• Title/Summary/Keyword: 팬환기

Search Result 147, Processing Time 0.029 seconds

An appropriateness review on the road tunnel ventilation standards by pollutants site measurement and case study (오염물질 현장측정 및 사례조사를 통한 도로터널 환기기준의 적정성에 관한 연구)

  • Kim, Hyo-Gyu;Baek, Doo-San;Yoo, Ji-Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.3
    • /
    • pp.323-335
    • /
    • 2020
  • In this study, a series of site measurement of particulate and gases pollutants at five tunnels were carried out along with case studies to review the suitability of the current road tunnel ventilation design standards. Previous studies by other researchers have shown that the ratios of the level of measurement to the standard were 27.9%, 1.6% and 3.4% for TSP, CO and NOx, respectively. Those measured in this site study shows even lower ratios; the ratios were 2.6%, 0.8% and 0.3%, for TSP, CO and NOx, respectively. The particle size analysis of TSP for the five tunnels shows that PM10 including tire wear and re-suspended road dust exceeded 20.4%. This implies that non-exhaust particulate matter must be taken into account, since the current design standards for the particulate matter (visibility) include only the engine emission. Based on the recent research results, for vehicle emission rate and slope-speed correction factors, revision of ventilation design standards for pollutants is required. WRA (PIARC) also emphasizes the necessity of the ventilation design standards for pollutants. In addition, enactment of a new road tunnel ventilation system operation standard or guideline is strongly recommended when considering the low operating rate of the ventilation system with jet-fans.

A study on the calculation method for the number of vehicles in queue to determine the fire ventilation capacity in road tunnels - forced on the effect of queue length (도로터널의 제연용량 산정을 위한 정체차량대수 산정기법에 관한 연구 - 정체길이를 중심으로)

  • Yoo, Yong-Ho;Kim, Hyo-Gyu;Ryu, Ji-Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.1
    • /
    • pp.41-52
    • /
    • 2016
  • When the queue length of congestion vehicles in tunnel fire is extended beyond tunnel length, the capacity of smoke control system needs to be increased in line with ventilation resistance. However, the vehicle queue length is not defined, so a rational equation is necessary in current fire prevention guideline. This study is intended to propose an equation to calculate the queue length considering the number of vehicles in queue in tunnel fire and evaluate the applicability by tunnel length as well. When it comes to normal tunnel, it is necessary to compare the vehicle queue length with tunnel length up to the length of 1,200 m in a bid to avoid applying the vehicle queue length excessively in case of fire. As a result of evaluation of applicability to model a tunnel, saving the number of jet fan for smoke control appeared to be effective. Besides, quantitative approach to explain the vehicle queue length through the relationship between the percentage of large vehicles and tunnel length was presented. Consequently, when the queue length of the congestion vehicles exceeds the tunnel length in determining the capacity of smoke control system in case of fire, the number of vehicles beyond the tunnel length needs to be excluded from estimating the ventilation resistance by vehicles.

Experimental Study on Flow Direction of Fire Smoke in DC Electric Fields (DC 전기장 내에서 발생하는 화재연기 진행 방향에 대한 실험적 연구)

  • Park, Juwon;Kim, Youngmin;Seong, Seung Hun;Park, Sanghwan;Kim, Ji Hwan;Chung, Yongho;Yoon, Sung Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.5
    • /
    • pp.675-682
    • /
    • 2021
  • Fire accidents on land and at sea can cause serious casualties; specifically, owing to the nature of marine plants and ships, the mortality rate at sea from suffocation in confined spaces is significantly higher than that on land. To prevent such cases of asphyxiation, it is essential to install ventilation fans that can outwardly direct these toxic gases from fires; however, considering the scale of marine fires, the installation of large ventilation fans is not easy owing to the nature of marine structures. Therefore, in this study, we developed a new concept for fire safety technology to control toxic gases generated by fires from applied direct current (DC) electric fields. In the event of a fire, most flames contain large numbers of positive and negative charges from chemi-ionization, which generates an "ionic wind" by Lorentz forces through the applied electric fields. Using these ionic winds, an experimental study was performed to artificially control the fire smoke caused by burning paper and styrofoam, which are commonly used as insulation materials in general buildings and ships. The experiments showed that a fire smoke could be artificially controlled by applying a DC voltage in excess of ±5 kV and that relatively effective control was possible by applying a negative voltage rather than a positive voltage.

The Jet-fan Model Test for a Road Tunnel Ventilation (도로터널 제트팬 모형 실험)

  • Ryu, Jae-Hong;Yoo, Young-Ho;Kim, Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.8
    • /
    • pp.630-640
    • /
    • 2003
  • As tunnel ventilation has recently been playing a major role in the tunnel construction and maintenance, longitudinal ventilation systems with jet fans have been utilized a great deal because they are economical and effective. However, due to the length of tunnels and heavy traffic, it is hard to take the field measurements. In this study, therefore, the computer simulation and the model experiment of producing a wind tunnel were carried out simultaneously and the results were compared. The ultimate objective of this research was to interpret the air flow pattern inside the tunnel with a jet-fan was set up, and to offer the useful data for jet-fan installation and operation. The experiment was carried out with varying the jet-fan diameters, location of installation, the discharge velocity. Result showed that as the initial static pressure came up with the negative pressure, the tunnel air flowed into the inside of tunnel from outside due to the entrainment-effect and the backflow-phenomenon by separation-effect was observed in the lower half part of the tunnel. As the jet-fan was getting closer to the tunnel wall, the entrainment-effect caused by the interaction with the wall was increased; however, the mixing distance and irregular flow section became longer, and also the air pressure loss generated by wall friction was large.

A Study on cooling technology of electronics communication device consoles using heat pipe exchangers (히트파이프 열교환기를 이용한 전자통신장비 콘솔의 냉각 기술에 관한 연구)

  • Choi, Jee-Hoon;Ryoo, Seong-Ryoul;Sung, Byung-Ho;Lee, Jung-Hwan;Kim, Jong-Man;Chun, Ji-Hwan;Suh, Myung-Won;Kim, Chul-Ju
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.483-486
    • /
    • 2006
  • The fan is widely used to cool high heat flux generated as of the electronic communication device consoles. It, however, makes a lot of noises that interfere considerably with the operation environment. This study was conducted to obtain the cooling design technology of the consoles through being equipped with the Heat Pipe Heat Exchangers (HPHE) together with low revolution fans in place of existing fans for the cooling technology of the forced convection. Not only the sealed type consoles but the HPHE were also designed so as to cool effectively the heat generated from the inside of the console. The simulation was conducted by computational numerical analysis along with its experiments. The results of the numerical analysis and experiments were compared in order to improve the cooling technology of the consoles mounted with the HPHE. Consequently, instead of loud fan noise generated as of existing forced convection methods, the cooling technology of HPHE can remarkably improve many problems such as the operation environment, indoor dust, malfunction caused by pollution sources and so on.

  • PDF

Analysis of the Effects of Vests with Fan in Summer Environments (여름철 환경에서 팬이 있는 조끼의 인체 착용 효과)

  • Eom, Ran-i;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.43 no.6
    • /
    • pp.856-865
    • /
    • 2019
  • This study analyzed the effect of wearing a vest with an attached electric fan. Korean men in their 20s were given test "fan vests" equipped with fans on the chest, stomach, upper back, or lower back to wear. Participants wore them in a climate chamber set to replicate a summer environment (30±3℃, 75±1%RH, 0.2 m/sec). Subjective sensations and surface temperatures were measured. The attached fan on the front of the vest lowered the temperature of the vest and the skin surface where the fan was positioned, regardless of whether the wearer engaged in exercise. However, a fan attached to the lower back of the vest was effective in lowering the lower back of the vest as well as the upper back, back of the arm, and back of the neck. In addition, subjective evaluations indicated that a vest with fans attached to the stomach and lower back provided a cool sensation. However, it was confirmed that the design of an auxiliary tool capable of dispersing the weight is necessary since the weight of the fans can interfere with the comfort of wearing the vest.

Characteristics of Temperature Distribution of Pen for Exhaust Fan of Ventilation System (돈사용 환기팬을 위한 돈사 내 온도 분포 특성)

  • Kim, Hyeon-Tae;Kim, Woong
    • Journal of Animal Environmental Science
    • /
    • v.20 no.4
    • /
    • pp.155-160
    • /
    • 2014
  • This study was researched for use by data for the improvement of ventilation system of optimum environmental control systems. The ventilation system for windowless swine housing was installed negative pressure system that circular pipe duct for inlet was installed on the ceiling and axial flow fan for exhaust was installed on the sidewall. The temperatures in the pen was measured using infrared thermography camera and thermocouple with data-logger. The temperature measurement points was selected by infrared thermography camera is alley (G), inlet (A), front-upper (B), front-lower (C), rear-upper (D), rear-lower (E), forward fan (F). The temperature measured at those selected points for temperature distribution was $28^{\circ}C$ that was maintained setting temperature in suitably. The temperature deviations of F point and A~E points in windowless swine housing was less then average $0.5^{\circ}C$. The result of air velocity of measured points was suitable to the breeding of pigs.

An Experimental Study on the Aerodynamic Characteristics of the Robust Optimized Shape of Pantograph Panhead (팬터그래프 팬헤드 강건최적형상에 대한 공기역학적 특성에 관한 실험적 연구)

  • Rho, Joo-Hyun;Kwak, Min-Ho;Park, Hoon-Il;Lee, Young-Bin;Lee, Dong-Ho;Cho, Hwan-Kee
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.2224-2229
    • /
    • 2008
  • High-Speed train has been developed and it becomes faster and environmental friendly. As trains run faster, Noise of trains is generated mainly by aerodynamic disturbance. Pantograph, both ends of trains, and gaps of coaches which are thought to be aerodynamic noise's factors are primarily studied. Pantograph is a similarly shaped metal framework on the roof of an electric high speed train, transmitting current from an overhead electric catenary wire. Panhead which contacts electric wires directly looks like a bluff strut, goes through flows, is sensitive to external disturbances and is one of the most important factors which decide whole vehicles' driving ability. In this study, aerodynamically robust optimized pantograph panhead shape is designed and then evaluated through subsonic wind tunnel test. To compare these with existing panhead rectangular shapes or circular cylinder shapes, By visualizing strong vortex flow patterns which are main noise sources, characteristics are compared and analyzed

  • PDF

Prediction of Useful Life by Heat Aging of Motor Fan Isolating Rubber (모터팬 방진고무부품의 노화수명 예측)

  • Kim, W.S.;Woo, C.S.;Cho, S.J.;Kim, W.D.
    • Elastomers and Composites
    • /
    • v.37 no.2
    • /
    • pp.107-114
    • /
    • 2002
  • This paper discusses the accelerated heat aging tests were carried out to predict the useful life of EPDM isolating rubber components of ventilation fan motor for clean room. 20% compression set results changes as the threshold are used for assessment of the useful life and the time to threshold value were plotted against reciprocal of absolute temperature to give the Arrhenius plot. The useful life at variable temperatures and activation energy are obtained from the Arrhenius relationship. An accelerated test program to assess useful life can be represented an appreciable investment in time was designed. We also considered the effect of antioxidant agents.

Evaluation and CFD Modelling of Flow behind Livestock Ventilation Fan for Small-Scale Wind Power Generation (축사 환기팬 후류의 풍에너지 평가 및 기류 형상의 전산유체역학 모델링)

  • Hong, Se-Woon;Lee, In-Bok;Seo, Il-Hwan;Kwon, Kyeong-Seok;Ha, Tae-Hwan;Hwang, Hyun-Seob
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.5
    • /
    • pp.79-89
    • /
    • 2012
  • The objectives of this paper were to evaluate the wind flow behind the livestock ventilation fan for small-scale wind power generation and to make flow profiles of imaginary ventilation fan for future simulation works. The field experiments using typical 50-inch fan indicated that the wind flow behind the ventilation fan had a good possibility of power generation with its high and steady wind speeds up to a distance of 2 m. The expected electricity yield was almost 101~369 W with a small (0.8 m radius) wind turbine. The decline of ventilation fan performance caused by the obstacle was also not significant with about 4 % from a distance of 2 m. The flow profiles for the computational fluid dynamics (CFD) simulation was created by combining the direction vectors analyzed from tuft visualization test and the flow predicted by the rotating fan modeling. The flow profiles are expected to provide an efficient saving of computational time and cost to design a better wind turbine system in future works.