A Study of Polarity Effect of Parallel Plate Type ionization Chamber with Different Volume (평행평판형 전리함의 두 전극간의 거리에 따른 극성효과 연구)

  • 윤형근;신교철
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.69-73
    • /
    • 2002
  • Exposure measurement data with parallel plate ionization chambers were known to depend on the polarity ($k_{pol}$) effect. In this work, the polarity effect were investigated for three parallel plate ionization chambers with different volume. The ionization chamber was fabricated using acrylic plate for the chamber medium and printed circuit board for electrical configuration. The various sizes of the sensitive volumes designed so far were 0.9, 1.9, and 3.1 co. High voltage generator was fabricated using the conventional 9 V batteries to apply the high voltage (300-500 V) to the electrode of the parallel plate ionization chamber. The gap between two electrodes ranged from 3, 6, and 10mm. As the result of our experiment, the polarity effect was within 0.5% in photon beam and 1% to 3.5% in the electron beams. Among electron beams, 16 MeV beam, which had highest energy, showed less polarity effect than electron beams with other energies.

  • PDF

DR (Digital Radiography) 적용을 위한 Biology 초음파 특수용매를 이용한 $PbI_2$ 합성법

  • Kim, Seong-Heon;Yun, Min-Seok;O, Gyeong-Min;Kim, Yeong-Bin;Lee, Sang-Hun;Jo, Gyu-Seok;Park, Hye-Jin;Nam, Sang-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.146-146
    • /
    • 2009
  • 최근에 광도전체와 형광체를 기반으로 평판형 디지털 방사선 검출기의 상업적 발전가능성에 많은 관심을 가지고 있다. 본 연구는 기존의 직접변환방식에 널리 사용되었던 비정질 셀레늄 (amorphous selenium) 기반의 디지털 방사선 검출기보다 높은 전기적신호 및 동작특성을 가지는 물질층을 제작하기 위해 High Purity (99.99%)의 상용화된 $PbI_2$를 특수용매에 담가두었다가 약 1시간동안 Biology 초음파 처리한 후 농축기를 사용하여 건조된 $PbI_2$를 3Roll-milling을 사용하여 미세크기의 Powder를 얻어내었다. 합성된 $PbI_2$ Powder를 PIB(Particle-in-Binder)법을 이용하여 전도성을 가진 ITO(Indium-tin-oxide)코팅된 유리판에 제작된 필름의 상부에 Magnetron sputtering system 을 사용하여 전극을 $1cm{\times}1cm$의 크기로 증착하였다. I-V 테스트를 통하여 X선 조사시 $PbI_2$필름의 Sensitivity, Dark current, SNR(signal-to-noise ratio)을 측정하여 필름의 전기적 검출 특성을 정량적으로 평가하였고 SEM(scanning electron microscope)을 통하여 입자의 크기를 관찰하였다.

  • PDF

The Design and Fabrication of Conversion Layer for Application of Direct-Detection Type Flat Panel Detector (직접 검출형 평판 검출기 적용을 위한 변환층 설계 및 제작)

  • Noh, Si-Cheol;Kang, Sang-Sik;Jung, Bong-Jae;Choi, Il-Hong;Cho, Chang-Hoon;Heo, Ye-Ji;Yoon, Ju-Seon;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.73-77
    • /
    • 2012
  • Recently, Interest to the photoconductor, which is used to flat form X-ray detector such as a-Se, $HgI_2$, PbO, CdTe, $PbI_2$ etc. is increasing. In this study, the film layer by using the photoconductive material with particle sedimentation was fabricated and evaluated. The quantization efficiency of the continuous X-ray with the 70 kVp energy bandwidth was analyzed by using the Monte Carlo simulation. With the results, the thickness of film with 64 % quantization efficiency was 180 ${\mu}m$ which is similar to the efficiency of 500 ${\mu}m$ a-Se film. And $HIg_2$ film has the high quantization efficiency of 74 % on 240 ${\mu}m$ thickness. The electrical characteristics of the 239 ${\mu}m$ $Hgl_2$ films produced by particle sedimentation were shown as very low dark current(under 10 $pA/mm^2$), and high sensitivity(19.8 mC/mR-sec) with 1 $V/{\mu}m$ input voltage. The SNR, which is influence to the contrast of X-ray image, was shown highly as 3,125 in low driving voltage on 0.8 $V/{\mu}m$. With the results of this study, the development of the low-cost, high-performance image detector with film could be possible by replacing the film produced by particle sedimentation instead to a-Se detector.

Research on Image Quality and Effective dose by Exposure Index Variation (Exposure Index변화에 따른 Image Quality와 Effective dose에 대한 연구: a Monte Carlo Simulation Study)

  • Kim, Hyun Soo;Jeong, Jae Ho;Lee, Jong Woong
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.63-69
    • /
    • 2013
  • Comparing with film-screen system, flat-panel detector has extensive dynamic range. Focusing flat-panel detector, whole body human phantom PBU-50 (Kyoto, kagaku, Japan) was used to perform comparative study of the estimate of image quality and exposure dose. the exposure condition was 81kV and 20mAs, which is used for Abdomen supine exam in clinical area. As a result of the kV change of the interpreted medical image which has over 30dB of PSNR value, the value of DAP shows the difference of 19.6 times. Moreover, the result of comparing kV change with effective dose of ICRP 103 shows that stochastic effect was increased by over exposure. Therefore, it is significantly necessary that digital radiation technical chart will be used to obtain high quality image and make the standard of dose by educating radio-technologist continually.

Comparison of Modulation Transfer Function in Measurements by Using Edge Device angle in Indirect Digital Radiography (간접평판형 검출기에서 변조전달함수 측정 시 Edge 각도에 따른 비교 연구)

  • Min, Jung-Whan;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.42 no.4
    • /
    • pp.259-263
    • /
    • 2019
  • This study was purpose to compare image quality of Indirect digital radiography (IDR) system by using the International electro-technical commission standard(IEC 62220-1) which were applied to IEC in medical imaging. To evaluation the analysis of Modulation transfer function(MTF) measurements edge device each angle by using edge method. In this study, Aero (Konica, Japan) which is Indirect flat panel detector(FPD) was used, the size of image receptor matrix $1994{\times}2430$ which performed 12bit processing and pixel pitch is $175{\mu}m$. In IEC standard method were applied to each angle were compared. The results of shown as LSF at $2.0^{\circ}$ and $3.0^{\circ}$ angeles. Shape is constant and shows smooth shape. The amount of data seemed reasonable and 2.19 cycles/mm and 2.01 cycles/mm at a spatial frequency of $2.0^{\circ}$ and $3.0^{\circ}$ at an MTF value of 0.1. At an MTF value of 0.5, the spatial frequencies were $2.0^{\circ}$ and 1.11 cycles/mm and 0.93 cycles/mm at an angle of $3.0^{\circ}$. This study were to evaluate MTF by setting the each $2{\sim}3^{\circ}$ each angle and to suggest the quantitative methods of measuring by using IEC.

Analysis of the Signal Properties of Polycrystalline $HgI_2$ Film Detector under Radiographic Irradiation Condition (X-선촬영 조사 조건하에서 다결정 요오드화수은 박막검출기의 신호특성 분석)

  • Kim, Jong-Eon
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.289-294
    • /
    • 2010
  • The purpose of this study is an evaluation of the performance of a detector under radiographic irradiation condition by fabricating the polycrystalline $HgI_2$ film detector. The polycrystalline $HgI_2$ film detectors with thickness of 210 and $320\;{\mu}m$ were fabricated by screen print technology. Measurements of X-ray sensitivity and dark current were performed for two detectors. And measurements of the linearity of X-ray response and reproducibility were performed for the detector of thickness $320\;{\mu}m$. For applied electric field strengths from 0.05 to $2\;V/{\mu}m$ to the detector of thickness $320\;{\mu}m$, the X-ray sensitivities were measured from 233 to $1,408{\times}106\;electrons/mR{\cdot}mm^2$. And the dark currents were measured from 3.2 to $118\;pA/mm^2$. Compared with values reported by Zhong Su et al., the X-ray sensitivities exhibit about two times larger than the X-ray sensitivities measured by Zhong Su et al. And the dark currents exhibit about nine times larger than the dark currents measured by Zhong Su et al. The linearity of X-ray response acquired 0.988 as a coefficient of correlation (r). Reproducibility acquired 0.002 as a coefficient of variation. This study provides the performance data of fabricated polycrystalline $HgI_2$ film detector available for an active matrix flat panel imager under radiographic irradiation condition.

Comparison of Noise Power Spectrum in Measurements by Using International Electro-technical Commission Standard Devices in Indirect Digital Radiography (간접평판형 검출기에서 국제전자기술위원회 기준을 통한 잡음전력스펙트럼 비교 연구)

  • Min, Jung-Whan;Jeong, Hoi-Woun;Kim, Ki-Won;Kwon, Kyung-Tae;Jung, Jae-Yong;Son, Jin-Hyun;Kim, Hyun-Soo
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.457-462
    • /
    • 2018
  • The purpose of this study was to compare image quality of indirect digital radiography (IDR) system using the International Electro-technical Commission standard (IEC 62220-1), and to suggest the analysis of noise power spectrum (NPS) which were applied to IEC 62220-1 in medical imaging. In this study, Pixium 4600 (Trixell, France) which is indirect flat panel detector (FPD) was used. The size of image receptor (IR) is $7{\times}17$ inch (matrix $3001{\times}3001$) which performed 14bit processing and pixel pitch is $143{\mu}m$. In IEC standard, NPS evaluation were applied to RQA3, RQA5, RQA7 and RQA9. Because of different radiation quality, each region of interesting (ROI) were compared. The results of NPS indicated up to $3.5mm^{-1}$ including low Nyquist frequency. RQA5 indicated the lowest NPS and the others indicated higher NPS results relatively. NPS result of ROI a38 was higher than ROI a92 and this result indicated that there are more noise in left (cathode) than right (anode). This study were to evaluate NPS by using different radiation quality and setting the each ROI, and to suggest the quantitative methods of measuring NPS.

Characteristics of Detectors for Measurements of Photon Depth Doses in Build-Up Region (선량보강(Build-up) 영역에서의 광자선 깊이선량률 측정을 위한 검출기의 특성 비교)

  • Kang Sei-Kwon;Park Suk Won;Oh Do Hoon;Park Hee Chul;Kim Su Ssan;Bae Hoonsik;Cho Byung Chul
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.77-81
    • /
    • 2005
  • To determine the appropriate method out of various available methods to measure build-up doses, the measurements and comparisons of depth doses of build-up region including the surface dose were executed using the Attix parallel-plate ionization chamber, the Markus chamber, a cylindrical ionization chamber, and a diode detector. Based on the measurements using the Attix chamber, discrepancies of the Markus chamber were within $2\%$ for the open field and increased up to $3.9\%$ in the case of photon beam containing the contaminant electrons. The measurements of an cylindrical ionization chamber and a diode detector accord with those of the Attix chamber within $1.5\%\;and\;1.0\%$ and after those detectors were completely immersed in the water phantom. The results suggest that the parallel-plate chamber is the best choice to measure depth doses in the build-up region containing the surface, however, using cylindrical ionization chamber or diode detector would be a reasonable choice if no special care is necessary for the exact surface dose.

  • PDF

Detection and Analysis of Partial Discharges in Insulation Oil by a Monopole Antenna (모노폴 안테나에 의한 유중 부분방전의 검출과 분석)

  • Park, Dae-Won;Lee, Jung-Yoon;Kim, Min-Su;Kil, Gyung-Suk;Cheon, Sang-Gyu
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.10a
    • /
    • pp.69-69
    • /
    • 2011
  • 본 논문에서는 유입변압기의 절연진단을 위한 기초연구로 유중 부분방전에 의해 발생하는 전자파의 검출과 분석에 대하여 기술하였다. 유중 방사전자파 측정에는 공진주파수가 1 GHz인 모노폴 안테나를 제작하였다. 절연유 내부에 침-평판 전극계를 설치하고 0~50 kV까지 고전압을 인가시키면서 유중 부분방전의 발생을 모의하였다. 실험결과, 92.3 pC의 부분방전 발생시 1.28 V의 신호가 검출되었다.

  • PDF

Image Quality Evaluation of Digital X-ray Image and Film Image using Contrast Method (Contrast Method를 이용한 디지털 X선 영상과 필름 영상의 영상 질(Quality) 평가)

  • Park, Ji-Koon;Jung, Bong-Jae;Choi, Jang-Yong;Kang, Sang-Sik
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.9-15
    • /
    • 2011
  • In this paper, an image quality evaluation of amorphous selenium based x-ray system was performed using modulation transfer function (MTF) measurement. MTF as a main factor of imaging quality evaluation was investigated by contrast method from acquired test pattern image. The MTF value was measured to 36.1% at 3.0 lp/mm which is twice as high as that in the film image. Compared with other studies, the results demonstrate that amorphous selenium based x-ray detector is clinically meaningful.