• Title/Summary/Keyword: 평균체류시간

Search Result 172, Processing Time 0.03 seconds

A Study on the Usage Behavior of Public Library Website through an Analysis of Web Traffic (웹 트래픽 분석을 통한 공공도서관 웹사이트 이용행태에 관한 연구)

  • Kang, Munsil;Kim, Seonghee
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.32 no.4
    • /
    • pp.189-212
    • /
    • 2021
  • The purpose of this study is to analyze an usage behavior for the public library website through web traffic. For this purpose, using Google Analytics and growth hacking technique, the data of A public library website log was analyzed for three months from August 1, 2021 to October 31, 2021. As a result of the study, the young age group of 18-24 years old and 25-34 years old recorded a high rate of new member registration, & it was found that the inflow rate through SNS was high for external inflows. As a result of analysis for the access rate by time, it was found that the time with the highest inflow rate was between 10 am and 11 am both on Wednesday and Friday. As a access channel, the access rate using mobile (64.90%) was quite high, but at the same time, the bounce rate (27.20%) was higher than the average (24.93%), & the rate of duration time (4 minutes 33 seconds) was lower than thee average (5 minutes 22 seconds). Finally, it was found that the utilization rate of reading program events and online book curation service, which the library focuses on producing and promoting, is very low. These research results can be used as basic data for future improvement of public library websites.

Evaluation of Radiation Exposure to Medical Staff except Nuclear Medicine Department (핵의학 검사 시행하는 환자에 의한 병원 종사자 피폭선량 평가)

  • Lim, Jung Jin;Kim, Ha Kyoon;Kim, Jong Pil;Jo, Sung Wook;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.32-35
    • /
    • 2016
  • Purpose The goal for this study is to figure out that medical staff except Nuclear Medicine Department could be exposed to radiation from the patients who take Nuclear Medicine examination. Materials and Methods Total 250 patients (Bone scan 100, Myocardial SPECT 100, PET/CT 50) were involved from July to October in 2015, and we measured patient dose rate two times for every patients. First, we checked radiation dose rate right after injecting an isotope (radiopharmaceutical). Secondly, we measured radiation dose rate after each examination. Results In the case of Bone scan, dose rate were $0.0278{\pm}0.0036mSv/h$ after injection and $0.0060{\pm}0.0018mSv/h$ after examination (3 hrs 52 minutes after injection on average). For Myocardial SPECT, dose rate were $0.0245{\pm}0.0027mSv/h$ after injection and $0.0123{\pm}0.0041mSv/h$ after examination (2 hrs 09 minutes after injection on average). Lastly, for PET/CT, dose rate were $0.0439{\pm}0.0087mSv/h$ after examination (68 minutes after injection on average). Conclusion Compared to Nuclear Safety Commission Act, there was no significant harmful effect of the exposure from patients who have been administered radiopharmaceuticals. However, we should strive to keep ALARA(as low as reasonably achievable) principle for radiation protection.

  • PDF

Early and Mid-Term Results of MIDCAB (최소 침습적 관상 동맥 우회술의 중단기 성적)

  • 손호성;방영호;황진욱;민병주;조양현;박성민;이성호;김광택;선경
    • Journal of Chest Surgery
    • /
    • v.37 no.10
    • /
    • pp.827-832
    • /
    • 2004
  • Background: The significance of MIDCAB is emerging topics recently as OPCAB is going to be universalized, and long-term outcome of bypass graft surgery was proved to be more excellent than balloon dilation or stent insertion. We report our MIDCAB results in 73 patients in the last three years. Material and Method: Retrospective analysis of medical records was done from November 1, 2000 through November 31, 2003. There were 47 males and 26 females ranging in age from 31 years to 79 years (average $61.3\pm9.8$ years). Observation periods after operative procedures were 10 to 1238 days (average $763\pm319.8$ days). Left longitudinal parasternal incision as a standard procedure was done to approach the heart after dissection of the left internal thoracic artery by partial or total resection of 3rd to 5th ribs. Result: Of those patients, 46 patients were transferred to ICU after extubation at operation room and 58 patients were extubated within 3 hours after operation. Average ICU staying periods was $26.8\pm11.5$ hours. Follow-up angiography during admission was done in 36 patients and showed 100% patency. Only one patient died on the 10$^{th}$ post operative day because of sudden CVA. Complications included wound problems in 4 patients, and constructing pericardial window using thoracoscopy due to continuous pericardial effusion in 1. Permanent pacemaker was inserted in one patient owing to sick sinus syndrome. In one patient with recurrence of angina 8 months after operation, stenosis at anastomic site was found and improved with balloon dilatation. Conclusion: We were satisfied with our results of MIDCAB in single and multi-vessel coronary artery disease. These results have made the cardiologists tried to operate positively and we expect widening operative indications including hybrid revascularization.

Clinical Outcomes of Off-pump Coronary Artery Bypass Grafting (심폐바이패스 없는 관상동맥우회술의 임상성적)

  • Shin, Je-Kyoun;Kim, Jeong-Won;Jung, Jong-Pil;Park, Chang-Ryul;Park, Soon-Eun
    • Journal of Chest Surgery
    • /
    • v.41 no.1
    • /
    • pp.34-40
    • /
    • 2008
  • Background: Off-pump coronary artery bypass grafting (OPCAB) shows fewer side effects than cardiopulmonary by. pass, and other benefits include myocardial protection, pulmonary and renal protection, coagulation, inflammation, and cognitive function. We analyzed the clinical results of our cases of OPCAB. Material and Method: From May 1999 to August 2007, OPCAB was performed in 100 patients out of a total of 310 coronary artery bypass surgeries. There were 63 males and 37 females, from 29 to 82 years old, with a mean age of $62{\pm}10$ years. The preoperative diagnoses were unstable angina in 77 cases, stable angina in 16, and acute myocardial infarction in 7. The associated diseases were hypertension in 48 cases, diabetes in 42, chronic renal failure in 10, carotid artery disease in 6, and chronic obstructive pulmonary disease in 5. The preoperative cardiac ejection fraction ranged from 26% to 74% (mean $56.7{\pm}11.6%$). Preoperative angiograms showed three-vessel disease in 47 cases, two-vessel disease in 25, one-vessel disease in 24, and left main disease in 23. The internal thoracic artery was harvested by the pedicled technique through a median sternotomy in 97 cases. The radial artery and greater saphenous vein were harvested in 70 and 45 cases, respectively (endoscopic harvest in 53 and 41 cases, respectively). Result: The mean number of grafts was $2.7{\pm}1.2$ per patient, with grafts sourced from the unilateral internal thoracic artery in 95 (95%) cases, the radial artery in 62, the greater saphenous vein in 39, and the bilateral internal thoracic artery in 2. Sequential anastomoses were performed in 46 cases. The anastomosed vessels were the left anterior descending artery in 97 cases, the obtuse marginal branch in 63, the diagonal branch in 53, the right coronary artery in 30, the intermediate branch in 11, the posterior descending artery in 9 and the posterior lateral branch in 3. The conversion to cardiopulmonary bypass occurred in 4 cases. Graft patency was checked before discharge by coronary angiography or multi-slice coronary CT angiography in 72 cases, with a patency rate of 92.9% (184/198). There was one case of mortality due to sepsis. Postoperative arrhythmias or myocardial in-farctions were not observed. Postoperative complications were a cerebral stroke in 1 case and wound infection in 1. The mean time of respirator care was $20{\pm}35$ hours and the mean duration of stay in the intensive care unit was $68{\pm}47$ hours. The mean amounts of blood transfusion were $4.0{\pm}2.6$ packs/patient. Conclusion: We found good clinical outcomes after OPCAB, and suggest that OPCAB could be used to expand the use of coronary artery bypass grafting.

Effect of Typhoon 'Rusa' on the Natural Yeon-gok Stream and Coastal Ecosystem in the Yeong-Dong Province (영동지방 자연형 하천(강릉 연곡천)과 인근 연안 생태계에 대한 태풍 루사의 영향)

  • Yoon Yi-Yong;Kim Hung-sub
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.7 no.1
    • /
    • pp.35-41
    • /
    • 2004
  • The yeongok stream originates at the natural park, Mt. O-dae and flows to the East Sea of korea, normally maintaining I or II grade of water quality and its average water flux is 352,100 ㎥/d. However, the typhoon 'Rusa', which occured on 31 August 2002, changed its watercourse and configuration, and the ecosystem was deeply damaged. Moreover, the hydrological characteristics were once more transformed, and the ecosystem was secondarily damaged during repair-work of destroyed bridges and elevations. After the flood disaster, the species diversity diminished 17% for attached diatom and 44% for aquatic animals. However, the earth and sand, dug from river bed during intensive repair-work throughout the entire stream, made diversity drop to 32% for the diatom and the aquatic animals were wiped out. Especially, fishes were totally destroyed except for some species such as Moroco oxycephalus in the upper stream. The yeongok stream has little contamination source and short water residence time due to the short length and rapid slope, and consequently a temporary deterioration of water quality caused by repair-work may be rapidly recovered, but it needs a long time to restore the damaged ecosystem.

  • PDF

Pharmacomkinetics of Roxithromycin after Intravenous Administration in Broilers (록시스로마이신의 정맥주사 후 육계에서의 약물동태학적 분석)

  • Lim Jong-Hwan;Park Byung-Kwon;Kim Myoung-Seok;Hwang Youn-Hwan;Yun Hyo-In
    • Journal of Veterinary Clinics
    • /
    • v.23 no.2
    • /
    • pp.87-90
    • /
    • 2006
  • The aim of the present study was to investigate the disposition pharmacokinetics of roxithromycin in broilers. Roxithromycin was administered at a single dose of 20 mg/kg body weight by intravenous (i.v.) routes. Plasma concentrations of roxithromycin were determined by liquid chromatography/mass spectrometry. After a single i.v. dose plasma concentrations were best fitted to a two-compartment open model. The values of the pharmacokinetic parameters after i.v. administration were: elimination half-life = $5.83{\pm}1.79h$, mean residence time = $6.33{\pm}0.32h$, total body clearance = $0.55{\pm}0.15L/h/kg$, and volume of distribution at steady state = $3.47{\pm}0.84L/kg$. The pharmacokinetic interpretation of roxithromycin after i.v. administration revealed that the drug was well distributed throughout the body in broilers and slowly eliminated. More studies for the application of roxithromycin against poultry disease are needed to establish a suitable pharmaceutical formulation, propose optimum dosage regimens, investigate clinical efficacy and study the tolerability of repeated doses.

A study on the effect of gusty wind on smoke control performance in road tunnel (돌풍이 도로터널의 제연성능에 미치는 영향 연구)

  • Baek, Doo-San;Cho, Hyeon-Seok;Lee, Seung-Chul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.1
    • /
    • pp.95-108
    • /
    • 2022
  • The increase in the use time of tunnel users due to the lengthening of the road tunnel may increase the evacuation time in case of fire, resulting in a large number of casualties. In order to reduce the casualties caused by fire, the "Road Tunnel Design Manual, Part 6 Tunnel" and "Road Tunnel Disaster Prevention Facility Installation and Management Guidelines" stipulate that ventilation facilities should be installed along with the extension of the tunnel. The ventilation system design factor considers the wind speed of the external natural wind to be at least 2.5 m/s, and it is applied upward according to the characteristics of the tunnel. As a result of analyzing the five-minute average wind speed data in the Daegwallyeong region for the past 6 years, it was analyzed that 15.8% of the windy days were winds of 10 m/s or more, and the maximum was 20 m/s. Therefore, in this study, when a fire occurs in a tunnel, the pattern of natural wind flowing into the tunnel and the backlayering distance of the tunnel fire smoke according to the maximum wind speed were analyzed. As a result, it was analyzed that a backflow of up to 490 m occurs when a gust of 20 m/s blows.

A Case Study on Phytoremediation in Polluted Stream by Heilianthus annuus (Heilianthus annuus에 의한 오염된 하천에서의 Phytoremediation에 관한 연구)

  • Choi, Moon-Sul
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.11 no.4
    • /
    • pp.165-171
    • /
    • 2006
  • This is the research to prepare a purification program for relatively less polluted stream by using phytoremediation. We calculated a treatment amount of nutrients followed by growth of Helianthus annuus (a kind of sunflower), setting up the plant reactor in the hothouse. Moreover, to investigate a field applicability, we could find increased contents of nitrogen, carbon and hydrogen in plants by setting up a H. annuus planted artificial floating island in an irrigation canal. When we changed the dissolved inorganic nitrogen(DIN) concentration of the influent from 28.5 to 199.2 mg/l and the dissolved inorganic phosphorus(DIP) concentration of the influent from 13.3 to 25.4 mg/l, growth disorder has not appeared though it is much higher than the criterion of water for irrigation. In this case, the removal rate of DIN was $81.7\sim98.6%$, and that of DIP was $81.9\sim98.4%$ in 3 days stay on average. It has appeared that the efficient hydraulic retention time(HRT) was 48 hours. The following contents of nitrogen, carbon and hydrogen of H. annuus appeared in the artificial floating island: nitrogen was $3.2\sim7.8%$ in the trunk and $3.0\sim6.3%$ in the root. Carbon was $40.1\sim57.7%$ in the trunk and $43.4\sim53.8%$ in the root.

Determinants of the Location and Relocation of Domestic Logistics Firms in Korea (focused on complementary commodity flow survey for 2006) (우리나라 국내 화주기업의 입지 및 재입지 선택 특성 분석 (2006년 물류현황보완조사를 중심으로))

  • Do, Hwa-Yong;Jang, Hoon;Kim, Chan-Sung;Won, Jai-Mu
    • Journal of Korean Society of Transportation
    • /
    • v.26 no.1
    • /
    • pp.37-49
    • /
    • 2008
  • In general, most of the firms do not settle down in one place for their pursuit of profit. There are many reasons for the relocation of the firms; procurement of raw material, market area, transportation cost and housing cost. The aspect of national policy, firm relocation has been systemically promoted for the purpose of logistics system efficiency. Nowadays balanced regional development has been issue. Another aspect, many countries have struggled for the preoccupancy of new place because of its production cost saving and curtailment of expenditure. The aim of this article is qualitative and quantitative analysis of relocation influence factors of domestic goods firms in Korea. This article dynamically analyzed the relocation influence factors for domestic goods firms in Korea. For the analysis this article made use of complementary survey (2006) out of the 3rd national logistics survey (2005). The complementary survey conducted pre-business district, business period, relocation reason, etc. This article dynamically analyzed from the three aspects; observation of average residence time in one business district, relocation factors, influence of market area. Analysis shows that relocation of firm is very high rate and the reasons of relocation play compositeness role. The results of determinants of location, firms approach the established market area closely and the firm's relocation is influenced by market area.

Variation of cyanobacteria occurrence pattern and environmental factors in Lake Juam (주암호 유해남조류 출현양상과 환경요인 변화)

  • Chung, Hyeonsu;Son, Misun;Ryu, Hui-Seong;Park, Chang Hee;Lee, Rury;Cho, Misun;Lim, Chaehong;Park, Jonghwan;Kim, Kyunghyun
    • Korean Journal of Environmental Biology
    • /
    • v.37 no.4
    • /
    • pp.640-651
    • /
    • 2019
  • The study analyzed the relationship between harmful cyanobacteria and physicochemical factors in Lake Juam from 2005 to 2018. The research locations were designated St. 1 (Juam-Dam) and St. 2 (Sinpyong). Harmful cyanobacteria was found in four genera (Microcystis sp., Anabaena sp., Aphanizomenon sp., Oscillatoria sp.). The average standing crops of harmful cyanobacteria in both locations were 2,575 cells mL-1 and 2,557 cells mL-1 from 2005 to 2011. Since 2012, there has been a significant decrease that the measurements were 42 cells mL-1 and 82 cells mL-1 from 2012 to 2018. To analyze the reason for the decrease in harmful cyanobacteria, Pearson's correlation and t-tests were performed on data collected during the summer period (June-September). Pearson's correlation showed a significantly positive correlation with total nitrogen(TN), outflow, and storage and a negative correlation with electrical conductivity. T-tests were conducted in two different periods and showed decreases in total nitrogen, electrical conductivity, and residence time. The average rainfall was decreased from 263.3 mm (2005-2011) to 219.9 mm (2012-2018) and total nitrogen was decreased from 0.912 mg L-1 (2005-2011) to 0.811 mg L-1 (2012-2018) and the same variability was seen in TP (total phosphorus). Therefore, it seems that the low-rainfall decreased the nutrients (TN) and variability in the TP, resulting in a decrease in harmful cyanobacteria in Lake Juam.