• Title/Summary/Keyword: 편차각

Search Result 1,063, Processing Time 0.035 seconds

Determining the Orientation of Accelerograph Stations in South Korea using Ambient Noise Data (배경잡음 자료를 이용한 국내 가속도 관측망의 방위각 보정값 측정)

  • Lee, Sang-Jun
    • Journal of the Korean earth science society
    • /
    • v.42 no.2
    • /
    • pp.195-200
    • /
    • 2021
  • Orientation corrections for the total of 268 accelerograph stations of the Korea Meteorological Administration (KMA) were estimated using ambient noise cross-correlation. As this method uses ambient noise data instead of teleseismic waveforms from earthquakes under certain conditions, reliable orientation corrections can be obtained using only two-month long continuous seismic data from dense seismic networks in the Korean peninsula.Three-component continuous data recorded at the 268 accelerograph stations from January to February 2020 were used to estimate orientation corrections. The results are comparable to the previous results obtained from teleseismic waveforms; the overall standard deviations of the orientation corrections are less than 5°. Therefore, orientation corrections for the accelerograph station network can be tracked periodically by the ambient-noise method and the result can be used in various studies using the horizontal-component of acceleration data.

A Study on the Deviation of Cluster Based on Template Images of Korean Children's Brain SPECT Image Using the Statistical Parametic Mapping (통계적 파라미터 뇌지도작성을 이용한 국내 어린이 뇌 SPECT영상의 표준틀영상에 따른 화소덩어리의 편차연구)

  • 신동호;박성옥;권수일;조철우;윤석남;이명훈;신동오
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.45-53
    • /
    • 2004
  • SPM has been widely applied for comparison studios of the functional image data among groups of patients or individuals under different conditions and these images are from people ranging from children to adults. However, the analysis of children's brain images by using SPM can make children's brain images normalized to an adult's template image and this can result in some errors. So this study created the children's mean MR images based on the Magnetic Resonance Images of 36 normal children (age: 2~6, average age: 4.36, SD age: 1.41, M/F: 17/19), and the children's mean SPECT images by using SPECT images of 13 normal children (age: 2~6, average age: 4.80, SD age: 1.17, M/F: 10/3). We created the Korean children's brain template image, based on those mean images, and then we compared between the positions of the clusters, based on the blood flow, by normalizing ADHD children's SPECT image to Korean children's template image and SPM adult's template image. As a result of the analysis, the variation of the cluster positions was found to be a maximum of 25 ㎜. Therefore, we should be aware that we need to consider the template image and the p-value when we analyze the chlidren's brain image by using SPM.

  • PDF

Evaluation of improvement effect on the spatial-temporal correction of several reference evapotranspiration methods (기준증발산량 산정방법들의 시공간적 보정에 대한 개선효과 평가)

  • Kim, Chul-Gyum;Lee, Jeongwoo;Lee, Jeong Eun;Kim, Hyeonjun
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.9
    • /
    • pp.701-715
    • /
    • 2020
  • This study compared several reference evapotranspiration estimated using eight methods such as FAO-56 Penman-Monteith (FAO PM), Hamon, Hansen, Hargreaves-Samani, Jensen-Haise, Makkink, Priestley-Taylor, and Thornthwaite. In addition, by analyzing the monthly deviations of the results by the FAO PM and the remaining seven methods, monthly optimized correction coefficients were derived and the improvement effect was evaluated. These methods were applied to 73 automated synoptic observation system (ASOS) stations of the Korea Meteorological Administration, where the climatological data are available at least 20 years. As a result of evaluating the reference evapotranspiration by applying the default coefficients of each method, a large fluctuation happened depending on the method, and the Hansen method was relatively similar to FAO PM. However, the Hamon and Jensen-Haise methods showed more large values than other methods in summer, and the deviation from FAO PM method was also large significantly. When comparing based on the region, the comparison with FAO PM method provided that the reference evapotranspiration estimated by other methods was overestimated in most regions except for eastern coastal areas. Based on the deviation from the FAO PM method, the monthly correction coefficients were derived for each station. The monthly deviation average that ranged from -46 mm to +88 mm before correction was improved to -11 mm to +1 mm after correction, and the annual average deviation was also significantly reduced by correction from -393 mm to +354 mm (before correction) to -33 mm to +9 mm (after correction). In particular, Hamon, Hargreaves-Samani, and Thornthwaite methods using only temperature data also produced results that were not significantly different from FAO PM after correction. It can be also useful for forecasting long-term reference evapotranspiration using temperature data in climate change scenarios or predicting evapotranspiration using monthly or seasonal temperature forecasted values.

Analysis of Spatial and Vertical Variability of Environmental Parameters in a Greenhouse and Comparison of Carbon Dioxide Concentration in Two Different Types of Greenhouses (온실 환경요인의 공간적 및 수직적 특성 분석과 온실 종류에 따른 이산화탄소 농도 비교)

  • Jeong, Young Ae;Jang, Dong Cheol;Kwon, Jin Kyung;Kim, Dae Hyun;Choi, Eun Young
    • Journal of Bio-Environment Control
    • /
    • v.31 no.3
    • /
    • pp.221-229
    • /
    • 2022
  • This study was aimed to investigate spatial and vertical characteristics of greenhouse environments according to the location of the environmental sensors, and to investigate the correlations between temperature, light intensity, and carbon dioxide (CO2) concentration according to the type of greenhouse. Temperature, relative humidity (RH), CO2, and light sensors were installed in the four-different vertical positions of the whole canopy as well as ground and roof space at the five spatial locations of the Venlo greenhouse. Also, correlations between temperature, light intensity, and CO2 concentration in Venlo and semi-closed greenhouses were analyzed using the Curve Expert Professional program. The deviations among the spatial locations were larger in the CO2 concentration than other environmental factors in the Venlo greenhouse. The average CO2 concentration ranged from 465 to 761 µmol·mol-1 with the highest value (646 µmol·mol-1) at the Middle End (4ME) close to the main pipe (50Ø) of the liquefied CO2 gas supply and lowest (436 µmol·mol-1) at the Left Middle (5LM). The deviation among the vertical positions was greater in temperature and relative humidity than other environments. The time zone with the largest deviation in average temperature was 2 p.m. with the highest temperature (26.51℃) at the Upper Air (UA) and the lowest temperature (25.62℃) at the Lower Canopy (LC). The time zone with the largest deviation in average RH was 1 p.m. with the highest RH (76.90%) at the LC and the lowest RH (71.74%) at the UA. The highest average CO2 concentration at each hour was Roof Air (RF) and Ground (GD). The coefficient of correlations between temperature, light intensity, and CO2 concentration were 0.07 for semi-closed greenhouse and 0.66 for Venlo greenhouse. All the results indicate that while the CO2 concentration in the greenhouse needs to be analyzed in the spatial locations, temperature and humidity needs to be analyzed in the vertical positions of canopy. The target CO2 fertilization concentration for the semi-closed greenhouse with low ventilation rate should be different from that of general greenhouses.

The feasibility evaluation of Respiratory Gated radiation therapy simulation according to the Respiratory Training with lung cancer (폐암 환자의 호흡훈련에 의한 호흡동조 방사선치료계획의 유용성 평가)

  • Hong, mi ran;Kim, cheol jong;Park, soo yeon;Choi, jae won;Pyo, hong ryeol
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.149-159
    • /
    • 2016
  • Purpose : To evaluate the usefulness of the breathing exercise,we analyzed the change in the RPM signal and the diaphragm imagebefore 4D respiratory gated radiation therapy planning of lung cancer patients. Materials and Methods : The breathing training was enforced on 11 patients getting the 4D respiratory gated radiation therapy from April, 2016 until August. At the same time, RPM signal and diaphragm image was obtained respiration training total three steps in step 1 signal acquisition of free-breathing state, 2 steps respiratory signal acquisition through the guide of the respiratory signal, 3 steps, won the regular respiration signal to the description and repeat training. And then, acquired the minimum value, maximum value, average value, and a standard deviation of the inspiration and expiration in RPM signal and diaphragm image in each steps. Were normalized by the value of the step 1, to convert the 2,3 steps to the other distribution ratio (%), by evaluating the change in the interior of the respiratory motion of the patient, it was evaluated breathing exercise usefulness of each patient. Results : The mean value and the standard deviation of each step were obtained with the procedure 1 of the RPM signal and the diaphragm amplitude as a 100% reference. In the RPM signal, the amplitudes and standard deviations of four patients (36.4%, eleven) decreased by 18.1%, 27.6% on average in 3 steps, and 2 patients (18.2%, 11 people) had standard deviation, It decreased by an average of 36.5%. Meanwhile, the other four patients (36.4%, eleven) decreased by an average of only amplitude 13.1%. In Step 3, the amplitude of the diaphragm image decreased by 30% on average of 9 patients (81.8%, 11 people), and the average of 2 patients (18.2%, 11 people) increased by 7.3%. However, the amplitudes of RPM signals and diaphragm image in 3steps were reduced by 52.6% and 42.1% on average from all patients, respectively, compared to the 2 steps. Relationship between RPM signal and diaphragm image amplitude difference was consistent with patterns of movement 1, 2 and 3steps, respectively, except for No. 2 No. 10 patients. Conclusion : It is possible to induce an optimized respiratory cycle when respiratory training is done. By conducting respiratory training before treatment, it was possible to expect the effect of predicting the movement of the lung which could control the patient's respiration. Ultimately, it can be said that breathing exercises are useful because it is possible to minimize the systematic error of radiotherapy, expect more accurate treatment. In this study, it is limited to research analyzed based on data on respiratory training before treatment, and it will be necessary to verify with the actual CT plan and the data acquired during treatment in the future.

  • PDF

Accuracy of 5-axis precision milling for guided surgical template (가이드 수술용 템플릿을 위한 5축 정밀가공공정의 정확성에 관한 연구)

  • Park, Ji-Man;Yi, Tae-Kyoung;Jung, Je-Kyo;Kim, Yong;Park, Eun-Jin;Han, Chong-Hyun;Koak, Jai-Young;Kim, Seong-Kyun;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.294-300
    • /
    • 2010
  • Purpose: The template-guided implant surgery offers several advantages over the traditional approach. The purpose of this study was to evaluate the accuracy of coordinate synchronization procedure with 5-axis milling machine for surgical template fabrication by means of reverse engineering through universal CAD software. Materials and methods: The study was performed on ten edentulous models with imbedded gutta percha stoppings which were hidden under silicon gingival form. The platform for synchordination was formed on the bottom side of models and these casts were imaged in Cone beam CT. Vectors of stoppings were extracted and transferred to those of planned implant on virtual planning software. Depth of milling process was set to the level of one half of stoppings and the coordinate of the data was synchronized to the model image. Synchronization of milling coordinate was done by the conversion process for the platform for the synchordination located on the bottom of the model. The models were fixed on the synchordination plate of 5-axis milling machine and drilling was done as the planned vector and depth based on the synchronized data with twist drill of the same diameter as GP stopping. For the 3D rendering and image merging, the impression tray was set on the conbeam CT and pre- and post- CT acquiring was done with the model fixed on the impression body. The accuracy analysis was done with Solidworks (Dassault systems, Concord, USA) by measuring vector of stopping’s top and bottom centers of experimental model through merging and reverse engineering the planned and post-drilling CT image. Correlations among the parameters were tested by means of Pearson correlation coefficient and calculated with SPSS (release 14.0, SPSS Inc. Chicago, USA) ($\alpha$ = 0.05). Results: Due to the declination, GP remnant on upper half of stoppings was observed for every drilled bores. The deviation between planned image and drilled bore that was reverse engineered was 0.31 (0.15 - 0.42) mm at the entrance, 0.36 (0.24 - 0.51) mm at the apex, and angular deviation was 1.62 (0.54 - 2.27)$^{\circ}$. There was positive correlation between the deviation at the entrance and that at the apex (Pearson Correlation Coefficient = 0.904, P = .013). Conclusion: The coordinate synchronization 5-axis milling procedure has adequate accuracy for the production of the guided surgical template.

An Analysis and Design of Wideband Microstrip Rotman Lens by Contour Integral and Segmentation Method (경계적분법과 세그멘테이션 기법에 의한 광대역 마이크로스트립 로트만 렌즈의 해석 및 설계)

  • 이광일;오승엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.7
    • /
    • pp.769-776
    • /
    • 2003
  • This paper presents analysis and design of microstrip Rotman lens operating over wide band and wide steering angle by the contour integral method along with the segmentation method. All mutual coupling, internal reflections between ports and the discontinuity at every junction are taken into account. Equally spaced ports are designed and realized, which make suppress output ripple through the array ports. Impedance matching and mutual coupling between ports are analyzed and optimized using 12 input and 12 output exponential tapers. The measured results of fabricated lens show ${\pm}$ 1.8 dB insertion loss deviation over 6∼18 GHz wide frequency range and beam steering accuracy less than 1$^{\circ}$over ${\pm}$53$^{\circ}$angle and agrees well with the analysis results.

The Acidity and Chemical Compositions of the Snowfall at Pinus koraiensis Stand in Pyungchang Region - A centering around the Daegwalyung and Woongyori - (강원도 평창지역의 산림내 강설 산성도와 화학적 조성 -대관령과 운교리를 중심으로 -)

  • 김영채;정동준;김홍률
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.3 no.3
    • /
    • pp.143-149
    • /
    • 2001
  • This study was conducted to analyze the propertis, acidity and chemical compositions of the snowfall in the bare land and Idlest stand. The research sites of this study are the Daegwalyung (a high hill) and Woongyori in Pyungchang-gun, Kangwon province. The results of this study are as follows: The snowfall pH showed large changes when the snowfall was small. The more snow falls, the smaller changes of the pH are narrow. According to the local conditions, it means that the acid deposition changed over adsorption ratio in suspended matters of the atmosphere. Changes of the ion concentrations for the snowfall in the forest stand showed a thendency to increase. Chemical composition of the snowfall for each sampling site showed that the ion concentrations of $Ca^{2+}$and anions had higher value than other ions.s.

  • PDF

STUDY OF CRANIOCERVICAL POSTURE AND CRANIOFACIAL MORPHOLOGY IN KOREAN YOUNG ADULTS (한국 성인의 두경부자세와 두개안면형태에 관한 두부 X-선 계측학적 연구)

  • Park, Eun-Jue;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.25 no.2 s.49
    • /
    • pp.129-142
    • /
    • 1995
  • The purpose of this study was to estimate correlations of craniocervical posture and craniofacial morphology in Korean young adults. The sample consisted of 50 young adults (25 males and 25 females) who had good profile and Class I molar relationship. The analysis of craniocervical posture and craniofacial morphology was performed on lateral cephalograms taken in natural head position. The results were as follows, 1. The mean and the standard deviation of postural and morphologic variables were obtained. 2. Korean young adult had cervical lordosis of which degree between OPT and CVT shows $3.55{\pm}2.58^{\circ}$ 3. Craniocervical posture and each of vertical ratio, facial prognathism, mandibular rotation showed high correlation. 4. Correlation coefficients between postural variables and each of intermaxillary relation, anteroposterior ratio were low. 5. The head positioning error of natural head position was smaller than the inter-individual variability of postural variables.

  • PDF

A Study on Magnetoresistance Uniformity of NiFE/CoFe/AlO/CoFe/Ta TMR Devices Prepared by ICP Sputtering (ICP 스퍼터를 이용한 NiFe/CoFe/AlO/CoFe/Ta TMR 소자 제작에 있어서의 자기저항 균일성 연구)

  • 이영민;송오성
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.5
    • /
    • pp.189-195
    • /
    • 2001
  • We prepared TMR junctions of NiFe(170 )/CoFe(48 )/Al(13 )-O/CoFe(500 )/Ta(50 ) structure on 2.5$\times$2.5 $\textrm{cm}^2$ area Si/SiO$_2$ substrates in order to investigate the uniformity of magnetoresistance(MR) value using a ICP magnetron sputter. Each layer was deposited by the ICP magnetron sputter and tunnel barrier was formed by the plasma oxidation method. We measured MR ratio and resistance of TMR devices with four-terminal probe system by applying external magnetic field. Although we used ICP sputter which is known as superior to make uniform films, the standard variation of MR ratio was 2.72. The variation was not dependent on the TMR devices location of a substrate. We found that MR ratio and spin-flip field (H's) increased as the resistance increased, which may be caused by local interface irregularity of the insulating layer. The variation of resistance value was 64.19 and MR ratio was 2.72, respectively. Our results imply that to improve the insulating layer fabrication process including annealing process to lessen interface modulation in order to mass produce the TMR devices.

  • PDF