The Journal of Korean Institute of Electromagnetic Engineering and Science
/
v.29
no.7
/
pp.484-490
/
2018
This paper describes an algorithm for calculating load impedance by measuring voltage and current components using a VI sensor in a 13.56 MHz impedance automatic matching system. We propose an algorithm that improves the error rate by using an arbitrary complex calibration load instead of the conventional $50{\Omega}$ calibration load. The error rate is targeted to attain average values of $R_{IN}$ and $X_{IN}$ at 1% and 20% or less, respectively. First, the IF frequency is calculated using a mixer to reduce the error rate. Second, when the arbitrary complex load is used as the calibration load, the error rate $R_{IN}$ decreased from 4.7 % to 0.3 % on average, and $X_{IN}$ decreased from 102 % to 18.3 % on average.
Proceedings of the Korea Water Resources Association Conference
/
2008.05a
/
pp.770-774
/
2008
현장 계측을 통한 오염부하량 산정은 많은 시간, 노력, 비용을 필요로 한다. 이러한 어려움을 해결하기 위해 오염부하 추정에 관한 많은 방법론들이 제시되고 있으며 개발되고 있는 중이다. 논오염부하 추정을 위한 일환으로 강우사상평균농도(Event Mean Conentration, EMC)에 관한 연구가 많이 진행되고 있다. 하지만, 오염부하량 산정을 위해서는 농도이외의 주요 매개변수인 유출량 산정 또한 중요하다. 하지만 논의 경우 실제 유출량 자료는 흔치 않다. 우리나라의 경우 영농활동이 시기별, 지역별로 비슷한 형태를 가지고 있으므로 이러한 점을 이용하면 유출율을 추정하는데 용이할 것으로 판단된다. 따라서 본 연구는 2004년부터 2007년 영농기 강우-유출량 실측 자료를 이용하여 시기별 유출특성을 파악하고, 논의 시기별 유출율을 제안하였다. 논의 시기별 유출율을 산정하기 위한 시험지구는 영산강 수계내에 위치한 전라남도 함평군 엄다면 화양리 13.69 ha 논지구이며, 2004년부터 2007년 영농기(5월$\sim$9월)동안 모니터링을 실시하였다. 논 배수로 말단에 수위계를 설치하여 수위-유량관계식을 이용하여 유량을 구하였고, 직선분리법을 이용하여 직접유출과 기저유출을 분리한후 강우량과 유출량의 비를 통하여 월별 평균 유출율을 산정하였다. 5월, 6월, 7월, 8월, 9월에 내린 평균 강수량은 각각 40.2, 50.1, 75.4, 75.8, 136.8 mm로 나타났고, 영농기 월별 평균 직접유출량은 각각 9.1, 26.6, 34.6, 42.9, 79.6 mm로 나타났다. 강우량과 유출량의 비를 통해 4개년 5월, 6월 7월 8월 9월 평균 유출율은 각각 0.18, 0.42, 0.40, 0.44, 0.49로 나타나 논의 경우 시기별로 유출율이 차이가 있는 것으로 조사되었다.
Ju, So Hee;Park, Woon Ji;Shin, Jae Young;Lee, Su In;Choi, Joong Dae
Proceedings of the Korea Water Resources Association Conference
/
2016.05a
/
pp.552-552
/
2016
논의 경우 다양한 영향인자에 의해 비점오염물질이 배출되기 때문에 유출특성을 파악하기가 어렵다. 따라서 본 연구의 목적은 논에서 발생하는 비점오염물질의 유출 특성에 대해 파악하여 추후 효율적인 농업비점오염 관리를 위한 기초자료를 제공하는데 있다. 연구 대상지점으로 춘천시에 위치한 논 1곳(면적: $11,130m^2$)을 선정하였으며. 2014년 5월부터 9월까지 총 11회(9회 유출)의 강우 사상에 대한 오염물질별 오염부하 및 유량가중평균농도(Event Mean Concentration, EMC)를 산정하였다. 모니터링기간 동안 발생된 강우량의 범위는 2.6~95.8 mm로 나타났으며, 선행무강우일수는 0.59~21.2일, 강우강도는 0.33~5.13 mm/hr의 범위로 나타났다. 총 유출량은 $0.16{\sim}497.3m^3$, 유출율은 0.01~0.47(평균 0.24)의 범위로 나타났다. 오염물질별 EMC는 SS 17.1~55.3 mg/L(평균 31.9 mg/L), BOD 1.9~9.7 mg/L(평균 4.2 mg/L), COD 3.6~18.9 mg/L(평균 8.3 mg/L), TOC 3.4~17.4(평균 6.4 mg/L) mg/L, T-N 1.64~7.17 mg/L (평균 3.79 mg/L), T-P 0.16~1.04 mg/L(평균 0.44 mg/L)의 범위로 나타났다. 각 강우사상에 대한 단위면적당 오염부하는 SS 0.005~19.56 kg/ha, $BOD_5$ 0.001~1.70 kg/ha, $COD_{Mn}$ 0.003~3.15 kg/ha, TOC 0.002~1.81 kg/ha, T-N 0.001~0.822 kg/ha, T-P 0.00003~0.115 kg/ha의 범위로 산정되었다. 논의 경우에는 초기유출 발생에 따른 오염부하의 급격한 변화가 없었고, 누적오염부하량비의 그래프도 강우사상의 기울기가 직선에 가깝게 나타났다. 하지만 지속적으로 오염물질을 배출하는 경향과 다양한 조건에 따라 배출양상이 달라지기 때문에 효과적인 관리를 하기 위해서 장기적인 모니터링 연구가 필요할 것으로 사료된다.
에너지 절약적 차원에서 한 대의 실외기에 다수의 실내기가 접속되는 개별공조형 멀티 열펌프에 관한 연구 및 개발과 보급이 증대되고 있다. 본 연구에서는 복수의 실내기를 갖고 가변속 압축기를 채용한 지열원 물대공기 멀티열펌프시스템을 학교 현장에 설치하여 제조사의 운전 제어 알고리즘에 따라 일일 냉난방 실증 성능 특성을 분석하였다. 2008년 9월 30일의 냉방부하가 낮은 일자에 대하여 시간에 따른 부하 변동에 따라 압축기의 용량가변으로 실내기 냉방용량은 정격용량 대비 17.1%에서 111.3%의 범위에서 변이되었으나, 열펌프 유닛의 일일 최대 COP는 6.2를 나타냈으며, 일일 평균 열펌프 유닛 COP는 4.5로 열펌프 유닛 인증 기준 이상의 성능을 나타냈다. 2008년 11월 10일 대비 2008년 12월 15일에는 시스템 가동 중의 평균 외기온도가 $9.6^{\circ}C$ 감소하였으나, 각 재실공간의 용도별 부분 부하특성으로 11월 10일 보다 난방 부하량이 작게 나타났다. 하지만, 12월 15일에는 부하량이 매우 작아서 11월 10일보다 잦은 압축기 가변에 따른 손실로 일일 평균 COP가 낮게 나타났다. 2009년 1월 12일에는 정격 용량대비 94%의 부하율로 11월 10일과 12월 15일 대비 4배 이상의 부하량으로 압축기 용량 가변율이 작아서 난방용량과 COP 변화율이 작게 나타났다. 2009년 1월 12일에는 지중순환수의 실외열교환기 유입온도가 2008년 12월 15일보다 감소하고, 시스템의 난방용량 증가로 상대적으로 응축기와 증발기 크기가 감소한 효과로 히트펌프 유닛 COP가 감소하였으나, 본 지열원 열펌프 제조사에서 생산하고 있는 본 지열원 시스템과 동일한 압축기 등을 채용한 동일 용량의 공기열원 열펌프의 1월 12일 외기온도 $-10^{\circ}C$에서의 열펌프 유닛 COP 대비 70% 우수한 성능을 나타냈다. 본 지열원 히트펌프의 2008년 11월 10일의 일일 평균 히트펌프 유닛 COP는 외기온도가 낮고 일일 부하량이 크게 나타난 1월 12일의 일일 평균 히트펌프 유닛 COP 대비 37% 높게 나타났으나, 지중순환펌프의 정속운전으로 시스템 요구 지중순환수 유량 증가에 따른 성능 향상보다 소비전력 증가 영향이 커서 1월 12일의 시스템 COP 보다 33.3% 작은 값을 나타냈다. 본 연구의 용량 가변형 압축기를 채용한 지열원 멀티 히트펌프 유닛을 지열원 냉난방 시스템의 히트펌프 유닛으로 사용할 경우 시스템 최적화를 통한 시스템 COP 향상과 연간에너지 절감을 이루기 위해서는 히트펌프의 용량 변화 시에 지중순환펌프의 순환 유량 최적화를 위한 효율적 운전 제어 알고리즘 개발이 요구된다.
The Journal of Korean Institute of Communications and Information Sciences
/
v.32
no.3B
/
pp.168-174
/
2007
All of users who connect to mobile game want to play seamless real-time game without any loads on game servers. However, as for existing methods, it is not available to effectively distribute server loads. Therefore, in this paper, we design and implement an uniform variance-based load balancer for distributing loads of game servers for wireless online games by suitable load balancing methods. With this methods, we can deal with dynamically increasing game servers as the information about load balancing of specific period is applied to the administrator.
Proceedings of the Korean Society for Agricultural Machinery Conference
/
2017.04a
/
pp.11-11
/
2017
지속적인 고령화 추세에 따라 여성과 고령층의 노동력이 차지하는 비율이 높아지고 있어, 사용하기 편리한 소형농기계의 요구가 증가하고 있는 실정이다. 본 연구에서 사용한 소형 관리기는 정식 작업 전 경운, 정지 등 다양한 작업이 가능한 농기계이다. 본 연구에서는 소형 관리기에 토크 측정 시스템을 구성하였으며, 작업 중 가장 큰 부하를 받는 구굴 작업 부하를 측정하였다. 또한, 작업 시 가장 직접적으로 영향을 받는 PTO (Power Take Off) 기어의 부하 용량(load capacity)을 기어 해석 소프트웨어를 이용하여 분석하였다. PTO 기어의 부하 용량은 안전율, 피로수명을 대상으로 평가하였다. 측정된 부하 데이터는 변동 하중이므로, 부하 크기와 빈도수의 규칙적인 신호로 단순화하기 위하여 레인플로우 카운팅 방법을 사용하였으며, SWT (Smith-Watson-Topper) 방법을 이용하여 공칭 토크를 계산하였다. PTO 기어의 안전율은 ISO 6336, 피로 수명은 마이너 법칙(Miner rule)을 이용하여 계산하였다. PTO의 변속 단수 총 2단이며, 5개의 스퍼 기어로 구성되어 있다. 시뮬레이션 결과, 소형 관리기의 주행 속도 또는 PTO의 회전속도 증가에 따라 PTO에서 발생하는 평균 부하가 크게 나타났다. 또한 주행 단수 및 PTO 기어 단수가 증가할수록 기어의 안전율과 피로 수명이 감소하였으며, 특히 PTO 기어의 안전율은 접촉 응력에서의 안전율보다 굽힘 응력에서의 안전율이 급격하게 감소하였다. 소형 관리기의 PTO 수명은 주행 단수 2단, PTO 단수 2단 일 때 가장 적게 나타났다. 따라서 소형 관리기의 주행 속도와 PTO 회전 속도를 저속으로 작업하는 것이 PTO 기어의 수명에 더 유리할 것으로 판단된다.
Proceedings of the Korea Water Resources Association Conference
/
2007.05a
/
pp.2069-2073
/
2007
효과적인 저수지 수질관리 대책을 수립하기 위해서는 상류 유역으로부터 오염원의 유출특성에 대한 정확한 이해가 필요하다. 강우시 대부분 유입하는 비점오염원은 실측에 많은 비용과 시간이 소요되어 부하량 산정에 어려움이 있어 전체 부하량에서 차지하는 기여도를 파악하는데 어려움이 있었다. 본 연구의 목적은 Digital Filter 기법을 이용하여 댐 유입량 수문곡선으로부터 유출성분을 분리하고, 강우시 유출하는 비점오염부하량을 산정하는 방법을 개발하는데 있다. 연구대상지역은 대청호를 선택하였다. 유출성분별 오염부하량을 정량화하기 위해 댐 유입량을 각각 지표유출, 중간유출 및 기저유출 성분으로 분리하고, 강우시 지표유출과 중간유출을 합하여 비점오염원 부하량(직접유출)으로 산정하였다. 유출성분별 일별 부하량은 실측된 유량 및 수질자료로부터 유도된 유량-부하량의 상관관계식을 적용하였다. 연구결과 대청호 유입량의 유출성분비는 각각 지표유출 49.2%, 중간유출 25.5% 및 기저유출 25.4%로 산정되었다. 2001년 옥천지점에서 유출성분분리 결과, 총 유출량 중 기저유출, 지표유출, 중간유출의 비가 각각 35.1%, 39.5%, 25.5%로 산정되었고, 청성지점은 각각 39.7%, 36.1%, 24.2%로 나타났다. $2001{\sim}2005$년까지 유출 성분별 비점오염원 부하량을 산정한 결과, 대청호에 비점오염원 부하량 기여율의 범위(평균값)는 각각 BOD $65.2{\sim}88.0%$(평균 83.5%), COD $68.1{\sim}$ 89.3%(평균 86.8%), T-N $60.4{\sim}88.6%$(평균 84.2%), 그리고 T-P $77.7{\sim}96.6%$(평균 94.3%)로 산정되었다. 이러한 결과는 대청호로 유입하는 유기물과 영양염류 연간 부하량의 80% 이상이 강우-유출과 함께 유입하는 것을 의미하며, 저수지 수질관리를 위해서는 유역차원의 비점오염원 관리가 시급함을 시사한다.
Attempts were made to find out nitrogen and phosphorus loads to aquatic environment resulting from feeding Nile tilapia (Oreochromis niloticus). Two different size groups, small and large, were used. The average sizes of small and large tilapia were 65.2 g and 389.2 g respectively, and three kinds of commercial diets were used for each size. The 3 kinds of commercial diets for tilapia contained in average 33.8% crude protein ($5.4\%$ nitrogen) and $1.4\%$ total phosphorus. The load of nitrogen and phosphorus were measured by subtracting the amounts of nutrients retained in the body of fish from consumed nutrients. Sixty, five percentage of total feces was excreted within 24 hours after feeding at $23^{\circ}C$. Nitrogen content in the feces was higher in large fish than small ones. The apparent digestibility of dietary protein for small and large tilapia was $90.0\%$ and $89.7\%$, respectively. Availability of dietary phosphorus for small and large tilapia was $44.7\%\;and\;51.4\%$, respectively. The total load of nitrogen and phosphorus per 1 metric ton of tilapia production was 49.5kg and 6.3kg, respectively, for small ones with feed conversion ratio (FCR) of 1.4, and 61.3 kg and 13.4kg, respectively, for large ones with the FCR of 1.8. Nitorgen balance appeared that small and large tilapia excreted $7.1\%\;and\;9.9\%$ of consumed nitrogen through fecal-nitrogen and $55.5\%\;and\;62.3\%$ through urine and gills, retaining $37.4\%\;and\;27.8\%$ in the body, respectively. These results show that small fish pollute less than large fish, excreting less and retaining more nutrients in the body.
Park, Woon Ji;Lee, Hae Seung;Hwang, Soon Hong;Lee, Young Joon;Choi, Joong Dae
Proceedings of the Korea Water Resources Association Conference
/
2015.05a
/
pp.401-401
/
2015
본 연구에서는 기타재배지(벚나무재배지)에서 발생하는 비점오염물질 유출 및 수질특성을 살펴보고자 2014년 5월부터 9월까지의 총 12회의 강우사상에 대해 유출특성을 분석하고 오염물질별 유량가중평균농도(Event Mean Concentration, EMC) 및 오염부하를 산정하였다. 모니터링 기간동안 2.6~95.8 mm의 강우가 발생하였으며, 조사된 총 12회의 event 중 단 2회 유출이 발생하였다. 강우강도는 0.33~5.28 mm/hr의 범위로 나타났으며, 선행무강우일수는 0.6~21.2일, 총 유출량은 $0.92{\sim}20.75m^3$, 유출율은 0.03~0.18의 범위로 나타났다. 강우모니터링 결과, EMC는 TOC 3.4~10.3 mg/L(평균 6.9 mg/L), BOD 6.3~6.9 mg/L(평균 6.6 mg/L), COD 22.0~28.8 mg/L(평균 25.4 mg/L), SS 101.8~962.8 mg/L(평균 532.3 mg/L), T-N 4.295~11.864 mg/L(평균 8.080 mg/L) 그리고 T-P 1.109~1.582 mg/L(평균 1.346 mg/L)의 범위로 나타났으며, 각 강우사상에 대한 단위면적당 오염부하는 TOC 0.08~0.58 kg/ha, BOD5 0.05~1.07kg/ha, CODMn 0.22~3.76 kg/ha, SS 0.77~164.4 kg/ha, T-N 0.090~0.734 kg/ha, T-P 0.008~0.270 kg/ha의 범위로 산정되었다. 벚나무재배지의 수질 항목간 Pearson 상관계수를 분석한 결과, 항목 중 $COD_{Mn}$가 다른 수질항목과 유의성을 갖고 높은 상관관계가 나타나 초기유출효과 분석을 위한 대표 수질항목으로 선정하였다. 벚나무재배지의 경우 초기유출 발생에 의한 오염부하의 급격한 증가는 나타나지 않았으며, 누적오염부하량비의 그래프에서는 대부분의 강우사상에서 기울기가 직선에 가깝게 나타났다. 기타재배지의 경우 대부분 투수지역으로 초기세척효과가 비교적 작은 것으로 나타났으며, 지속적으로 오염물질을 배출하는 특성을 보이는 것으로 분석되었다.
To investigate a method for calculation of the heating load for environmental designs of horticultural facilities, measurements of total heating load, infiltration rate, and floor heat flux in a large-scale plastic greenhouse were analyzed comparatively with the calculation results. Effects of ground heat exchange and infiltration loss on the greenhouse heating load were examined. The ranges of the indoor and outdoor temperatures were $13.3{\pm}1.2^{\circ}C$ and $-9.4{\sim}+7.2^{\circ}C$ respectively during the experimental period. It was confirmed that the outdoor temperatures were valid in the range of the design temperatures for the greenhouse heating design in Korea. Average infiltration rate of the experimental greenhouse measured by a gas tracer method was $0.245h^{-1}$. Applying a constant ventilation heat transfer coefficient to the covering area of the greenhouse was found to have a methodological problem in the case of various sizes of greenhouses. Thus, it was considered that the method of using the volume and the infiltration rate of greenhouses was reasonable for the infiltration loss. Floor heat flux measured in the center of the greenhouse tended to increase toward negative slightly according to the differences between indoor and outdoor temperature. By contrast, floor heat flux measured at the side of the greenhouse tended to increase greatly into plus according to the temperature differences. Based on the measured results, a new calculation method for ground heat exchange was developed by adopting the concept of heat loss through the perimeter of greenhouses. The developed method coincided closely with the experimental result. Average transmission heat loss was shown to be directly proportional to the differences between indoor and outdoor temperature, but the average overall heat transfer coefficient tended to decrease. Thus, in calculating the transmission heat loss, the overall heat transfer coefficient must be selected based on design conditions. The overall heat transfer coefficient of the experimental greenhouse averaged $2.73W{\cdot}m^{-2}{\cdot}C^{-1}$, which represents a 60% heat savings rate compared with plastic greenhouses with a single covering. The total heating load included, transmission heat loss of 84.7~95.4%, infiltration loss of 4.4~9.5%, and ground heat exchange of -0.2~+6.3%. The transmission heat loss accounted for larger proportions in groups with low differences between indoor and outdoor temperature, whereas infiltration heat loss played the larger role in groups with high temperature differences. Ground heat exchange could either heighten or lessen the heating load, depending on the difference between indoor and outdoor temperature. Therefore, the selection of a reference temperature difference is important. Since infiltration loss takes on greater importance than ground heat exchange, measures for lessening the infiltration loss are required to conserve energy.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.