• Title/Summary/Keyword: 평형시간

Search Result 836, Processing Time 0.035 seconds

Analysis of Metabolism and Effective Half-life for Tritium Intake of Radiation Workers at Pressurized Heavy Water Reactor (중수로원전 종사자의 삼중수소 체내섭취에 따른 인체대사모델과 유효반감기 분석)

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.2
    • /
    • pp.87-94
    • /
    • 2009
  • Tritium is the one of the dominant contributors to the internal radiation exposure of workers at pressurized heavy water reactors (PHWRs). This nuclide is likely to release to work places as tritiated water vapor (HTO) from a nuclear reactor and gets relatively easily into the body of workers by inhalation. Inhaled tritium usually reaches the equilibrium of concentration after approximately 2 hours inside the body and then is excreted from the body with a half-life of 10 days. Because tritium inside the body transports with body fluids, a whole body receives radiation exposure. Internal radiation exposure at PHWRs accounts for approximately 20-40% of total radiation exposure; most internal radiation exposure is attributed to tritium. Thus, tritium is an important nuclide to be necessarily monitored for the radiation management safety. In this paper, metabolism for tritium is established using its excretion rate results in urine samples of workers at PHWRs and an effective half-life, a key parameter to estimate the radiation exposure, was derived from these results. As a result, it was found that the effective half-life for workers at Korean nuclear power plants is shorter than that of International Commission on Radiological Protection guides, a half-life of 10 days.

Live Lines Tracing Method in Power Distribution System with 3-phase-4 wires (삼상 다중 접지 배전계통에서 활선로 추적 방법)

  • Zheng, Yan-peng;Byun, Hee-Jung;Shon, Sugoog
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.559-562
    • /
    • 2017
  • In city, tracing of power transmission lines is difficult due to compound installation of overhead and underground lines, transposition, bad view caused by trees or big buildings. It is hard problem for electrical technician on site to trace power transformers or power lines to serve customers in 3 phase -4 wires power distribution systems. It is necessary that the correct and fast tracing method is required for load balancing among distribution lines. Old technology use to trace off-lines with high power impulse injection. Our proposed method use to trace live lines with very small power high frequency signal injection. Typical power transformers in the distribution system prevent propagating the higher frequency carrier signal. The proposed method uses the limited propagation ability to identify the power transformer to serve customers. Two end communication terminals are required to be synchronized between them for determination on electrically same phases. Challenging issue is to achieve synchronization without GPS providing synchronizing time. A novel power transformer and wire identification system is designed and implemented. The system consists of a transmitter and a receiver with power-line communication module. Some experiments are conducted to verify the theoretical concepts in a big commercial building. Also some simulations are done to help and understand the concepts by using MATLAB Simulink simulator.

  • PDF

T800/AD6005계 복합재의 습기투과에 관한 연구

  • 박명규;류백능;최영보
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.35-36
    • /
    • 1997
  • 복합재는 강도가 높고 가볍기 때문에 최근 로켓의 연소관으로 널리 사용되고 있다. 그런데 이 복합재 로켓 연소관은 제조 후 대기 환경에 장기적으로 노출되어 있기 때문에 금속 연소관과는 달리 온도 또는 습도 등의 환경에 대한 영향을 고려해야 한다. 더구나 연소관은 내부에 추진제가 충전되어 있으므로 추진제의 기계적 특성이 습도에 민감함을 생각할 때 강도뿐만 아니라 습기의 투과도 또한 매우 중요한 고려 요소가 된다. 그러나 온/습도 변화에 따른 복합재 자체의 재료 특성 변화에 대한 연구는 많이 보고되었으나 습기의 투과 정도에 관한 연구는 자료가 미흡한 실정이다. 한편, 포화 함수율은 복합재에 따라서 차이가 있으나 T300/5208의 경우 문헌을 참조하면 20-$50^{\circ}C$에서 복합재 무게의 약 1.5% 정도이며 포화에 걸리는 시간은 약 100일 정도로 나타나 있다.본 연구에서는 수분이 복합재를 통하여 투과되는 정도를 고찰하기 위하여 $20^{\circ}C$,95%RH의 온/습도를 유지하는 수조를 제작하였고, 이 수조내에 보관한 복합재 연소관의 실린더 벽면으로 투과되는 습기를 측정하기 위하여 연소관 내에 습도 센서를 투입하여 상대습도를 직접 측정하였다. 복합재 연소관이 로켓에 사용될 때는 연소관 외부에 페인트로 피막 처리하고 연소관 내부에도 추진제와의 사이에 라이너가 접착되어 있어서 수분 침투 및 온도 등의 외부 환경조건에 견디기에 더 양호한 조건이나 본 연구에서는 복합재 자체의 특성을 고찰하기 위하여 섬유를 에폭시에 함침시켜 winding한 상태 그대로의 복합재 연소관 시료를 사용하였다. 습기의 투과는 내부에 라이너/인슐레이션이 피복되거나 또는 추진제가 충전된 경우 많은 감소효과를 보였다. 순수 복합재 연소관의 경우 수조에 넣고 평형에 도달한 후로부터 약 8개월의 습기 투과 상태를 볼대 벽면을 통하여 들어가는 water vapor flux는 $20^{\circ}C$,95%RH 에서 평균적으로 9.3163$\times$$10^{-8}$g/$m^2$sec로 나타났다. 이때 습기가 투과되는 연소관이 국지점을 평판으로 가정하고 Fick's law를 이용하여 구한 습기에 대한 복합재의 확산계수는 D=2.5$\times$$10^{-6}$$mm^2$sec였으며, 이는 다른 graphite/epixy 복합재의 확산계수와 유사한 값을 나타내고 있다. 또한 추진제가 충전된 연소관을 절단하여 밀폐한 후 95%RH 습도 조건에 보관함으로써 연소관 내부의 추진제 기계적 특성에 미치는 침투된 습기의 영향도 함께 고찰하였다. 추진제에 따라 차이는 있겠으나 추진제가 충전된 연소관은 순수 복합재 연소관에 비해 습기의 투과 정도가 작으며, 본 연소관에 충전된 RDX/AP계 추진제의 경우 추진제의 습기투과에 의한 추진제 물성 변화는 미미한 것으로 나타났다.

  • PDF

Shelf-life Estimation and Sorption Characteristics of Coated Ascorbic Acid by Fluidized Bed Coating (유동층 코팅 처리한 Ascorbic acid의 흡습특성 및 저장기간 예측)

  • Park, Su-Jung;Youn, Kwang-Sup
    • Food Science and Preservation
    • /
    • v.15 no.3
    • /
    • pp.332-339
    • /
    • 2008
  • This study was performed to investigate the sorption characteristics and shelf-life of coated ascorbic acid Stability of ascorbic acid, which oxidizes easily during storage and processing, was achieved by applying a fluidized bed coating using Zein-DP and HPMC-FCC as covering materials. The monolayer moisture content calculated using the GAB equation showed a higher level of significance than when calculated using the BET equation. The fit to the isotherm curve was in the order of Halsey, Caurie, Oswin and Khun. The equilibrium relative humidity prediction model was established in terms of time and water activity, it had higher significance. The stability of the coated ascoribic acid during storage was investigated in terms of radical-scavenging activity, which decreased with increasing time of storage and was more affected at higher storage temperatures. The quality reduction rate constant (k) was calculated by a first-order reaction rate. The reaction rate constant increased with increasing storage temperature. The shelf-life of Zein-DP-coated ascorbic acid was estimated to be 45.83 days at 20C and 63.19 days at 10C, and the shelf-life for HPMC-FCC-coated ascorbic acid was estimated to be 28.84 days at 20C and 36.14 days at 10, the ascorbic acid was 24.52 days at $20^{\circ}C$ and 27.22 days at $10^{\circ}C$, respectively. Therefore, the fluidized bed coating effectively increased the stability of ascorbic acid.

Analysis of 766 keV Gamma Peak from NPP Environmental Samples (원전주변 환경시료의 766 keV 감마선에너지 피크에 대한 해석)

  • Kim, Wan;Lee, Hae-Young;Yang, He-Sun;Park, Hae-Soo;Kim, Bong-Kuk;Park, Hwan-Bae;Kim, Hong-Joo;Lee, Sang-Hoon
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.4
    • /
    • pp.190-194
    • /
    • 2009
  • Gamma spectral results for macroalgae samples taken from the environment of Ulchin nuclear power plants in Korea (east coast), showed 766 keV peaks, which were identified as $^{95}Nb$ by several research institutes. After the enhancement of liquid radioactive waste disposal facility at Ulchin NPP site, the $^{95}Nb$ amount in the liquid radioactive waste outflow has drastically reduced, but the expected reduction in $^{95}Nb$ specific activity from environmental samples did not actually show up on gamma spectroscopy. Detailed re-investigation revealed that along with 766 keV peak, other peaks (63, 92 and 1001 keV) from $^{234}Th-^{234}mPa$ decay series were also detected on spectroscopy, and that the measured half lives of the four peaks were very close to known half life of $^{234}Th-^{234}mPa$ decay series, which is 24.1 day. The measured gamma yield ratios of 766 keV peak to 1001 peak were very close to known ratio 0.35 for $^{234}mPa$. It is concluded that 766 keV peaks on gamma spectroscopy of Ulchin NPP environmental samples were mainly from $^{234}mPa$, which is one of naturally occurring radionuclides.

Process Networks of Ecohydrological Systems in a Temperate Deciduous Forest: A Complex Systems Perspective (온대활엽수림 생태수문계의 과정망: 복잡계 관점)

  • Yun, Juyeol;Kim, Sehee;Kang, Minseok;Cho, Chun-Ho;Chun, Jung-Hwa;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.16 no.3
    • /
    • pp.157-168
    • /
    • 2014
  • From a complex systems perspective, ecohydrological systems in forests may be characterized with (1) large networks of components which give rise to complex collective behaviors, (2) sophisticated information processing, and (3) adaptation through self-organization and learning processes. In order to demonstrate such characteristics, we applied the recently proposed 'process networks' approach to a temperate deciduous forest in Gwangneung National Arboretum in Korea. The process network analysis clearly delineated the forest ecohydrological systems as the hierarchical networks of information flows and feedback loops with various time scales among different variables. Several subsystems were identified such as synoptic subsystem (SS), atmospheric boundary layer subsystem (ABLS), biophysical subsystem (BPS), and biophysicochemical subsystem (BPCS). These subsystems were assembled/disassembled through the couplings/decouplings of feedback loops to form/deform newly aggregated subsystems (e.g., regional subsystem) - an evidence for self-organizing processes of a complex system. Our results imply that, despite natural and human disturbances, ecosystems grow and develop through self-organization while maintaining dynamic equilibrium, thereby continuously adapting to environmental changes. Ecosystem integrity is preserved when the system's self-organizing processes are preserved, something that happens naturally if we maintain the context for self-organization. From this perspective, the process networks approach makes sense.

Experimental and FEMLAB Simulation Study of Ibuprofen Racemate Separation in HPLC (Ibuprofen Racemate의 HPLC 분리실험과 FEMLAB 전산모사 연구)

  • Lee, Eun;Chang, Sang-Mork;Kim, Jong-Min;Kim, Woo-Shick;Kim, In-Ho
    • KSBB Journal
    • /
    • v.21 no.3
    • /
    • pp.224-229
    • /
    • 2006
  • FEMLAB is a powerful interactive environment for modeling, solving all kinds of scientific and engineering problems based on partial differential equations(PDEs). Separation process of chiral compound in HPLC columns was simulated by FEMLAB. To study change of elution profile with isotherm models, non-competitive and competitive Langmuir adsorption isotherm were adopted. Separated material was (R, S)-ibuprofen [(R, S)-2-(4-isobutyl phenyl) propionic acid], an anti-inflammatory agent, which retain the pharmacological activity in the (S)-(+)-enantiomer. Sample concentrations were changed from 0.5 mg/ml to 2.0 mg/ml at a flow rate of 1 ml/min and flow rate varied from 1 ml/min to 3 ml/min at an ibuprofen concentration of 2.0 mg/ml and $20{\mu}l$ of injection volume. Simulated results were well fitted with experimental data.

A Study on the Variation of Groundwater Level in the Han River Estuary (The Effect of the Removing of a Weir) (한강 하구역에서의 지하수위 변화에 관한 연구(수중보 철거로 인한 영향))

  • Kim, Sang-Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.6
    • /
    • pp.589-601
    • /
    • 2008
  • The variation of groundwater level near the Shingok weir has been analyzed. To consider the soil inhomogeneity, coefficient of effective permeability was computed to be 0.313 m/day in the horizontal direction, and 0.0423 m/day in vertical direction. Anisotropic ratio is 7.19. The river water level drawdown (caused by the removing of the weir) causes the groundwater level drawdown, and 3 months are required for the new steady condition. and groundwater flows from Han river toward Gulpo stream before the removing of the weir, but when the weir removed, the flow direction changes. The groundwater level falls maximum 30 cm in the areas under the influence of Han river, but, in the areas near Kulpo stream, groundwater level falls about 10 cm. The amount of groundwater use in the study area was investigated to be $52m^3/day$ and in this condition, groundwater level falls maximum 1m (before or after the removing of Shingok weir). therefore, the variation of groundwater level caused by the removing of Shingok weir is less than that caused by the usual use of groundwater.

Characteristics of Submarine's Turbulent Wake using Analytical Solution of B(ξ) for the given λ (임의 λ에 대한 근사해 B(ξ)를 이용한 잠수함 난류항적 특성 연구)

  • Lee, Yong-Chol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.8
    • /
    • pp.1604-1610
    • /
    • 2017
  • Using analytical solution of $B({\xi})$, I could find out the characteristics of Submarine's turbulent wake for the given various ${\lambda}$, which were unknown facts before. As the results, $B({\xi}){\approx}{\frac{B({\xi})_{max}}{2}}$ and ${{\int}_{0}^{{\approx}0.6}}B({\xi})d{\xi}{\approx}0.85{{\int}_{0}^{1}}B({\xi})d{\xi}$ in the vicinity ${\xi}{\approx}0.6$, there was some dependencies on the given ${\lambda}$ though. The values of ${\lambda}$, in the range of $4{\leq}{\lambda}{\leq}8$, are more suitable to describe submarine's turbulent wake realistically, due to the bases on the quasi equilibrium state of turbulent wake. ${\lambda}$ mainly affects on the radius and detection range of the submarine's turbulent wake on the surface, however, the speed of submarine mainly affect on the duration of the wake rather than shape. If $7{\leq}{\lambda}{\leq}8$, it can be expected that the turbulent wake can be seen on the surface in the West sea, however, snorkeling(or snorkeled) submarine's wake can be found easily in the East sea.

A Study on the Stability of the Ca-Bentonite Colloids Using a Dynamic Light Scattering Method (동적광산란 방법을 이용한 칼슘벤토나이트 콜로이드의 안정성에 대한 연구)

  • Baik Min-Hoon;Park Jong-Hoon;Cho Won-Jin
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.3
    • /
    • pp.12-19
    • /
    • 2006
  • In this study, the stability of Ca-bentonite colloids from Gyeongju area was studied by investigating the changes in the size of the bentonite colloids using a dynamic light scattering method depending on the geochemical conditions such as pH and ionic strength. Kinetic and equilibrium coagulation behavior of the bentonite colloids was investigated by changing the pH and ionic strength of the bentonite suspensions. The results showed that the stability of the bentonite colloids strongly depended upon contact time, pH, and ionic strength. It was also shown that the bentonite colloids were unstable at higher ionic strength greater than 0.01 M $NaClO_4$ at whole pH values considered. In addition, the stability ratio Wand the critical coagulation concentration (CCC) were also calculated using the data from the kinetic coagulation experiments. The stability ratio W was decreased as the ionic strength increased and varied with pH depending on the ionic strength. The CCC of the Ca-bentonite colloids was about 0.05 M $NaClO_4$ around pH 7.