• Title/Summary/Keyword: 평가 기준도

Search Result 13,655, Processing Time 0.045 seconds

Study on the Development and Properties of Ceramics Restoration Purpose Urethane resin with Excellent Reversibility (가역성이 우수한 도자기 복원용 Urethane resin의 개발 및 물성에 대한 연구)

  • Oh, Seung Jun;Park, Gi Jung;Wi, Koang Chul
    • Journal of Conservation Science
    • /
    • v.31 no.1
    • /
    • pp.37-46
    • /
    • 2015
  • In the case of adhesives & restoration agents currently being used for the preservation treatment of ceramics and earthenware, epoxy type, cellulose type and cellulose type are mainly being used. However, they are showing various problems such as re-detachment from severe contraction, color change from yellowing, work inconvenience of staining on tools and hand during usage and irreversibility. For the purpose of solving the issues of yellowing and irreversibility of epoxy resin being used to restore ceramics, urethane synthetic resin with low yellowing excellent reversibility has been developed in this study. The adhesive strength of urethane resin that has been developed has excellent properties with 2.07MPa for undiluted solution, which is 1.5 times higher than that of existing material EPO-$TEK301^{(R)}$ 1.21MPa. The result of workability measurement showed that the wear rate of urethane resin (in Talc 50wt%) was 1.09%, which was somewhat higher than that of existing material Quick $Wood^{(R)}$ (1.02%). In addition, its wear rate is two times higher than that of $EPO-TEK301^{(R)}$ (0.41%) and $L30^{(R)}$ (0.39%), thereby showing an advantage in its forming process compared to existing materials. As for the advantage of urethane resin of reversibility experiment, 12 hours after acetone, ethyl alcohol deposition, urethane resin and filler talc were dissolved 100% while showing powdering phenomenon. Compared to 0% reversibility of existing epoxy resin, it has much superior reversibility. The result of UV rays experiment to evaluate its durability showed that ${\Delta}E^*ab$ color change value based on undiluted solution of urethane resin was 2.76 before & after UV rays exposure, which was a decrease by about 7-20 times compared to that of existing resin, thereby minimizing the issue of heterogeneity.

Clinical Outcomes After Arthroscopic Double-Row Rotator Cuff Repair and Evaluation of Cuff Integrity by CT Arthrography (관절경적 2열 고정 회전근개 복원술 후의 임상 결과 및 CT 관절조영술을 이용한 건의 치유 평가)

  • Jo, Chris H.;Kim, Je-Kyoon;Yoon, Kang-Sup;Lee, Ji-Ho;Kang, Seung-Baek;Lee, Jae-Hyup;Han, Hyuk-Soo;Rhee, Seung-Whan
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.199-206
    • /
    • 2009
  • Purpose: Our goal for this study was to prospectively evaluate the functional & structural outcomes, by means of CT arthroscopy, of arthroscopic double-row fixation for treating rotator cuff tear. We also attempted to determine the variants that affect the functional & structural outcomes. Materials and Methods: Twenty seven consecutive patients underwent arthroscopic rotator cuff repair with double-row fixation. The average age at the time of the operation was fifty six years. The preoperative and postoperative examinations consisted of determining the Constant score, the score for the visual analogue scale for pain, the UCLA score, the American Shoulder and Elbow Surgeons (ASES) score, as well as a full physical examination of the shoulder. Preoperative MR arthrography was used to evaluate the integrity and atrophy of the rotator cuff. We measured the intraoperative tear size in the sagittal and coronal planes. Postoperative CT arthrography was used at one year postoperatively to evaluate the integrity and atrophy of the repaired tendons and muscles. Results: Preoperative MR arthrography revealed an average 29.22 mm tear size in the sagittal plane and an average 22.72 mm tear size in the coronal plane. Twelve cases of supraspinatus muscle atrophy and two cases of infraspinatus atrophy were observed on the preoperative MR arthrography. The average clinical outcome scores all significantly improved at the time of follow-up. At a mean of one year postoperatively, CT arthrography revealed 48.1% of the shoulders had healed, 11.1% showed incomplete healing and 40.7% showed retear of the repaired tendon. Conclusion: Arthroscopic double-row repair can result in improved clinical outcomes and good patient satisfaction. However, the problems about how to enhance healing of the repaired tendon still remain.

Effects of Different Nitrogen Levels and Planting Densities on the Quality and Yield of the Black Rice Cultivar 'Shinnongheugchal' (재식밀도 및 시비량 차이가 신농흑찰 품질 및 수량에 미치는 영향)

  • Lee, In-Sok;Lee, Deok-Ryeol;Cho, Seung-Hyun;Lee, Song-Yi;Kim, Kab-Cheol;Lee, Ki-Kwon;Song, Young-Ju
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.61 no.2
    • /
    • pp.79-86
    • /
    • 2016
  • The late-maturing black rice cultivar Shinnongheugchal from Jeollabuk-do Agricultural Research and Extension Service was used as the plant material for estimating growth characters, quality and yield from the vegetation period to harvest age. This study was performed to select an optimum combination of nitrogen level and planting density for the maximum yield of Shinnongheugchal. The plant height, number of tillers, and SPAD index were higher when the combination of 70 hills per $3.3m^2$ and 13 kg/10 a nitrogen level was used at 30 days after transplanting. The heading date for the combination of 70 hills per $3.3m^2$ and 15 kg/10 a nitrogen level, and 80 hills per $3.3m^2$ and 15 kg/10 a nitrogen level was August 22. The heading date for the other combinations was August 21. The combination of 70 hills per $3.3m^2$ and 13 kg/10 a nitrogen level yielded the highest number of tillers at 40 days after flowering. Even though the lodging index was increased with increasing nitrogen levels, field lodging did not occur until harvest time. Seed nitrogen concentration in the combination of 70 hills per $3.3m^2$ and 13 kg/10 a nitrogen level showed a significant difference when compared with the other combinations. The black rice yield varied significantly, and the highest yield was observed in the combination of 70 hills per $3.3m^2$ and 13 kg/10 a nitrogen level. The yield was significantly correlated with seed nitrogen concentration. The maximum yield was estimated to be 14.67 kg/10 a nitrogen level by using the regression equation. On average, the coloring degree of the black rice was higher at planting density of 70 hills per $3.3m^2$ than at 80 hills per $3.3m^2$. The highest yield of perfect black rice was obtained using the combination of 70 hills per $3.3m^2$ and 13 kg/10 a nitrogen level. Our findings demonstrate that a nitrogen level of 13-14 kg/10 a can be used to obtain the maximum yield from Shinnongheugchal with yield, cyanidin 3-glucoside content, and perfect black rice yield as the standard.

Quantitative Descriptive Analysis and Principal Component Analysis for Sensory Attributes of Commercial Milk Preserved at Different Temperature (보존온도를 달리한 상업적 우유제품의 묘사적 관능분석 및 PCA 분석)

  • Chung, Seo-Jin;Noh, Bong-Soo;Ju, Jong-Cheol;Lee, Min-Hyang;Park, Seung-Yong
    • Journal of Dairy Science and Biotechnology
    • /
    • v.29 no.2
    • /
    • pp.25-35
    • /
    • 2011
  • The objectives of this study were to evaluate the sensory characteristic quality of commercial milk brands selling in the market under the preservation at the temperature of $7^{\circ}C$ and $10^{\circ}C$ stored during the period of shelf-life. Quantitative descriptive analysis after developing of descriptive terms and cluster characterization by PCA analysis over a total of 128 LTLT, HTST, UHT and UHT-ESL milks, were conducted by 8 trained panelists. A total of fourteen attributes; three aroma attributes (grassy, milky, cultured milk aroma) and seven flavor/taste attributes (sweet, salty, sour, milk, cooked, cheesy, paper board) and one aftertaste attributes (rancid flavor) and one texture attributes (viscous), were developed as descriptive terms. Significant differences (P<0.01) in the sensory attributes; sweet, milky, cheesy etc. in UHT milk and sour, cheesy, paper board, rancid etc. in UHT-ESL milk were also found between the two different temperatures within the shelf life, but both type of pasteurized milk samples (LTLT and HTST) showed significant differences (P<0.01) in the attributes, such as cultured milk aroma, salty, sour, cheesy, rancid in LTLT milk and grassy, milky, salty in HTST milk and difference (P<0.05) in cultured milk aroma for HTST milk. Therefore, from the viewpoint of not only hygienic quality but also sensory characteristics, it is required for the better acceptance of milk consumers to amendment on the regulation in relation to the preservation standard of pasteurized milk as well as UHT milk to lower than $7^{\circ}C$.

  • PDF

Study on the calibration phantom and metal artifacts using virtual monochromatic images from dual energy CT (듀얼 에너지 CT의 가상 단색 영상을 이용한 영상 교정 팬텀과 금속 인공음영에 관한 연구)

  • Lee, Jun seong;Lee, Seung hoon;Park, Ju gyung;Lee, Sun young;Kim, Jin ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.77-84
    • /
    • 2017
  • Purpose: To evaluate the image quality improvement and dosimetric effects on virtual monochromatic images of a Dual Source-Dual Energy CT(DS-DECT) for radiotherapy planning. Materials and Methods: Dual energy(80/Sn 140 kVp) and single energy(120 kVp) scans were obtained with dual source CT scanner. Virtual monochromatic images were reconstructed at 40-140 keV for the catphan phantom study. The solid water-equivalent phantom for dosimetry performs an analytical calculation, which is implemented in TPS, of a 10 MV, $10{\times}10cm^2$ photon beam incident into the solid phantom with the existence of stainless steel. The dose profiles along the central axis at depths were discussed. The dosimetric consequences in computed treatment plans were evaluated based on polychromatic images at 120 kVp. Results: The magnitude of differences was large at lower monochromatic energy levels. The measurements at over 70 keV shows stable HU for polystyrene, acrylic. For CT to ED conversion curve, the shape of the curve at 120 kVp was close to that at 80 keV. 105 keV virtual monochromatic images were more successful than other energies at reducing streak artifacts, which some residual artifacts remained in the corrected image. The dose-calculation variations in radiotherapy treatment planning do not exceed ${\pm}0.7%$. Conclusion: Radiation doses with dual energy CT imaging can be lower than those with single energy CT imaging. The virtual monochromatic images were useful for the revision of CT number, which can be improved for target coverage and electron densities distribution.

  • PDF

Spring Phonology of a Grapevine Cultivar under the Changing Climate in Korea during 1921-2000 (겨울기온 상승에 따른 낙엽과수의 휴면생태 변화)

  • Jung Jea-Eun;Seo Hee-Cheol;Chung U-Ran;Yun Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.8 no.2
    • /
    • pp.116-124
    • /
    • 2006
  • Remarkable winter season warming has been observed in East Asian countries during the last century. Accordingly, significant effects on dormancy and the resulting budburst of deciduous trees are expected. However phenological observations are rare and insufficient compared with the long-time climate records in the same region. A chill-day accumulation, which can be estimated from daily maximum and minimum temperature, is expected to make a reasonable proxy for dormancy depth of temperate zone fruit trees. To simulate dormancy depth during 1921-2004, a chill-day model parameterized for 'Campbell Early' grapevine, which is the major cultivar grown virtually anywhere in South Korea, was applied to daily temperature data at 8 locations in South Korea. The calculations showed that the chilling requirement for breaking endo-dormancy of this grapevine cultivar can be satisfied by mid-January to late February in South Korea, and the date was delayed going either northward or southward from the 'Daegu-Jeonju' line crossing the middle of South Korea in the east-west direction. Maximum length of the cold tolerant period (the number of days between endo-dormancy release and forced dormancy release) showed the same spatial pattern. When we divide the 83 years into 3 periods (I: 1921-1950, II: 1951-1980, and III: 1981-2004) and get the average of each period, dormancy release date of period III was accelerated by as much as 15 days compared with that of period I at all locations except Jeju (located in the southernmost island with subtropical climate) where an average15-day delay was predicted. The cold- tolerant period was also shortened at 6 out of 8 locations. As a result, budburst of 'Campbell Early' in spring was accelerated by 6 to 10 days at most locations, while inter-annual variation in budburst dates was increased at all locations. The earlier budburst after the 1970s was due to (1) warming in winter resulting in earlier dormancy release (Incheon, Mokpo, Gangneung, and Jeonju), (2) warming in early spring accelerating regrowth after breaking dormancy (Busan and Jeju), and (3) both of them (Seoul and Daegu).

Ultrasound Measurement of Coracohumeral Distance in Patients with or without Subcoracoid Impingement (오구돌기하 충돌 증후군 유무에 따른 초음파를 이용한 상완오구돌기 계측)

  • Jang, Suk Hwan;Kim, Sang Bum
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.1
    • /
    • pp.20-27
    • /
    • 2014
  • Purpose: The purpose of this study was to evaluate coracohumeral distance (CHD) in patients with or without subcoracoid impingement with hypothesis that patients with subcoracoid impingement would have narrower CHD. Materials and Methods: One hundred twenty-four patients with subacromial impingement were evaluated. The subjects with subcoracoid impingement which was affirmed clinically and confirmed by ultrasound guided subcoracoid injection (n=28) was compared with patients with subacromial impingement only (n=96). Patients with stiffness and rotator cuff tear were excluded. Absolute CHD was measured on magnetic resonance imaging (MRI) axial images and on ultrasound with the humerus in neutral position and internal rotation. Also relative ratio of distance difference (RRDD) defined as the difference of CHD in neutral position and internal rotation compared with absolute CHD in neutral on ultrasound was also measured. Results: The distance measured in neutral position was similar between US imaging and MRI (p>0.05) and both measurements did not have significant difference between the two groups (p>0.05). On ultrasound, the difference in CHD in internal rotation between the two groups nearly met the level of significance (p=0.07). No significant difference of CHD difference in two humeral positions was seen between the two groups. However, RRDD value was significantly greater in subcoracoid impingement group (p<0.05). Conclusion: No significant difference of CHD was seen between the subcoracoid impingement group and the control group. RRDD value was greater in subcoracoid impingement group suggesting that individualized coracohumeral distance in internal rotation should be taken into account when assessing patients with subcoracoid impingement.

  • PDF

Evaluation on Organ Dose and Image Quality of Lumbar Spine Radiography Using Glass Dosimeter (유리선량계를 이용한 요추검사의 장기선량 및 영상의 평가)

  • Kim, Jae-Kyeom;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.1-11
    • /
    • 2016
  • The purpose of this study was to provide resources for medical exposure reduction through evaluation of organ dose and image resolution for lumbar spine around according to the size of the collimator in DR system. The size of the collimator were varied from $8^{\prime\prime}{\times}17^{\prime\prime}$ to $14^{\prime\prime}{\times}17^{\prime\prime}$ by 1" in AP and lateral projection for the lumbar spine radiography with RANDO phantom. The organ dose measured for liver, stomach, pancreas, kidney and gonad by the glass dosimeter. The image resolution was analyzed using the Image J program. The organ dose of around lumbar spine were reduced as the size of the collimator is decreased in AP projection. There were no significant changes decreasing rate whenever the size of the collimator were reduced 1" in the gonad. The organ dose showed higher on liver and kidney near the surface in lateral projection. There were decreasing rate of less than 5% in liver and kidney, but decreasing rate was 24.34% in the gonad whenever the size of the collimator were reduced 1". Organ dose difference for internal and external of collimator measured $549.8{\mu}Gy$ in the liver and $264.6{\mu}Gy$ in the stomach. There were no significant changes organ dose difference that measured $1,135.1{\mu}Gy$ in the gonad. Image Quality made no difference because SNR and PSNR were over than 30 dB when the collimator size is less than $9^{\prime\prime}{\times}17^{\prime\prime}$ on AP projection and $10^{\prime\prime}{\times}17^{\prime\prime}$ on lateral projection. Therefore, we are considered that the recommendations criterion for control of collimator were suggested in order to reduce unnecessary X-ray exposure and to obtain good image quality because lumbar spine radiography contains a lot of peripheral organs rather than other area radiography.

Efficiency of Staging Work-Ups in the Evaluation of Carcinoma of the Uterine Cervix (자궁경부암에 있어서 병기결정을 위한 검사의 효용성)

  • Kim, Jae-Sung;Ha, Sung-Whan
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.271-276
    • /
    • 1991
  • A series of 510 patients with carcinoma of the uterine cervix given the curative radiation therapy from March 1979 through December 1986 was evaluated to determine the value of intravenous pyelography (IVP), cystoscopy, sigmoidoscopy, and abdomino-pelvic CT as staging work-up prior to treatment. On IVP and cystoscopy, $10.7\%$(49/456) and $5.3\%$(24/452) showed abnormality, respectively, but only $0.7\%$(3/413) did on sigmoidoscopy. As a result of these work-ups prerequisite to FIGO staging, twenty six ($5.1\%$) out of 510 patients were upstaged from the stage determined by the findings of physical examination alone. The proportions of upstaging in each stage were as follows; none in stage IB (35), IIA (89) and IIIA (8), $7.9\%$(20/252) in stage IIB (14 patients to FIGO stage IIIB, 6 patients to FIGO stage IVA), and $4.8\%$(6/126) in stage IIIB (all to FIGO stage IVA). Positive findings of staging work-ups were found only in patients with advanced stages of stage IIB or over determined by physical examination alone but not in those with earlier stages. CT was performed in 337 patients. CT detected pelvic lymph node (LN) enlargement in $25.2\%$ (85/337) and paraaortic LN enlargement in $7.4\%$(25/337). Pelvic LN positivity was well correlated with increasing stage but paraaortic LN positivity was not. In the evaluation of parametrial involvement, CT findings were in accordance with those of physical examination only in $65.6\%$ (442/674). When compared with endoscopic studeies, CT had much lower positive predictive value than negative predicitive value in the evaluation of adjacent organ invasion. The staging work-ups should be individualized by the disease extent of each patient, and then the efficiency of work-uus may be increased without compromising the appropriate FIGO staging and treatment.

  • PDF

Analysis of Treatment Failure after Curative Radiotherapy in Uterine Cervical Carcinoma (자궁경부암에 있어서 방사선치료 후의 치료실패 분석)

  • Chai, Gyu-Young;Kang, Ki-Mun;Lee, Jong-Hak
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.224-229
    • /
    • 2001
  • Purpose : The aim of this study is to analyze the treatment failure patterns and the risk factors for locoregional or distant failure of uterine cervical carcinoma treated with radiation therapy. Materials and methods . A retrospective analysis was undertaken of 154 patients treated with curative radiation therapy in Gyeongsang National University Hospital from April 1989 through December 1997. According to FIGO classification, 12 patients were stage IB, 24 were IIA, 98 were IIB, 1 were IIIA, 17 were IIIB, 2 were IVA. Results : Overall treatment failure rate was $42.1\%$ (65/154), and that of complete responder was $31.5\%$ (41/130). Among 65 failures, 25 failed locoregionally, another 25 failed distantly, and 15 failed locoregionally and distantly. Multivariate analysis confirmed tumor size (>4 cm) as risk factor for locoregional failure, and tumor size (>4 cm), pelvic lymph node involvement as risk factors for distant failure. Conclusion : On the basis of results of our study and recent published data of prospective randomized study for locally advanced uterine cervical carcinoma, we concluded that uterine cervical carcinoma with size more than 4 cm or pelvic lymph node involvement should be treated with concurrent chemoradiation.

  • PDF