• 제목/요약/키워드: 평판관

검색결과 116건 처리시간 0.025초

평판관-루버핀 열교환기의 공기측 열전달 및 압력강하 특성에 관한 실험적 연구 (An Experimental Study on Heat Transfer and Pressure Drop of Air Side in a Plate-Louvered Fin Heat Exchanger)

  • 강병하;김석현;장혁재;박병규
    • 설비공학논문집
    • /
    • 제14권6호
    • /
    • pp.485-492
    • /
    • 2002
  • Heat transfer and pressure drop on the air side of a plate-louvered fin heat exchanger with new shape of louver fin have been investigated experimentally. Water is employed inside the flat tube to transfer heat with air for convenience. This problem is of particular interest in the design of a plate-louvered heat exchanger. The effect of air flow rate, water flow rate and water temperature on pressure drop as well as heat transfer in air side are studied in detail. The present results showed a good agreement qualitatively with the previous results in general. Based on the experimental data, f-factor and j -factor correlations of the present louvered-fin are suggested. It is also found that heat transfer could be enhanced with new shape of louver fin, compared with the conventional louvered-fin, while the f-factor remains unchanged.

알루미늄 다채널 평판관내 R22, R410A, Propane의 흐름 응축 열전달 성능 비교 (Flow Condensation Heat Transfer Coefficients of R22, R410A and Propane in Aluminum Multi-Channel Tube)

  • 박기정;이기영;정동수
    • 설비공학논문집
    • /
    • 제17권7호
    • /
    • pp.649-658
    • /
    • 2005
  • Flow condensation heat transfer coefficients (HTCs) of R22, R410, Propane (R290) were measured inside a horizontal 9 hole aluminum multi-channel flat tube. The main test section in the refrigerant loop was made of a 0.53m long multi-channel flat tube of hydraulic diameter of 1.4 mm. Refrigerant was cooled by passing cold water through an annulus surrounding the test section. Data were obtained in qualities of $0.1\~0.9$ at mass flux of $200\~400kg/m^2s$ and heat flux of $7.3\~7.7kW/m^2$ at the saturation temperature of $40^{\circ}C$. All popular heat transfer correlations in single-phase subcooled liquid flow and flow condensation originally developed for large single tubes predicted the present data of the multi channel flat tube within $25\%$ deviation when effective heat transfer area was used in determining experimental data. This suggests that there is little change in flow characteristics and patterns when the tube diameter is reduced down to 1.4 mm diameter range. Hence, a modified correlation based on the present data was proposed which could be applied to small diameter tubes with effective heat transfer area. The correlation showed a mean deviation of less than $20\%$ for all data.

유전체 장벽 방전 플라즈마의 Monostatic 레이다 단면적 측정 (Monostatic RCS Measurement for Dielectric Barrier Discharge Plasma)

  • 이현재;정인균;하정제;신웅재;양진모;이용식;육종관
    • 한국전자파학회논문지
    • /
    • 제27권3호
    • /
    • pp.246-252
    • /
    • 2016
  • 본 논문에서는 유전체 장벽 방전(dielectric barrier discharge: DBD) 플라즈마에 의한 monostatic RCS 감소 특성을 측정하였다. Monostatic 레이다 단면적(radar cross section: RCS) 교정을 위하여 서로 다른 크기의 금속 평판을 사용하여 산란계수(scattering parameter)를 측정하였고, 그 결과 0.4 dB 이내의 오차를 보였다. DBD 플라즈마에 의한 monostatic RCS 감소 특성을 측정하기 위해 DBD 플라즈마 발생기 뒤에 금속 평판을 배치하였다. 금속 평판과 플라즈마 발생기 사이에 아크 방전(arc dischrage)이 일어나는 것을 방지하기 위해 금속 평판과 DBD 플라즈마 사이의 간격을 띄워 측정을 진행하였다. 그 결과 7.4 GHz에서 monostatic RCS가 최대 약 3 dB 감소하였다.

알루미늄 다채널 평판관내 R22 대체냉매의 흐름 응축 열전달 성능 비교 (Flow Condensation Heat Transfer Coefficients of R22 Alternative refrigerants in Aluminum Multi-Channel Tube)

  • 이기영;이민행;정동수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.249-255
    • /
    • 2005
  • Flow condensation heat transfer coefficients(HTCs) of R22, R4IO, Propane(R290) were measured inside a horizontal 9 hole aluminum multi-channel flat tube. The main test section in the refrigerant loop was made of a 0.53 m long multi-channel flat tube of hydraulic diameter of 1.4 mm. Refrigerant was cooled by passing cold water through an annulus surrounding the test section. Data were obtained in qualities of 0.1 ${\sim}$ 0.9 at mass flux of $200{\sim}400$ $kg/m^2s$ and heat flux of $7.3{\sim}7.7$ $kW/m^2$ at the saturation temperature of $4^{\circ}C$. All popular heat transfer correlations in single-phase subcooled liquid flow and flow condensation originally developed for large single tubes predicted the present data of the multi channel flat tube within 25% deviation when effective heat transfer area was used in determining experimental data. This suggests that there is little change in flow characteristics and patterns when the tube diameter is reduced down to 1.4 mm diameter range. Hence, a modified correlation based on the present data was proposed which could be applied to small diameter tubes with effective heat transfer area. The correlation showed a mean deviation of less than 20% for all data.

  • PDF

사각돌출형 표면거칠기가 있는 이중동심원관 내의 난류유동과 열전달 (Turbulent Fluid Flow and Heat Transfer in Concentric Annuli with Square-Ribbed Surface Roughness)

  • 안수환;이윤표;김경천
    • 대한기계학회논문집
    • /
    • 제17권5호
    • /
    • pp.1294-1303
    • /
    • 1993
  • 본 논문은 Lee의 평행평판 채널내의 난류유동 모델을 사용하여 비대칭적 경계 를 갖는 이중관내 거칠기 표면위에서의 흐름을 취급하였다. 해석에서 표면거칠기는 속도 형상에 단지 국부적으로 영향을 미친다고 가정하여 한쪽 면에서만 사각형 거칠기 요소를 가진 평행관 사이의 유동에 관해 이미 얻은 실험 관계식을 이용하였다. 거칠 기의 합성효과는 압력손실 증가에 대한 열전달 증가에 대해 거친관과 매끈한 관의 경우를 비교한 값에 의하여 알수 있었다.그러므로, 전체적 효율측면에서 유리하게 열전달률을 증가시킬수 있는 이중관내의 바람직한 인공의 거칠기형태(P/.epsilon., S/.epsilon.,.alpha., etc.)를 얻을 수 있었다.

전자처리 스페클 간섭법에 의한 양단이 고정된 직사각형 평판의 진동모드 측정에 관 한 연구 (A Study on the Vibration Mode Measurement of Rectangular Plate with Two Parallel Sides Fixed by Electronic Speckle Pattern Interferometry)

  • 김경석
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1996년도 춘계학술대회 논문집
    • /
    • pp.85-90
    • /
    • 1996
  • In the word, there is varied types of vibration, and these affect the mechanical industry. In this paper is plates with two parallel sides fixed. Electronic speckle pattern interferometry (ESPI) is one of the optical nondestructive testing technique. By using the ESPI, vibration modes for excitation point, a/b(ratio of longuitudinal and lateral length), and kind of specimen are measured and compared qualitatively with theoritical analysis that Warburton proposed.

  • PDF

접촉한 두 평면과 균열한 틈새에서의 유동마찰계수 비교 (Comparison of the Friction-Loss Coefficient for the Gap of Two Contact Surfaces and a Crack)

  • 남호윤;최병해;김종범;이용범
    • 대한기계학회논문집B
    • /
    • 제35권10호
    • /
    • pp.1075-1081
    • /
    • 2011
  • 이중벽관 증기발생기에서 전열관의 내관과 외관 사이의 틈새에 채워진 헬륨가스의 압력변동으로 전열관의 파손을 감지하는 방법이 개발되고 있다. 이 현상을 모사하기 위해 압력으로 밀착된 두 평판사이의 미세한 틈새에서의 누설률을 측정하여 실험식을 개발하였다. 이 실험식에서는 틈새의 간격과 유동마찰계수가 표면조도에 의해 상호 결합된 형태로 기술되는데, 간단한 평판접촉 모델을 사용하여 유동마찰계수 식을 분리하였다. 이 실험식과 균열에서의 누설률 예측에 사용되고 있는 기존의 유동마찰계수 관련 실험식들을 상호 비교하였다. 레이놀즈 수의 적용범위가 상이함에도 불구하고 개발한 실험식이 0.1~0.35 에서는 레이놀즈 수가 높은 경우에 적용되는 실험식들과 유사한 값을 보였다.

T800/AD6005계 복합재의 습기투과에 관한 연구

  • 박명규;류백능;최영보
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 1997년도 제9회 학술강연회논문집
    • /
    • pp.35-36
    • /
    • 1997
  • 복합재는 강도가 높고 가볍기 때문에 최근 로켓의 연소관으로 널리 사용되고 있다. 그런데 이 복합재 로켓 연소관은 제조 후 대기 환경에 장기적으로 노출되어 있기 때문에 금속 연소관과는 달리 온도 또는 습도 등의 환경에 대한 영향을 고려해야 한다. 더구나 연소관은 내부에 추진제가 충전되어 있으므로 추진제의 기계적 특성이 습도에 민감함을 생각할 때 강도뿐만 아니라 습기의 투과도 또한 매우 중요한 고려 요소가 된다. 그러나 온/습도 변화에 따른 복합재 자체의 재료 특성 변화에 대한 연구는 많이 보고되었으나 습기의 투과 정도에 관한 연구는 자료가 미흡한 실정이다. 한편, 포화 함수율은 복합재에 따라서 차이가 있으나 T300/5208의 경우 문헌을 참조하면 20-$50^{\circ}C$에서 복합재 무게의 약 1.5% 정도이며 포화에 걸리는 시간은 약 100일 정도로 나타나 있다.본 연구에서는 수분이 복합재를 통하여 투과되는 정도를 고찰하기 위하여 $20^{\circ}C$,95%RH의 온/습도를 유지하는 수조를 제작하였고, 이 수조내에 보관한 복합재 연소관의 실린더 벽면으로 투과되는 습기를 측정하기 위하여 연소관 내에 습도 센서를 투입하여 상대습도를 직접 측정하였다. 복합재 연소관이 로켓에 사용될 때는 연소관 외부에 페인트로 피막 처리하고 연소관 내부에도 추진제와의 사이에 라이너가 접착되어 있어서 수분 침투 및 온도 등의 외부 환경조건에 견디기에 더 양호한 조건이나 본 연구에서는 복합재 자체의 특성을 고찰하기 위하여 섬유를 에폭시에 함침시켜 winding한 상태 그대로의 복합재 연소관 시료를 사용하였다. 습기의 투과는 내부에 라이너/인슐레이션이 피복되거나 또는 추진제가 충전된 경우 많은 감소효과를 보였다. 순수 복합재 연소관의 경우 수조에 넣고 평형에 도달한 후로부터 약 8개월의 습기 투과 상태를 볼대 벽면을 통하여 들어가는 water vapor flux는 $20^{\circ}C$,95%RH 에서 평균적으로 9.3163$\times$$10^{-8}$g/$m^2$sec로 나타났다. 이때 습기가 투과되는 연소관이 국지점을 평판으로 가정하고 Fick's law를 이용하여 구한 습기에 대한 복합재의 확산계수는 D=2.5$\times$$10^{-6}$$mm^2$sec였으며, 이는 다른 graphite/epixy 복합재의 확산계수와 유사한 값을 나타내고 있다. 또한 추진제가 충전된 연소관을 절단하여 밀폐한 후 95%RH 습도 조건에 보관함으로써 연소관 내부의 추진제 기계적 특성에 미치는 침투된 습기의 영향도 함께 고찰하였다. 추진제에 따라 차이는 있겠으나 추진제가 충전된 연소관은 순수 복합재 연소관에 비해 습기의 투과 정도가 작으며, 본 연소관에 충전된 RDX/AP계 추진제의 경우 추진제의 습기투과에 의한 추진제 물성 변화는 미미한 것으로 나타났다.

  • PDF

히트파이프 히트싱크에서 평판 휜-관으로 구성된 공기유동 냉각채널의 대류 열전달 특성에 관한 수치해석 (A Numerical Analysis of Convective Heat Transfer in Air Flow Channels of a Plate Fin-tube Matrix for Heat Pipe Heat Sinks)

  • 김성훈;신현명;김철주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권8호
    • /
    • pp.862-869
    • /
    • 2005
  • A study on convective cooling characteristics has been done in the channels with heat pipes and associated Plane fins Analysis with FLUENT V5.0 lies its Purpose on the possible enhancement of heat transfer capability between an existing three in-line arrayed heatpipes and an extending four in-line arrayed heatpipes with increasing channel width. Numerical analysis is limited to the laminar flow in an isolated flow channel by employing cyclic boundary conditions for calculation purposes. Friction factors for three and four in-line arrayed heatpipes are compared with experimental results. In addition, temperature behavior at the plate fin for the three in-line arrayed heatpipes is compared with experiment. Friction factors and overall channel heat transfer coefficients (and/or Nusselt numbers) are presented as a function of Reynolds number. An increase of number of heatpipes and channel width reults in a decrease of the friction factor and doesn't not result in an increase of heat transfer performance. However. considering the 25$\%$ increase of heat load accompanies with maximum 8$^{\circ}C$ rise of average temperature of heat pipes, the four in-line array with the increase of channel width of heat pipe heat sink can be considered appropriate.

경사지게 설치된 평행류형 알루미늄 열교환기의 공기측 전열 성능 (Air-side Performance of Aluminum Heat Exchangers at Different Inclination Angles)

  • 김도영;조진표;김내현;박내현;황준현
    • 설비공학논문집
    • /
    • 제20권3호
    • /
    • pp.181-188
    • /
    • 2008
  • The effect of inclination angle on the heat transfer and pressure drop characteristics of the brazed aluminum heat exchangers is experimentally investigated. Three samples having different fin pitches(1.25, 1.5 and 2.0 mm) were tested. Results show that heat transfer coefficient is not affected by the inclination angle. However, the friction factor increases as the inclination angle increases with negligible difference between the forward and backward inclination. Both the heat transfer coefficient and the friction factor are the smallest at $F_p=1.5mm$, followed by $F_p=2.0mm$ and 1.25mm. Possible explanation is provided considering the louver layout. Comparison with existing correlations is also made.