• Title/Summary/Keyword: 평가범위

Search Result 5,802, Processing Time 0.058 seconds

A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Ban, Yung-Kak;Lim, Han-Sang;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.159-165
    • /
    • 2010
  • Purpose: Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to $^{99m}Tc$ emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radiotechnologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radiotechnologists. Materials and Methods: Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8$ cm and mean weight: $65.9{\pm}1.4$ kg). Radiation were measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150 and 200 cm. Then, all the procedure was given with a portable radiation shielding on the location of head, chest and abdomen at the distance of 100, 150 and 200 cm and transmittance was calculated. Results: In 10 cm, head (105.40 ${\mu}Sv/h$) was the highest and foot (15.85 ${\mu}Sv/h$) was the lowest. In 200 cm, head, chest and abdomen showed similar. On head, the measured dose rates were 9.56 ${\mu}Sv/h$, 5.23 ${\mu}Sv/h$, and 3.40 ${\mu}Sv/h$ in 100, 150 and 200 cm respectively. When using shielder, it shows 2.24 ${\mu}Sv/h$, 1.67 ${\mu}Sv/h$, and 1.27 ${\mu}Sv/h$ in 100, 150 and 200 cm on head. On chest, the measured dose rates were 8.54 ${\mu}Sv/h$, 4.90 ${\mu}Sv/h$, 3.44 ${\mu}Sv/h$ in 100, 150 and 200 cm, respectively. When using shielder, it shows 2.27 ${\mu}Sv/h$, 1.34 ${\mu}Sv/h$, and 1.13 ${\mu}Sv/h$ in 100, 150 and 200 cm on chest. On abdomen, the measured dose rates were 9.83 ${\mu}Sv/h$, 5.15 ${\mu}Sv/h$ and 3.18 ${\mu}Sv/h$ in 100, 150 and 200cm respectively. When using shielder, it shows 2.60 ${\mu}Sv/h$, 1.75 ${\mu}Sv/h$ and 1.23 ${\mu}Sv/h$ in 100, 150 and 200 cm on abdomen. Transmittance was increased as the distance was expanded. Conclusion: As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the radiotechnologists.

  • PDF

Analysis of the Radiation Therapy Outcomes and Prognostic Factors of Thymoma (흉선종에 대한 방사선치료 성적 및 예후인자분석)

  • Lee, Seok-Ho;Lee, Kyu-Chan;Choi, Jin-Ho;Lee, Jae-Ik;Sym, Sun-Jin;Cho, Eun-Kyung
    • Radiation Oncology Journal
    • /
    • v.28 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • Purpose: This retrospective study was performed to evaluate the efficacy of radiation therapy (RT) and to investigate the prognostic factors for thymoma when treated with RT. Materials and Methods: We analyzed 21 patients with thymoma and also received RT from March 2002 to January 2008. The median follow-up time was 37 months (range, 3 to 89 months). The median patient age was 57 years (range, 24 to 77 years) and the gender ratio of males to females was 4:3. Of the 21 patients, complete resections (trans-sternal thymectomy) and R2 resections were performed in 14 and 1 patient, respectively. A biopsy was performed in 6 patients (28.7%). The WHO cell types in the 21 patients were as follows: 1 patient (4.8%) had type A, 10 patients (47.6%) had type B1-3, and 10 patients (47.6%) had type C. Based on Masaoka staging, 10 patients (47.6%) were stage II, 7 patients (33.3%) were stage III, and 4 patients (19.1%) were stage IVa. Three-dimensional RT was adminstered to the tumor volume (planned target volume), including the anterior mediastinum and the residual disease. The total RT dose ranged from 52.0 to 70.2 Gy (median dose, 54 Gy). Consistent with the WHO criteria, the response rate was only analyzed for the 6 patients who received a biopsy only. The prognostic factors analyzed for an estimate of survival included age, gender, tumor size, tumor pathology, Masaoka stage, the possibility of treatment by performing surgery, the presence of myasthenia gravis, and RT dose. Results: The 3-year overall survival rate (OS) and the progression free survival rate (PFS) were 80.7% and 78.2%, respectively. Among the 10 patients with WHO cell type C, 3 of 4 patients (75%) who underwent a complete resection and 3 of 6 patients (50%) who underwent a biopsy survived. Distant metastasis developed in 4 patients (19.1%). The overall response rate in the 6 patients who received biopsy only were as follows: partial remission in 4 patients (66.7%), stable disease in 1 patient (16.6%), and progressive disease in 1 patient (16.6%). Acute RTOG radiation pneumonitis occurred in 1 patient (4.8%), grade 2 occurred in 2 patients (9.5%), grade 3 occurred in 1 patient (4.8%), and grade 4 occurred in 1 patient (4.8%). A univariate analysis revealed that the significant prognostic factors for OS were age (${\geq}60$, 58.3%; <60, 100%; p=0.0194), pathology (WHO cell type A-B3, 100%; C, 58.3%; p=0.0194) and, whether the patient underwent surgery (yes, 93.3%; no, 50%; p=0.0096). Conclusion: For the 15 patients who received surgery, there was no local failure within the radiation field. In patients with WHO cell type C, surgical procedures could have resulted in a more favorable outcome than biopsy alone. We report here our clinical experience in 21 patients with thymoma who were treated by radiation therapy.

Analysis of Quantitative Indices in Tl-201 Myocardial Perfusion SPECT: Comparison of 4DM, QPS, and ECT Program (Tl-201 심근 관류 SPECT에서 4DM, QPS, ECT 프로그램의 정량적 지표 비교 분석)

  • Lee, Dong-Hun;Shim, Dong-Oh;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.67-75
    • /
    • 2009
  • Purpose: As to the analytical method of data, the various programs in which it is used for the quantitative rating of the Tl-201 myocardial perfusion SPECT are reported that there is a difference. Therefore, the measured value error of the mutual program is expected to be generated even if the quantitative analysis is made against data of the same patient. Using quantitative index that able to represent myocardial perfusion defect level, we aimed to determine correlation among three myocardial perfusion analysis programs 4DM (4DMSPECT), QPS (Quantitative Perfusion SPECT), ECT (Emory Cardiac Toolbox) that be used generally in most departments of Nuclear Medicine. Materials and Methods: We analyzed the 145 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Mediacal Center from December 1th 2008 to February 14th 2008. We sorted as normal group and abnormal group. Normal group consist of 80 patients (Male/Female=38/42, age:$65.1{\pm}9.9$) who have low possibility of cardiovascular disease. And abnormal group consist of 65 patients (Male/Female=45/20, age:$63.0{\pm}8.7$) who were diagnosed cardiovascular disease with reversible perfusion defect or fixed perfusion defect through myocardial perfusion SPECT results. Using the 4DM, QPS, and ECT programs, the total defect extent (TDE) such as LAD, LCX, RCA and the summed stress score (SSS) have been analysed for their correlations and statistical comparison with the paried t-test for the quantitative indices analysed from each group. Results: The correlation of 4DM:QPS, QPS:ECT, ECT:4DM each group result from 145 patients is 0.84, 0.86, 0.82 at SSS, 0.87, 0.84, 0.87 at TDE, and both index showed good correlation. In paired t-test and Bland-Altman analysis results showed no statistically significant difference in the comparison of QPS:ECT at the mean SSS and TDE, 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index. The correlation of 4DM:QPS, QPS:ECT, ECT:4DM program results from abnormal group (65 patients) is 0.72, 0.72, 0.70 at SSS and 0.77, 0.70, 0.77 at TDE and TDE and SSS has a good correlation. In abnormal group, paired t-test and Bland-Altman analysis results showed no statistically significant difference at QPS:ECT SSS (p=0.89) and TDE (p=0.23) comparison, 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index (p<0.01). In normal group (80 patients), paired t-test and Bland-Altman analysis results showed no statistically significant difference at QPS:ECT SSS (p=0.95) and TDE (p=0.73) comparison. And 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index (p<0.01). Conclusions: The perfusion defect of the Tl-201 myocardial perfusion SPECT was analyzed in not only the patient in whom it has the cardiovascular disease but also the patient in whom the possibility of the cardiovascular disease is few. In the comparison of the all group research, the mean of the TDE and SSS, 4DM was lower than QPS and ECT progrms. Each program showed good correlation and the results showed statistically significant difference. However, in this way, it is determined to be compatible about the analysis value in which the large-scale side between the programs uses each program a difference in a clinical in the Bland-Altman analyzed result in spite of the good correlation and cannot use. but, this analyzed result will be able to be usefully used as the reference material for the clinical read and is expected.

  • PDF

Potassium Availability and Physical Properties of Upland Soils (밭토양(土壤)의 물리성(物理性)과 가리(加里))

  • Yoo, S.H.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.10 no.3
    • /
    • pp.189-201
    • /
    • 1977
  • Some of basic aspects of soil potassium with special reference to soil physical properties were discussed. Data in the Official Soil Series Description(Korea) was analyzed according to soil type, land form, and soil texture to find soil potassium status which may explain different response to potassium application. Exchangeable potassium contents decreased with soil depth irrespective of soil type, land form and soil texture. Change in degree of potassium saturation within soil profile was not so clear as exchangeable potassium but the degree of potassium saturation of A horizon was highest among soil horizon. Soils of terrace and mountain foot slope showed high values both in exchangeable potassium and degree of potassium sauration and only these two soils were classified as soils having exchangeable potassium higher than 0.3 meq per 100g of soil and degree of potassium saturation higher than 5.0%. Exchangeable potassium of fine loamy and fine clayey soils is higher than 0.3 meq per 100g of soil but degree of potassium saturation is lower than 4.0%. Degree of potassium saturation of sandy soils exceeds 5.0% but exchangeable potassium is very low. Soils of rolling, hilly, unmatured and alpine land soils have lower exchangeable potassium and show lower degree of potassium saturation. The highest distribution of exchangeable potassium content irrespective of soil horizons was shown in the range of 0.1-0.2 meq per 100g of soil. The highest distribution of degree of potassium saturation was in the range of 2.0-3.0% in A horizon and 1.0-2.0% in B and C horizons. Of the soil series concerned in this analysis, 27.3% in A horizon, 11.1% in B horizon and 4.0% in C horizon had exchangeable potassium higher than 0.3 meq per 100g of soil and 18.0% in A horizon, 6.3% in B horizon, and 4.1% in C horizon showed degree of potassium saturation higher than 5.0%. The low response of potassium application only to soils in terrace and mountain foot slope may be resulted from the high exchangeable potassium content and high degree of potassium saturation. It is concluded that a great response of potassium application to soils is expected especially in dry season.

  • PDF

A CLINICAL STUDY ON TOURETTE'S DISORDER (뚜렛 장애의 임상적 연구)

  • Min, Sung-Kil;Noh, Kyung S.;Shin, Dong-Won
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.8 no.1
    • /
    • pp.92-100
    • /
    • 1997
  • Objective:The objective of this study is to examine the clinical characteristics and behavioral comorbidity of patients with Tourette’s disorder. Method:Subjects consisted of 157 patients with Tourette’ disorder diagnosed by DSM-IIIR, who were examined and diagnosed from Jan. 1988 to May 1994 at the Tourette’s Clinic of Yonsei University Medical Center. Characteristics and behavioral comorbidity of Patients were assessed by a semi-structured interview schedule. Behavioral problems like hyperactivity, obsession-compulsion, self destructiveness, enuresis, sleep problem were assessed by global clinical impression. Results:The mean age of patients was 14.49(${\pm}7.99$) years. Patients consisted of 138 males (87.9%) and 19 females(12.1%). The sex ratio was 7:1, showing a male preponderance. The number of right-handers was 133(84.7%), and the number of non-right handers was 24(15.3%). Mean age of onset was 8.85(${\pm}4.56$) years, ranging from 2-to-16 years. More than half of the patients had their age of onset at 6-10 years. Bimodal peak in age of onset was observed;the first peak was around 6 and the second peak was around 10 years. There was no sex difference in bimodal age of onset. The most common initial symptom was eye blinking. More than 55% of patients reported eye blinking as their first symptom. The second common initial symptom was head turning and the third was vocal tic. The most common symptoms that patients reported on their first visit since onset were eye blinking(82.2%), head turning or nodding(57.9%), shoulder shrugging(52.7%) and forearm movement(32.6%). Of 157 cases, 101(64.3%) patients showed downward progression of symptoms, and 25(15.9%) showed upward progression of symptoms. Nineteen fathers(12%) of patients had a past history of obsessive-compulsive disorder(OCD). Seventeen fathers(10.6%) had a history of tic disorder. SSevenmothers(4.5%) had OCD, 4 mothers (2.5%) had tic disorder. One hundred and eighteen patients(75.1%) had comorbid hyperactivity, 95 patients(60.5%) had obsession, 55 patiens(35.0%) had self destructiveness, 46 patients(29.3%) had impulsivity, and 35 patients(22.3%) had enuresis. Age of onset had a significant positive correlation with age, duration, and the global severity of obsession;and a negative correlation with the severity of hyperactivity. Hyperactivity had a significant positive correlation with impulsivity, obsession-compulsion, enuresis, and self destructiveness. Obsession-compulsion had a significant positive correlation with hyperactivity, sleep problems, and self destructiveness. Conclusion:These data suggest that clinical characteristcs and behavioral comorbidity of patients with Tourette’ disorder in this study are similar to previous research findings in Korea and other contries. The younger the age of onset was, the more severe hyperactivity was, and the less severe obsession-compulsion was. And severity of hyperactivity had a positive correlation with the severity of obsession-compulsion, impulsivity, enuresis, and self destructiveness.

  • PDF

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.

Tenderness Survey of Branded Hanwoo Beef - 2007: Assessment of Warner-Bratzler Shear for Hanwoo Beef by Quality Grade and Subprimal Cuts (브랜드 한우고기 연도 조사 - 2007 : 육질등급 및 소분할 부위별 전단력 평가)

  • Kim, Jin-Hyoung;Seong, Pil-Nam;Cho, Soo-Hyun;Jeong, Da-Woon;In, Tae-Sik;Jeong, Jin-Hyung;Park, Beom-Young;Lee, Jong-Moon;Kim, Dong-Hun;Ahn, Chong-Nam
    • Food Science of Animal Resources
    • /
    • v.28 no.3
    • /
    • pp.283-288
    • /
    • 2008
  • Eight subprimal cuts purchased from the branded Hanwoo beef of 3 quality grades ($1^{++}$, $1^+$, 1) at 13 stores were evaluated the tenderness using Warner-Bratzler shear (WBS). The beef frequency ratio (%) depending on postmortem aging periods were investigated. The 37.5 (quality grade $1^{++}$), 45.8 (quality grade $1^+$), and 36.4% (quality grade $1^{++}$) of branded beef were aged for < 7 d, 26.6 (quality grade $1^{++}$), 47.2 (quality grade $1^+$) and 36.4% (quality grade 1) were aged for $7{\sim}13$ d, and 31.3 (quality grade $1^+$), 4.2 (quality grade $1^+$) and 25.8% (quality grade $1^+$) were aged for 14 to 20 d. The temperature of cold room in stores was ranged average 2.27 to $2.42^{\circ}C$. WBS values for ansimsal (tenderloin), witdngsimsal (ribeye), cheggtsal (shortloin), doganisal (knuckle) and moongchisatae (hind shank) from branded Hanwoo beef of quality grade $1^{++}$ were tender than those from branded Hanwoo beef of quality grade 1 (p<0.05). WBS values for ansimsal (tenderloin) were 2.56 (quality grade $1^{++}$), 2.76 (quality grade $1^+$) and 3.10 kg (quality grade 1), respectively, and those for doganisal (knuckle, quality grade $1^{++}$), hongdukesal (eye of round, quality grade $1^+$) and bosupsal (top sirloin, quality grade 1) were 4.76, 4.96 and 5.66kg, respectively (p<0.05). The frequency ratio (%) of WBS < 3.9 kg in the all subprimal cuts from branded Hanwoo beef of quality grade $1^{++}$ were 100 [ansimsal (tenderloin) and cheggtsal (shortloin)], 87.5 [witdngsimsal (ribeye)] and 62.5% [bosupsal (top sirloin)], whereas that of WBS > 4.6 kg were 50.0% [hongdukesal (eye of round) and doganisal (knuckle)]. The frequency ratio of WBS < 3.9 kg in the an subprimal cuts of quality grade $1^+$ were 100 [ansimsal (tenderloin) and witdngsimsal (ribeye)] and 44.4% [cheggtsal (shortloin) and gurisal (chuck tender)], whereas that of WBS > 4.6 kg were 66.7 [hongdukesal (eye of round)], 55.6 [doganisal (knuckle)] and 44.4% [bosupsal (top sirloin)]. The frequency ratio (%) of WBS < 3.9 kg in the all subprimal cuts of quality grade 1 were 88.9 [ansimsal (tenderloin)], 62.5 [cheggtsal (shortloin)] and 44.4% [witdngsimsal (ribeye)], whereas that of WBS > 4.6 kg were 100.0 [doganisal (knuckle)] 62.7 [hongdukesal (eye of round)], 62.5 [gurisal (chuck tender)] and 55.6% [moongchisatae (hind shank)]. From these results, subprimal cuts from branded Hanwoo beef were marketed with short aging periods and high frequency ratio (%) of WBS > 4.6 kg.

The Study on Usefulness of LEAP Collimator in Lung Ventilation SPECT (Lung Ventilation SPECT에서 LEAP Collimator의 유용성에 관한 연구)

  • Kim, Jung Soo;Kim, Soo Mee;Kim, Jin Eui;Lee, Jae Sung;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.18-24
    • /
    • 2012
  • Purpose : Although lung ventilation SPECT (LV-SPECT) has a good sensitivity in detection of deep lung lesions, it is difficult to apply the LV-SPECT to patients having breathing problems due to limited examination time. In this study, we evaluated the usefulness of LEAP collimator, which provides high detection sensitivity and tolerable resolution, for the LV-SPECT in terms of diagnostic accuracy and examination time. Materials and Methods : Four volunteers inhaled Technegas (370 MBq) and the lung ventilation planar scan (LVPS, 300 counts/view (cpv)) with LEHR collimator was performed using Siemens E.cam scanner as a reference test. LV-SPECT scans were performed with three collimators, LEHR, LEUHR, and LEAP, in low (7 kcpv) and high (70 kcpv) counting modes. The count ratios of left (LT) and right (RT) lung segments were calculated on the geometric mean view of anterior and posterior images for LVPS and on the summed coronal images of LV-SPECT, respectively. Comparing to LVPS, the usefulness of three different collimators for LV-SPECT was evaluated through statistical analysis (paired t-test), on count ratios of lung segments. Results : The average LT:RT ratio in LVPS was 47:53. For LV-SPECT, there were negligible difference of the LT:RT ratios (48:52 on average) among three different collimators in low and high counting modes. Comparing to standard LVPS with LEHR, all LV-SPECTs with different collimators resulted in similar diagnostic accuracy through paired t-test (p>0.05). The scan time in LVPS (6 views) was 17.3 min. For LV-SPECT (128 views) in low counting mode, it took 18.7 (LEUHR), 15.0 (LEHR), and 12.3 min (LEAP), respectively. Conclusion : Comparing to standard LVPS, the LV-SPECT with LEAP in low counting mode provided the comparable diagnostic accuracy in addition to shortened scan time.

  • PDF

A Therapeutic Effect of Ozonated Oil on Bovine Mastitis (젖소 유방염에 대한 Ozonated oil의 치료효과)

  • Jo Sung-Nam;Liu Jianzhu;Lee Sang-Eun;Hong Min-Sung;Kim Duck-Hwan;Kim Myung-Cheol;Cho Sung-Whan;Jun Moo-Hyung
    • Journal of Veterinary Clinics
    • /
    • v.22 no.4
    • /
    • pp.318-321
    • /
    • 2005
  • Forty- nine quarters from 24 lactating cows with chronic mastitis were selected. The cows were raised on dairy farms in Gongju, Jochiwon and Yeongi in Chungnam province, and Iksan in Jeonbuk province, Korea. The 49 quarters with bovine mastitis were divided into control (7 quarters) and experimental (42 quarters) groups. The experimental quarters were assigned to experimental group A (10 quarters, somatic cell count: $50-100\times10^4/ml)$, experimental group B (14 quarters, somatic cells count: $100-300{\times}10^4/ml)$, and experimental group C (18 quarters, somatic cells count: $>300\times10^4/ml$), according to the number of the somatic cells in their milk. The quarters of control group were treated with norfloxacin ointment (10 g/tube) based on the result of sensitivity, twice a day for 3 days. The quarters or experimental groups were infused 10ml or ozonated oils twice a day for 3 days. After treatment, the milk of the control group contained non-significantly lower numbers of somatic cells and bacteria on day 7, compared with pretreatment levels. Experimental groups A, B and C had lower somatic and bacterial cells in their milk on day 7, compared with pretreatment levels. Experimental group B and C had significantly lower numbers of somatic cells in their milk ell day 7 than before treatment (p<0.01). However, no significant difference in somatic cell numbers was detected between the control alld experimental groups. It was concluded that ozone therapy with ozonated oil applied on bovine mastitis might be effective.

A survey on daily physical activity level, energy expenditure and dietary energy intake by university students in Chungnam Province in Korea (충남지역 대학생의 신체활동수준, 에너지소비량 및 에너지섭취량 조사)

  • Kim, Sun Hyo
    • Journal of Nutrition and Health
    • /
    • v.46 no.4
    • /
    • pp.346-356
    • /
    • 2013
  • This study investigated the daily physical activity level, energy expenditure, energy balance, and body composition and their relationship with university students. The participants were 130 male students ($19.5{\pm}0.5$ yrs) and 139 female students ($19.5{\pm}0.3$ yrs) at a university in Chungnam province. Physical activity level was evaluated by an equation based on 24 hr-activity record and dietary nutrient intake was evaluated using the food record method during a three-day period consisting of two week days and one weekend. Body composition was measured using Inbody 430 (Biospace Co., Cheonan, Korea). As a result, mean body mass index (BMI) of subjects indicated that they had normal weight, however mean body fat ratio was $19.1{\pm}5.4%$ for males and $28.4{\pm}5.0%$ for females, indicating that they had higher than normal weight. Daily mean physical activity level was 1.55 for males and 1.47 for females, which was regarded as 'low active', respectively. Females had more light activity than males (p<0.01). Daily mean energy expenditure was $2,803.5{\pm}788.9$ kcal/d for males and $1,915.4{\pm}510.2$ kcal/d for females (p<0.001). Daily mean dietary energy intake was $2,327.0{\pm}562.5$ kcal/d for males and $1,802.1{\pm}523.6/d$ for females (p<0.001), and daily mean energy balance was $-476.5{\pm}955.9$ kcal/d for males and $-113.3{\pm}728.1$ kcal/d for females (p<0.01). Daily mean dietary intake of protein, vitamins, and minerals, except Ca, satisfied recommended nutrient intake. Daily energy expenditure was positively related to body weight (p<0.01), BMI (p<0.01), and fat free mass ratio (p<0.05), but was negatively related to body fat ratio (p<0.01). In conclusion, subjects had a negative energy balance and low physical activity. They had a normal weight by BMI but had a more fat than normal weight by body fat ratio. This appears to be related to their low physical activity. Thus, nutrition education should be provided for university students in order to increase their physical activity for maintenance of normal weight by body composition and health promotion.