• Title/Summary/Keyword: 파손 원인 분석

Search Result 176, Processing Time 0.023 seconds

A Study on Metal Bound Rims Adhered to the Brim of Ceramics (도자기 구연에 부착된 금속 테두리 연구)

  • Hwang, Hyun-Sung;Yang, Pil-Seung;Seo, Jeong-Ho
    • Journal of Conservation Science
    • /
    • v.22
    • /
    • pp.109-120
    • /
    • 2008
  • Understanding the whole knowledge of ceramics is essential for a person in charge of conservation of ceramics since their methods of manufacturing or materialistic features have very close relationship with their damaging process. Also, various executions of repair and restoration dealing with any damage in use have to be looked into. The information attained through those studies finds damaging causes of ceramics, which becomes a critical element when choosing a proper conservation treatment method and utilizes as indispensable data for permanent preservation. As part of scrutinizing materials of repair and restoration, this study examines the purpose, date, and the constituents of the materials used in metal bound rims adhered to the brim of ceramics. Among the subjected ceramics, the metal bound rims possible to scientific analysis were gone through element analyses with Portable ${\bullet}\"{I}$-XRF Spectrometer and SEM-EDS while the ingredients of the ceramics difficult to analyze were inferred by eye inspection of exhibition catalogues. The results of this study confirm that metal bound rims consisted of diverse materials were adhered to the brim of ceramics.

  • PDF

Analysis of Train Delay in Daejeon Metro (대전도시철도의 열차 지연운행 분석연구)

  • Kwon, Young-Seok;Lee, Jin-Sun
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.1
    • /
    • pp.50-57
    • /
    • 2017
  • This study investigated the causes and problems of train operation impediments through the statistics analysis of 8 years'internal data of Daejeon Metropolitan Express Transit. By evaluating the risks regarding the system, equipment, and parts of high risk group, this study measured the Risk Index Severity, and applied the $5{\times}5$ Risk Assessment Matrix which is a method of risk management to calculate the scale of risk to analyze the safety level and allowance range. As a result, the car sector, the most serious risk, followed by machinery and equipment sector showed that the inherent risk. In particular, the door broken and the door rail signaling and control devices due to defects of the vehicle is high, but also the severity, and frequency are showing very frequent additional potential accidents. PSD also had defects in the machinery sector appeared to be the most dangerous of the PSD poor safety gates, it was found that the glass also involve the risk of mishandling and breakage of the PSD. This study intended to contribute to the transportation benefits through the safety and stable operation of Metropolitan Express Transit.

A Study on the Analysis of Scaling Failure Cause in L-Shoulder Concrete Structure (L형측구 콘크리트 구조물의 표면박리파손 원인분석에 관한 연구)

  • Jeon, Sung Il;Nam, Jeong Hee;Ahn, Sang Hyeok;An, Ji Hwan
    • International Journal of Highway Engineering
    • /
    • v.16 no.6
    • /
    • pp.27-37
    • /
    • 2014
  • PURPOSES : The purpose of this study is to verify the causes of surface scaling at L-shoulder concrete structure. METHODS : From the literature reviews, mechanisms of frost damage were studied and material properties including strength, air void, spacing factor and scaling resistance of L-shoulder concrete structure were analyzed using core specimens taken by real fields. RESULTS : The spacing factor of air void has relatively high correlation of surface conditions : lower spacing factor at good surfacing condition and vice versa. If the compressive strength is high, even thought spacing factor does not reach the threshold value of reasonable durability, the surface scaling resistance shows higher value. Based on these test results, the compressive strength also provide positive effect on the surface scaling resistance. CONCLUSIONS : The main causes of surface scaling of L-shoulder could be summarized as unsuitable aid void amount and poor quality of air void structure. Secondly, although the compressive strength is not the governing factor of durability, but it shows the positive effect on the surface scaling resistance.

On the Improvement for Design Methods of Luminaire Supports Based on the Structural Safety (구조안전성 기반의 가로등주 설계개선방안)

  • Jung, Soo Hyung;Shim, Jae Soo;Choi, Hyun Gyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.6
    • /
    • pp.45-55
    • /
    • 2012
  • The road luminaires have been treated as subsidiary electric apparatuses in the road although they are indispensable facilities which people use the road safely. Because of this misunderstanding, there are not many researches on luminaire supports against the wind loads. Therefore, a typhoon has overturned or damaged many luminaire supports without having sufficient structural safeties. The purpose of this study is to review the current design criteria and to suggest the improvement of design methods based on the structural safety and compatible with the site conditions of luminaire supports. The stress concentration around the inspection hole, which causes the collapse of luminaire supports, is analyzed and stress reduction method is suggested with the improved design methods.

Research on fault analysis and reliability improvement of APU start motor for Korea Utility Helicopter (한국형 기동헬기 APU 시동모터 결함원인 분석 및 신뢰성 개선)

  • Kang, Tae-Woo;Yeom, Hyo-Won;Lee, Hee-Rang;Ahn, Jong-Moo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.703-709
    • /
    • 2017
  • Korea Utility Helicopter(KUH) is a project to replace the aging helicopter presently being operated by the military with a domestic helicopter. The auxiliary power unit is a device that supplies emergency power to the system by an alternator installed when the main generator fails and the start motor converts the electrical energy of the battery into mechanical rotational energy to rotate the auxiliary power unit engine. With continuing power and operation, defects of the starting motor were found and improvements were carried out to solve it. In the failure mode analysis, the causes of possible defects were classified into 5 categories. Analysis of the 5 factors revealed that the main cause of defects is mechanical wear, which was found to be related to spring pressure. 250 tests were conducted through the theoretically determined pressure and regression analysis was performed with 4 sampling.The results showed that pressure was related to wear rate. In conclusion, early wear and breakage due to wear can be controlled through spring force and test showed the prediction of wear and the validity of the result were confirmed.

Reconstruction Analysis of Multi-Car Rear-End Collision Accidents: Empirical/Analytical Methods, and Application of Video Event Data Recorder (다중추돌사고의 재구성 해석: 경험적/해석적 방법과 영상사고기록장치 활용)

  • Han, In-Hwan
    • Journal of Korean Society of Transportation
    • /
    • v.30 no.2
    • /
    • pp.127-136
    • /
    • 2012
  • Multi-car rear-end collision accidents have three categories: sequential collision from the rear which is commonly referred to as chain reaction collision, sequential collision from the front, and mixed-order collision. This paper suggests several effective methods of reconstruction analysis for multi-car rear-end collision accidents. First, by incorporating the traditional empirical method which uses vehicle damage caused by brake dive and passenger injuries, with results of theoretical analysis made within mechanics of rigid body, it is made possible for the method to be put to immediate practical use. A methodology to precisely analyze multi-car rear-end collision accidents was suggested using a simulation program simultaneously with a video event data recorder which is starting to be widely used in domestic vehicles. To go beyond the simple intuitive analysis of the video event data recorder, the simulation analysis based on the results of video analysis was executed to acquire various information, so that the causes and responsibility could be clearly stated.

Corrosion Failure Analysis of the Convection Part of District Heating Peak Load Boiler (지역난방 첨두부하보일러 대류부 부식 파손 분석)

  • Kim, Youngsu;Chae, Hobyung;Hong, Minki;Song, Min Ji;Cho, Jeongmin;Kim, Woo Cheol;Ha, Tae Baek;Lee, Soo Yeol
    • Corrosion Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.55-60
    • /
    • 2019
  • Corrosion failure in the convection part of peak load boiler (PLB) of the district heating system led to water leakage. Herein, Internal Rotary Inspection System (IRIS) inspection was employed to examine wall thinning and the cause of leakage in the flue tube. The corrosive products of the turbulator and tube were investigated using scanning electron microscope combined with energy dispersive spectroscopy, X-ray diffraction, and inductively coupled plasma (ICP). Majority of the serious corrosion damage was observed near the turbulator located in the upper flue tube. ICP analysis of the boiler water revealed oxide formation of sodium chloride in the lower end part of the flue tube. A cross-sectional view of the turbulator revealed the presence of double-layers of the oxide film, indicating environmental change during operation associated with water leakage. The outer surface of the turbulator consisted of the acid oxides such as $NO_x$ and $SO_x$ along with sodium and chloride ions. Dew-point corrosion is hypothesized as the main cause for the formation of acid oxides in the region of contact of the flue tube and the turbulator.

Failure Analysis of Welded type 304 in Cooling Water Pipeline of District Heating System (지역난방 냉각수 배관의 용접부 파손 분석)

  • Jeong, Joon-Cheol;Kim, Woo-Cheol;Kim, Kyung Min;Sohn, Hong-Kyun;Kim, Jung-Gu;Lee, Soo-Yeol;Kim, Heesan
    • Corrosion Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.296-301
    • /
    • 2020
  • Failure analysis on the welded type 304 pipe used for cooling water piping in the district heating primary side was conducted. Inorganic elements and bacteria in the cooling water and in corrosion products were analyzed, and the weldment was inspected by microscopy and a sensitization test. Corrosion damages were observed in the heat-affected zone, on weld defects such as incomplete fusion or excessive penetration caused by improper welding, or/and at the 6 o'clock position along the pipe axial direction. However, the level of concentration of chloride in the cooling water as low as 80 ppm has been reported to be not enough for even a sensitized type 304 steel, meaning that the additional corrosive factor was required for these corrosion damages. The factor leading to these corrosion damages was drawn to be the metabolisms of the types of bacteria, which is proved by the detection of proton, sulfur containing species, biofilms, and both bacteria and corrosion product analyses.

Corrosion Failure Analysis of a Biogas Pipe (바이오가스 배관의 부식 파손 원인 분석)

  • Min Ji Song;Woo Cheol Kim;Heesan Kim;Jung-Gu Kim;Soo Yeol Lee
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.36 no.3
    • /
    • pp.153-160
    • /
    • 2023
  • The use of biogas is an industrially necessary means to achieve resource circulation. However, since biogas obtained from waste frequently causes corrosion in pipes, it is important to elucidate corrosion mechanisms of the pipes used for biogas transportation. Recently, corrosion failure occurred in a pipe which supplied for the biogas at the speed of 12.5 m/s. Pinholes and pits were found in a straight line along the seamline of the pipe. By using corrosion-damaged samples, residual thickness, microstructure, and composition of oxide film and inclusion were examined to analyze the cause of the failure. It was revealed that the thickness reduction of biogas pipe was ~0.11 mm per year. A thin sulfuric acid film was formed on the surface of the interior of a pipe due to moisture and hydrogen sulfide contained in a biogas. Near the seamline, microstructure was heterogeneous and manganese sulfide (MnS) was found. Pits were generated by micro-galvanic corrosion between the manganese sulfide and the matrix in the interior of the pipe along the seamline. In addition, microcracks formed along the grain boundaries beneath the pits revealed that hydrogen-induced cracking (HIC) also contributed to accelerating the pitting corrosion.

A Study on the Identification Technique and Prevention of Combustion Diffusion through ESS (Energy Storage System) Battery Fire Case (ESS (에너지 저장장치) 배터리 화재사례를 통한 감식기법 및 연소 확산방지에 관한 연구)

  • Lee, Jung-Il
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.383-391
    • /
    • 2020
  • Purpose: To identify internal self ignition and ignition caused by external flames in energy storage rooms, and to analyze the difference between ignition due to overheating and ignition caused by external heat sources. Method: membrane melting point measurement, battery external hydrothermal experiment, battery overcharge experiment, comparative analysis of electrode plate during combustion by overcharge and external heat, overcharge combustion characteristics, external hydrothermal fire combustion characteristics, 3.4 (electrode plate comparison) / 3.5 (overcharge) /3.6 (external sequence) analysis experiment. Result: Since the temperature difference was very different depending on the position of the sensor until the fire occurred, it is judged that two temperature sensors per module are not enough to prevent the fire through temperature control in advance. Conclusion: The short circuit acts as an ignition source and ignites the mixed gas, causing a gas explosion. The electrode breaks finely due to the explosion pressure, and the powder-like lithium oxide is sparked like a firecracker by the flame reaction.