• Title/Summary/Keyword: 펌프 제어

Search Result 553, Processing Time 0.031 seconds

Design of Heat Pump Renewable Energy System Using Wastewater with a Heat Source (폐수열 히트펌프 재생에너지 시스템 설계)

  • Choo, Yeon-Gyu;Kim, Bong-Gi;Kim, Sung-Du
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.787-790
    • /
    • 2011
  • 본 연구에서는 페수열 회수 보일러에서 버려지는 페수열을 재생하여 에너지를 재활용하기 위하여 퍼지제어 알고리즘을 사용한 지능제어기를 설계하고자 한다. 폐수유입온도의 변화와 폐수유입량의 변화를 파라미터로 하여 컴프레서의 정속운전 대수와 토출온수온도의 특성곡선을 전문가의 지식으로부터 얻을 수 있다. 폐수열 회수 보일러에 유입되는 폐수부하에 따른 컴프레서의 정속운전 대수를 최소화 하기위해 폐수유입온도와 유입량의 변화를 측정하여 최적의 정속운전 대수 및 인버터 운전량을 실시간으로 결정하는 지능제어기를 설계하여 페수열 부하의 변동을 실시간으로 추정하여 최소의 컴프레서 운전대수 및 조작량을 제어함으로써 에너지 효율과 경제성을 극대화할 수 있다.

  • PDF

Remote Control of Pumping System for Underground Water Pollution and Running Dry Prevention Using Ubiquitous (유비쿼터스를 이용한 지하수 오염과 고갈방지를 위한 펌핑시스템의 원격제어)

  • Tack, Han Ho
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.3
    • /
    • pp.9-15
    • /
    • 2013
  • This paper was development of remote controller of pumping system by using ubiquitous for underground water contamination prevention in the area of glasshouse facility. This paper automatically controls from to temperature and humidity for pumping sprinkler at water hanging cultivation. This prevents indiscreetive development of underground water, and prevents damage of environmental pollution without complementary measures in case of water lacked humble-void. The result of this research, confirms decrease of electrical fee, prevention of indiscreet underground water usage and its drying up thought optimum farm products management and pumping control system.

Fabrication and Characteristics of Thermopneumatic-Actuated Polydimethylsiloxane microfluidic systems (Lab-on-a-chip과 m-TAS를 위한 미세 유체 시스템)

  • Moon, Min-Chul;Kim, Ju-Ho;Kim, Jin-Ho;Kang, C.J.;Kim, Yong-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.2099-2101
    • /
    • 2004
  • 본 연구에서 제안하는 마이크로 시스템은 열공압 방식으로 구동되고 제작비용이 저렴한 indium tin oxide (ITO) 및 polydimethylsiloxane (PDMS)로 제작되었다. 제안된 마이크로 밸브와 마이크로 펌프의 구조는 ITO 히터, SU-8 층, PDMS membrane, 그리고 PDMS 채널로 구성 되어 있다. 제안된 마이크로 펌프와 마이크로 밸브는 제작 공정 및 구조가 간단하고 값이 저렴하며, 마이크로 펌프와 마이크로 밸브를 같은 기판 위에 쉽게 직접화할 수 있는 장점을 가진다. 마이크로 밸브의 유량은 채널 폭에 비례하며 밸브가 closing 되는 전력은 채널의 폭과 상관없이 100 mW이다. 마이크로밸브의 ITO 히터의 온-오프에 따라 유량이 매우 잘 제어되었다. 제안된 마이크로 펌프의 경우, 히터의 인가 펄스 전압이 증가함에 따라 유량은 선형적으로 비례 증가함을 관찰할 수 있다. 마이크로 펌프의 최대 유량은 펄스 전압과 duty 비가 55V와 10%일 때 6 Hz에서 78 nl/min이 측정 되었다.

  • PDF

The starting-up analysis of pump motor based on two power systems (상이한 전력공급계통에 의한 펌프모터 기동특성 분석)

  • Kim, Hee-Gon;Yoo, Taek-Su;Choi, Hyeong-Cheol;Lee, Hyeng-Muk;Choi, Jin-Suk;Jang, Seok-Myong
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.105_106
    • /
    • 2009
  • 본 논문은 가압펌프용 전동기에 대한 기동방법을 정류소자(Soft starter)에 의한 기동전류 제어방식을 채택하고 있는 수도사업장에서 한전 수전에 의한 펌프모터 기동시에는 원활하게 운전이 가능하였으나 비상용 디젤발전기 부하운전에서 펌프모터를 기동하는데 실패함에 따라 상이한 전력공급계통으로부터 펌프모터 기동시 콘덴서의 특이현상과 고조파의 영향에 따른 모터 기동특성을 비교분석한 사례를 중심으로 연구되었다.

  • PDF

Energy Saving Technique of Refrigeration Warehouse Cold Water Pump Using Photovoltaic Generation (태양광발전을 이용한 냉동.냉장창고용 냉수펌프의 에너지절감 기법)

  • Kim, Dae-Gyun;Jeon, Kee-Young;Lee, Sang-Chip;Chung, Choon-Byeong;Lee, Hoon-Goo;Han, Kyung-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.92-99
    • /
    • 2005
  • We are interaction refrigeration warehouse cold water pump system and photovoltaic generation system. At this time, a target pressure is able to control in spite of change of the pressure according to pump head and rate of flow of pump. Also, we carry out the vector control of BLDC motor with the maximum torque operation and a high reliability from territory of each operation speed. Therefore, in this paper, we conclude energy saving technique of refrigeration warehouse cold water pump system.

Waterhammer for the Intake Pumping Station with the Pump Control Valve (펌프제어밸브를 사용한 취수펌프장에서의 수격현상)

  • Kim, Kyung-Yup;Oh, Sang-Hyun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.4 s.13
    • /
    • pp.16-21
    • /
    • 2001
  • The field tests on the waterhammer were carried out for PalDang intake pumping station of the metropolitan water supply 5th stage project. The pumping station was equipped with the pump control valve as the main surge suppression device and the surge relief valve as auxiliary. However, the pump control valve had not been early controlled in the planned closing mode, and the slamming occurred to the valve which abruptly closed during the large reverse flow. Because the pressure wave caused by the pump failure was superposed on the slam surge, the upsurge increased so extremely that the shaft of the valve was damaged. It was desirable that the surge relief valve was installed in the pumping station or near the pump exit for the delay of response. After reforming the oil dashpot of the pump control valve, the sliming disappeared and the measured pressure was in fairly good agreement with the results of simulation. In case of three pumps for ${\phi}2,600$ pipeline being simultaneously tripped, the pressure head in the pumping station increased to 95.6 m, and the upsurge caused by the emergency stop of four pumps for ${\phi}2,800$ pipeline was 89.6m. We concluded that the pumping station acquired the safety and reliability for the pressure surge.

  • PDF

Control Algorithm Development for Design of Cooling System in High-power Propulsion Motor (대용량 전기추진시스템 설계를 위한 제어알고리즘 개발)

  • Oh, Jin-Seok;Jung, Sung-Young;Kong, Yeong-Kyung;Bin, Jae-Goo;Kim, Han-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.1
    • /
    • pp.195-201
    • /
    • 2010
  • In this paper, a cooling system of high-power propulsion motor with Energy Saving System(ESS) is described. Normally, the cooling system for ship consists of fresh water pump, sea water pump, 3-way valve and cooler. In the cooling system, F.W(Fresh Water) and S.W(Sea Water) pump is operated on rated rpm, and the 3-way valve is controlled for preventing over-cooling. So, the consumption power of pump's motor is changed according to a sea water temperature. In the proposed cooling system, F.W. pump and S.W pump is controlled by inverter, and it is can be reduced the consumption power. Also, it is proved with simulation.

Development of optimum pump operation technique for the damage rate reduction of water distribution system (상수도관망의 피해율 저감을 위한 가압장 최적운영기법 개발)

  • Kwon, Hyuk Jae
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.5
    • /
    • pp.373-380
    • /
    • 2019
  • In this study, the optimum pump operation technique is suggested to decrease the damage rate of water distribution system. Pump operation system was developed to achieve the effective pump operation. Pressure sensors which can communicate with pumps are installed at the end of water distribution system. Pump operation system can control the pressure of water pump according to data sent from the pressure sensors. Therefore, water distribution system can reduce the pressure and maintain enough pressure which can supply the demand of water users. For proving effectiveness of new system, reliability model was introduced to compare the results of damage rates between the maintaining high pressure and selective pressure in water pump. Unsteady analysis was conducted with several scenarios. And the results were used to calculate the probability of pipe breakage. From the results, it was found that new pump operation system can reduce the energy usage and probability of pipe breakage by applying to pumps.

A Low Noise Phase Locked Loop with Cain-boosting Charge Pump (Cain-boosting 전하펌프를 이용한 저잡음 위상고정루프)

  • Choi Young-Shig;Han Dae-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.2
    • /
    • pp.301-306
    • /
    • 2005
  • In this paper, a gain-boosting charge pump(CP) and a latch type voltage controlled oscillato.(VCO) with voltage controlled resistor(VCR) were proposed. The gain-boosting CP achieves good .current matching of less than 11$mu$V voltage difference between 43$mu$V and 32$mu$V in its output range from 0.8V to 2.3V. The VCO with VCR shows good linear characteristics over the range from 1V to 3V. The fabricated VCO exhibits -108dBc/Hz phase noise at a 100kHz and is comparable to that of the integrated LC-tank oscillator. The phase locked loop(PLL) with new circuits was simulated in a 0.35$mu$m CMOS process and showed 150$mu$s locking time.