• Title/Summary/Keyword: 펌프 성능

Search Result 1,416, Processing Time 0.028 seconds

Performance of Airlift Pumps for Water Circulation and Aeration (물 순환 및 에어레이션용 에어리프트 펌프의 성능)

  • OH Se-Kyung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.25 no.6
    • /
    • pp.529-537
    • /
    • 1992
  • Airlift pumps were tested to evaluate their pumping and aeration capacities. The pumps were 34.5 inch long made of 2, 3, 4 and 6 inch nominal diameter PVC pipes. An one hp air blower was used to supply the air. The air-flow rate was measured by an anemometer type air-flow meter and air pressure was level changes in a water tank from which water was pumped. Aeration by the pumps was tested by the standard aeration test method with the center of pump outlet positioned 3 inches above water surface. Oxygen concentrations in water were measured to determine aeration rate. As pumping head increased by water level draw-down in the tank water flow decreased while air flow increased. The reduction rate of water flow was higher with 4 and 6-inch pumps. Small pumps showed very minor changes in the reduction. Aeration rates were similar among 3, 4, and 6 inch pumps. With one hp air blower 6-inch pump at the minimum pumping head achieved the best performance in terms of water circulation.

  • PDF

Consideration on the performance test procedure of a turbomolecular pump and a compound molecular pump (터보분자펌프 및 복합분자펌프의 성능시험절차에 대한 고찰)

  • 인상렬;박미영
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.3
    • /
    • pp.303-311
    • /
    • 2001
  • The pumping speed and the maximum compression ratio as well as the critical backing pressure as main parameters representing normal and limiting performance of a turbomolecular pump and a compound molecular pump were measured basing on a draft KS of the acceptance test procedure. Characteristics of the molecular pumps of two different kinds were compared and some points for improving regulations of the test procedure were proposed.

  • PDF

탈설계점에서 원심펌프 성능예측 개선을 위한 연구

  • 정장규;김은기;고용상;박병호;고득윤
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.154-159
    • /
    • 1996
  • 원자력발전소에는 원자로냉각재펌프와 같이 원심펌프가 많이 쓰이고 대부분의 펌프가 탈설계점에서 운전되고 있다. 이러한 펌프의 성능을 예측하거나 개선하고자 할 때 성능해석코드는 매우 유용하다. 본 연구에서는 기존성능해석프로그램의 문제점인 탈설계점에서의 성능예측 정확도가 많이 떨어지는 점을 개선하고 기존해석방법론을 검토하여 유량변화에 관계없이 일정한 값을 갖는 Slip factor의 문제점을 보안, 유량에 따라 적절히 보상하는 Slip factor를 고려하였고 각종 손실구조 및 적절한 손실모델을 도출하여 새로운 프로그램을 개발하였다. 또한 이 프로그램을 이용한 계산결과를 실험자료 및 기존의 상용코드 해석결과와 비교한 결과, 극저유량운전범위를 제외하고는 전유량 범위에 걸쳐 매우 양호한 결과를 얻었다.

  • PDF

Experimental study on the performance of heat pump system using $CO_2$ (이산화탄소용 열펌프시스템의 성능특성에 관한 실험적 연구)

  • Jang, Seong-Il;Jeon, Min-Ju;Yu, Tae-Guen;Son, Chang-Hyo;Oh, Hoo-Kyu
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.55-56
    • /
    • 2006
  • 냉매 충전량과 이차유체의 입구조건은 $CO_2$용 열펌프시스템의 성능실험에서 중요한 제어변수이다. 따라서, 열펌프사이클의 적용과 난방성능 향상을 위해 제어변수의 특성을 조사하는 것이 필요하다. 본 논문에서, $CO_2$용 열펌프 사이클의 성능 실험은 여러 가지 냉매 충전량에서 이차유체 입구조건에 변화를 주어 수행 되었다. 실험결과, 난방COP는 냉매 충전량이 증가함에 따라 1158g의 냉매 충전량에서 최대가 되었다가 감소하는 경향이 나타나며, 이는 COP가 최대가 되는 냉매충전량이 존재함을 나타낸다. 또한, 난방성능은 가스쿨러내 이차유체의 질량유량의 증가에 따라 증가하였다. 가스냉각기내 2차유체의 입구은도가 $10^{\circ}C$에서 $40^{\circ}C$로 증가하면, 난방용량, 압축일량, 토출압력은 각각 -8.57%, -35.89%, 32.78%로 변화했으며, 증발기 2차유체의 입구 온도가 감소하였을 때 난방COP는 감소하는 경향을 보였다.

  • PDF

Capacity Modulation of a Ground Source Multi-Heat Pump in the Part Load Condtions (축열형 지열원 냉난방 시스템의 단기 성능 특성 연구)

  • Kim, Namtae;Cho, Chanyong;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.119-119
    • /
    • 2010
  • 무한 지속 가능한 지열 에너지를 활용한 공조시스템인 지열원 냉난방 시스템은 기존의 공조 시스템보다 열원이 안정적이기 때문에 높은 효율과 우수한 성능을 가지므로, 기후변화협약 대응의 주요수단으로서 기술개발과 보급이 증대되고 있다. 본 연구에서는 대수층 축열 지열원 열펌프 시스템에 대한 실증 연구를 통하여 대수층 축열 지열원 열펌프 시스템의 하절기 냉방 성능을 분석하였다. 대수층 축열 냉난방 시스템은 주입정과 양수정의 2개의 우물공이 설치되어 있으며, 겨울 난방 운전 중에 한 개의 우물공으로부터 지하수를 열펌프로 유입한 후 낮은 온도의 지하수를 타 우물공에 축열하고, 하절기에 겨울에 저온으로 축열된 우물공으로부터 지하수를 열펌프로 유입하여 온도가 증가된 지하수를 타 우물공에 주입한다. 즉, 계절별로 열펌프에서 생성된 냉수와 온수의 대수층 축열을 위하여 계절별로 주입정과 양수정이 바뀌게 된다. 본 연구의 대수층 축열 지열원 열펌프 시스템의 2009년 8월의 주요일자별 시스템 운전 중의 평균 냉방 열펌프 유닛 COP와 냉방 시스템 COP는 각각 4.7과 3.4이상의 우수한 성능을 나타냈다. 또한, 모든 일자에 대하여 외기온도가 $31.6^{\circ}C$$22^{\circ}C$까지 변화가 크게 나타났지만 열펌프 유닛 COP와 시스템 COP의 변화는 미소하였다. 이는 양수정으로부터의 지중 순환수가 운전기간 중에 $17.5^{\circ}C$로 일정하게 유지되었기 때문이다. 양수정과 주입정 사이에 5개의 관측공을 설치하였으며, 양수정 측에 인접한 관측공의 온도는 거의 변화가 없었으며, 단기간이지만 널리 사용되고 있는 수직밀폐형 시스템과 달리 지속적인 냉방운전 중의 양수 온도의 증가는 발생하지 않아 안정적인 성능을 나타냈다. 주입정에 인접한 모니터링 홀의 온도는 심도가 깊은 곳의 온도가 낮은 곳보다 높게 나타났다. 이는 냉방 운전 시 열펌프 유닛의 실외열교환기에서 지중 순환수가 냉매로부터 열을 취득하여 온도가 상승하면서 주입정측에 온열이 축열이 진행되었기 때문으로 분석되며, 하절기의 냉방 운전 시간이 증가할 경우 축열 효과는 더욱 증가할 것으로 예상된다. 양수정과 주입정 중간의 모니터링 홀의 온도는 2009년 8월 가동 중에 온도변화는 없었는데, 이는 양수정과 주입정 사이의 열간섭이 발생하지 않았기 때문으로 분석된다. 일자별로 운전 중의 열펌프 유닛 COP는 차이가 없었지만, 운전 및 정지 시간을 모두 포함한 시스템 소비전력과 냉방용량을 모두 합산하여 산정한 일일 평균 냉방 열펌프 유닛 COP와 냉방 시스템 COP는 일자별로 다소 차이가 발생하였는데, 이는 각 일자별로 열펌프 유닛 가동율의 차이로 인하여 열펌프 유닛 가동 전에 먼저 작동되는 지중순환펌프의 운전 소비전력의 차이와 열펌프의 단속운전 시의 열손실과 추거 소비전력의 차이 때문이다.

  • PDF

Hot-Fire Test of a Turbopump for a 30 Ton Class Engine in Real Propellant Environment (30톤급 엔진용 터보펌프 실매질 고온시험)

  • Hong, Soon-Sam;Kim, Jin-Sun;Kim, Dae-Jin;Kim, Jin-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.11-17
    • /
    • 2009
  • Hot-fire test of a turbopump for a gas generator cycle rocket engine of 30 ton class was carried out in real propellant environment. Liquid oxygen and kerosene were used for the oxidizer pump and the fuel pump, respectively, while hot gas produced by the gas generator was supplied to the turbine. A part of the propellant discharged from the pumps was provided to the gas generator. The turbopump was run stably at both on-design and off-design conditions, satisfying all the performance requirements. This paper describes one of the test cases, where the turbopump was run for 120 seconds at three different operating modes in one test. In terms of performance characteristics of pumps and turbine, the results from turbopump assembly test using real propellant showed a good agreement with those from the turbopump component tests using simulant working fluid.

  • PDF

Analysis of vortex generation tendency around the pump suction using three dimentional numerical model (3차원 수치모형을 이용한 펌프 흡입부 주변의 와류 발생 경향 분석)

  • Byun, Hyun Hyuk;Yang, Jae Hoon;Yoon, Byung Man
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.103-103
    • /
    • 2016
  • 최근 기후변화에 따른 집중호우로 도시홍수의 피해가 급격히 증가하고 있다. 특히 인구가 밀집하고 교통량이 많은 대도시의 경우 동일한 호우에 대하여 녹지나 농경지 등에 비해 그 피해가 더 심각하다. 일반적으로 홍수 피해의 직접원인은 외수로 인한 피해와 내수로 인한 피해로 크게 구분할 수 있다. 외수피해는 주로 소하천 및 지천의 범람, 제방의 붕괴 등으로 발생한 것이며 내수피해는 배수로, 하수도 및 펌프장의 내수배제능력 부족이 주된 원인이다. 따라서 도시홍수를 효과적으로 방어하기 위해서는 우선적으로 내배수시설의 성능개선이 선행되어야 할 필요가 있다. 이러한 내배수 시설의 성능 개선을 위해서는 현재 기 설치되어 있는 빗물펌프장의 설계 및 내배수 효율에 대한 성능평가가 필요하다. 하지만 현재 국내 펌프설계기준에는 빗물펌프장의 설계 및 운영에 대한 구체적인 성능 평가 방법이 제시되어 있지 않은 실정이다. 만약, 펌프 흡입수조 및 흡입파이프의 형상이 적절하게 설계되지 못한다면 물이 파이프 입구로 부드럽게 흡입되지 못하고 볼텍스 및 스월이 발생하게 된다. 이러한 볼텍스 및 스월은 펌프 입구 쪽으로 물 뿐 아니라 공기를 함께 흡입시킴으로써 펌프의 효율저하, 소음, 진동을 발생시키며 펌프 파손의 원인이 될 수 있다. 따라서 펌프를 설치하기 전 펌프 설치 후에 발생되는 펌프 흡입부 주변의 흐름특성 변화 및 흐름특성이 구조물에 미치는 영향 등을 고려하기 위하여 수리모형실험이 필요한데, 수리모형실험은 많은 시간과 비용이 들어가기 때문에 이를 대체할 수 있는 방안이 요구된다. 그런 이유로 최근에는 수리모형실험 대신 수치모의를 이용하는 경우가 많다. 수치모의의 결과는 수리실험의 결과와 비교, 검증을 거쳐 신뢰성을 얻는다. 본 연구에서는, 3차원 수치모형의 다양한 난류모델을 이용하여 흡입파이프로 물이 유입될 때 흡입부 내, 외의 수심 별 유속 변화를 분석하고, 그 결과를 이용하여 FLOW 3D 모형의 검증을 수행하였다.

  • PDF

건식진공펌프 개발 국내외 동향

  • No, Myeong-Geun;Hwang, Tae-Gyeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.91-91
    • /
    • 2012
  • 반도체 및 디스플레이 산업분야 뿐만 아니라 일반 산업분야에도 건식진공펌프의 사용이 보편화됨에 따라 펌핑 성능은 물론 펌프의 특성 역시 중요한 요소로 떠오르고 있다. 건식진공펌프의 두 축을 이루어 온 다단루츠형과 스크류형 진공펌프는 각각 고유의 장단점에 바탕하여 응용분야에 따라 선호되며 기술적으로 발전하여 왔다. 최근 반도체 및 디스플레이 분야에서 사용되는 건식진공펌프들은 작은 크기, 큰 펌핑성능, 높은 신뢰성 및 낮은 소비전력 등과 같이 서로 동시에 실현되기 어려운 특성들을 요구받고 있다. 더욱이 에너지 효율에 대한 중요성이 획기적으로 증대되어 제품개발 과정에서 최우선적으로 고려되어야 할 사항으로 부상하였다. 본 발표에서는 이러한 시장의 요구를 충족시키기 위한 국내외 건식진공펌프 업체들의 접근 방향과 향후 발전 방향에 대하여 살펴보았다.

  • PDF

Fabrication and Vacuum Performance Test of the NEG Pump for $10^{-9}$ Pa Chamber ($10^{-9}$ Pa대 용기를 위한 NEG 펌프 제작 및 진공성능 조사)

  • 박미영;인상렬
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.3
    • /
    • pp.312-320
    • /
    • 2001
  • A Non-Evaporable Getter(NEG) pump was fabricated using Zr-V-Fe alloy modules to obtain $10^{-9}$ Pa range pressures. Pumping performances and activation characteristics were investigated and the pumping speeds for hydrogen, deuterium and carbon monoxide gases of the NEG pump were measured. And hydrogen desorption characteristics were examined during activation at $450^{\circ}C$. Futhermore the vacuum performance was compared with those of other high vacuum pumps as turbo-molecular pump, sputter-ion pump, and cryo pump by analyzing the residual gases of the system.

  • PDF

Cryogenic Performance Test of a Turbopump Inducer (터보펌프 인듀서에 대한 극저온 성능시험)

  • Kim, Jin-Sun;Kim, Jin-Han;Hong, Soon-Sam
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.1
    • /
    • pp.64-70
    • /
    • 2007
  • A test facility was developed where an inducer for a liquid rocket engine turbopump can be tested using liquid nitrogen as a working fluid. At the facility, a hydrodynamic performance test and a cavitation performance test for an oxidizer turbopump were carried out. Head-flow relation at liquid nitrogen test was similar to the case at water test. However, cavitation performance at the liquid nitrogen was superior to the case at water test, which results from the thermodynamic effect of cavitation.