• Title/Summary/Keyword: 파괴진행

Search Result 860, Processing Time 0.024 seconds

Study on PWHT embrittlement of weld HAZ in Cr-Mo steel (Cr-Mo 鋼 溶接熱影響部의 溶接後熱處理 脆化에 관한 硏究)

  • 임재규;정세희
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.2
    • /
    • pp.314-321
    • /
    • 1987
  • Post weld heat treatment (PWHT) of weldment of the low alloy Cr-Mo steel, in general, is carried out not only to remove residual stress and hydrogen existing in weldment but to improve fracture toughness of weld heat affected zone (HAZ). There occur some problems such as toughness decrement and stress relief cracking (SRC) in the coarse grained region of weld HAZ when PWHT is practiced. Especially, embrittlement of structure directly relates to the mode of fracture and is appeared as the difference of fracture surface such as grain boundary failure. Therefore, in this paper, the effect of heating rate on PWHT embrittlement under the various kinds of stresses simulated residual stress in weld HAZ was evaluated by COD fracture toughness test and observation of fracture surface. Fracture toughness of weld HAZ decreased with increment of heating rate under no stress, but it was improved to increment of heating rate under the stress. Grain boundary failure didn't almost appear at the heating rate of 600.deg.C/hr but it appeared from being the applied stress of 294 MPa at 220.deg.C/hr and 196 MPa at 60.deg.C/hr.

Impact Resistance Evaluation of RC Beams Strengthened with Carbon FRP Sheet and Steel Fiber (CFRP 시트 및 강섬유로 보강된 RC 보의 충격저항 성능 평가)

  • Cho, Seong-Hun;Min, Kyung-Hwan;Kim, Yun-Ji;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.5
    • /
    • pp.719-725
    • /
    • 2010
  • The analysis and experimental program of reinforced concrete (RC) structures for resistance against such extreme loads as earthquake, blast, and impact have been carried by many researchers and designers. Under the extreme loads, a large amount of energy is suddenly exerted to the structure, hence if the structure fails to absorb the impact energy, catastrophic collapse may occur. To prevent catastrophic collapse of structures, reinforced concrete must have adeguate toughness or it needs to be strengthened. The FRP strengthening method and SFRC are studied widely in resistance of impact load because of their high energy absorption capacity. In this study, drop weight impact tests were implemented to evaluate the impact resistance of SFRC and FRP strengthened RC beam while the total steel fiber volume fractions was fixed at 0.75% carbon FRP flexural strengthened RC beams. Futhermore, to prevent the shear-plug cracks when the impact load strikes the beams, additional FRP shear strengthening method are applied. The experimental, results showed that the FRP strengthened RC SFRC beams has high resistance of shear-plug cracks and crack width and SFRC has high resistance of concrete spalling failure compared to normal RC beams. The FRP flexural and shear strengthening RC beams has weakness in the spalling failure because the impact load concentrated the concrete face which is not strengthened with FRP sheets.

Analysis of Compression Characteristics of the Steel Plate-Concrete Wall Structures with Openings (개구부가 있는 강판콘크리트 벽체의 압축특성 분석)

  • Choi, Byong-Jeong
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.3
    • /
    • pp.245-256
    • /
    • 2012
  • The objective of this study is to investigate the effect of the openings on the structural behavior of SC walls. The test parameters were with or without the reinforcing of openings and sleeve thickness. The common failure showed that the crack in the concrete progressed with the plate's local buckling between the shear connectors. The failure of the openings showed that the vertical wall of the sleeve buckled toward the opening inside. The plate buckling load showed a similar value with or without the sleeve of the opening, respectively. However, the maximum compressive strength of the specimen without the opening was higher than that of specimen with the opening.

A Weibull Statistical Analysis of High Thermal Resistance Insulation Material through AC Breakdown Characteristic of Mckewon Electrode (Mckewon 전극 AC절연파괴특성 시험을 통한 고내열성 절연재료의 Weibiull 통계분석)

  • Lim, Jang-Seoub;Kim, Su-Hwan;Lee, Seung-Won;Kim, Yong-Hyun;Lee, Byung-Sung;Jung, Yeon-Ha
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1184-1184
    • /
    • 2015
  • 현재 XLPE 절연 케이블의 상시 운전 온도는 $90^{\circ}C$나 개발된 고내열성 절연재료의 상시운전온도는 $110^{\circ}C$로 향상되었다. 개발된 고내열성 절연재료는 XLPE 절연 케이블의 상시 운전온도($90^{\circ}C$)와 비상시운전온도($110^{\circ}C$), 고내열성 절연재료의 상시운전온도($110{\circ}C$), 비상시 운전온도($130{\circ}C$)을 바탕으로 하여 열 열화 온도와 기간이 설정되었다. 열 열화는 자연순환 건조기에서 설정된 온도와 기간 동안 수행되었고, 열 열화된 고내열성 절연재료는 Mckewon전극을 이용하여 AC파괴 시험이 진행 되었다. 파괴시험데이터는 와이블 분포함수를 이용하여 통계적으로 분석되었다.

  • PDF

생쥐의 초기 미란성위궤양 상피세포의 미세구조 변화 및 분비면역계에 대한 연구

  • Ha, Mi-Hye;Choe, Eun-Sang;Ha, Jae-Cheong
    • The Korean Journal of Zoology
    • /
    • v.35 no.1
    • /
    • pp.45-57
    • /
    • 1992
  • 생쥐를 48시간 동안 결식시킨 후 유문결찰하여 급성미란을 유발시키고 미란형성부의 점막 내위선을 구성하는 각 세포의 구조변화와 IgA 분비세포의 분포를 관찰하였다. 미란부 점액분포의 변화는 표면상피의 손상 정도가 심해질수록 경계부의 PAS양성반응은 감소되었으며 중심부에서는 표면상피의 소실로 인하여 PAS 양성반응이 관찰되지 않았다. Glycocalyx 관찰을 위한 ruthenium red 반응에서도 경계부의 상피세포 손상이 심해짐에 따라 정단세포막 상층에 나타나는 양성반응은 감소되었고 측면과 기저면의 양성반응은 관찰되지 않은 것으로 보아 세포 손상시 tight junction은 파괴되지 않음을 알 수 있었다. 미란경계부의 미세구조변화로서, 상피세포는 손상이 진행될수록 세포질이 용해되어 공포가 형성되고 핵응축 및 정 단세포질의 점액원과립의 소실이 관찰되었으나 tight junction은 유지되었다. 반면에 점액경세포는 점액원과립의 수가 증가되고 조면소포체가 종창되어 있었다. 미란의 경계부와 중심부에서 벽세포는 다수의 소포가 출현한 후 세포내세관이 종창되었으며 그 후에 mitochondria가 파괴되었고 주세포는 주변의 벽세포가 커지면서 가장자리로 밀려나 크기가 정상보다 작아지고 조면소포체와 mitochondria가 종창을 나타내었다. IgA분비세포는 점막이 파괴된 미란부 점막하조직의 혈관 주변에 다수 존재하는 형질세포에서 확인되었다.

  • PDF

Plastic Hinge Length of Reinforced Concrete Columns with Low Height-to-Width Ratio (전단경간비가 작은 철근콘크리트 기둥의 소성힌지 길이)

  • Park, Jong-Wook;Woo, Jae-Hyun;Kim, Byung-Il;Lee, Jung-Yoon
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.5
    • /
    • pp.675-684
    • /
    • 2010
  • The reinforced concrete members are designed to fail in flexural to lead ductile fracture. In the building structures, the failure is typically imposed on beams to prevent damages in columns. However, progression of plastic collapse mechanism may ultimately develop, a plastic hinge at the bottem end of the first floor column, which then can be subjected to shear or bond finally due to large axial force and small shear span-to-depth ratio. In this study, 10 RC column specimens failed in shear after flexural yielding was investigated to determine the factors affecting the plastic hinge length. The findings of this study showed that the most effective factor affecting the plastic hinge length was an axial force. As an axial force increase, an axial strain and a ductility ratio were decreased obviously. The test also shows the observed plastic hinge length was about 0.8~1.2d and the this result has difference compared with forward research.

Preparation of Polyolefin Hollow Fiber Membranes and Their Applications (폴리올레핀계 고분자 중공사막의 제조 및 응용)

  • 김진호;박민수;장문석;김성수
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.154-154
    • /
    • 2003
  • 세계의 특허동향을 분석해 보면 수처리용 MF/UF 분리막의 제조 및 응용에 관한 연구개발이 매우 활발하게 진행되어져 왔음을 알 수 있다. 또한 다국적 기업들의 적극적인 마케팅과 분리막 공법의 우수한 처리효율이 인정되면서 90년대 후반부터는 수십만톤/일 규모의 징수처리 및 하수고도처리 분야에까지 MF/UF 분리막이 괄목할만한 수요의 증대를 보이고 있으며 이러한 추세는 앞으로도 더욱 확대될 것으로 전망이 되고 있다. 고분자재료를 이용하여 MF/UF 분리막을 제조하는 방법으로는 보편적으로 첫째, 고분자를 용매에 녹인 후 용매와 비 용매간의 상호교환을 유도하여 분리막을 제조하는 상전이법(Phase Inversion). 둘째, 고분자를 고온에서 희석제와 melt-blending 한 후 가해진 열을 제거하면서 상분리를 일으켜 다공성을 부여하는 열유도 상분리법(TIPS, Thermally Induced Phase Separation). 셋째, 결정성 고분자를 용융, 압출 및 냉각하여 결정화도가 매우 높은 전구체를 제조한 후 연신에 의해 비결정 영역을 개열시켜 기공을 형성하는 연신법(Stretching process)이 있다. 이 중 물성이 매우 우수한 폴리올레핀계 결정성 고분자를 이용하여 분리막을 제조할 수 있는 방법은 열유도 상분리법 및 연신법에 제한된다. 본 연구 발표에서는 세계적으로도 극소수의 기업들만이 보유하고 있으며 고도로 축적된 노하우를 필요로 하는 열유도 상분리법 및 연신법에 의하여 폴리프로필렌 및 폴리에틸렌 중공사막을 제조하는 방법과 이 두 가지 방법에 의해서 제조된 중공사막의 구조, 물성 및 수투과 성능 그리고 KMS 중공 사막의 응용사례를 통한 실제 운전특성 등을 소개하고자 한다.좋은 결과를 가져다 주는 술식으로 판단되었다.결과를 이용하여 향후 전개될 홈 네트워크 서비스 및 관련시장의 발전 방향을 전망해 보고 이에 따른 기업이나 정부차원의 대응전략을 파악하고자 한다.육구에서는 큰 변화를 나타내고 있지 않았다(p<0.05). 운동과 비운동시킨 참돔의 지질 함량의 변화는 운동시킨 참돔은 운동으로 인한 에너지 소비로 인하여 함량이 유의적으로 감소했으며(r=-0.35), 비운동사육구에서는 절식으로 인하여 지질함량이 감소하였다(r=-0.38). 파괴강도와 가장 밀접한 영향을 가지는 콜라겐은 운동과 비운동 모두 사육기간동안 큰 변화는 보이지 않았다. 초기의 파괴강도값은 1.45±0.02kg(운동사육구), 1.36±0.18kg(비운동사육구)이였으며 사육기간동안 운동사육구는 파괴강도값이 증가한 반면, 비운동수조에서는 참돔의 파괴강도는 사육기간동안 큰 유의차가 없었다. 각 성분간의 상관도를 살펴보면, 수분함량과 파괴강도는 상관성을 가졌으며, 지질함량과 파괴강도도 같은 경향은 나타내었다. 운동기간동안의 파괴강도와 콜라겐 사이에는 상관성의 거의 없었다. 이는 운동기간에 따른 파괴강도의 증가가 콜라겐의 함량의 증가보다는 지질함량의 감소와 수분함량의 증가와 같은 성분과의 상관성이 크다고 판단된다. 다음으로는, 운동횟수에 의한 영향으로써 운동시간을 1일 6시간으로 설정하여, 운동횟수를 결정하기 위하여 오전, 오후에 각 3시간씩 운동시키는 방법과 오전부터 6시간동안 운동시키는 두 방법을 이용하여 품질을 비교하였다. 각 조건에 따라 운동시킨 참돔의 수분함량을 나타낸 것으로, 2회(오전 3시간, 오후 3시간)에 나누어서 운동시키기 위한 육의 수분함량은 73.37±2.02%를 나타냈으며, 1회(6시간 운동)

  • PDF

하부 기관개구창 재건을 위한 대흉근 피판의 이용

  • 김진환;노영수;안회영
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 2003.09a
    • /
    • pp.109-109
    • /
    • 2003
  • 성문 하방으로 진행된 후두암이나 하인두암, 기관의 침범이 있는 갑상선암 혹은 기공주변 재발암 등의 경우에 적절한 절제연을 얻기 위하여 상부기관륜 일부의 절제가 불가피하며 이때 만들어지는 영구 기관개구창은 일반적인 기관개구창에 비하여 하부에 위치하게 되며 보다 하부로의 기관 절제가 필요한 경우 기관과 주위 피부와의 봉합이 힘들고 경우에 따라서는 종격동 기관개구창을 만들어야 할 경우도 있다. 그리고 기관주위의 림프절이나 상부종격동 림프절 청소술을 병행한 경우나 후두전절제술 후 인두피부누공에 의한 창상감염이 생긴 경우, 기관주위 조직의 제거 후에 노출된 중요혈관의 보호와 광범위하게 제거된 결손부위를 덮기 위해 재건이 필요하게 된다. 대흉근피판은 혈관경이 일정하고 혈액 공급이 풍부하여 감염이 있거나 재건 후 감염을 방지하는데 사용될 수 있으며 피판 경의 길이가 대부분의 두경부 부위에 도달할수 있을 정도로 길고 근육의 부피가 충분하여 결손부위가 넓은 경우에 유용한 장점이 있다. 특히 종격동 림프절 청소술 후에나 하부 기관공의 재건을 위하여서는 한 수술시야에서 시행할 수 있는 인접한 부위 근피판 이라는 장점이 있고 필요시에는 이중도서(double-island) 형태로 접어서 이중피판으로 사용할 수도 있으며 피부이식과 병용하면 경부 피부의 재건도 동시에 시행할 수 있다. 저자들은 광범위한 기관륜의 제거 후 영구 기관개구창이 경부 하방이나 흥부 상부에 위치하게 되어 안쪽으로 말려들어가는 기관개구창 주변부위와 기관주위 결손 부위의 재건, 그리고 무명 동맥 등의 중요 구조물의 보호를 위해 사용된 대흉근 피판의 여러 작도법(design)과 응용, 결과를 종합하여 하부 기관개구창 재건에 있어 대흉근피판의 유용성을 살펴보고자 하였다. 한다. 본 연구의 결과를 이용하여 향후 전개될 홈 네트워크 서비스 및 관련시장의 발전 방향을 전망해 보고 이에 따른 기업이나 정부차원의 대응전략을 파악하고자 한다.육구에서는 큰 변화를 나타내고 있지 않았다(p<0.05). 운동과 비운동시킨 참돔의 지질 함량의 변화는 운동시킨 참돔은 운동으로 인한 에너지 소비로 인하여 함량이 유의적으로 감소했으며(r=-0.35), 비운동사육구에서는 절식으로 인하여 지질함량이 감소하였다(r=-0.38). 파괴강도와 가장 밀접한 영향을 가지는 콜라겐은 운동과 비운동 모두 사육기간동안 큰 변화는 보이지 않았다. 초기의 파괴강도값은 1.45±0.02kg(운동사육구), 1.36±0.18kg(비운동사육구)이였으며 사육기간동안 운동사육구는 파괴강도값이 증가한 반면, 비운동수조에서는 참돔의 파괴강도는 사육기간동안 큰 유의차가 없었다. 각 성분간의 상관도를 살펴보면, 수분함량과 파괴강도는 상관성을 가졌으며, 지질함량과 파괴강도도 같은 경향은 나타내었다. 운동기간동안의 파괴강도와 콜라겐 사이에는 상관성의 거의 없었다. 이는 운동기간에 따른 파괴강도의 증가가 콜라겐의 함량의 증가보다는 지질함량의 감소와 수분함량의 증가와 같은 성분과의 상관성이 크다고 판단된다. 다음으로는, 운동횟수에 의한 영향으로써 운동시간을 1일 6시간으로 설정하여, 운동횟수를 결정하기 위하여 오전, 오후에 각 3시간씩 운동시키는 방법과 오전부터 6시간동안 운동시키는 두 방법을 이용하여 품질을 비교하였다. 각 조건에 따라 운동시킨 참돔의 수분함량을 나타낸 것으로, 2회(오전 3시간, 오후 3시간)에 나누어서 운동시키기 위한 육의 수분함량은 73.37±2.02%를 나타냈으며, 1회(6시간 운동)운동시키기 위한 육은 71.74±1.66%을 나타내

  • PDF

Construction of Vegetation Information Management System Using GIS (GIS를 이용한 식생정보 통합관리시스템 구축 방안)

  • Song, Ji Hye;Kang, In Joon;Hong, Soon Heon;Park, Dong Hyun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.4
    • /
    • pp.99-106
    • /
    • 2014
  • After 1960 forest and ecosystem are rapidly destroyed by industrialization and urbanization. Accordingly, studies that produce vegetation map continue for forest and ecosystem management. Since 1986 national natural environment survey is being conducted in Korea. Also, vegetation information is managed properly through forest geospatial information service(FGIS) of the Department of Environment when NGIS project was promoted since 1995. But it provide dominant species information based on text. In particular, some vegetation information dose not provide to end-user. Therefore, we suggest construction method of vegetation information management system based on GIS to solve the problem. Also, we suggest connection method of related system for an accurate analysis, planning and decision-making support.

Comparsions for Flexural Performance of Amorphous Steel Fiber Reinforced Concrete (비정질강섬유보강콘크리트의 휨성능 비교분석)

  • Kim, Byoung-Il;Lee, Sea-Hyun
    • Resources Recycling
    • /
    • v.24 no.3
    • /
    • pp.66-75
    • /
    • 2015
  • The flexural performance of amorphous steel fibers having environmental and economy benefits due to relatively short manufacturing process were evaluated as well as that of hooked steel fibers by varing fiber length and volume fraction. Fiber lengths were 10 mm, 20 mm, 30 mm and fiber volume fractions were varied from 0.3% to 1.2%. Test results with flexural performance showed that mixing design needs to be careful because of relatively high volume of amorphous steel fiber compared to hooked steel fibers. High flexural strength was obtained from both longer fiber length and higher volume fraction. Residual strength and toughness of amorphous steel fiber were similar to that of hooked steel fiber, even though rapid dropping of applied load right after concrete matrix breaking. It can be judged that relatively high ability of energy dissipation around first cracking area relatively overcome rapid dropping of loading.