• Title/Summary/Keyword: 파수 스펙트럼

Search Result 88, Processing Time 0.023 seconds

Analysis of Sounds from different Impact Points of Golf Driver (골프 드라이버 임팩트 위치에 따른 소리 분석)

  • Kim, Ho Sung;Jung, Dong Keun
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.2
    • /
    • pp.1-7
    • /
    • 2013
  • This study was aimed to evaluate the characteristics of impact sound of golf driver according to impact points of its face. In order to get the consistent impact sounds, the apparatus for free golf ball drop was prepared and used. Timed amplitude patterns and maximum spectral peaks of the impact sounds were variant according to the impact points of driver face. As an alternative method of impact sound analysis, cumulative sum of spectral power (cumsum) was used to distinguish between impact sounds according to the impact positions. From the comparison of frequencies representing 20%, 40%, 60%, 80% of cumsum of impact sound, 40% cumsum frequency of the center of driver face was lower than that of the toe and the heel. This finding suggests that the impact sound from the center of driver face has higher spectral power of low frequency component than that of the toe and heel.

Measurement and simulation of high-frequency bistatic sea surface scattering channel in shallow water of Geoje bay (거제 내만해역에서의 고주파 양상태 해수면 음파산란 채널 측정 및 모의)

  • Choi, Kang-Hoon;Kim, Yongbin;Kim, Sea-Moon;Choi, Jee Woong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.1
    • /
    • pp.1-9
    • /
    • 2021
  • High-frequency bistatic sea surface scattering channels according to sea state were measured at an experimental site of Geoje bay in April 2020, and compared with predictions based on scattering theory. A linear frequency-modulated signal with a center frequency of 128 kHz and a bandwidth of 32 kHz was used for the acoustic measurements. Sea surface wavenumber spectrum was calculated from surface roughness data measured by a wave buoy, and bistatic scattering cross-section of Small Slope Approximation (SSA) based on the wavenumber spectrum was estimated. In addition, scattering from near-surface bubbles using wind speed measured during experiments was considered. Surface scattering channel intensity impulse responses were simulated using the scattering cross-section and the simulation results were compared and analyzed with the field data.

Spectral Analysis of Heart Rate Variability in Electrocardiogram and Pulse-wave using autoregressive model (AR모델을 이용한 심전도와 맥파의 심박변동 스펙트럼 해석)

  • 김낙환;민홍기;이응혁;홍승홍
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2000.08a
    • /
    • pp.289-292
    • /
    • 2000
  • 선형 자귀회귀(AR) 모델을 근거로한 HRV 파워 스펙트럼해석은 비침습적으로 자율신경의 반응을 정량화하는데 폭넓게 사용된다. 본 연구는 단구간(2분 미만)의 심전도와 맥파 신호로부터 시계열 HRV의 파워스펙트럼을 추정한다. 시계열은 정상인을 대상으로 검출한 심전도와 맥파신호의 특징점 시간간격(RRI, PPI)으로부터 구하였다. 발생된 시계열은 다항식 보간법에 의해 AR모델에 적합하게 재구성하였으며, AR모델 계수는 Burg법에 의해 계산하였다. AR모델을 적용한 단구간의 심전도와 맥파의 심박변동에 대한 파워스펙트럼밀도는 저주파수(LF)와 고주파수(HF)에서 매끄러운 스펙트럼 파워를 나타내고 있다. 또한 동일한 피험자의 심전도와 맥파의 파워스펙트럼밀도를 비교한 결과 동일한 모양을 나타내었다.

  • PDF

Tidal Variation of Waves in Kyung-Gi Bay (경기만 조석조건에서의 파랑변이)

  • 김지웅
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.12 no.2
    • /
    • pp.87-95
    • /
    • 2000
  • Spectral wave models are applied to the area of Kyung-gi bay with two different combinations. One combination assumes a constant tidal elevation over the whole region when applying the wave model to the area. In this case no tidal currents exist in any place. The other combination employs tide model as well as wave model so that tidal condition is defined at every computation time when wave modelling is carried out. Significant wave heights and wave directions are shown for these two cases. With these two different constraints of tidal variation, the results are checked and compared with each other. Both results are found significantly different from each other.

  • PDF

Frequency-Wave Number Method for the Automated Calculation of the Phase Velocities from the SASW Measurements (SASW실험 분산곡선의 자동화 계산을 위한 주파수-파수 기법)

  • 조성호;강태호
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.299-310
    • /
    • 2003
  • In the evaluation of the subgrade stiffness structure by the SASW method, the calculation of the phase velocities is the important task controlling the reliability of the result. The interpretation of the phase spectrum should precede the phase-velocity calculation in the current practice of the SASW method. The difficulty involved in the interpretation prohibited the SASW method from being spread over to the industry. This study proposed a new method called the frequency-wave number technique, which is based on the frequency-wave number relationship of the surface wave in the multi-layered system. The frequency-wave number technique eliminates the expertise in the interpretation of the phase spectrum, automates the phase-velocity calculation and expedites the determination of the phase-velocity dispersion curve. To verify the validity of the proposed frequency-wave number method, the transfer function determined from the numerical simulation of the SASW measurements was used fir the calculation of the automatic calculation of the phase velocities and compared with the phase velocities by WinSASW employing the phase-unwrapping method. Also, the proposed method was applied to the real SASW measurements performed at$\bigcirc$$\bigcirc$area in GyeongGi-Do to see how the proposed method works with the real measurements.

Analysis of Response Spectrum of Ground Motions from Mine Blasting (발파에 의한 지반진동의 응답스펙트럼 분석)

  • Kim, Jun-Kyoung
    • Tunnel and Underground Space
    • /
    • v.15 no.5 s.58
    • /
    • pp.338-343
    • /
    • 2005
  • This study analysed response spectrum using the observed ground motion from the mine blasting and, then compared the results to the seismic design response spectra applied domestic nuclear power plants. The results showed that the resultant response spectra above 20 Hz revealed higher values than the design response spectra and those below 20 Hz revealed much lower values. These facts suggest that the analysis of response spectrum should be applied to the analysis of impacts to frequency dependent structures in addition to the analysis of peak values of ground motions.

Proper frequency band as EMG fatigue indices of biceps femoris muscles during treadmill walking (드레트밀 보행시 대퇴이두근의 EMG 근피로지수로서 적당한 주파수 대역)

  • Jongchil Won;Kiyoung Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.17 no.3
    • /
    • pp.141-145
    • /
    • 2024
  • Because of muscle fatigue, motor unit recruitment and firing rates decrease and EMG power spectrum shifts toward lower frequencies as spectral compression which represented by a falling shift in the median frequency. However, changes of this frequency shows relatively less than those of the magnitudes of the low frequency band. This paper aims to examine the moderate ranges of the frequency bands in the existed ones as spectral fatigue indices of biceps femoris muscle. Twelve subjects participate in this experiment, and EMG signals are measured from these muscles during treadmill walking on the speed of 4.5 km/h. ANOVA analysis is used to compare changes of the low and high frequency band with reference to those of median frequency. Experimental results demonstrate that the low frequency band 25-82 Hz and the high frequency band 142-300 Hz could be appropriate for spectral fatigue indices of biceps femoris muscles.

Electroluminescent Properties of ZnS:Gu with Mixed Ratio of Blue Dye (청색 염료 혼합비율에 따른 ZnS:Cu의 전계 발광 특성)

  • Lee, Jong-Chan;Kim, Tae-Hyung;Kim, Ki-Dae;Park, Das-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1733-1735
    • /
    • 2000
  • 평판 디스플레이 소자인 후막 전계발광소자는 평판형 조명부터 LCD 백라이트에 응용되고 있다. 후막 전계발광소자에 사용되는 ZnS:Cu 형광체는 저주파수에서는 녹색 발광을 하며, 고주파수에서는 청색 발광을 가진다. 본 연구는 저주파수에서도 청색을 가지는 소자를 제작하기 위하여 형광체와 염료의 혼합 비율에 따른 발광특성을 조사하였다. 염료의 혼합 비율은 0$\sim$5 wt%로 하였다. 소자의 발광현상을 고찰하기 위하여 발광 스펙트럼과 휘도를 측정하였다.

  • PDF

Time Domain Prediction and Analysis of Low Frequency Noise from Wind Turbine using Hybrid Computational Aeroacoustics (CAA) Method (복합 전산 공력음향학(CAA) 방법을 이용한 시간영역 풍력터빈 저주파수 소음 예측과 분석)

  • Lee, Gwang-Se;Cheong, Cheolung;Kim, Hyung-Taek;Joo, Won-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.5
    • /
    • pp.369-376
    • /
    • 2013
  • Using Lowson's acoustic analogy, low frequency noise of a wind turbine (WT) is predicted in time domain and the noise sources contributing to the low frequency noise is analyzed. To compute averaged pressure distribution on blades of the WT as noise source, XFOIL is utilized. The blade source domain is divided into several segments along the span direction to compute force exerted on air surrounding the blade segments, which is used as input for noise prediction. The noise sources are decomposed into three terms of force fluctuation, acceleration and velocity terms and are analyzed to investigate each spectral contribution. Finally, predicted spectra are compared with measured low frequency noise spectrum of a wind turbine in operation. It is found that the force fluctuation component contributes strongly in low frequency range with increasing wind speed.

Spectral Analysis of Heart Rate Variability in ECG and Pulse-wave using autoregressive model (AR모델을 이용한 심전도와 맥파의 심박변동 스펙트럼 해석)

  • Kim NagHwan;Lee EunSil;Min HongKi;Lee EungHyuk;Hong SeungHong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.1 no.1
    • /
    • pp.15-22
    • /
    • 2000
  • The analysis of power spectrum based on linear AR model is applied widely to quantize the response of autonomic nerve noninvasively, In this paper, we estimate the power spectrum density for heartrate variability of the electrocadiogram and pulse wave for short term data(less than two minute), The time series of heart rate variability is obtained from the time interval(RRI, PPI) between the feature point of the electrocadiogram and pulse wave for normal person, The generated time series reconstructed into new time series through polynomial interpolation to apply to the AR mode. The power spectrum density for AR model is calculated by Burg algorithm, After applying AR model, the power spectrum density for heart rate variability of the electrocadiogram and the pulse wave is shown smooth spectrum power at the region of low frequence and high frequence, and that the power spectrum density of electrocadiogram and pulse wave has similar form for same subject.

  • PDF