• Title/Summary/Keyword: 폐밀도

Search Result 115, Processing Time 0.024 seconds

Evaluation of Total Lung Volume and Density using Multi-Detector Computed Tomography in Normal Dogs (정상견에서 다중채널 컴퓨터단층촬영술을 통한 폐용적과 밀도의 평가)

  • Choi, Ho-Jung;Lee, Ki-Ja;Choi, Soo-Young;Lee, Jung-Woo;Han, Woo-Sok;Lee, In;Kwon, Young-Hang;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.28 no.5
    • /
    • pp.510-515
    • /
    • 2011
  • This study was performed to quantitatively assess the normal lung volume and density according to the position by multi-detector computed tomography (MDCT) in dogs. Helical CT of the thorax was performed on 4 different positions with dorsal, left lateral, right lateral and ventral recumbency in 6 Pekingese and 6 Maltese dogs. During CT scanning, dogs were kept hyperventilated. Through the 3-dimensional reconstruction of CT images, the lung parameters were measured as the volume and density of the left, right including accessory lobe, and total lung. 3D images represented the different lung shape between Pekingese and Maltese dogs. Their difference of total lung volume and total lung density was not significant on the each position in both breeds. Right lung volume was significantly higher than left. The difference of left and right volume was $66.91{\pm}25.1$ ml. Linear relationship was shown between body weight and lung volume of ventral recumbency position. The dependent lung had higher density and lower volume than nondependent lung in both breed dogs. The volume of nondependent lung was not changed compared with the volume on ventral or dorsal recumbency. The total lung volume measured with MDCT is correlated with the lung density, and the lung density is useful to predict the normal total lung volume.

Quantitative CT Evaluation for Lung Volume and Density in Dogs (개에서 정량적 컴퓨터단층촬영을 이용한 폐용적과 폐밀도의 평가)

  • Choi, Soo-Young;Lee, In;Jeong, Woo-Chang;Heng, Hock Gan;Lee, Young-Won;Choi, Ho-Jung
    • Journal of Veterinary Clinics
    • /
    • v.31 no.5
    • /
    • pp.376-381
    • /
    • 2014
  • In this study, we analyzed the computed tomography (CT) measurements of lung volume and density in dogs with relation to body weight, age, sex, and breed. The multi-detector CT examination of the thorax was performed on dogs without respiratory or cardiovascular diseases. Three-dimensional reconstruction of CT images facilitated measurement of lung volume and density. There was a statistical significant correlation between body weight and lung volume (p < 0.0001). Lung density significantly decreased with an increase in body weight (p = 0.0078). However, no correlation was seen between these lung parameters and either sex or age of the dogs. In conclusion, this study shows that body weight is an important factor to consider when interpreting total lung volume and density values measured by quantitative CT. We highlight the need for further study using quantitative CT in identifying the potential effects of sex, age, and disease status on these parameters.

Assessment of Computed Tomographic Lung Density in Beagle and Shihtzu Dogs : Influence of Position and Positive End Expiratory Pressure (비글과 시츄견에서 호기말 양압에 따른 전산화 단층촬영상의 폐밀도의 평가)

  • Kim, Tae-Hun;Chang, Jin-Hwa;Yun, Seok-Ju;Yoon, Jung-Hee;Chang, Dong-Woo
    • Journal of Veterinary Clinics
    • /
    • v.27 no.3
    • /
    • pp.273-283
    • /
    • 2010
  • The objective of this study was to measure densities in various areas of the normal canine lung with computed tomography (CT) depending on influences of gravity and the degree of lung inflation and to determine optimal positions and positive end expiratory pressure of canine lung for CT scanning. In each eight normal Beagle and Shihtzu dogs, a respiratory breathhold maneuver without spontaenous breathing at different positive end expiratory pressure (PEEP) of 0 mmHg, 10 mmHg and 20 mmHg was applied with the position of right and left lateral recumbency, sternal recumbency, and dorsal recumbency and spiral-CT scans of the total lung were acquired. Slices were selected at three levels through the apex, middle and basal lung at the aortic arch, carina and just above the diaphragm and lung density was measured in the dorsal, ventral, and lateral portions of the peripheral lung field. Lung density in dependent areas was higher than in nondependent areas (p < 0.05) regardless of species, positions, anatomic locations at the PEEP of 0 mmHg and 10 mmHg. However, no significant difference of lung density was found at PEEP of 20 mmHg in both species except the dorsal recumbency in Shihtzu dogs. This density gradient in the dependent areas is strongly influenced by PEEP (p < 0.05). In the four positions on the CT gantry, the lung density at the dependent and nondependent location of the lung was greater at the aortic arch than at the base (p < 0.05). Lung density decreased on identical location according to increase of PEEP (p < 0.05). There was no significant difference between right and left lung density at sternal and dorsal recumbency and no significant difference of the dorsal, ventral, and lateral portions of lung density at the right and left recumbency under identical pressure. It is implied that during chest CT scan with 20 mmHg of positive end expiratory pressure with right or left lateral recumbency, canine lung density do not influenced by gravity or anatomic location.

A Study on Properties of Waste Wood-Plastic Composite Panels (폐목재-플라스틱을 이용한 복합패널의 특성 연구)

  • Mun, Kyoung-Ju;Choi, Nak-woon;Choi, San-Ho
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.4
    • /
    • pp.85-94
    • /
    • 2004
  • Waste wood-plastic composite panels are made on different hot press molding conditions, and tested for apparent density, water absorption, expansion in thickness and flexural strength. From the test results, regardless of molding temperature and molding time, the apparent density of the composite panels is increased with an increase in the molding pressure, while their water absorption is decreased with an increase in the molding pressure. The flexural strength of the composite panels is markedly increased with increasing molding pressure, molding temperature and molding time, and tends to become nearly constant at a molding temperature of $120^{\circ}C$ and a molding time of 15min.

  • PDF

Basic Properties of Waste Wood-Plastic Composite Panels by Hot Press Molding Method (열압 성형법에 의한 폐목재-플라스틱 복합패널의 기초적 성질)

  • Choi, Nak-Woon;Mun, Kyoung-Ju;Choi, San-Ho
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.4
    • /
    • pp.95-104
    • /
    • 2004
  • A styrene solution of waste expanded polystyrene with a crosslinking agent and an initiator was used as a binder for waste wood-plastic composite panels. The waste wood-plastic composite panels are prepared with various binder contents and filler-binder ratios by using a hot press molding method. The apparent density of the composite panels is increased with increasing binder content and filler-binder ratio, while their water absorption and expansion in thickness are decreased with increasing binder content and filler-binder ratio. The maximum flexural strength and wet flexural strength of the composite panels are obtained at a binder content of 35% and a filler-binder ratio of 0.8. Decreases in the flexural strengths of the composite panels due to water immersion at 20 and $100^{\circ}C$ are hardly recognized at binder contents of 30% or more.

  • PDF

A Study on Computer-Aided Diagnosis System for Interstitial Lung Disease in Chest Radiograph (흉부 영상에서 간질성 폐질환 검출을 위한 컴퓨터지원진단 시스템 연구)

  • 김진철;송종태;이우주;이배호
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04c
    • /
    • pp.316-318
    • /
    • 2003
  • 간질성 폐질환(Interstitial Lung Disease) 컴퓨터지원진단(Computer-Aided Diagnosis: CAD)시스템은 방사선의사들이 흉부 X-ray영상에서 석회화와 섬유화를 탐지하고자 적용하였다. 진단 중에 발생할 수 있는 오진율을 줄이고 간질성 폐질환이 존재하는 폐야에서 이상유무를 판단하여 검출을 표시하도록 하였다. 본 논문에서는 디지털 흉부영상에서의 간질성 폐질환을 검출하기 위해 폐 텍스처(texture)의 물리적 척도를 측정하기 위한 방법을 제안한다. 2차원의 푸리에 변환으로부터 얻어지는 파워스펙트럼(power spectrum) 분석에 기반을 두는 방법으로 각각의 ROI(Region Of Interest)에서 구한 평균제곱자승오차(Root Mean Sguare: RMS)와 파워스펙트럼의 첫 번갠 모멘트(Moment)는 폐 텍스처의 밀도변동의 크기(magnitude)와 섬세함(fineness)을 나타낸다. 실험결과 다양한 간질성폐질환을 가진 비정상 폐 텍스처의 RMS와 첫 번째 모멘트와는 차이가 있었다. 디지텔 흉부영상으로부터 계산되어진 정량화된 텍스처의 척도는 방사선의사의 간질성 폐 질환을 진단함에 효율적인 질환 탐지를 가능하게 하였으며 진단율을 향상시킬 수 있었다.

  • PDF

Bronchus image segmentation by Threshold transform (임계치를 이용한 폐 기관지 영상 분할)

  • Tak, Jeong-nam;Kim, Hye-suk;Lee, Guee-sang;Kim, Soo-hyung;Hong, Sung-hoon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2004.05a
    • /
    • pp.785-788
    • /
    • 2004
  • 폐 기관지는 외부의 공기를 폐까지 전달해주는 역할을 하고 있다. 이는 병리학적, 해부학적으로 중요한 역할을 하고 있으며, 의사들에게는 기관지의 상태를 시각적으로 쉽게 판독을 할 수 있다면 폐에서 발생하는 기관지염(bronchitis), 기관지 확장증(bronchiectasis), 폐기종(pulmonary emphysema), 결핵(tuberculosis), 기흉(pneumothorax)등 여러 가지 병명을 쉽게 판독이 가능하다. 지금까지 폐 기관지에 대한 연구가 지속적으로 진행 되었으며, 2D CT 영상에서의 주변의 밀도차가 유사한 폐실 질에서의 폐기관지를 추출해 내는 것은 어려움을 Gray-scale Reconstruction과 임계치를 이용하여 추출하였다. 이는 3D 구성을 위한 전 단계로 인체 내부의 장기를 가상의 영상을 실제와 가까운 영상으로 구현하는데 쓰인다.

  • PDF

Dose Calculation of Heterogeneous Lung Tissue on 6MV X-ray Therapy (6MV X-선에 의한 폐조직의 심부선량변화와 임상응용)

  • 이경자;장승희;추성실
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.247-257
    • /
    • 1998
  • For effective radiotherapy, it should always be considered that calculation of different dose distribution in heterogenous tissue is important particularly on lung which has low density and large volume. To take precise dose distribution of 6MV X-ray in the thoracic cage, the authors had made a tissue equivalent phantom for thorax, measured dose distribution by thermoluminescent dosimeter and mm dosimeter, and derived methmetical equation coincided with provided theoretical formula. In comparision with isodose curve on case of homogeneous soft tissue, dose of heterogeneous lung tissue had been shown increase about 4% per cm depth on one and multiportal field, less than 15% difference on rotation field for esophagus, and around 20% difference on rotation field for lung according to the degree of rotation angle that must be corrected by dose compensation.

  • PDF

Case Stories of Microgravity Survey for Shallow Subsurface Investigation (고정밀 중력탐사를 이용한 천부 지질구조 조사 사례)

  • Park Yeong-Sue;Rim Hyoungrae;Lim Mutaek;Koo Sung Bon;Kim Hag Soo;Oh Seok Hoon
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.181-186
    • /
    • 2005
  • Gravity method produces subsurface density distribution, which is direct information of soundness of basement. Therefore, microgravity is one of the most effective method for detections of limestone cavities, abandoned mine-shafts and other tunnels, The paper show the effectiveness of microgravity by three different field cases.

  • PDF

Leaching of Smelting Reduced Metallic Alloy of Spent Lithium Ion Batteries by the Mixture of Hydrochloric Acid and H2O2 (과산화수소를 혼합한 염산용액으로 폐리튬이온배터리의 용융환원된 금속합금의 침출)

  • Moon, Hyun Seung;Tran, Thanh Tuan;Lee, Man Seung
    • Resources Recycling
    • /
    • v.30 no.5
    • /
    • pp.25-31
    • /
    • 2021
  • Smelting reduction of spent lithium-ion batteries results in the production of metallic alloys in which reduced cobalt, nickel and copper coexist. In this study, we investigated the leaching of the metallic alloys containing the above three metals together with iron, manganese, and silicon. The mixture of hydrochloric acid and hydrogen peroxide as an oxidizing agent was employed, and the effect of the concentration thereof, the reaction time and temperature, and pulp density was investigated to accomplish the complete leaching of cobalt, nickel, and copper. The effect of the hydrogen peroxide concentration and pulp density on the leaching was prominent, compared to that of reaction time and temperature, especially in the range of 20 to 80℃. The complete leaching of the metals present in metallic alloys, except silicon, was accomplished using 2 M HCl and 5% H2O2 with a pulp density of 30 g/L for 150 min at 60℃.