탄소 화합물의 정량적 회수 연구)

  • Chun, Sang-Ki;Woo, Hyung-Joo;Cho, Soo-Young;Kim, Nak-Bae;Lee, Jong-Dae
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.284-289
    • /
    • 1999
  • Dissolved inorganic carbonates in ground water were quantitatively recovered by using gas evolution method. Gas evolution method was found to be less time-consuming, less susceptible to the contamination fromatmospheric $CO_2$ and little affected by the sulfate ions in comparison to the direct precipitation method. Extraction efficiency of nearly 99% could be achieved by gas evolution method in two hours using recirculated gas at a sweeping rate of 4 liter per minute. Samples for carbon isotope fractionation study were collected in three fractions with collection times. The evolution time for the first fraction was one hours, and then second and third fractions were collected at intervals of 30 minutes, respectively. A small portion of each fraction was analyzed to evaluate ${\delta}^{13}C$ values, which were measured to be -7.9‰, -3.0‰ and +0,4‰ for the each fraction. The result clearly indicated that gas evolution method generates isotopically lighter carbon at the beginning of the purging process and heavier isotopes at the end. However, this isotope fractionation effect could be neglected by the almost complete recovery of carbonates.

  • PDF

The Sampling Efficiencies of Volatile Organic Compounds(VOCs) to the Diffusive Monitor with Activated Carbon Fiber (활성탄섬유를 이용한 확산포집기의 공기 중 유기용제 포집효율에 관한 연구)

  • Byeon, Sang-Hoon;Park, Cheon-Jae;Oh, Se-Min;Lee, Chang-Ha
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.2
    • /
    • pp.187-201
    • /
    • 1996
  • This study was to evaluate the efficiency of diffusive monitor using activated carbon fiber(ACF, KF-1500) in measuring airborne organic solvents. The following characteristics were identified and studied as critical to the performance of diffusive monitor; recovery, sampling rate, face velocity, reverse diffusion and storage stability. For the evaluation of the performance of this monitor, MIBK, PCE, toluene were used as organic solvents. In the sampling rate experiments, eight kinds of solvents (n-hexane, MEK, DIBK, MCF, TCE, CB, xylene, cumene) as well as the above solvents were used. The results were as follows: 1. The desorption efficiencies(DE's) of ACF diffusive monitor ranged from 83 % to 101 %. In contrast, those of coconut shell charcoal ranged from 78 % to 102 %. Especially, the DE's of ACF for the polar solvents such as MEK were superior to those of charcoal. 2. Experimental sampling rates on ACF were average 42ml/min(37-46ml/min) for 11 organic solvents at $24{\pm}2^{\circ}C$, $50{\pm}5%RH$. However ideal sampling rates(DA/L) were 33 % higher than experimental sampling rates. 3. The initial response(15~16 min) of the testing monitor was 2 times higher than the actual concentration determined by the reference methods at $24{\pm}2^{\circ}C$, $8{\pm}5%RH$ and $80{\pm}5%RH$. Within 1 hours, the curve reached a linear horizontal line at low humidity condition. But sampling efficiencies decreased with respect to time at high humidity condition. And sampling efficiencies were higher at high humidity condition than low humidity condition for MIBK. 4. At very low velocity (less than 0.02 m/sec), the concentration of ACF diffusive monitor were poorly estimated. But ACF diffusive monitor were not affected at higher velocity(0.2 m/sec-0.6 m/sec). 5. There was no significant reverse diffusion when the ACF monitors were exposed to clean air for 2 hours after being exposed for 2 hours at the level of 1 TLV. 6. There was no significant sample loss during 3 weeks of storage at room temperature and 5 weeks of storage at refrigeration.

  • PDF

Dust Removal Efficiency and Operation Characteristics of Metal Filters for Coal Gasification Fines and Standard Dust Sample (금속필터를 사용한 석탄가스화 분진 및 표준 분진의 집진 효율과 운전특성)

  • Yun, Yongseung;Chung, Seok Woo;Lee, Seung Jong
    • Korean Chemical Engineering Research
    • /
    • v.57 no.4
    • /
    • pp.461-468
    • /
    • 2019
  • Demand for improving dust removal efficiency in coal power plants and the dust removal requirement to the level of capturing fine particulate matter and ultrafine particles have been increasing. While bag filter and electrostatic precipitator (ESP) are typically used for dust removal in the processes operating at atmospheric pressure, metal filters or ceramic filters are employed for dust which is produced at high temperature/pressure system as in coal gasification. For dust removal at the high temperature/pressure conditions, two metal filters of five compressed/sintered layers were manufactured and applied to analyze the dust removal characteristics. Manufactured metal filters exhibited more than 99% dust removal efficiency on coal gasification fine particulates in mass basis. To evaluate the fine particulate removal efficiency of less than $2.5{\mu}m$, JIS standard fine sample was used and confirmed the removal efficiencies of 97% and 70~82% on the fine particulates of $1{\sim}2.5{\mu}m$ size range. For the size range of less than $1{\mu}m$, dust removal efficiency of manufactured metal filters significantly degraded with smaller particle size. Improving methods are proposed to overcome the limitations in applying to fine dust of less than $1{\mu}m$.

A Basic Study on the Generation of Tire & Road Wear Particles by Differences in Tire Wear Performance (타이어 마모성능 차이에 의한 타이어 마모입자 생성에 관한 기초 연구)

  • Kang, Tae-Woo;Kim, Hyeok-Jung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.561-568
    • /
    • 2021
  • In this study, in order to observe the change in the amount of Tire and Road Wear Particles and the ratio of tire components in it according to the tire wear resistance performance, carried out the evaluation by varying the vulcanization reaction design of the tire tread rubber. In addition, in order to improve the reliability of the evaluation of Tire and Road Wear Particles, the evaluation was performed indoor laboratory test equipment that simulates the condition on real driving to exclude various environmental influences including minerals, driver's habits, road surface, weather, tire structure and pattern designs. After the evaluation in closed space, it is estimated that the amount of collected Tire and Road Wear Particles is 84% compared to 100% of the tire and road wear loss weight, of which 96.4~97.7% was around the road and 2.3~3.6% was in the air. As a result of analy sis of the collected Tire and Road Wear particles, the tire component existed 63~75% in the Tire and Road Wear Particles depending on the wear resistance performance of the tire.

Optimization for I-129 analytical method of radioactive waste sample using a high-temperature combustion tube furnace (고온연소로를 이용한 방사성 폐기물 내 I-129 정량 분석법 최적화 연구)

  • Chae-yeon, Lee;Jong-Myoung, Lim;Hyuncheol, Kim;Ji-Young, Park;Jin-Hong, Lee
    • Analytical Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.256-266
    • /
    • 2022
  • It is important to determine the concentration of long-lived radionuclides (e.g., 129I) in nuclear waste to ensure safety when handling it. To analyze nuclides in a solid sample (e.g., concrete and soil), it is essential to effectively separate and purify the nuclides of interest in the sample. This study reports the comprehensive efforts made to validate the analytical procedure for 129I detection in solid samples, using a high-temperature combustion furnace. 129I volatilized from the sample collected in 0.01 M HNO3 solution with a reducing agent (e.g., NaHSO3) and was rapidly measured by ICP-MS. Analytical conditions, such as pyrolysis temperature and types of mobile phase gas, catalyst, and trapping solution, were optimized to obtain a high recovery rate of spiked 129I. Finally, the optimized method was applied for the simultaneous analysis of other volatile radionuclides, such as 3H and 14C. The performance test results for the optimized method confirmed that the LSC (for 3H and 14C) and ICP-MS (for 129I) measurements, with the separation of volatile nuclides using a high-temperature combustion furnace, were reliable.

Potential Exposure of Nanoparticles from Laboratory to Office (실험실에서 사무실로의 나노입자의 잠재적 노출)

  • Shin, Hyeokjin;Kim, Younghun
    • Clean Technology
    • /
    • v.28 no.2
    • /
    • pp.123-130
    • /
    • 2022
  • Nanoparticles are used in various fields such as chemistry, medicine, the environment, and information and communication. With the increasing use of engineered nanomaterials, exposure to nanoparticles is expected to increase in the workplace and the environmental media. However, while nanotechnology industries are expanding, research on the exposure assessment of nanomaterials to humans and the environment is only at a beginning stage. Especially, if nanoparticles with a size of 100 nm or less that are contained in nano-products are released unintentionally, they may pose potential risks to the human body through breathing or skin exposure. Therefore, in this work, the possibility of potential exposure of nanoparticles moving from the laboratory to the office was confirmed, and nanoparticle safety guidelines are proposed. A nano-collector was used to detect nanoparticles in the atmosphere, and through use of a scanning mobility particle sizer it was found that nanoparticle concentrations in the laboratory and the office tended to be similar. On the assumption that nanoparticles attached to a lab-coat move out of the laboratory, a lab-coat to which nanocarbon black was attached was shaken and the concentration of the remaining particles on the lab-coat determined. The results confirmed that sufficient amounts of nanoparticles attached to the lab-coat could move from the laboratory to the office along the path of a researcher; thus, safety guidelines for the handling of lab-coat nanoparticles are required.

Emission Rates of Biogenic Volatile Organic Compounds (BVOCs) from Various Tree Species in Korea (I) (국내 수종별 BVOCs 방출량 (1))

  • Chang, Hanna;Son, Jounga;Je, Sun Mi;Oh, Chang-Young;Cho, Minseok;Kim, Juwan;Kim, Jaehyeon;Choi, Won-Sil;Lee, Young-Kyu
    • Journal of Korean Society of Forest Science
    • /
    • v.110 no.4
    • /
    • pp.543-553
    • /
    • 2021
  • This research focused on the investigation of isoprene and terpene emissions from 30 major urban tree species. We conducted sampling using a specific dynamic enclosure system between August and September 2020. Seedlings less than three years old were enclosed in a chamber consisting of a 400 L transparent Tedlar bag. The air-flows from the chamber's outlet were sampled using Tenax-filled sorbent tubes in the presence of standard conditions (temperature: 30℃, PAR: 1,000 μmol/m2/sec). A thermal desorption GC/MS system was used to analyze 38 BVOC compounds (isoprene, monoterpene, sesquiterpene, oxygenated monoterpene, and sesquiterpene). Isoprene emitters included Phyllostachys bambusoides, Quercus serrata, Daphniphyllum macropodum, and Buxus Koreana. Monoterpene emitters included Pinus rigida, Acer pictum subsp. mono, Larix kaempfer, Magnolia denudata, Metasequoia glyptostroboides, Pinus koraiensis, Pinus densiflora, and Abies holophylla. The monoterpene emission profiles were dominated by α-pinene, myrcene, limonene, β-pinen, and sabinene, while caryophyllene and farnesene were the prominent sesquiterpenes. Predominant oxygenated monoterpene compounds were also discovered as pulegone, borneol, menthol, eucalyptol, and nerol, while caryophyllene oxide were the prominent oxygenated sesquiterpenes. Sesquiterpenes and oxygenated sesquiterpenes had relatively lower contributions for all species.