• Title/Summary/Keyword: 편광측정

Search Result 405, Processing Time 0.039 seconds

Fiber-Optic Interleaving Filter Based on Polarization Beam Splitter and Fiber Coupler (편광 빔 분배기와 광섬유 결합기를 이용한 광섬유 인터리빙 필터)

  • Jang, Wook;Lee, Yong-Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.7-13
    • /
    • 2009
  • By incorporating a polarization beam splitter and fiber coupler, we propose a fiber-optic multiwavelength-switchable interleaving filter that can function as a polarizaiton-independent transmission or reflection-type one. The proposed filter consists of a polarizaiton beam splitter and a Sagnac birefringence loop that is composed of a 50:50 coupler, polarizaiton-maintaining fibers, and two quarter-wave plates. In the proposed filter, a transmission-type filter with a channel isolation > 18[dB] or a reflection-type one with a channel isolation ~3[dB], whose channel spacing and switching displacement were 0.8 and 0.4[nm] in common, respectively, could be obtained. Channel interleaving operation could be performed by the proper control of waveplates within the Sagnac birefringence loop.

Measurement of Isochromatic Fringe Distribution of a TV Glass Panel by Use of Photoelastic 4-step Phase Shifting Method (광탄성 4단계 위상이동법을 이용한 TV유리패널의 등색프린지 분포측정)

  • Baek, Tae-Hyun;Kim, Myung-Soo;Cho, Seong-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • This paper presents the experimental results measured by photoelastic 4-step phase shifting method for the isochromatic fringe distribution in a TV glass panel. In the conventional photoelastic method, the isochromatic fringe orders are measured manually point by point. The 4-step phase shifting method uses four images obtained from a circular polariscope by rotating the analyzer to $0^{\circ},\;45^{\circ},\;90^{\circ}$, and $135^{\circ}$. In order to use the 4-step phase shifting method, the elements of a polariscope should be aligned to isoclinic direction at a point and/or along a line where isochromatic fringe distribution is measured. Experimental results obtained from the 4-step phase shifting method are compared with those measured by the Senarmont compensation method. Both results are well agreed. Then, isochromatic fringe distributions in the TV glass panel that is heat-treated before and after are compared. Maximum and minimum isochromatic fringe orders in the TV glass panel with before- and after-heat treatment are changed approximately two times.

Fabrication and characterization of grating-assisted co-directional coupler wavelength filter in InP (좁은 파장대역폭을 갖는 격자도움형 방향성 결합기 필터의 제작과 특성측정)

  • 김덕봉;박찬용;김정수;이승원;오광룡;김흥만;편광의;윤태훈
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.2
    • /
    • pp.149-153
    • /
    • 1997
  • We demonstrate the operating characteristics(center wavelength, bandwidth, TE/TM polarization, tuning range) of grating-assisted co-directional coupler(GACC) filter fabricated with InGaAsP compound semiconductor. A design of waveguide structure has been focused on the narrow bandwidth characteristics of the filter. Reactive ion etching technique was employed for the uniform waveguide formation. The bandwidths(FWHM) and center wavelengths of the fabricated GACC filter were measured by 1.5 nm and 1530.6 nm for TE polarization and 1.3 nm and 1494.0 nm for TM polarization. This is the one of the narrowest bandwidth at 1530 nm region ever reported. The center wavelength shifted form 1530 nm to 1538 nm when the current of 100 mA was injected at 4.5 mm-long device. Good agreement between the designed and measured operating characteristics for some waveguide structures is demonstrated.

  • PDF

Polarization-independent temperature sensor using cladding layers of the overlay waveguide coupled with a side-polished fiber (측면 연마 광섬유와 결합된 상부 도파로의 클래딩을 이용한 편광 무의존 온도센서)

  • 손경락;김광택;송재원
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.6
    • /
    • pp.467-472
    • /
    • 2002
  • In this paper, we propose a polarization-insensitive temperature sensor using a thermo-optic effect of the upper and (or) lower cladding of a planar waveguide in contact with a side-polished fiber. A microscope cover glass with thickness of a 170 ${\mu}{\textrm}{m}$ is adopted as an overlay waveguide because this waveguide opposes sudden temperature change and ensures polarization-insensitive responses. The measured polarization-dependence loss is less than 0.3 dB. The temperature can be detected as a result of the shift in coupling wavelength of the sensor. We investigate the shift in coupling wavelength as a function of the temperature variation with respect to the different thermo-optic coefficients of lower and upper claddings. We also show that the temperature sensitivity of the device can be easily controlled by the thermo-optic coefficients of lower and upper claddings of the overlay waveguide.

Fiber Bragg grating sensor using polarization-maintaining fiber (편광 유지 광섬유를 이용한 Bragg Grating 센서 제작)

  • 김철진;박태상;이상배;최상삼;정해양
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.5
    • /
    • pp.415-419
    • /
    • 1997
  • A novel fiber optic sensor is demonstrated using a FBG in PM(Polarization-Maintaining) fiber. Gratings have been written in a Bow-Tie type fiber using the phase mask. The operation of the sensor simply involves monitoring back-reflected Bragg wavelengths from the grating. Since PM fiber has two principal semi-axes with two indices of refraction, two Bragg wavelengths were observed. We have observed the position of Bragg wavelengths for PM FBG shifted simultaneously by either applying the longitudinal strain or temperature change. The wavelength sensitivity of 1.2pm/$\mu$$\varepsilon$ about a longitudinal strain and the wavelength sensitivity of 11.4pm/$^{\circ}C$ about a temperature have been experimentally achieved. The wavelength sensitivity of both longitudinal strain and temperature are approximately same with the reported values for the single mode FBG. On the other hand, the change of separation between Bragg wavelengths was observed by the applying transverse stress. We observed that the separation between two Bragg wavelengths is proportional to the applied transverse stress. The wavelength sensitivity of 14.6 pm/N about a transverse stress has been achieved. We have demonstrated PM FBG sensors can measure the transverse stress independently from the effects of temperature.

  • PDF

A Study on Fabrication and Performance Evaluation of Ti:LiNbO3 Polarization Mode Controllers (Ti:LiNbO3 편광모드 조절기 제작 및 성능 평가에 관한 연구)

  • Moon, Je-Young;Jung, Hong-Sik
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.6
    • /
    • pp.547-554
    • /
    • 2004
  • We investigated a LiNbO$_3$ based integrated-optic polarization controller with the Ti-indiffused waveguide along the z-axis utilizing the electro-optic effect. The device consists of a first quarter-wave (λ / 4) followed by a half-wave (λ / 2) and a second quarter-wave (λ / 4) wave-plate. We analyzed the amount of phase change and the transformation of the polarized mode as a function of the combination of wave-plates and of their applied voltages. The operation has been systematically measured utilizing a polarimeter and Poincare sphere. We confirmed that the fabricated device controls the transformations from any arbitrary input state of polarization (SOP) into any general output SOP.

Measurement of Surfactant Concentration Using Light Scattering Method (광 산란방법을 이용한 계면활성제 농도측정)

  • Jo, Young Hyeon;Jo, Gyeong Hyeon;Jung, Chi Sup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.8
    • /
    • pp.441-448
    • /
    • 2017
  • A method for measuring the concentration of surfactant in water was developed. In this technique, microbubbles were used as light scatterers. The polarization change of light scattered by microbubbles was analyzed by Mueller matrix analysis. $M_{11}$, one of the Mueller matrix elements, was found to be a key parameter inferring the surfactant concentration within the concentration range of 0 ppm to 60 ppm. The best results for this measurement were obtained when the scattering angle was $150^{\circ}$ and the extinction ratio was 56.2. This experimental result shows that the EPLS can be effectively used as a real time inspection method for water quality monitoring in lakes or rivers.

Real-time Highly Sensitive Measurement of Myocardial Infarction Biomarkers Using Silicon-based Ellipsometric Biosensors (실리콘 기반 타원편광계식 바이오센서를 이용한 심근경색 생체표지자의 실시간 초고감도 진단 농도 측정)

  • Min, Yoon Gi;Cho, Hyun Mo;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.2
    • /
    • pp.59-66
    • /
    • 2019
  • We report highly sensitive detection of myocardial infarction biomarkers, such as myoglobin and cTnI, within several hundred seconds using a rotating-analyzer ellipsometer and a biosensor with biochips fabricated on a $SiO_2$-coated tilted silicon substrate. We choose the running buffer to be pure phosphate-buffered saline (PBS) or 10% mixed human serum. When we choose the running buffer to be pure PBS, we obtain diagnostic densities of pure myocardial infarction biomarkers of up to 1 ng/ml and 5 pg/ml respectively. Meanwhile, when we use PBS with 10% human serum, the measured densities of myoglobin and cTnI were up to 1 ng/mL and 1 pg/mL respectively. The measured diagnostic densities are less than 1/15 and 1/80 (in cases of myoglobin and cTnI respectively) of those referenced by the World Health Organization.

타원편광분석기를 이용한 Cd1-xMgxTe (0$\leq$x$\leq$0.5) alloy film의 유전율함수 연구

  • 구민상;이민수;김태중;김영동;박인규
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.83-83
    • /
    • 2000
  • MBE법으로 성장시킨 Cd1-xMgxTe 박막을 조성비 (x=0, 0.23, 0.32, 0.43)에 따라 타원편광 분석기로 측정하여 연구하였다. E0 critical point energy 아래에서 나타나는 간섭무늬를 제거하기 위해 multilayer calculation을 수행했고 ellipsometric data를 2번 미분하여 계산하는 Critical Point Parabolic Band(CPPB) model을 사용하여 E0, E0+Δ0, E1, E1,+Δ1, and E0'critical point energy 들을 구할 수 있었다. 특히 E2 peak region 에서는 종전의 고상시료 (bulk)에서 측정 발표된 값보다도 매우 높고 명확한 <$\varepsilon$2>값이 측정되어, E2와 E、0 peak가 명확하게 분리되는 것을 볼 수 있었다. 또한 Mg의 조성비에 따라 critical point energy 가 linear 하게 변화됨이 관측되었다.

  • PDF