• Title/Summary/Keyword: 평가 기준장비

Search Result 441, Processing Time 0.029 seconds

Viability test and bulk harvest of natural zooplankton communities to verify the efficacy of a ship's ballast water treatment system based on USCG phase-II (USCG phase-II 선박평형수 처리장치 성능 평가를 위한 자연 해수의 동물플랑크톤 대량 확보 및 생사판별)

  • Jang, Min-Chul;Baek, Seung Ho;Shin, Kyoungsoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.9-15
    • /
    • 2016
  • We investigated >$50-{\mu}m$ marine planktonic organisms (mainly zooplankton) using a bongo net in Masan Bay and Jangmok Bay in order to harvest 75% of natural communities based on Phase-II approval regulations by the United States Coast Guard (USCG). The concentrated volume (in 1 ton) and abundance of zooplankton were $1.8{\times}10^7ind.ton^{-1}$ and $2.3{\times}10^7ind.ton^{-1}$, and their survival rates were 82.6% and 80.1%, respectively. The community structure in Jangmok Bay was similar to that in Masan Bay, and dominant species were adult and immature groups (stage IV) of genus Acartia. Harvested populations were inoculated in a 500-ton test tank. Although the population abundances were $6.0{\times}10^4ind.ton^{-1}$ for both bay samples, the mortality rates were higher in the Masan Bay population (32%) than the Jangmok Bay population (20%). We considered the reason to be that there were 30% more immature individuals of Acartia from Masan Bay than from Jangmok Bay. The younger population may have been greatly stressed by the moving process and netting gear. After applying a Ballast Water Treatment System (BWTS) using a sample form Jangmok Bay, the mortality rates in the treatment groups were found to be 100% after 0 days and 5 days, implying that the BWTS worked well. During the winter season, the zooplankton concentration method alone did not easily satisfy the approval standards of USCG Phase II (> $10{\times}10^4ind.ton^{-1}$ in the 500 ton tank). Increasing the netting frequency and additional fishing boats may be helpful in meeting the USCG Phase II biological criteria.

A Method to Calculate a Pass Rate of the ${\gamma}$-index Analysis in Tomotherapy Delivery Quality Assurance (DQA) (단층치료기를 이용한 방사선 치료의 환자별 정도관리 평가를 위한 감마인덱스의 정량화 방법)

  • Park, Dahl;Kim, Yong-Ho;Kim, Won-Taek;Kim, Dong-Won;Kim, Dong-Hyun;Jeon, Ho-Sang;Nam, Ji-Ho;Lim, Sang-Wook
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.340-347
    • /
    • 2010
  • DQA, a patient specific quality assurance in tomotherapy, is usually performed using an ion chamber and a film. The result of DQA is analysed with the treatment planning system called Tomo Planning Station (TomoPS). The two-dimensional dose distribution of film measurement is compared with the dose distribution calculated by TomoPS using the ${\gamma}$-index analysis. In ${\gamma}$-index analysis, the criteria such as 3%/3 mm is used and we verify that whether the rate of number of points which pass the criteria (pass rate) is within tolerance. TomoPS does not provide any quantitative information regarding the pass rate. In this work, a method to get the pass rate of the ${\gamma}$-index analysis was suggested and a software PassRT which calculates the pass rate was developed. The results of patient specific QA of the intensity modulated radiation therapy measured with I'mRT MatriXX (IBA Dosimetry, Germany) and DQA of tomotherapy measured with film were used to verify the proposed method. The pass rate was calculated using PassRT and compared with the pass rate calculated by OmniPro I'mRT (IBA Dosimetry, Germany). The average difference between the two pass rates was 0.00% for the MatriXX measurement. The standard deviation and the maximum difference were 0.02% and 0.02%, respectively. For the film measurement, average difference, standard deviation and maximum difference were 0.00%, 0.02% and 0.02%, respectively. For regions of interest smaller than $24.3{\times}16.6cm^2$ the proposed method can be used to calculate the pass rate of the gamma index analysis to one decimal place and will be helpful for the more accurate DQA in tomotherapy.

The Position for Measuring BMD of the Distal Radius and The Study of the Correlation Between the Distal Radius and Lumba (원위 요골 골밀도의 측정 자세 및 요추 골밀도의 상관관계에 관한 연구)

  • Han, Man-Seok;Jeon, Chul-Min;Kim, Jong-Jin;Seo, Seon-Youl;Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • The aim of this study was to evaluate the change of bone mineral density according to distal radius rotation and the correlations of the lowest BMD measured by DXA at the lumba versus distal radius. The eleven males were projected distal radius by DR X-ray and the measurement of BMD by DXA of the appropriate position of the forearm were performed on 21 males. The healthy 11 and 21 volunteers without any history of operations, anomalies, or trauma were enrolled. The experiment was performed by two methods. First, The DR X-ray was measured distal radius of 11 males in pronation and supination with three, six and nine degrees, including a neutral position. The ROI was measured by the m-view program on the PACS monitor. Second, The DXA was measured distal radius of 21 males in pronation and supination with five and ten degrees, including a neutral position to evaluate the changes of BMD according to the rotation. A correlation of the BMD in the distal radius with BMD that lumbar spine was performed, along with analysis of the data by SPSS 12.0v. The mean rotation angle of the distal radius about eleven males DR X-ray measured $7^{\circ}$ of pronation (82%, n = 9), $6^{\circ}$ of supination and $0^{\circ}$ of neutral of (9%, n = 1), The total average rotation angle in 11 male was $5.1^{\circ}$ of pronation. The rotation angle of the distal radius about twenty one males on DXA measured $7.2^{\circ}$ of pronation (43%, n = 9), $7^{\circ}$ of supination (24%, n = 5), and $0^{\circ}$ of neutral (33%, n = 7), The total average rotation angle in 21 people was $4.1^{\circ}$ of pronation. The correlation of the analysis of lumba and distal radius were r = 3.0, p = 0.18. consequently, The correlation was not significance. Because BMD of lumba was not coverd for BMD of the distal radius, with a neutral position, Pronation is needed for BMD in the distal radius with the rotation angle measuring at the lowest BMD. the rotation angle about five degrees of pronation of the distal radius is recommended.

Report on the External Audits Conducted by Korean Society of Medical Physics (한국의학물리학회 선형가속기 외부 품질관리 실시 현황보고)

  • Huh, Hyun Do;Cho, Kwang Hwan;Cho, Sam Ju;Choi, Sang Hyoun;Kim, Dong Wook;Hwang, Ui-Jung;Kim, Ki Hwan;Min, Chul Kee;Choi, Tae Jin;Oh, Young Kee;Lee, Seoung Jun;Park, Dahl;Park, Sung-Kwang;Ji, Young Hoon
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.315-322
    • /
    • 2013
  • The aim of this work is to verify the self-quality assurances in medical institutions in Korea through the external audits by the group of experts and have a mutual discussion of the systematic problems. In order to validate the external audits 30 of 80 medical institutions across the nation were picked out considering the regional distribution and the final 25 institutions applied voluntarily to take part in this work. The basic rules were setup that any information of the participants be kept secrete and the measurements be performed with the dosimetry system already verified through intercomparision. The outputs for 2 or more photon beams, the accuracy of gantry rotation and collimator rotation and the poistional accuracy of MLC movement were measured. The findings for the output measurement showed the differences of -0.8%~4.5%, -0.79%~3.01%, and -0.7%~0.07% with respect to that of the verified dosimetry system for the 6MV, 10MV, and 15MV, respectively. For the reference absorbed dose 8 (16%) of 50 photon beams in 25 medical institutions differed 2.0% or greater from the reference value. The coincidences of Field size with x-ray beam and radiation isocenters of Gantry roration and collimator rotation gave the results of within ${\pm}2$ mm for every institute except 2 institutions. The positional accuracy of MLC movement agreed to within ${\pm}1$ mm for every institute. For the beam qualities of 6 MV photon beams kQ values showed the distribution within 0.4% between maximum and minimum. For the protocols 21 institutions (84%) used absorbed dose to water based protocol while 4 insitutions (16%) used air kerma based one. 22 institutions employed the SSD technique while 3 institutions did the SAD one. External audit plays an important role in discovering the systematic problems of self-performing Quality Assurances and having in depth discussion for mutual complementation. Training experts of international level as well as national support system are required so that both the group of experts of medical physicists and government laboratory could perform together periodical and constant external audits.

CComparative evaluation of the methods of producing planar image results by using Q-Metrix method of SPECT/CT in Lung Perfusion Scan (Lung Perfusion scan에서 SPECT-CT의 Q-Metrix방법과 평면영상 결과 산출방법에 대한 비교평가)

  • Ha, Tae Hwan;Lim, Jung Jin;Do, Yong Ho;Cho, Sung Wook;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.90-97
    • /
    • 2018
  • Purpose The lung segment ratio which is obtained through quantitative analyses of lung perfusion scan images is calculated to evaluate the lung function pre and post surgery. In this Study, the planar image production methods by using Q-Metrix (GE Healthcare, USA) program capable of not only quantitative analysis but also computation of the segment ratio after having performed SPECT/CT are comparatively evaluated. Materials and Methods Lung perfusion scan and SPECT/CT were performed on 50 lung cancer patients prior to surgery who visited our hospital from May 1, 2015 to September 13, 2016 by using Discovery 670(GE Healthcare, USA) equipment. AP(Anterior Posterior)method that uses planar image divided the frontal and rear images into three rectangular portions by means of ROI tool while PO(Posterior Oblique)method computed the segment ratio by dividing the right lobe into three parts and the left lobe into two parts on the oblique image. Segment ratio was computed by setting the ROI and VOI in the CT image by using Q-Metrix program and statistically analysis was performed with SPSS Ver. 23. Results Regarding the correlation concordance rate of Q-Metrix and AP methods, RUL(Right upper lobe), RML(Right middle lobe) and RLL(Right lower lobe) were 0.224, 0.035 and 0.447. LUL(Left upper lobe) and LLL(Left lower lobe) were found to be 0.643 and 0.456, respectively. In the PO method, the right lobe were 0.663, 0.623 and 0.702, respectively, while the left lobe were 0.754 and 0.823. When comparison was made by using the Paired sample T-test, Right lobe were $11.6{\pm}4.5$, $26.9{\pm}6.2$ and $17.8{\pm}4.2$, respectively in the AP method. Left lobe were $28.4{\pm}4.8$ and $15.4{\pm}5.6$. The right lobe of PO had values of $17.4{\pm}5.0$, $10.5{\pm}3.6$ and $27.3{\pm}6.0$, while the left lobe had values of $21.6{\pm}4.8$ and $23.1{\pm}6.6$, thereby having statistically significant difference in comparison to the Q-Metrix method for each of the lobes (P<0.05). However, there was no statistically significant difference in Right middle lobe (P>0.05). Conclusion The AP method showed low concordance rate in correlation with the Q-Metrix method. However, PO method displayed high concordance rate overall. although AP method had significant differences in all lobes, there was no significant difference in Right middle lobe of PO method. Therefore, at the time of production of lung perfusion scan results, utilization of Q-Metrix method of SPECT/CT would be useful in computation of accurate resultant values. Moreover, it is deemed possible to expect obtain more practical sectional computation result values by using PO method at the time of planar image acquisition.

Evaluation of Reference Intervals of Some Selected Chemistry Parameters using Bootstrap Technique in Dogs (Bootstrap 기법을 이용한 개의 혈청검사 일부 항목의 참고범위 평가)

  • Kim, Eu-Tteum;Pak, Son-Il
    • Journal of Veterinary Clinics
    • /
    • v.24 no.4
    • /
    • pp.509-513
    • /
    • 2007
  • Parametric and nonparametric coupled with bootstrap simulation technique were used to reevaluate previously defined reference intervals of serum chemistry parameters. A population-based study was performed in 100 clinically healthy dogs that were retrieved from the medical records of Kangwon National University Animal Hospital during 2005-2006. Data were from 52 males and 48 females(1 to 8 years old, 2.2-5.8 kg of body weight). Chemistry parameters examined were blood urea nitrogen(BUN)(mg/dl), cholesterol(mg/dl), calcium(mg/dl), aspartate aminotransferase(AST)(U/L), alanine aminotransferase(ALT)(U/L), alkaline phosphatase(ALP)(U/L), and total protein(g/dl), and were measured by Ektachem DT 60 analyzer(Johnson & Johnson). All but calcium were highly skewed distributions. Outliers were commonly identified particularly in enzyme parameters, ranging 5-9% of the samples and the remaining were only 1-2%. Regardless of distribution type of each analyte, nonparametric methods showed better estimates for use in clinical chemistry compare to parametric methods. The mean and reference intervals estimated by nonparametric bootstrap methods of BUN, cholesterol, calcium, AST, ALT, ALP, and total protein were 14.7(7.0-24.2), 227.3(120.7-480.8), 10.9(8.1-12.5), 25.4(11.8-66.6), 25.5(11.7-68.9), 87.7(31.1-240.8), and 6.8(5.6-8.2), respectively. This study indicates that bootstrap methods could be a useful statistical method to establish population-based reference intervals of serum chemistry parameters, as it is often the case that many laboratory values do not confirm to a normal distribution. In addition, the results emphasize on the confidence intervals of the analytical parameters showing distribution-related variations.

Soil Contamination of Heavy Metals in National Industrial Complexes, Korea (국내 주요 국가산업단지에서 중금속에 의한 토양오염)

  • Jeong, Tae-Uk;Cho, Eun-Jeong;Jeong, Jae-Eun;Ji, Hwa-Seong;Lee, Kyeong-Sim;Yoo, Pyung-Jong;Kim, Gi-Gon;Choi, Ji-Yeon;Park, Jong-Hwan;Kim, Seong-Heon;Heo, Jong-Soo;Seo, Dong-Cheol
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.2
    • /
    • pp.69-76
    • /
    • 2015
  • BACKGROUND: Contamination of soils by heavy metals is the serious environmental problem. In particular, industrial processing is one of the main sources of heavy metal contamination. The objective of this study was to investigate the distribution characteristics of heavy metals in soils collected from industrial complex. METHODS AND RESULTS: In this study, the soil contamination and enrichment factor (EF) of heavy metals were investigated in three national industrial complexes such as Yeosu, Ulsan and Sihwa Banwal industrial complexes. The target heavy metals includes Cd, Cu, As, Hg, Pb, Cr, Zn, and Ni. The results showed that the contents of Cd, Hg, Pb, Zn and Ni in Yeosu and the contents of Cu, As and Cr in Sihwa Banwal were higher than in any other industrial complex. The results of principal component analysis(PCA) in Yeosu, Ulsan and Sihwa Banwal complex could be explained up to approximately 81.4, 69.1 and 70.9% by two factor, respectively. Enrichment factors of Cd, Pb and Zn in all the investigated industrial complexes were above 1.0 that was the value judged to be a high contamination. And EF of Cr was above 1.0 in Sihwa Banwal complex. EF of Zn in all sites was generally high from the other heavy metals. CONCLUSION: Therefore, soils maybe significantly affected by heavy metals (especially, Cd, Pb and Zn) present in the emissions from industrial complexes.

Improvement of analytical methods for arsenic in soil using ICP-AES (ICP-AES를 이용한 토양 시료 중 비소 분석 방법 개선)

  • Lee, Hong-gil;Kim, Ji In;Kim, Rog-young;Ko, Hyungwook;Kim, Tae Seung;Yoon, Jeong Ki
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.409-416
    • /
    • 2015
  • ICP-AES has been used in many laboratories due to the advantages of wide calibration range and multi-element analysis, but it may give erroneous results and suffer from spectral interference due to the large number of emission lines associated with each element. In this study, certified reference materials (CRMs) and field samples were analyzed by ICP-AES and HG-AAS according to the official Korean testing method for soil pollution to investigate analytical problems. The applicability of HG-ICP-AES was also tested as an alternative method. HG-AAS showed good accuracies (90.8~106.3%) in all CRMs, while ICP-AES deviated from the desired range in CRMs with low arsenic and high Fe/Al. The accuracy in CRM030 was estimated as below 39% at the wavelength of 193.696 nm by ICP-AES. Significant partial overlaps and sloping background interferences were observed near to 193.696 nm with the presence of 50 mg/L Fe and Al. Most CRMs were quantified with few or no interferences of Fe and Al at 188.980 nm. ICP-AES properly assessed low and high level arsenic for field samples, at 188.980 nm and 193.696 nm, respectively. The importance of the choice of measurement wavelengths corresponding to relative arsenic level should be noted. Because interferences were affected by the sample matrix, operation conditions and instrument figures, the analysts were required to consider spectral interferences and compare the analytical performance of the recommended wavelengths. HG-ICP-AES was evaluated as a suitable alternative method for ICP-AES due to improvement of the detection limit, wide calibration ranges, and reduced spectral interferences by HG.

The Study for Results of Complex Cystic Breast Masses by Biopsy on Ultrasound (초음파상 복합성 낭성 유방 종괴의 조직 검사 결과에 관한 연구)

  • Kang, Hye-Kyoung;Dong, Kyung-Rae
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.129-134
    • /
    • 2008
  • Purpose: We examined the roles of Ultrasonography conductors by analyzing the results of tissue biopsy of complex cystic masse under the guidance of breast US. Objects and methods: This study was performed to a group of 178 who showed breast US indicating complex cystic masses among 342 patients who were definitely diagnosed by tissue biopsies and operations in our hospital from June 30th, 2003 to June 30th, 2007. The evaluation of tissues around, calcification, the distribution state of blood flow were excluded from the analysis subjects and logic 200 made by GE corporation and gun for core biopsy(Kimal corp., K7/MBD23) were used in this study. Results: The biopsy results of 178 subjects showed FCC (fibrocystic change)(n=56 : 31.4%), Fibrosis (n=41 : 23.0%), Fibroadenoma (n=20 : 11.2%), Epithelial hyperplasia (n=17 : 9.6%), Carcinoma (n=15 : 8.4%), Fibroadipose (n=8 : 4.5%), Sclerosing adenosis (n=7 : 3.9%), Duct ectasia (n=5 : 2.8%), Papiloma (n=5 : 2.8%), and Fat necrosis (n=1 : 0.6%), Hemangioma (n=1 : 0.6%), Abscess (n=1 : 0.6%), Dystrophic calcification(n=1 : 0.6%). Conclusion: The US showed that the results of the tissue biopsy of complex cystic masses were mostly carcinoma(8.4%). Most of them were benign and only 9.6% of epithelial hyperplasia which has high progression rate into malignant tumors epidemically showed malignancy. Most of them were included in the spectrum of fibrous cystic nodule. Even though these results are confirmed, further studies are required. As a result, a nodule which is not certified by US should be right to take the tissue biopsy, but if it's difficult due to patients or another reasons, re-check tests in three months are required. And systemic ultrasonography evaluation should be well recognized to conduct more careful and specific tests.

  • PDF

Determining Ion Collection Efficiency in a Liquid Ionization Chamber in Co-60 Beam (Co-60 빔에서 액체 전리함의 이온 수집 효율 결정 연구)

  • Choi, Sang Hyoun;Kim, Chan Hyeong
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.46-52
    • /
    • 2014
  • Liquid ionization chamber is filled with liquid equivalent material unlike air filled ionization chamber. The high density material allow very small-volume chamber to be constructed that still have a sufficiently high sensitivity. However liquid ionization chamber should be considered for both initial recombination and general recombination. We, therefore, studied using the Co-60 beam as the continuous beam and the microLion chamber (PTW) for comparing the ion collection efficiency by Greening theory, two-dose rate method and our experiment method. The measurements were carried out using Theratron 780 as the cobalt machine and water phantom and 0.6 cc Farmer type ionization chamber was used with microLion chamber in same condition for measuring the charge of microLion chamber according to the dose rates. Dose rate was in 0.125~0.746 Gy/min and voltages applied to the microLion chamber were +400, +600 and +800 V. As the result, the collection efficiency by three method was generally less than 1%. In particular, our experimental collection efficiency was in good agreement within 0.3% with Greening theory except the lowest two dose rates. The collection efficiency by two-dose rate method also agreed with Greening theory generally less than 1%, but the difference was about 4% when the difference of two dose rates were lower. The ion recombination correction factors by Greening theory, two-dose rate method and our experiment were 1.0233, 1.0239 and 1.0316, respectively, in SSD 80 cm, depth 5 cm recommended by TRS-398 protocol. Therefore we confirmed that the loss by ion recombination was about 3% in this condition. We think that our experiment method for ion recombination correction will be useful tool for radiation dosimetry in continuous beam.