• Title/Summary/Keyword: 투과광

Search Result 1,175, Processing Time 0.035 seconds

Acquisition of High Resolution Images and its Application using Synchrotron Radiation Imaging System (방사광 X-선을 이용한 고해상도 영상획득과 응용)

  • 홍순일;김희중;정해조;홍진오;정하규;김동욱;제정호;김보라;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2001
  • Synchrotron radiation (SR) has several advantages over convetional x-rays, including its phase, collimation, and high flux. A synchrotron radiation beamline 5C1 at Pohang Light Source (PLS) was recently built for imaging applications. We have shown that a SR imaging system is useful in imaging microscopic structures. SR with broad-band energy spectrum were adjusted to an object by Si wafers and their energy were approximately ranging from 6 keV to 30 keV. SR were passed through an object and finally transformed into visible lights by CdWO$_4$ scintillator screen. The visible lights which were reflected at an angle of 90 degrees by gold plated mirror were detected by a CCD camera and the image data were acquired using image acquisition system. A high-resolution phantom, capacitor, adult tooth, child tooth, cancerous breast tissue, and mouse lumbar vertebra were imaged with SR imaging system. The Objects were rotated within the field of view of the CCD detector, and their projection image data were obtained at 250 steps over 180 degrees rotation. Image reconstructions were carried out in a PC by using IDLTM(Research systems, Inc., US) program. The spatial resolution of the images acquired by the SR imaging system was measured with a high-resolution chart manufactured for several micrometer resolution. The specimens were also imaged with conventional x-ray radiography system to compare the image quality of radiography obtained with the SR imaging system. The results showed more structural details and high contrast images with SR imaging system than conventional x-ray radiography system. The SR imaging system may have a potential for imaging in biological researches, material applications, and clinical radiography.

  • PDF

Design of PWM-Based Photo Irradiation System for Acne Treatment (여드름 치료를 위한 PWM 기반 광 조사 시스템 설계)

  • Kim, Chang-Su;Lim, Hyun-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.3
    • /
    • pp.207-215
    • /
    • 2012
  • As one of photo dynamic therapies, the existing LED photo irradiation method with 635 nm continuous wave has most frequently been used for acne treatment, it suffered from a low energy efficiency and generation of a large amount of heat in tissues requiring improvement measures. In this thesis, a LED photo irradiation system for acne treatment has been designed using PWM(Pulse Width Modulation) mode to enhance the energy efficiency and prevent thermal destruction in tissues. System configuration consisting largely of timer module, PWM module, and photo transfer device has been designed with the use of 1 W LED at a wavelength of 660 nm for the photo transfer device to increase skin penetration depth for treatment of acne. Frequency and wave form generated by using PWM control was verified along with confirmation of output energy of 660 nm LED and surface temperatures of tissues, followed by evaluation of stable energy outputs and stability of tissues. The results indicated that whereas power loss was high and thermal destruction in tissues was exhibited when C.W mode was used to obtain the optical energy of 1 W LED at a wavelength of 660 nm for acne treatment, realization of PWM mode allowed lowering of power consumption for LED through pulse width modulation, and no occurrence of thermal destruction in tissues, suggesting that PWM mode is safer and more effective for treatment of acne than C.W mode.

Optical and electrical properties of AZO thin films deposited on OHP films (OHP 필름위에 증착된 AZO 반도체 박막의 광학 및 전기적인 특성 분석)

  • Kim, Kyoung-Bo;Lee, Jongpil;Kim, Moojin
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.9
    • /
    • pp.28-34
    • /
    • 2020
  • In this paper, an optical sensor based on an AZO semiconductor material is fabricated on an OHP film with high transmittance, and the characteristics of the optical element and the properties of the semiconductor material are described. In order to realize a flexible optical device, which is a major issue in the field of near-electronic devices, a transparent and bendable OHP film was used as a substrate. In addition, ITO, which is used for mass production as a transparent electrode and a semiconductor material, is expensive due to the scarcity of indium. Therefore, it is necessary to find a material that can replace it. The optical and electrical properties of the Au/Al/AZO/OHP structure are implemented to evaluate whether AZO is possible. It was found that devices and materials had no characteristic change by bending, and these results provide a possibility for application to a next-generation device. However, it is necessary to remove fine scratches on the surface of the OHP film, as well as optimized devices based on materials and structures that can improve the photocurrent.

Occurrence of Micro-cracking According to Bagging Paper in 'Mansoo' Pear Fruits (과실 봉지에 따른 배 '만수' 품종의 미세 열과 발생)

  • Choi, Jin-Ho;Yim, Sun-Hee;Kim, Sung-Jong;Lee, Han-Chan;Kwon, YongHee
    • Horticultural Science & Technology
    • /
    • v.33 no.4
    • /
    • pp.479-485
    • /
    • 2015
  • This study was conducted to study the factors inducing micro-cracking and determine proper practices to reduce its occurrence in 'Mansoo' pear fruits. Micro-cracking was observed on ripe fruits. Occurrence of micro-cracking was closely related to sun duration time in August. Micro-cracking occurred severely with shorter sun duration, but weakly with longer sun duration and continuous sunlight. Micro-cracking fruits occurred more frequently in trees with a pergola training system than in those with Y-trellis, but there was no difference between the irrigated and non-irrigated groups. While no micro-cracking was observed without fruit bagging, micro-cracking occurred in fruits with black and yellow outer paper bagging at rates of 62.2 and 17.3%, respectively. Our results suggest that the light condition was the most important cause of micro-cracking because the occurrence of micro-cracking in 'Mansoo' fruits was affected by factors including sun duration, trellis system and fruit bag color. We suggested that micro-cracking could be reduced in 'Mansoo' fruit by optimizing the light conditions with the proper trellis system, bagging color and summer pruning.

Polymer Eyeglass Lens with Ultraviolet & High-Energy Visible Light Blocking Function for Eye Health (자외선 및 고에너지 가시광 차단 기능을 갖는 눈 건강을 위한 폴리머 안경렌즈)

  • Kim, Ki-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.10-15
    • /
    • 2020
  • Ultraviolet rays, which have wavelengths smaller than 400 nm, are very harmful to the eyes. Recently, high-energy visible light was also revealed to be harmful to retinal cells. Therefore, polymer eyeglass lenses that can block UV and high-energy visible light are needed for eye health. In this study, high-refractive-index polymer eyeglass lens, n=1.67, were manufactured using the injection-mold method with the m-xylene diisocyanate monomer, 2,3-bis((2-mercaptoethyl)thio)-1-propanethiol monomer, benzotriazole UV absorber, release of alkyl phosphoric ester, dye mixture of CI solvent violet 13, and catalyst of dibutyltin dichloride mixture. A multi-layer anti-reflection coating was applied to manufactured polymer eyeglass lenses for both sides using an E-beam evaporation system. The optical properties of the manufactured lenses with the UV and high-energy visible light-blocking function were analyzed by UV-visible spectrophotometry. As a result, the polymer eyeglass lens with a UV absorber of 0.5 wt. % blocked 99% of UV and high-energy visible light shorter than 411 nm. The average transmittance of the polymer eyeglass lens with a UV absorber of 0.5wt.% was 97.9% in the range of 460 ~ 660 nm for photopic eye sensitivity higher than 10%. Therefore, clear image acquisition in photopic vision is possible.

A COMPARATIVE STUDY ON RADIOPACITY OF CANAL FILLING AND RETROGRADE ROOT-END FILLING MATERIALS (근관 충전재 및 치근단 역충전재의 방사선 불투과성에 관한 비교 연구)

  • Kim, Yong-Sang;Kim, Seo-Kyong;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.107-114
    • /
    • 2008
  • This study was performed to assess the radiopacity of a variety of canal filling and retrograde root-end filling materials according to the specification concerning root canal obturation materials. Ten materials including Gutta-percha pellets, amalgam, Fuji II LC, $Dyract^{(R)}$ AP, Super $EBA^{(R)}$, $IRM^{(R)}$, AH $26^{(R)}$, $Sealapex^{TM}$, Tubli-$Seal^{TM}$, and dentin were evaluated in this study. In the first part, densitometric reading of an each step of aluminum step wedge on occlusal film were performed at 60 kVp (0.2, 0.3, 0.4 s), 70 kVp (0.2, 0.3, 0.33 s) to decide appropriate voltage and exposure time. In the second part, ten specimens which are 5 mm in diameter and 0.5, 1.0, 1.5, 2.0, 2.5, 3.0 mm in thickness, were fabricated from each material studied. The specimens were radiographed simultaneously with an aluminum step wedge under decided condition (60 kVp, 0.2 s). The mean radiographic density values of the materials were transformed into radiopacity expressed equivalent thickness of aluminum (mm Al). The following results were obtained. 1. Among the various conditions including 0.2 s, 0.3 s, 0.4 s at 60 kVp and 0.2 s, 0.3 s, 0.33 s at 70 kVp, the appropriate voltage and exposure time that meet the requirement of density from 0.5 to 2.0 was 0.2 s at 60 kVp. 2. All of the materials in this study had greater radiopacity than the minimun level recommended by ISO No. 4049 standards. 3. Most of the materials had greater radiopacity than 3 mm Al requirement of ANSI/ADA specification No. 57 (2000) and ISO No. 6876 (2001) standards except for Fuji II LC and Dyract. It suggests that all experimental canal filling and retrograde root-end filling materials have a sufficient radiopacity that meet the requirement concerning root canal obturation materials except for Fuji II LC and Dyract.

The Fabrication and Characteristic for Narrow-band Pass Color-filter Deposited by Ti3O5/SiO2 Multilayer (Ti3O5/SiO2 다층박막를 이용한 협대역 칼라투과필터 제작 및 특성연구)

  • Park, Moon-Chan;Ko, Kyun-Chae;Lee, Wha-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.357-362
    • /
    • 2011
  • Purpose: The narrow-band pass color-filters with a 500 nm central wavelength and 12 nm FWHM using $Ti_3O_5/SiO_2$ mutilayer were fabricated, and their characteristics and structures were studied. Methods: the optical constants, n and k, of the $Ti_3O_5$ and $SiO_2$ thin films were obtained from the transmittances of their thin film. The narrow-band pass color-filters were designed with these optical constants and the AR coating of the filter was also designed. $Ti_3O_5/SiO_2$ multilayer filters were made by electron beam evaporation apparatus and the transmittaces of the filters were measured by spectrophotometer. the number of layers and the thicknesses of filters were calculated from the cross section of filters by SEM image and the composition of filters was analysed by XPS analysis. Results: The optimization of AR coating for the narrow-band pass color-filter was [air$|SiO_2(90)|Ti_3O_5(36)|SiO_2(5)|Ti_3O_5(73)|SiO_2(30)|Ti_3O_5(15)|$ glass], and the optimization of filter layer for the color filter was [air$|SiO_2(192)|Ti_3O_5(64)|SiO_2(102)|Ti_3O_5(66)|SiO_2(112)|Ti_3O_5(74)|SiO_2(120)|Ti_3O_5(68)|SiO_2(123)|Ti_3O_5(80)|SiO_2(109)|Ti_3O_5(70)|SiO_2(105)|Ti_3O_5(62)|SiO_2(99)|Ti_3O_5(63)|SiO_2(98)|Ti_3O_5(51)|SiO_2(60)|Ti_3O_5(42)|SiO_2(113)|Ti_3O_5(88)|SiO_2(116)|Ti_3O_5(68)|SiO_2(89)|Ti_3O_5(49)|SiO_2(77)|Ti_3O_5(48)|SiO_2(84)|Ti_3O_5(51)|SiO_2(85)|Ti_3O_5(48)|SiO_2(59)|Ti_3O_5(34)|SiO_2(71)|Ti_3O_5(44)|SiO_2(65)|Ti_3O_5(45)|SiO_2(81)|Ti_3O_5(52)|SiO_2(88)|$ glass]. It was known that the color-filters fabricated by the simulation data were composed of 41 layers by SEM image and the top layer of filters was $SiO_2$ layer and the filters were composed of $SiO_2$/$Ti_3O_5$ multilayer by XPS analysis. It was also known that the mixed thin film of TiO2 and $Ti_3O_5$ was made during the deposition of the $Ti_3O_5$ material. Conclusions: The narrow-band pass color-filters with a 500 nm central wavelength and 12 nm FWHM using $Ti_3O_5/SiO_2$ mutilayer of 41 layer were fabricated, and it was known that the mixed form of TiO2 and $Ti_3O_5$ thin film was made during the deposition of the $Ti_3O_5$ material.

Polymerization of HEMA by Electron beam Irradiation and Fabrication of Soft contact lens (전자빔조사에 의한 HEMA의 중합과 소프트콘택트렌즈 제조)

  • Hwang, Kwang-Ha;Shin, Joong-Hyeok;Sung, Yu-Jin;Jeong, Keun-Seung;Jun, Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.135-141
    • /
    • 2012
  • Purpose: Polymerization of HEMA(2-hydroxyethyl methacrylate) which can be used in the soft contact lens has been performed by using electron beam(EB) irradiation, and examined the best condition for the polymerization. Comparing the physical properties of the contact lenses to the one fabricated by thermal polymerization method, we check the use possibility of the EB irradiation to the fabrication of the soft contact lens. Methods: We investigated the degree of polymerization of the HEMA according to the composition of the monomer, the additive ratio and the dose of electron beam (0~120 kGy). The degree of polymerization was measured depending on the EB dose to research the best synthetic condition under the EB irradiation. The physical properties of the contact lens such as water content(%), oxygen transmissibility(Dk/t) and optical transmittance were analysed by using the FT-IR results with comparing the two different polymerization method (thermal and electron beam polymerization) with same additive ratio. Results: When the dose of electron beam was above 100 kGy, the degree of polymerization of HEMA was above 99% with regardless using cross-linker and initiator. The water content of the lens fabricated by EB method showed 10% higher than the one by the thermal method which was 40%. The lens fabricated by EB method also showed higher oxygen transmissibility(Dk/t) as same with the water content, and showed twice higher value in the lens fabricated by pure HEMA. According to the FT-IR results, hydrophilic property of the lens fabricated by EB method was increased due to increasing the intermolecular hydrogen bonding. It showed above 90% optical transmittance in the visible range of wavelength on the contact lenses fabricated by the both of two different polymerization method. Conclusions: The polymerization of HEMA without cross-linker and initiator was successful above 100 kGy of EB irradiation. Moreover the lens fabricated from the polymer synthesized by pure HEMA with 100 kGy of EB showed the highest water content and oxygen transmissibility. Therefore EB irradiation is another possible method to synthesize the polymer which can be used for the soft contact lens.

COMPARATIVE STUDY ON THE EARLY DETECTION OF ENAMEL LESIONS USING DIFOTI AND LASER FLUORESCENCE (Digital Imaging Fiber-Optic Trans-Illumination과 Laser Fluorescence를 이용한 법랑질 우식증의 조기 진단에 관한 비교 연구)

  • Maeng, Myoung-Ho;Kim, Seung-Oh;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.207-220
    • /
    • 2006
  • The newly developed equipments for the early detection of carious lesion are LFD (laser fluorescence device), Ultrasonic diagnostic system, CLSM(confocal laser scanning microscopy), QLF(quantitative light-induced fluorescence) and DIFOTI (digital imaging fiber-optic trans-illumination) system. In this study, DIFOTI system and LFD were used for the detection of early enamel caries. Twenty five primary teeth extracted from twenty one children at around the dentitional exchanging period were selected as samples. The results obtained from DIFOTI imaging and LFD measurement were compared with those of CLSM and comprehensive evaluations were made for the diagnostic capacity of each device. In vitro test, 40 sample teeth with their buccal & lingual surface formed by a window of $2{\times}3mm$ in diameter were immersed in artificial demineralizing solution for the period of 4, 8, 12 and 16 days. The results obtained from the experimental groups (DIFOTI, LFD) were compared to control group (CLSM) and we have reached to the following conclusions. 1. The sensitivity and specificity of DIFOTI system operated in oral environment was 88.2% and 76.9% respectively. 2. The sensitivity and specificity of LFD measured in oral environment was 76.5% and 69.2% respectively. 3, Regression analysis on the light transparent rate of DIFOTI showed its decrease according to the length of primary enamel decalcification performed in vitro(r=-0.96, p<0.05). 4. No statistically significant difference between LFT measurement and the length of in vitro decalcification was found in regression analysis (p>0.05). 5. The correlation coefficient of DIFOTI image transparent rate and the lesion depth of CLMS was -0.6988 (p<0.05), whereas no statistically significant difference was found for LFD measurement.

  • PDF

Effect of Multi-wall Carbon Nanotube Surface Treatment on the Interface and Thermal Conductivity of Carbon Nanotube-based Composites (다중벽탄소나노튜브 복합재료의 계면 및 열전도도에 표면처리 방법이 미치는 영향)

  • Yoo, Gi-Moon;Lee, Sung-Goo;Kim, Sung-Ryong
    • Journal of Adhesion and Interface
    • /
    • v.11 no.4
    • /
    • pp.174-180
    • /
    • 2010
  • The effect of carbon nanotube surface treatment on the interface and thermal conductivity of carbon nanotube-based poly(methylmethacrylate) (PMMA) composites was investigated. Coagulation and atomic-transfer radical polymerization (ATRP) was applied to modify the surface of multi-wall carbon nano-tube. The composite of ATRP method used carbon nanotube showed the higher transparency and thermal conductivities than that of the coagulation method used. In comparison to the thermal conductivity of pure PMMA, 0.21 W/mK, the ATRP carbon nanotube used PMMA/MWNT composite showed a thermal conductivity of 0.38 W/mK. The interface between carbon nanotube and PMMA was observed by scanning electron microscope and uniform dispersion of carbon nanotube was observed without any void in the PMMA matrix. It may be beneficial to transport the phonon without any scattering and it may result in a higher thermal conductivity.