• Title/Summary/Keyword: 파 차단

Search Result 176, Processing Time 0.028 seconds

Improving Wave Propagation Performance of an Ultrasonic Waveguide for Heat Isolation (열 차단용 초음파 도파관의 전파성능 향상 연구)

  • 최인석;전한용;김인수;김진오
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.7
    • /
    • pp.545-553
    • /
    • 2003
  • This paper is concerned with protecting piezoelectric transducers used in an ultrasonic flowmeter from the high temperature of hot fluid in a pipe by using a waveguide and with improving the propagation of ultrasonic longitudinal vibration in the waveguide. Waveguide material has been chosen for efficient insulation of heat transferred in the waveguide, and the minimum length of the waveguide for protecting piezoelectric transducer has been estimated. Forced response of the longitudinal vibration in a uniform circular rod has been obtained and the length of the waveguide has been selected for maximum amplitude. Longitudinal vibration response of a conically-tapered rod excited at a natural frequency has been obtained to confirm that wave motion is amplified as the cross-sectional size of the waveguide decreases along the axial direction. The fact that dispersion of a pulse wave in a waveguide is reduced as the cross-sectional radius is decreased has been examined theoretically and confirmed experimentally by using a single-rod waveguide. A bundle-type waveguide has proven to be a practical one through the evaluation of the wave propagation performance.

Assessment of Design water level variation Due to Climate Change for Port Nam-Hyang, Ulleng-Do (기후변화 시나리오에 따른 울릉도 남양항의 설계수위 변화 평가)

  • Kwon, Kyong Hwan;Park, Jee Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.219-219
    • /
    • 2022
  • 지구 온난화와 함께 발생하는 해수면 상승은 한반도의 해안지역을 비롯하여 울릉도 등 도서지역 전반에 걸쳐 진행 중이다. 또한 해수면의 온도 상승으로 인한 열대저기압의 생성 시 에너지 공급이 증가하며 연안으로 내습하는 파랑 내습 에너지가 커지게 된다. 경상북도 울릉군에 위치한 남양항은 최근 2019년 태풍 다나스 및 2020년 태풍 마이삭 등에 의해 고파랑 혹은 침수 피해가 발생하여 항 내에서는 물양장과 선박이 파괴되고 방파제가 전도되는 등의 피해가 속출하였다. 동해안의 태풍 내습, 지구 온난화와 저기압 발달에 의한 수위 상승 등과 같은 다양한 해양기후를 고려한 연안 구조물의 파랑 영향을 검토하는 것이 중요할 것으로 판단되었다. 기상청 태풍센터에서 제공하는 1979년부터 2020년까지 한반도 해역에 내습한 태풍 중 울릉도에 영향을 미친 태풍은 18개로 울릉도 인근에 영향을 준 내습 태풍을 10년 단위로 분석해 보면, 1980년대 3개, 1990년대 2개, 2000년대 8개, 2010년대 3개, 2020년 2개로 2000년대에 울릉도 영향권에 들어간 태풍이 가장 많았으며, 심해파 추산 기간 이후 2020년 1년 동안 울릉도 인근으로 마이삭, 하이선과 같은 2개의 태풍이 연속적으로 영향을 주었다. 울릉도에 영향을 미친 18개 태풍을 대상으로 일본 기상청(JMA)에서 제공하는 1시간 바람장을 이용하여 파랑 후측 수치 모의를 수행하였으며, 해양수산부와 기상청 관측 부이를 이용하여 파랑에 대한 정확도를 확보하였다. 고파랑 내습 시 연안에 조우하는 수위 조건은 파랑 에너지의 증가를 결정하게 되며, 항만 구조물의 설계에 적용되고 있는 약최고고조위 이상(4대분조의 최대 조위)의 최극조위 조건에서 해안 구조물에 월파 및 침수 피해를 주는 요인으로 작용할 수 있다. 이를 바탕으로 울릉도 남양항에서 폭풍 시 내습한 최극고조위(0.65m)와 IPCC 5차 보고서에 제시한 최악의 시나리오(RCP 8.5) 조건에서 울릉도에서 확인된 0.79 cm 상승고를 반영하여 범람위험평가를 광역에서의 계산 결과를 입력자료로 하여 준 3차원 비 정수압 파랑 변형 수치 모형인 MIKE 3 Wave를 사용하여 실험하였다. 해수면 상승에 의한 수위 상승고는 연안 파랑 증가에 영향을 주었으며 연안 구조물의 침수 피해에 영향을 줄 것으로 판단되었다. 월파 차단, 파랑 차폐의 목적으로 건설되는 구조물의 규모 및 천단고 등을 설정하는데 설계 수위의 선정은 중요하다. 수치 실험 결과를 바탕으로 방파제 및 호안의 범람 위험 평가를 수행하고 구조물 설계 시 이러한 해수면 상승고가 반영된 설계가 중요하다는 것을 위험 평가를 통해 확인할 수 있다.

  • PDF

A Low-pass Filter with Wide-stop Band Using Radial-shaped Open Stub (광대역의 저지대역을 갖는 부채꼴 형태의 개방형 스터브를 이용한 저역통과 여파기)

  • Yoon, Ki-cheol;Kim, Seong-cheol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.7
    • /
    • pp.1237-1242
    • /
    • 2016
  • In this paper, the low pass filter with harmonics suppression and rejection using parallel coupled-line and radial type open stub is presented. And the resultant characteristic of the proposed low pass filter is that the harmonics are suppressed and rejected in wide bandwidth due to the parallel coupled-line structure. The open stub of a low pass filter is constructed in radial type which can be used to adjust the size of filter. The size of the proposed low pass filter is $6.98{\times}7.60mm2$ and the cut off frequency is 2.45 GHz. And the filter is economical in unit cost and can be constructed easily and has the merit of mass product because the filter is composed of distributed element. Also, the widely rejected harmonics is 128 % in the bandwidth and the insertion and return losses of the low pass filter are 1.07 dB and 19.5 dB, respectively.

Desirable Strategy of Dam Operation consider to Downstream Ecosystem (하류 하천환경을 고려한 바람직한 댐 운영방향)

  • Lee, Yo-Sang;Lee, Gwang-Man;Lee, Eul-Lae;Park, Jin-Hyuk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1989-1993
    • /
    • 2009
  • 댐의 조절방류가 하류 하천생태에 미는 영향은 매우 복잡하다. 하류생물상에 미치는 영향은 댐에서의 거리, 유황의 변화크기에 따라 달라진다. 흐르는 물에 서식하는 물고기는 좋아하는 수심, 유속 및 하상재질 등을 이용하여 살아간다. 다만 생물상은 주변환경에 적응하거나 변화하는 능력이 있어 댐의 조절방류에 의한 수생태계 변화구조를 명확히 해석하기는 불가능하다(Power et al., 1988). 댐에 의한 일정방류는 생물다양성을 감소시키며, 보다 변동성이 큰 방류하천은 하천, 연안 및 생물상 변화 유도에 긍정적인 것은 사실이다. 또한 큰 규모의 홍수파는 하천지형의 동적활동을 촉진시키며, 이는 하천을 터전으로 서식하는 동물상을 위한 생태학적 여건을 개선시켜 주게 된다. 이는 주변 식생의 생태적 조건 변화에 도움을 주기 때문에 적어도 1년에 2번 정도의 홍수파방류는 하천주변 서식처의 다양성 변화에 필요한 것으로 보고되고 있다(Kondolf and Wilcock, 1996). 최근들어 댐 하류하천의 생태복원을 위해 연속적인 홍수파 방류의 중요성이 강조되고 있는데(Stanford et al, 1996) 자연하도에서 댐과 같은 구조물에 의한 유량조절은 하중도나 사주 등을 발달시키고 사주에서는 두꺼운 식생층이 형성될 뿐만아니라 수목군의 현저한 출현을 보여준다. 이렇게 사주나 식생이 고착됨에 따라 이의 저항을 피해가는 수로가 형성되고 저수로 구간외에서는 식생의 발달이 더욱 왕성해져 그 면적이 확대되고 있다. 결국 사주와 사주가 식생으로 연결되고 여기에 수목이 자라면서 웬만한 홍수에도 파괴되지 않는 거대한 식생대가 출현하게 되는데 우리나라에서도 많은 하천에서 볼 수 있는 현상이다. 또한 댐에 의한 퇴사의 차단은 하천지형의 불균형을 초래하고 식생의 발달과 함께 저수도부는 좁아지고 세굴에 의해 깊어지는 현상을 보인다. 이와같은 현상들은 수문특성의 변화에 의하여 결국 댐의 조절방류에 의한 수문 변화는 하천지형의 변화를 유발하고 하천지형의 변화는 하천환경에 변화를 미치게 된다. 본 연구에서는 실제적으로 댐이 건설된 지역에서 조사된 몇몇의 자료를 분석하여 댐건설후에 나타나는 부정적 영향을 최소화하기 위한 바람직한 댐운영방안을 제시하고자 한다.

  • PDF

A Stepped Impedance Resonator Bandpass Filter with Superior Cut-off Response for ITS Application (우수한 차단 특성을 갖는 ITS용 SIR 대역 통과 여파기)

  • Nam Hee;Yun Tae-Soon;Lee Myeong-Gil;Lee Jong-Chul;Hong Ui-Seok
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.4 no.3 s.8
    • /
    • pp.73-78
    • /
    • 2005
  • In this paper, a bandpass filter with excellent cut off characteristic due to transmission zero using bypass coupling capacitor and with superior harmonic characteristic by interdigital capacitor is suggested. The measurement results for SIR bandpass filter with bypass coupling capacitor and interdigital capacitor show that the insertion loss is less than 1.9 dB and the return loss is better than 15.4 dB with 4.2 % bandwidth at the center frequency of 5.78 GHz.

  • PDF

Acoustic Wave Propagation Characteristics Corresponding to the Cut-off Frequency in Gas Pipeline (가스 배관의 차단 주파수에 따른 음파전달특성 연구)

  • Kim, Min-Soo;Lee, Sang-Kwon;Jang, Sang-Yup;Koh, Jae-Pil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.7
    • /
    • pp.693-700
    • /
    • 2008
  • High-Pressure gas Pipeline which is buried in underground has the Possibility that will be exposed to unexpected dangerous impact of construction equipment. To protect from this kind of danger, the real-time health monitoring system of the high-pressure gas pipeline is necessary. First of all, to make the real-time health monitoring system clearly, the acoustic wave propagation characteristics which are made from various construction equipment impacts must be identified. In link of technical development that prevents the damage of high-pressure gas pipeline, this paper gives FEM(finite element method) and BEM(boundary element method) solutions to identify the acoustic wave propagation characteristic of the various impact input signals which consist of Direc delta function and convolution signal of 45 Hz square signal and random signal.

Low Pass Filter Design using the SRR-DGS Resonator (SRR-DGS 공진기를 이용한 저역통과 필터 설계)

  • Kim, Jong-Hwa;Kim, Gi-Rae;Kim, Sung-Hoon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.8 no.4
    • /
    • pp.257-262
    • /
    • 2015
  • In this paper, the split-ring DGS resonator is proposed and its equivalent circuit are analyzed to design the low pass filter. Compared with the conventional dumbell DGS cell, this structure has a flat fluctuation in low frequency range and a sharp slop at edge frequency. The out-band suppression of the SRR-DGS cell can be improved by placing the open stubs on the conductor line which operates as parallel capacitances. Making use of equivalent circuit analytical method, the characteristics of the improved SRR DGS cell are investigated and applied to design compact low pass filter, which has a low in-band loss, sharp slop and high suppression of more than 35dB within a wide out-band frequency range. The dependence of the transmission characteristic on the dimension of a split ring, such as side-length and split-gap, is analyzed in detail. In addition, an improved SRR DGS cell model with open stubs loaded on the conductor line is then presented to improve the out-band suppression. By using the equivalent-circuit analytical method, an S-band microstrip low-pass filter with perfect low-pass characteristic and high out-band suppression is designed and fabricated.

Characteristics of High Efficiency Wideband Microstrip Band Pass Filter (고효율 광대역 마이크로스트립 대역통과필터 특성)

  • Lee, Young-Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.4
    • /
    • pp.636-644
    • /
    • 2009
  • This paper presents a compact, low insertion loss, sharp rejection and wide band microstrip band pass filter that is composed rectangular loop resonator and step-impedance-open-stub(SIOS) for wireless data communication. The SIOS can be reduce length about 30% more than general $0.25{\lambda}$ stub. And the stub can the advantage of tuning impedance magnitude. In order to demonstrate agrement of this paper prove, the optimized wide band pass filters are realized and experimented. A transmission line model used to calculate the frequency response of the new filters shows good agreement with measurements. The filter has 3dB fractional bandwith of 52.5%(3.267GHz), an insertion loss of better than 0.33dB from 4.587GHz to 7.854GHz, and two rejection of greater than 30dB within 221MHz$(4.366GHz{\sim}4.587GHz)$ at low frequency band, 181MHz$(7.854GHz{\sim}8.035GHz)$ at high frequency band. Maximum rejection characteristics of the filter are -54dB at low frequency and -60dB at high frequency.

A Low-pass filter design for suppressing the harmonics of 2.4GHz RFID tag (2.4GHz RFID 태그용 고조파 억제를 위한 저역통과필터의 설계)

  • Cho, Young Bin;Kim, Byung-Soo;Kim, Jang-Kwon
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.39 no.3
    • /
    • pp.59-64
    • /
    • 2002
  • In the RFID system using ISM-band, The tag mounted at the object has used the DC power by rectifying the RF signals of the small antenna for operating the micro-controller and memory. The performance of the tag would be reduced because of the second harmonics generated by the nonlinearity of the semiconductor and the spurious signal excited the high order mode of the antenna. This paper has realized the novel type low-pass filter with "the Stub-I type DGS slot structure" to improve the efficiency of the tag by suppressing the harmonics. The optimized frequency character at the pass-band/stop-band has obtained by tuning the stub width and slit width of I type slot. The measured result of the LPF has the cutoff frequency 3.25 GHz, the insertion loss about -0.29~-0.3 dB at pass-band 2.4 GHz~2.5 GHz, the return loss about -27.688~-33.665 dB at pass-band with a good performance, and the suppression character is about -19.367 dB at second harmonics frequency 4.9 GHz. This DGS LPF may be applied the various application as the RFID, WLAN to improve the efficiency of the system by suppressing the harmonics and spurious signals. 

Harmonic Suppression Compact Microstrip Patch Antenna for IoT Sensor (고조파 억제를 위한 IoT 센서용 소형 마이크로스트립 패치 안테나)

  • Lee, Hyun-Seung;Lim, Jeong-Taek;Jung, Bang-Chul;Kim, Choul-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.85-89
    • /
    • 2017
  • This paper proposes an antenna incorporating a bandstop filter to miniaturize the rectenna used for wireless power transmission with the emerging interest these days. To suppress the harmonics that can be re-radiated, this paper proposes a microstrip patch antenna that can suppress the harmonics while maintaining the size of the antenna by inserting a U-slot, which acts as a bandstop filter, on the ground plane of the antenna. As a result, S11 of the second harmonic(4.6GHz) was reduced from -5.61dB to -0.338dB and the efficiency was suppressed significantly from 29.76% to 1.5%. In addition, the maximum gain was reduced to -12dBi from 2.89dBi. On the other hand, at the fundamental frequency (2.45GHz), the S11 value was reduced from -18 dB to -15 dB, and the efficiency was reduced slightly from 68.2% to 60%. In the case of applying a microstrip antenna combined with the proposed bandstop filter to a rectenna, it is believed that the harmonics that degrade the performance of the rectenna can be removed effectively while reducing the large area occupied by harmonic suppression.