• Title/Summary/Keyword: 파형구조

Search Result 406, Processing Time 0.028 seconds

A Burst-Mode Limiting Amplifier with fast ATC Function (고속 ATC 기능을 갖는 버스트-모드 제한 증폭기)

  • Ki, Hyeon-Cheol
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.10
    • /
    • pp.9-15
    • /
    • 2009
  • In this paper, we invented a new structure of fast ATC(Automatic Threshold Control) circuit. Using the structure we made a new burst-mode limiting amplifier with fast ATC function using commercial $0.8{\mu}m$ BiCMOS technology. It's ATC function worked so fast that even the first bit of burst-data could be detected, which confirmed that the new structure was useful for fast ATC. However, in the beginning of a burst, distortions in duty-cycle occurred and increased up to 59% of duty-cycle as amplitude of input signal increased. But we confirmed that after 10 cycles passed, duty-cycles was staying below 52% of duty-cycle for any magnitude of input signal.

A Selection Method of Resonant Inductance for the Traveling Wave Type Ultrasonic Motor drive System using Series Resonant Inverter (직렬 공진형 인버터를 사용한 초음파 모터 구동시스템의 공진 인덕턴스 선정법)

  • 이을재;김영석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.105-114
    • /
    • 2000
  • To chive a traveling wave type ultrasonic motor with the series""-resonant inverter, the external inductor is i lnserted between the motor and inverter. In $\psi$is paper, we proposed a novel 3Ilalysis method to design the 3 ~xternal inductor. An equivalent model of the ultrasonic motor is expressed, and a selection method of the , ;;eries inductor is proposed from the basis of the model. When the series inductor has an optimal value, it is v velified by computer simulation results that power is efficiently transmitted to the mechanical resonant c component in the motor. The frequency and speed characteristics of the ultrasonic motor are investigated by e experiments for several external inductors. The validity of the proposed method for selecting external inductor i is clarified.clarified.

  • PDF

Effect of Direct Current and Pulse Current on The Formation Behavior of Plasma Electrolytic Oxidation Films on Al Alloy (Al 합금의 플라즈마 전해산화 피막 형성 거동에 미치는 직류 및 펄스 전류의 영향)

  • Kim, Ju-Seok;Mun, Seong-Mo;Sin, Heon-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.29.1-29.1
    • /
    • 2018
  • 양극산화 표면처리 방법의 일종인 플라즈마 전해산화(PEO, Plasma electrolytic oxidation)는 금속 소재에 양극 전압을 인가하여 고경도의 산화 피막을 금속 표면에 형성시키는 표면처리 기술이다. PEO 공정은 피막의 국부적 유전체 파괴에 의한 아크의 발생을 동반하며, 형성된 산화 피막이 아크 발생에 의한 높은 열에 의해 결정화 되어 일반적인 양극산화 피막보다 우수한 경도와 내마모성을 가진다. 하지만 PEO 공정은 고전압을 필요로 하여 일반적인 양극산화 처리보다 소모되는 전력량이 많으며, 아크 발생에 의해 형성된 피막의 표면 거칠기가 높기 때문에 활용 분야가 제한되거나 후속 연마 공정을 필요로 하는 단점이 존재한다. 본 연구에서는 전류 파형이 알루미늄 합금의 플라즈마 전해산화 피막의 형성 거동에 미치는 영향을 직류 및 펄스전류를 사용하여 연구하였다. NaOH 및 $Na_2SiO_3$가 혼합된 전해액에서 직류 전류 밀도, 전압, 펄스폭을 달리하여 알루미늄 합금에 전류를 인가할 때 발생되는 아크의 거동, 형성된 산화 피막의 두께, 거칠기, 경도, 표면 및 단면 구조를 비교 분석하였다.

  • PDF

Numerical Simulation of Nonlinear Free-Surface Flow around Seawall with Slope (경사면을 갖는 월파형 구조물 주위의 비서형성 자유표면류의 수치 시뮬레이션)

  • PARK JONG-CHUN;PARK DONG-IN;LEE SANG-BEOM;HONG GI-YONG
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.90-95
    • /
    • 2004
  • During the past 50 years methods for predicting wave overtopping of coastal structures have coastal structures have continuously been developed Wave overtopping is one of the most important processes for the design of seawalls. The term 'wave overtopping' is used here to refer to the processes where waves hit a sloping structure run up the slope and, if the crest level of the slope is lower than the highest run up level, overtop the structure. Wave overtopping is dependent on the processes associated with breaking wave. The Numerical model is based on Navier-Stokes equation and Marker-Density Function of method for nonlinear free-surface flow by Miyata & Park(1995). The influence of how the slopes of seawalls, wave type and crest freeboard affect overtopping discharges has been investigated. The research of study using the new development nonlinear free-surface flow numerical model SOLA-VOF are presented.

  • PDF

An Empirical Study on the Characteristics of Pore Water Pressure Reaction in Colluvium Model (붕적층내의 간극수압 반응에 관한 실험적 연구)

  • 정두영;최길렬
    • Geotechnical Engineering
    • /
    • v.8 no.2
    • /
    • pp.59-70
    • /
    • 1992
  • This work is to study experimentally the measurment of pore air pressure according to rainfall in colluvium model and the characteristics of pore water pressure according to increasement of artesian ground water head. After modeling a geological feature of the Tertiary formation, the experiment was performed about sixty times on three kinds of soil. This experimental results showed the variation of pore water and pore air pressures with time, the change of void ratio and appling pressure head in the nonsaturated soil. It can be also expressed by the final pore water and the air reaction ratios and then formularizing the relationship between the permeability coefficient and the void ratio. In the results of this experiment, the patterns of the pore water pressure reaction are classified by the step-type and the wave-type, and the time-lag to reach final point of pore water pressure is in order sand, sandy silt and clayey sand.

  • PDF

Fault diagnosis system of the short circuit conditions in windings for synchronous generator (동기발전기 권선단락사고 고장진단 시스템)

  • Jang, Nakwon;Lee, SungHwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.520-526
    • /
    • 2013
  • As the increasing of capacity and technology of power facilities, rotating machines are getting higher at capacity and voltage scale. Thus the monitoring and diagnosis of generators for fault detection has attracted intensive interest. In this paper, we developed fault diagnosis system for monitoring the fault operations in bad power systems. In order to verify the performance of this fault diagnosis system, we made the small scaled testing system which has the same winding structure of the real synchronous generator. The magnetic flux patterns in air-gap of a small-scale generator under various fault states as well as a normal state are tested by hall sensors and the fault detection system.

New Reset Waveform for a Large-Sustain-Gap Structure in AC PDPs (AC PDP의 장방전 구조의 구동을 위한 새로운 리셋파형)

  • Kim, Sun;Kim, Dong-Hun;Song, Tae-Yong;Kim, Ji-Yong;Lee, Seok-Hyun;Seo, Jeong-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1544-1545
    • /
    • 2006
  • In this paper, we present a new reset waveform for a large-sustain-gap structure in at PDPs. In the driving of the large-sustain-gap structure with a conventional ramp reset waveform, we cannot avoid the condition of an address being a cathode, which causes lots of trouble in stabilizing a reset discharge. To solve these problems, we use the square pulse instead of the conventional rising ramp pulse. Before making a strong discharge between the address (cathode) and scan (anode) electrodes, we make a priming discharge between the address (anode) and the scan (cathode) electrodes to stabilize the strong discharge in which the address electrodes are the cathode. With this scheme, we obtained 60V minimum address voltage and 145V maximum address voltage in $250{\mu}m$ and $350{\mu}m$ gap structures.

  • PDF

The Measurement & Analysis of Voltage Unbalance Factor at LV Customer of Three-Phase Four-Wire System (3상 4선식 저압 수용가의 전압 불평형률 측정 분석)

  • Kim, Jong-Gyeoum;Park, Young-Jeen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.91-99
    • /
    • 2004
  • Most of LV customer have applied the 3-phase four wire system distribution system because it has advantage of supplying both of 1-phase at 3-phase loads simultaneously. Due to its structural simplicity, it is more convenient for use rather than the conventional separated scheme. But once in a while uneven load unbalance or unclean power quality lead some problems such as do-rating or power losses. In this paper, voltage and current waveform in the actual fields have been measured and analyzed in relation with intermationally allowable voltage unbalance limits.

Prediction of Principal Frequency of Ground Vibration from Delayed Blasting (지연시차에 따른 발파진동의 주파수 특성 예측)

  • Chung, Doo-Sung;Kang, Choo-Won;Ko, Jin-Seok;Chang, Ho-Min;Ryu, Pog-Hyun
    • Tunnel and Underground Space
    • /
    • v.20 no.2
    • /
    • pp.112-118
    • /
    • 2010
  • Before blasts that can have direct impacts on human bodies or structures, it is necessary to assess impacts of ground vibration. Therefore, frequency has been recognized as an important factor in order to assess impact on ground vibration and damages. There have been many studies on impacts of frequency. But, there have been no studies on relations between vibration and frequency according to delay time difference. In this study, we examined the relations between delay time difference and frequency according to each frequency with which reinforcement and destructive intervention repeat through delay time difference obtained using superposition modeling of single hole blasting waveform based on the theory of time difference developed by Langefors.

Functional Improvement of Floating Breakwaters with Long Wave Kinetics (장주기 및 유동성분을 고려한 부유식방파제의 방파성능 개선)

  • Yoon, Jae-Seon;Cho, Yong-Sik
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.1
    • /
    • pp.93-99
    • /
    • 2011
  • In this study, a series of laboratory experiments are carried out to analyze fluid behaviors around multi-arranged (2 pieces) floating breakwaters with various parameters such as distance between structures, wave periods and steepness. The rate of wave transmission is shown to be affected directly by wave periods of incident waves and the breakwaters with multi-arranged structures show the highest rate of wave protection compared with other cases. The velocity fields around the breakwaters are measured by using the Laser Doppler Velocimetry system. The transmission coefficients are also measured in laboratory experiments. Finally, laboratory observed data are compared with numerical experimental results and analyzed in detail.