• 제목/요약/키워드: 펄스폭 변조제어

검색결과 139건 처리시간 0.033초

수중운동체의 심도제어를 위한 제어기 설계 (Controller design for depth control of vehicle under seawater)

  • 윤강섭;박경철
    • 대한기계학회논문집A
    • /
    • 제20권1호
    • /
    • pp.24-34
    • /
    • 1996
  • In ordaer to hold an underwater vehicle at a certain depth, buoyancy that acts on the underwater vehicle can be modulated. In this research, buoyancy that could control depth of underwater vehicle is generated by a buoyancy bag. Solenoid valves are operated by pulse with modulation(PWM) method. State equation, in consideration of the volume of buoyancy bag, pressure inside bag, and dynamic of the underwater vehicle, is derived. This system is very unstable, inculdes modelling error and nonlinearity. In depth control system, maintanance of performance is required., anainst vatiation of systerm parameter and operating depth, and designed. Through the computer simulation, performance is comparerd for each controllers.

  • PDF

CMOS OTA를 이용한 펄스폭 변조회로 (A Pulse With Modulation Circuit using CMOS OTA)

  • 이은진;김희준;정원섭
    • 전자공학회논문지SC
    • /
    • 제41권5호
    • /
    • pp.43-48
    • /
    • 2004
  • CMOS OTA를 이용한 PWM 회로를 제안하였다. 제안된 회로는 발진주파수가 공급전압 및 온도에 대한 의존성을 배제할 수 있고, OTA의 바이어스 전류에 의해 주파수를 선형적으로 제어할 수 있다는 특징을 갖는다. H-SPICE 시뮬레이션을 통하여 제안된 회로의 동작의 타당성을 입증하였고 0.35㎛ CMOS 공정에 의한 layout 결과도 함께 제시하였다.

MR유체 스풀을 이용한 온-오프 밸브의 PWM제어 (PWM Control of On-Off Valves using MR Fluid Spool)

  • 양택주;배형섭;박명관
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1709-1712
    • /
    • 2003
  • Almost the on-off type solenoid valve is used to hydraulic system. It has a strong point that concerned about rapid response, electric and hydraulic characteristic at the same time. In this paper we produced the new type spool using the MR fluid different from the others. Also we controlled a cylinder position through PWM method. And using the AMESim software, We compared our new type spool valve with existed one from data of simulation and experiment.

  • PDF

개폐식 밸브를 사용한 공기압 서보 시스템의 효율적 밸브 개폐 방법에 관한 연구 (Study on the Effective Operating Method of on-off Valves for a Pneumatic Servo System)

  • 황웅태;최서호;이정오
    • 한국정밀공학회지
    • /
    • 제15권1호
    • /
    • pp.109-116
    • /
    • 1998
  • This paper is concerned with effective operating method of pneumatic on-off valves for improving position control accuracy, valve life-time and position settling time using modified pulse width modulation with dead-zone (MPWMD). The pneumatic system using on-off valves has advantage of simple construction and low cost compared with a system with servo-valves. The performance of the proposed control method is investigated experimentally for the position control of a pneumatic cylinder using on-off valves. Experimental results show that the proposed algorithm for valve operation can be used to obtain fast and accurate position control compared to the conventional PWMD algorithm. It is also shown that the use of the proposed MPWMD algorithm for the position control significantly reduces the number of valve switching and noise.

  • PDF

고주파수 PWM 제어를 이용한 ABS의 특성 평가에 관한 연구 (A Study on Estimating Characteristics of ABS Using High Frequency PWM Control)

  • 김병우;이용주;박호
    • 한국공작기계학회논문집
    • /
    • 제13권2호
    • /
    • pp.69-74
    • /
    • 2004
  • In general the surge pressure generated in hydraulic systems causes noise, vibration and odd effect to the system. To reduce the surge pressure, high frequency PWM control of 20KHz was attempted. To estimate the braking noise caused by surge, a vehicle equipped with on-board ABS hydraulic modulator has been experimented with respect to the various breaking condition. Thorough this experiments, it was found that breaking noise has been reduced using high frequency PWM control method compare with low frequency method. To evaluate high frequency control m practice, including verification of general functionality, EMI tests was experimented. Its was found that it is necessary to have the solution to electromagnetic interference(EMI) generated by switching elements.

파워시프트 변속기 유압시스템의 PWM 제어 실험 연구 (Experimental Investigation on PWM control of Power-shift Transmission Hydraulic System)

  • 김대철;이재규;강영선;이재천
    • 유공압시스템학회논문집
    • /
    • 제6권3호
    • /
    • pp.10-15
    • /
    • 2009
  • The major system of an agricultural power-shift tractor is the transmission, using power-shift. Because the transmission performance depends on the hydraulic control system, the most important aspect of the optimization is the design of the hydraulic control system. This study was conducted to improve a pressure modulation characteristics of the power-shift transmission hydraulic system. It has been tried to replace an existing pressure modulation method with a digital control by using HSSV(High Speed Solenoid Valve). The performance of the PWM control system in power-shift hydraulic transmission has been evaluated by means of experiment.

  • PDF

인버터를 이용한 냉동용 압축기의 용량 제어 (Control of Refrigerating Compressor Capacity Using Inverter)

  • 양현석;김환성;김정훈;김상봉;김종수
    • 설비공학논문집
    • /
    • 제5권2호
    • /
    • pp.94-101
    • /
    • 1993
  • Recently, efforts of decreasing energy consumption are continously increased and user's preference is also diversified in refrigeration and air conditioning systems. Thus, in order to satisfy these demands, high efficiency, high intelligence, and energy saving for those systems are essential. As the basic study for diverse functions and intelligence of those systems, we investigated the response characteristics through the compressor capacity control concerned with superheat and refrigeration room temperature. And, response characteristics are investigated experimentally by using micro computer based PWM inverter control method. Experimental result of the conventional on-off control method is given in order to be compared to the results of inverter control method. The results obtained through this study are summarized as follows. It is shown from the experimental results of the on-off control method that the range of temperature variation around the steady state ($-18^{\circ}C$) is very large (about $7{\sim}8^{\circ}C$) and the settling time bringing the steady state is not found. In the inverter control method, we can see that the refrigeration room temperature after reaching the setting temperature is very stable without fluctuation and a robust control for disturbance such as opening the door has been realized.

  • PDF

DC 모터의 센서리스 속도제어 및 그 응용에 관한연구 (A Study on the Sensorless Speed Control and Its Application of DC Motor)

  • 하윤수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권3호
    • /
    • pp.292-299
    • /
    • 1999
  • DC motors are widely used in many industrial fields as the actuator of the robot and the driving power motors of the electrical vehicle, Usually in the sensors of DC motors such as the encoder the tachogenerator and the potentiometer etc. are applied, But usage of these sensors results in the increased price and operating cost such that the application of the motors are limitted. To solve this problem another method to construct low cost control system is investigates. In this paper a new speed control method for DC motor is proposed. This method uses motor parameters instead of using speed or position sensors. In this way the angular velocity is estimated by the measure-ment values of the armature voltage and current instead of measuring the sensor signal. This paper presents an alorithm for estimating the angular velocity of DC motor The effectiveness of the proposed method is verified by experimental results. Also the applicability of the proposed method is presented by applying to the velocity contol of a wheeled mobile robot.

  • PDF

전압모드 PWM DC/DC 전력 컨버터 설계연구 (A Study on the Design of Voltage Mode PWM DC/DC Power Converter)

  • 노영환
    • 한국철도학회논문집
    • /
    • 제14권5호
    • /
    • pp.411-415
    • /
    • 2011
  • DC/DC컨버터는 임의의 직류전원을 부하가 요구하는 형태의 직류전원으로 변환시키는 전력변환기이다. 전압모드 DC/DC 컨버터는 주기적으로 입력측에서 출력측으로 전달되는 에너지를 제어하는 기능을 수행하기 위해 MOSFET(산화물-반도체 전계 효과 트랜지스터), 인덕터, PWM 제어기(오실레이터, 연산증폭기, 비교기로 구성)를 이용한다. 본 논문에서 PWM(펄스폭 변조) 모듈과 스위칭모드로 제어하는 기본적인 승압과 강압컨버터를 연구하고, 전기적 특성을 SPICE로 시뮬레이션을 수행하며, 전력의 효율을 각 소자의 변화와 사양에 따라 분석하는데 있다.

비례제어밸브용 디지털 앰프.컨트롤러에 대한 연구 (A Study on a Digital Amplifier.Controller for Proportional Control Valve)

  • 이재천;고재욱;권태황;신행봉
    • 유공압시스템학회논문집
    • /
    • 제8권1호
    • /
    • pp.19-25
    • /
    • 2011
  • This study presents the design of digital amplifier.controller for a proportional control valve and the development of PID discrete control scheme by using RCP(Rapid Controller Prototyping) system. RCP system is the device to embed the control code developed in PC into the microcontroller on-site. Ramp input test using the digital amplifier.controller developed in this study was carried out for the proportional control valve of domestic production and Bosch Rexroth respectively. The instability problem occurred around maximum displacement of localized valve spool at ramp input test was solved by supplementing offset current to the duty ratio of PWM(Pulse Width Modulation) driving signal to the solenoid. The comparison of test results between localized proportional control valve and Bosch Rexroth's product shows that the characteristics obtained by ramp input test and static flow gains are alike each other. Two valves are about the same in dead bands and hysteresis characteristics.