• Title/Summary/Keyword: 파장 간섭

Search Result 252, Processing Time 0.026 seconds

Measurement of Hysteresis in PZT-Type Tunable Filters Utilizing OFDR (OFDR을 이용한 PZT형 파장가변 필터의 이력 측정)

  • Park, Do-Hyun;Yeh, Yun-Hae
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.1
    • /
    • pp.36-42
    • /
    • 2008
  • Implementation of a wavelength-swept source with constant tuning rate adopting a PZT-type tunable filter, requires the knowledge of hysteresis of the filter used. The hysteresis must be considered to avoid any degradation in resolution of the optical frequency domain reflectometry (OFDR) system. An optical spectrum analyzer (OSA) could be used to do the hysteresis measurement, but its measurement time is too long for the high-speed driving conditions for the filter. We proposed a new hysteresis measurement method based on OFDR, which could measure the hysteresis in a real driving condition. A hysteresis measurement apparatus consisted of wavelength-swept source, interferometer, signal processing unit, and PC program is built and used to do the measurement. It is concluded that the new method is useful in the measurement of hysteresis at real driving conditions by successfully implementing a swept-wavelength source whose wavelength change is linear in time.

Integration of Depthmap Images from Microscopic Hologram System (다수의 홀로그램 깊이 영상 합성을 통한 완벽한 3D 데이터의 취득에 대한 연구)

  • Cho, Jung-Gyn;Lee, Ho-Dong;Son, Jung-Young;Park, Min-Chul
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2011.07a
    • /
    • pp.331-332
    • /
    • 2011
  • 디저털 홀로그래피는 CCD를 이용하여 간섭 패턴을 기록하고 기록된 간섭무늬에 담겨진 물체의 정보로 입체영상을 복원하는 기술을 말하며, 현미경을 이용한 디지털 홀로그래피 기술은 3D 형상 복원이나 바이오포토닉스 등 다양한 분야에서 사용되고 있다. 하지만, 디지털 홀로그래피 기술은 촬영된 간섭패턴에서 픽셀의 위상차가 레이저 파장의 1/2 이상일 경우, 기존의 phase unwrapping 알고리즘으로는 해당 픽셀의 위상차이를 계산할 수 없는 문제가 있다. 이와 같은 문제를 해결하기 위해 본 논문에서는 다수의 홀로그램 영상과 깊이맵을 사용하여 완전한 형태의 깊이맵을 구하는 방법을 제안한다.

  • PDF

A study on resolution analysis of incoherent trigangular holography (인코히어런트 삼각 홀로그래피의 해상도 분석에 관한 연구)

  • 김수길;김은수;이병호
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.2
    • /
    • pp.128-137
    • /
    • 1999
  • We found the point-spread function (PSF) including the recording and reconstruction systems of the modified triangular interferometer. We also derived the resolutions of the modified and Cochran's triangular interferometers, then the resolutions of both systems for amplification factor, wavelength, and hologram size were found and analyzed. Also, to demonstrate the feasibility of incoherent holography, the formation of an incoherent hologram using a mercury lamp and its optical reconstruction were presented.

  • PDF

CARS에서 배경신호의 제거에 의한 분광선회복

  • 이은성
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.457-463
    • /
    • 1993
  • We investigated that the CARS signals generated from resonant or nonresonant contributions can be selectively suppressed by phase-controlled nonlinear interferometry. To control the phase of the CARS signal over a broad spectral range, a home-made phase shifting unit was used, whose thickness was automatically controlled as the wavelength of Stokes beam scaned. Using this technique, we recovered the Q-branch resonance lines of carbon monoxide and HC1 which had been distorted and buried by the nonresonant and resonant signal of propane respectively. All the spectrum measured have been normalized by reference signal which had no resonance lines over the spectral range of interest.

  • PDF

SKA 소개 및 한국 참여 현황

  • Kim, Jong-Su;Ryu, Dong-Su;Son, Bong-Won;An, Gyeong-Jin;Jo, Jeong-Yeon;Choe, Min-Ho
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.74.2-74.2
    • /
    • 2011
  • SKA(Square Kilometre Array)는 수많은 전파망원경으로 이루어진 간섭계로, 그 총 유효 단면적이 약 1평방킬로미터이기 때문에, SKA라는 이름이 붙었다. 2024년 가동 예정인 SKA는, 감도(sensitivity)는 현존하는 가장 좋은 전파간섭계보다 50배, 하늘 서베이 속도는 약 만 배 빠를 것으로 예상된다. SKA는 파장 대역 별로 세 가지 서로 다른 전파 간섭계 (Sparse Aperture Array, Dense Aperture Array, and Dish Array)를 설치할 예정이다. 본 발표에서는 최근 SKA 개념 설계, SKA를 위한 조직 변화, 그리고 한국 참여 현황을 소개하겠다.

  • PDF

Two-Wavelength Phase-Shifting Projection $Moir\acute{e}$ Topography for Measurement of Three-Dimensional Profiles with High Step Discontinuities (고단차 불연속 형상의 3차원 측정을 위한 이중파장 위상천이 영사식 무아레)

  • Kim, Seung-Woo;Oh, Jung-Taek;Jung, Moon-Sik;Choi, Yi-Bae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.7 s.166
    • /
    • pp.1129-1138
    • /
    • 1999
  • [$Moir\acute{e}$] technique is now being extensively investigated as a fast non-contact means of three-dimensional profile measurement especially for reverse engineering. One problem with $moir\acute{e}$ technique is so called $2\pi$-ambiguity problem that limits the maximum step height difference between two neighboring sampling points to be less than half the equivalent wavelength of $moir\acute{e}$ fringes. In this investigation, a new two-wavelength scheme of projection $moir\acute{e}$ topography is proposed and tested to cope with the $2\pi$-ambiguity problem. Experimental results are discussed to assess the new method in measuring large objects with high step discontinuities.

Actinometry에 의한 CF4플라즈마에서의 F라디칼의 공간분포

  • Lee, U-Hyeon;Jeong, Jae-Cheol;Kim, Dong-Hyeon;Kim, Hyeok;Hwang, Gi-Ung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.217-217
    • /
    • 2011
  • 플라즈마를 이용하는 식각 및 증착등의 반도체공정에 있어서 최근에는 기판의 크기가 점차 증가하는 추세에 있다. 이러한 대면적 플라즈마 발생장치 내에서 플라즈마 밀도와 라디칼 농도의 공간적인 특성을 이해하는 것에 대한 중요성이 더해지고 있다. 이를 위해 Langmuir probe와 같은 전기적 접근법에 의한 진단방법이나 광학적 접근법에 의한 진단방법에 대한 연구가 이루어 졌다. 전기적 접근법에 의한 플라즈마의 진단방법은 원리가 간단하고 정확도가 높다는 장점이 있지만 진단 장치에 의한 플라즈마의 간섭이 크고 식각가스의 경우 진단이 어렵다는 단점이 있다. 그에 비해 광학적 진단방법은 플라즈마에 간섭이 많지 않은 방법으로 알려져 있고 레이저 형광법(LIF), 원적외선 레이저 흡수 분광법(IR laser Absorption Spectroscopy), 광량측정법(Actinometry)등이 있다. 이 중 레이저 형광법, 원적외선 레이저 흡수 분광법의 경우, 진단장치가 매우 복잡하고 가격이 비싸다는 단점을 가지고 있다. 반면 광량측정법의 경우 다른 광학적 접근법에 의한 진단방법에 비해 원리와 실험장치가 간단하고 공간적인 라디칼 분포의 진단이 쉽다는 점에서 장점을 가지고 있다. Actinometry는 Ar과 같은 불활성 기체를 작은 비율을 넣어서 여기 된 불활성 기체의 파장세기와 여기 된 측정 라디칼의 파장세기의 비교를 통해 상대밀도를 측정하는 방법이다. 이 측정 방법에 Abel's inversion equation을 적용함으로 해서 대면적 M-ICP(Magnetized - Induced Coupled Plasma)에서 식각가스인 $CF_4$플라즈마에서 F 라디칼 농도의 공간적인 분포를 측정하고 분석하였다. 또한 플라즈마의 압력, 소스 전력 값과 기판 전력 값등의 조건의 변화에 따라 F 라디칼 농도의 분포가 어떻게 달라지는지에 대해 측정 분석하여 다루었다.

  • PDF

Analysis for the magneto-optical Kerr effect of metal multilayers by optical multiple reflection (다중반사에 의한 금속다층막의 자기광학 Kerr 효과 분석)

  • 최영준;서용원
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.4
    • /
    • pp.307-312
    • /
    • 1994
  • The magneto-optical Kerr effect due to the (Fe,Co)/(Pd,Pt,Cu,Ag) multilayer film is calculated considering of multiple reflection effect, and the calculated Kerr spectrum is compared to the reported experimental value. In case of Co/Pd, the reliance of composition and the variable tendency of magneto-optical Kerr rotation angle for Co thickness fully coresponds to experimantal and theoretical value. The theoretical Kerr spectrum of Fe/Cu and Fe/Ag multilayer films show the peaks near the Cu and Ag optical ansorption band in accordance with the experiment. But in case of Co/Pt, the increase tendency of Kerr rofation with decreasing wavelength reported by experiments could not be explained by the optical multiple interference. This difference of theoretical and experimental Kerr spectrum of Co/Pt film might be related with the change of electronic structure of Co and/or Pt from their bulk state.

  • PDF

Wavelength Scanning Lateral Shearing Interferometer for Freeform Surface Measurement (고경사 자유곡면 측정을 위한 파장변조 층밀리기 간섭계)

  • Rhee, Hyug-Gyo;Ghim, Young-Sik;Lee, Joohyong;Yang, Ho-Soon;Lee, Yun Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.3
    • /
    • pp.199-205
    • /
    • 2014
  • We propose a new variant of lateral shearing interferometer with a tunable laser source that enables 3D surface profile measurements of freeform optics with high speed, high vertical resolution, large departure, and large field-of-view. We have verified the proposed technique by comparing our measurement result with that of an existing technique and measuring a representative sample of freeform optics. Moreover, we propose a new algorithm that is able to compensate the rotational inaccuracy.