• Title/Summary/Keyword: 평가 기준장비

Search Result 441, Processing Time 0.036 seconds

A study on the Pressure Test of the Glass Window for High Speed Train (고속철도차량용 창문유리의 압력시험에 관한 연구)

  • Chang, Dae-Sung;Yi, Won
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.5
    • /
    • pp.391-397
    • /
    • 2011
  • In this paper, the pressure endurance test of passenger train's glass window which was developed for next high speed train was studied. At first, pressure test equipment which will be able to generate the maximum pressure same as crossing case between two trainsets in the tunnel was developed. Afterwards the pressure test and evaluation that are based on NFF31-314 were carried out and studied.

Evaluation of X-ray System for Nondestructive Testing on Radioactive Waste Drums (방사성폐기물 드럼 비파괴 검사를 위한 X-ray 장비 평가)

  • Park, Jong-Kil;Maeng, Seong-Jun;Lee, Yeon-Ee;Hwang, Tae-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.3
    • /
    • pp.189-203
    • /
    • 2008
  • The physical and chemical properties of radioactive waste drums, which have been temporarily stored on site, should be characterized before their shipment to a disposal facility in order to prove that the properties meet the acceptance guideline. The investigation of NDT(Nondestructive Test) method was figured out that the contents in drum, the quantitative analysis of free standing water and void fraction can be examined with X-ray NDT techniques. This paper describes the characteristics of X-ray NDT such as its principles, the considerations for selection of X-ray system, etc. And then, the waste drum characteristics such as drum type and dimension, contents in drum, etc. were examined, which are necessary to estimate the optimal X-ray energy for NDT of a drum. The estimation results were that: $(R)\acute{A}$ the proper X-ray energy is under 3 MeV to test the drums of 320 ${\beta}\S$ and less; $(R)\ddot{E}$ both X-ray systems of 450 keV and/or 3 MeV might be needed considering the economical efficiency and the realization. The number of drums that can be tested with 450 keV and 3 MeV X-ray system was figured out as 42,327 and 18,105 drums (based on storage of 2006. 12), respectively. Four testing scenarios were derived considering equipment procurement method, outsourcing or not, etc. The economical and feasibility assessment for the scenarios was resulted in that an optimal scenario is dependent on the acceptance guide line, the waste generator's policy on the waste treatment and the delivery to a disposal facility, etc. For example, it might be desirable that a waste generator purchases two 450 keV mobile system to examine the drums containing low density waste, and that outsourcing examination for the high density drums, if all NDT items such as quantitative analysis for 'free standing water' and 'void fraction', and confirmation of contents in drum have to be characterized. However, one 450 keV mobile system seems to be required to test only the contents in 13,000 drums per year.

  • PDF

Evaluation of Streamflow Data of MOCT (2004년 건설교통부 유량자료의 평가)

  • Jung, Sung-Won;Han, Myung-Sun;Hwang, Seok-Hwan;Kim, Chi-Young;Lee, Chan-Ju;Kim, Dong-Gu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1343-1347
    • /
    • 2006
  • 부정확한 유량자료는 예산 부족, 전담인력의 부재, 전문장비의 미비 등 구조적 측면에 근본적인 원인이 있는 것으로 판단되나, 유량측정 단계의 부정확과 유량자료의 처리절차가 실제적으로 이루어지지 않는 등 기술적 측면에도 중요한 한 원인이 있다. 건설교통부에서는 수문조사 선진화 5개년 계획의 일환으로 구조적.기술적인 문제를 개선하기 위해 2004년도 건설교통부 유량측정사업에서 유량측정 검증시스템을 도입하여 운영한 바 있다. 유량측정 검증시스템은 유량 측정과 분석을 나누어 수행하는 것으로, 강화된 기준과 방법론에 따라 정밀한 유량측정은 용역사에서 담당하였으며, 측정기준 강화, 측정방법 개선, 일상 검증과정 도입, 곡선식 개발 방법론 개선 및 유량환산/평가 절차 추가 등 분석과정은 한국건설기술연구원에서 수행하였다. 새로이 적용한 유량측정 검증시스템의 적용을 통해 생성된 2004년도 건설교통부 유량자료는 불확실도가 전국 평균 6.5%로 개선되었으며, 63개 지점 중에서 35개 지점(56%)에서 연유출률이 비교적 정상적인 수치를 보여 과거에 비해 상당히 개선된 품질수준을 보이는 것으로 나타났다.

  • PDF

River Discharge Measurement and Analysis for Nakdong-River Basin in 2007 (2007년 낙동강 유량측정 및 유출특성 분석)

  • Kim, Hyeong-Seop;Kim, Sam-Eun;Lee, Gi-Seong;Jeong, Chan-Yong;Song, In-Ryeol;Im, Hyeok-Jin;Min, Gyeong-Hun;Jeong, Yeong-Hun;Hwang, Su-Jin;Lee, Jeong-Seok;Lee, Gang-Il
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.2264-2269
    • /
    • 2008
  • 귀중한 수자원을 효율적으로 관리하고 홍수 피해를 저감하고 환경친화적인 수자원의 역할을 제대로 자리매김하기 위하여 무엇보다 필요한 사항은 신뢰성 있는 유량자료를 기초자료로서 확보하는 것이다. 그러나 유량 측정에 필요한 측정기준의 불명확, 예산과 측정장비의 부족, 전문 인력의 부재로 인해 그동안 유량자료에 대한 문제 제기가 계속되어 온 것이 사실이다. 최근 유량조사사업단의 설립과 함께 정도 높은 유량자료를 생성하고자 유량측정을 전문적으로 담당하는 인력이 유량측정과 분석을 일상적으로 수행하는 등 개선의 노력을 계속하고 있다. 강화된 유량측정 기준과 개선된 방법론에 따른 현장측정을 통해 정밀한 유량측정성과를 확보하였으며, 측정된 유량측정성과의 일상 검증을 통해 보다 정밀한 유량측정성과를 확보하고자 하였다. 또한 유량자료를 생성하여 이를 평가함으로써 유량측정 전 과정이 적절하게 이루어졌는지를 평가하고자 하였다. 그 결과, 낙동강 수계 본류의 주요 9개 대상 지점에 대해 신뢰성 있는 수위-유량관계곡선을 개발할 수 있었다. 개발된 곡선식을 이용하여 유량자료를 생성하고 상 하류간 비교, 유출률 분석 등을 통해 생성된 유량자료를 검토하였다. 확정된 유량자료는 양질의 수준을 갖는 것으로 평가되었다.

  • PDF

Experiments on Flexural Resistance of Longitudinally Stiffened Plate Girder with Slender Web (수평보강재로 보강된 세장복부판을 갖는 플레이트거더의 휨강도 평가 실험)

  • Park, Yong Myung;Lee, Kun Joon;Ju, Ho Jung;Jo, Sung Hoon
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.6
    • /
    • pp.595-604
    • /
    • 2014
  • In this paper, a series of experiments for the evaluation of flexural resistance of longitudinally stiffened plate girder with slender web were conducted. For the purpose, four plate girder specimens with and without longitudinal stiffener were fabricated for the web slenderness of 219 and 156. The test results were compared with the current AASHTO LRFD and Eurocode 3 codes, respectively. As presented in the previous paper by the authors, it was acknowledged that the AASHTO LRFD code could considerably underestimate the flexural resistance of longitudinally stiffened girder with slender web and the proposed method in the previous paper could estimate the flexural resistance reasonably.

Practical Application of Image Stage Gauge (영상수위계 실용화)

  • Kim, Won;Kim, Chi-Young;Lee, Chan-Joo;Kim, Dong-Gu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.560-564
    • /
    • 2007
  • 하천 수위 측정을 위해서 우물통을 기본으로 하는 부자식, 초음파식, 기포식, 압력식, 레이다식 등 다양한 장비가 사용되고 있다. 이와 같은 장비는 모두 간접적인 방법으로 수위를 측정하기 때문에 기준값을 바탕으로 보정이 필요하며, 장비의 특성에 따라 여러 가지 장단점을 지니고 있다. 부자식의 경우 오래 전부터 사용되어 안정적으로 수위를 측정할 수 있는 것으로 평가되고는 있으나 우물통 막힘 등으로 인해 오측 혹은 결측이 발생하는 경우가 있다. 최근에 많이 사용되고 있는 센서식 장비의 경우에는 센서에 대한 정기적인 보정이 필요하며, 일부 장비의 경우 온도에 따라 측정값이 변화하는 단점이 있다. 수위 측정 방식은 접촉식과 비접촉식으로 나누어 볼 수 있다. 접촉식의 경우 물속에 센서가 위치하고 있기 때문에 홍수시 센서 유실 및 고장의 우려가 있으며, 잦은 고장의 원인이 되기도 한다. 비접촉 방식인 초음파나 레이다 수위계의 경우 온도에 따라 보정이 필요하거나 수면과의 거리에 커지면 오차가 커지는 경향을 지니고 있다. 또한 이와 같은 간접방식에 의한 수위측정 방법은 수위가 많이 변화하는 경우 실제 수위와 측정되는 수위가 일치하는지를 확인하는 것이 불가능한 단점도 있다. 본 연구에서는 최근에 많이 일반화되고 있는 영상처리 기술을 이용하여 자동적으로 수위를 측정하는 장비인 영상수위계를 개발하였다. 영상수위계는 카메라(CCTV 포함)에 의해서 수위표를 촬영하여 직접 수위값으로 변환하는 원리를 사용하고 있어서 기존 수위측정 시설과는 달리 수위표를 직접 눈으로 확인할 수 있는 장점이 있다. 이로 인해 수위표를 육안으로 확인할 수 있기 때문에 측정된 수위를 검증할 수 있어 수위측정의 정확성을 한층 높일 수 있다. 그리고 수위표 영상과 더불어 수위표 주변의 전체 영상을 동시에 촬영하여 실시간으로 전송하기 때문에 홍수시 하천 상황에 대한 모니터링 목적으로 사용될 수 있다. 본 연구에서 개발한 영상수위계는 한강홍수통제소 관할의 전류, 청담대교 등 4개소 낙동강 홍수통제소 2개소, 지자체 등에 적용되었으며, 적용 결과 비교적 안정적이면서 정확하게 수위를 측정하는 것으로 나타났다. 한편 기존 CCD 카메라 이외에 CCTV를 이용한 영상수위계를 개발하여 영상의 화질 개선뿐 아니라 하천화상 감시 기능을 강화하였다.

  • PDF

Impedance design of tap changing auto transformer based LVRT/HVRT test device (탭 변환 단권변압기 기반 LVRT/HVRT 시험장비의 임피던스 설계)

  • Baek, Seung-Hyuk;Kim, Dong-Uk;Yoon, Young-Doo;Kim, Sungmin
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.216-224
    • /
    • 2020
  • This paper proposes an impedance design method of the test device for evaluating Low Voltage Ride Through(LVRT) and High Voltage Ride Through(HVRT) functions. The LVRT/HVRT test device should have ability to generate the fault voltage specified in the grid code for a certain period and to limit the magnitude of the fault current with the design specification. In this paper, the impedance design method for auto transformer is proposed based on a equivalent model of a tap-change auto-transformer during LVRT/HVRT operation. In addition, to generate various fault voltages required the LVRT/HVRT test, tap impedance design in the auto transformer is considered. To verify the validity of the proposed design method, the design process of the 10MVA LVRT/HVRT test device was conducted and the design results was verified through simulation models.

TMP 1000L/s 급 database 구축 및 종합특성평가시스템 진단 기술 개발

  • Gang, Sang-Baek;Sin, Jin-Hyeon;Cha, Deok-Jun;Jeong, Wan-Seop;Im, Jong-Yeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.335-335
    • /
    • 2010
  • 한국표준과학연구원 진공센터에서는 국제규격에 바탕을 둔 저진공펌프 종합특성평가시스템을 구축하여 $1100mbar\;{\sim}\;10^{-3}mbar$ 압력 영역에서의 저진공펌프(roots, dry 등)류의 종합특성평가를 시행하고 있다. 저진공펌프 종합특성평가시스템은 국제적 절차에 따른 신뢰성을 바탕으로 구축하고 있으나, 한국표준과학연구원 진공센터 뿐만 아니라, 국내에서도 고진공 종합특성평가 시스템을 구축 하고 있지 않다. 이에 반도체/디스플레이 등 첨단 공정에서 진공 환경을 조성하는 핵심장비인 고진공펌프의 종합특성평가시스템을 개발하고자 터보펌프(TMP) 1000L/s 급의 database를 구축 하였다. 터보펌프(TMP)는 throughput method와 orifice method 두 가지 방법을 병행하여 pumping speed 측정한다. orifice method는 일종의 미세유량 측정 장치이며, 실험값과 계산값 유량의 오차 범위가 작고 신뢰성을 확보하면 throughput method 만으로 측정할 수 있다. Througput method는 $10^{-6}mbar$ 압력 이상의 영역을 측정하며, ultimate pressure 및 $150^{\circ}C$의 bake-out 을 진행하여 base pressure을 측정 할 수 있으며, $10^{-6}mbar$ 압력 이상의 pumping speed를 측정 할 수 있다. 이에 따른 정압형 유량시스템을 개발 중에 있으며, inlet pressure와 outlet pressure를 이용한 compression ratio를 측정 한다. Orifice method는 ultimate pressure와 base pressure을 측정하며, leak valve를 이용한 컨덕턴스(C)로 pressure ratio을 이용하여 유량값을 계산하며, $10^{-6}mbar$ 압력 이하의 pumping speed를 측정할 수 있다. 또한 throughput method와 orifice method의 pumping speed 뿐만 아니라 소비전력 및 소음, 진동, 온도 등 특성평가 관련 사항들의 전반적인 사항을 평가하여 터보펌프(TMP) 1000L/s 급의 database를 구축한다. 향후 예비 실험을 통한 고진공펌프의 종합특성평가시스템을 완비해 나가며, 고진공펌프 종합 특성평가시스템을 통하여 국제적으로 공인받을 수 있는 평가기준을 확립하고 그 기준에 의한 진공/기계적 성능의 전방위적인 종합특성진단과 공정대응성 평가 등 국제적 기술 신뢰성을 확보하고자 한다.

  • PDF

An Evaluation Model for the Major Science Research Facilities and Equipments to Enhance the Competitiveness of the Science and Technology: A Focus on the Test of Reliability and Validity of the Model (과학기술 경쟁력 제고를 위한 대형연구시설 및 장비 평가모형 분석 : 모형의 신뢰성 및 타당성 검토를 중심으로)

  • Kwon, Gi-Heon;Cha, Yong-Jin;Lee, Hong-Jae
    • Journal of Korea Technology Innovation Society
    • /
    • v.10 no.1
    • /
    • pp.121-142
    • /
    • 2007
  • The purpose of this study is to construct the evaluation model for the major science research facilities and equipments to enhance the competitiveness of the science and technology and also to test the reliability and validity of the model. To achieve the purposes, this study theoretically reviews the concept of the major science research facilities and equipments and their characteristics. Through a review of literature, this study draws 11 criteria for evaluating the priorities of the major science research facilities and equipments. These criteria are categorized as two dimensions - 'science & technology' and 'national policy'. The dimension of science & technology includes scientific importance, technological readiness, utilization rate, common utilization rate, and ability of management and operation. The national policy dimension contains degree of correspondence with national science development, imperativeness of national policy, science and technical effectiveness, economic and industrial effectiveness, responsiveness of research demand, and equity among the related institutions. The competitiveness of the science and technology consists of these two dimensions. The evaluation model is established on the framework of criteria. The 18 major science research facilities and equipments are selected through a series of Delphi. The survey of experts (BT, ET, IT, NT and ST) is also implemented to evaluate the 18 major science research facilities and equipments by 11 criteria. The overall results indicate that the reliability and validity of the model are good. The reliability tests show that the five indicators of science & technology and the six indicators of national policy have high internal consistencies. The confirmatory factor analyses reveal that the two constructs - 'science & technology' and 'national policy' - have high convergent and discriminant validity. The correlational analyses also show that the criteria-related validity between them is high. Furthermore, the results of higher order factor analysis indicate that the fit indices of the model are high and suggest a good fit to the data. Based on these findings, the policy implications of the model are discussed.

  • PDF

Detecting of Proximal Caries in Primary Molars using Pen-type QLF Device (펜-타입 QLF 장비의 임상적 유구치 인접면 우식 탐지 성능)

  • Cho, Hyejin;Kim, Hyuntae;Song, Ji-Soo;Shin, Teo Jeon;Kim, Jung-Wook;Jang, Ki-Taeg;Kim, Young-Jae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.4
    • /
    • pp.405-413
    • /
    • 2021
  • The purpose of this in vivo study was to assess the clinical screening performance of a quantitative light-induced fluorescence (QLF) device in detecting proximal caries in primary molars. Fluorescence loss, red autofluorescence and a simplified QLF score for proximal caries (QS-proximal) were evaluated for their validity in detecting proximal caries in primary molars compared to bitewing radiography. Three hundred and forty-four primary molar surfaces were included in the study. Carious lesions were scored according to lesion severity assessed by visual-tactile and radiographic examinations. The QLF images were analyzed for two quantitative parameters, fluorescence loss and red autofluorescence, as well as for QS-proximal. For both quantitative parameters and QS-proximal, the sensitivity, specificity and area under receiver operating curve (AUROC) were calculated as a function of the radiographic scoring index at enamel and dentin caries levels. Both quantitative parameters showed fair AUROC values for detecting dentine level caries (△F = 0.794, △R = 0.750). QS-proximal showed higher AUROC values (0.757 - 0.769) than that of visual-tactile scores (0.653) in detecting dentine level caries. The QLF device showed fair screening performance in detecting proximal caries in primary molars compared to bitewing radiography.