• Title/Summary/Keyword: 통신케이블

Search Result 513, Processing Time 0.023 seconds

Examination of Conductor and Sheath Temperatures Dependent on the Load Currents through High-Power Live Cables at a Power Station (발전소에서 활선 고전력 케이블의 운전 부하전류에 따른 도체 및 피복표면의 온도 분석)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.1
    • /
    • pp.213-218
    • /
    • 2017
  • High-voltage power systems operate in order to generate and transmit electric power at power stations. Compared to low-power systems, high-power systems are complex in structure, large-scale, and expensive. When high-power cable accidents occur, most facilities are incapacitated-including low-power systems-causing huge economic losses. Great care must therefore be taken in designing, installing and managing power systems. Although dependent on installation circumstances and usage conditions, in some cases the cross-sectional areas of cables fall short of the critical area due to the expansion of and improper design and installation of power facilities. In this situation, the exceeded ampacity (allowable current) above the critical value caused by the operating current initiates the deterioration processes of power cables. In order to systematically monitor power cables operating at power stations, we have developed the first device of its kind in Korea. In this paper, we present the analyzed characteristics of expected temperatures of cables based on the load current of high-voltage cables operating at Korean Western Power Co. Ltd. We can predict the lifetime of cables by analyzing the temperature obtained from our device.

Traction device designed to collect data on underground cabling with threaded rope double braided (더블 브레이디드 로프를 이용한 지중 케이블 포설시 견인 데이터 수집 장치 설계)

  • Lee, Bae-Kyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.7
    • /
    • pp.1623-1629
    • /
    • 2015
  • By increasing due to large-scale residential and commercial apartments or factories or were, and increases the length of the cable is connected from the electrical room, the thickness of the cable, the trend is also being gradually thicker to increase the power consumption. In this paper, the programs install the cable inserted in the rope a double bonded brake pipe to be laid underground in these cables, and to reliably collect various kinds of data such as a tension at the time of laying the cable, the distance and speed design, and the sample data was acquired through hardware making them. Through this, it was confirmed that, worker was significantly reduced and work time was shortened to the traditional mechanical laying equipment. And to obtain a performance of improving the reliability of operation, because the use of the working data to the management and evaluation.

A Study on the Calculation of Allowable Continuous Current for HVDC Submarine Power Cables (HVDC 해저케이블의 연속허용전류 계산에 관한 연구)

  • Lim, Chung-Hwan;Park, Hung-Sok;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.5
    • /
    • pp.815-824
    • /
    • 2022
  • The growing integration of intermittent renewable sources like offshore wind energy increases the need for transferring electric energy over long distances, which may include sea crossings. One of the solutions available for bulk electric power transmission across large distances encompassing wide and deep sea is using HVDC submarine power cables. However, there are no standards or research related to the calculation of the continuous allowable current with various ocean conditions of a DC power cable that does not have an alternating magnetic field. In this study, assuming the typical two types of subsea cable models and two areas of the south coast and the west coast marine conditions, a continuous allowable current simulation of DC cables was performed. As a simulation result, the DC cable continuous allowable current find out the gradient reduction characteristics based on subsea base depth.

Analysis of Monitored Insulation Data Using Standard Deviation of Leakage Current Data in High-Power Cables at a Thermoelectric Power Station (화력발전소 고전력 케이블의 누설 전류 측정 데이터의 표준 편차값을 사용한 절연감시 데이터 분석)

  • Kim, Bo-Kyeong;Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.2
    • /
    • pp.245-250
    • /
    • 2017
  • From the instant of installation and operation, power cables start deteriorating. Cable systems can be maintained not only by monitoring the insulation status of the insulation layer and oversheath, but also the insulation status of the terminal and junction in high-voltage power cables. When the cable system (the cable itself and cable junctions combined) deteriorates, fire accidents happen due to dielectric breakdowns. We have invented a device to monitor the deteriorating status of cables, and installed it at Korea Western Power Co. Ltd. located in Taean, Chungcheongnam-do Province. In this paper, we present the results obtained using our device, through analysing and calculating the standard deviation of leakage current from cable insulators attached to the cables. When the standard deviation of analysed leakage current falls below a critical value, a cable system is deemed to be operating safely. But when the standard deviation of analysed leakage current is larger than the critical value, the insulation status of the terminal and junction in the cable system is considered to have seriously deteriorated. The terminal and junction in the relevant system should then be replaced preemptively in order to prevent blackout accidents of cables caused by the suspension of power supply.

Electromagnetic Susceptibilty design of High-Speed Image Signal Processing Unit for Small Infrared Image Homing sensor (적외선 영상 호밍센서 고속 영상신호처리기의 전자기파 내성 설계)

  • Kim, Hong-Rak;Park, Jin-Ho;Kim, Kyoung-Il;Jeon, Hyo-won;Shin, Jung-Sub
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.2
    • /
    • pp.27-33
    • /
    • 2022
  • The small infrared image homing sensor is the eye of a guided weapon that has an infrared image sensor that identifies a target on the ground through day and night infrared image processing and searches, detects, and tracks the target. Inside the guided weapon since the power supply and communication line are used together with various components, the part against electromagnetic wave interference is very important. In particular, the effect of CE (Conducted Emission) through the power and communication lines connected by cables is very important. Through this method, it is possible to directly affect other components of the guided weapon. In this paper, the EMI filter and cable design for avoiding electromagnetic interference to the power input through the cable and the communication line are described. Also, the designed EMI filter is manufactured After the CE102 test of MIL-STD-461G, design satisfaction will be explained.

Interface Conversion to Extend Communication Cable of Ultrasonic Sensor (초음파 센서 통신선 연장을 위한 인터페이스 변환)

  • Seo, Dae-Il;Kwon, Byung-Hyuk;Kim, Sang-Jin
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.3
    • /
    • pp.467-472
    • /
    • 2022
  • The 3D ultrasonic anemometer transmits measured data by connecting PC and RS232C interface. Depending on the observation location, it is often necessary to extend the cable connecting the PC and the sensor. When installing on the test bed of the Air Meteorological Agency, the original AWM2919 cable was required to be extended because the distance between the PC container and the equipment installation site was more than 30 m. The cable was extended through a process such as extending the AWM2919 cable, converting the interface with the PC from RS232C to RS485, and testing the RS485 communication. After the equipment was installed with an extended cable, data were remotely collected and analyzed to confirm successful cable extension.

케이블기반 n-Screen 서비스

  • Kim, Hong-Ik;Lee, Sang-Yong
    • Broadcasting and Media Magazine
    • /
    • v.16 no.1
    • /
    • pp.102-114
    • /
    • 2011
  • 새로운 스마트 디바이스들이 광대역 네트워크와 연결되면서 방송 통신 서비스 가치사슬에 많은 변화가 나타나고 있다. 이들 변화 중에서 콘텐츠 소비의 변화는 스크린에 관계없이 서비스를 제공하는 n-Screen 서비스로 이어지고 있다. 케이블 사업자는 대부분 지금까지 고정된 장소에서 TV라는 스크린을 통해 콘텐츠 서비스를 해왔지만 이러한 환경변화에 대응이 필요하다. 케이블에서 콘텐츠 소비 확산과 서비스 경쟁력 확보 등을 위한 n-Screen 서비스를 제공하는 방법은 크게 서버기반, 케이블모뎀 기반, 게이트웨이 기반, 클라우드 기반으로 나눌 수 있다. 본 기고에서는 케이블기반 n-Screen 서비스 방법간에 비교 설명과 서비스를 위한 고려사항들에 대해서 설명하고자 한다. 시장환경에 대한 판단과 사업환경에 따라 사업자들은 다른 선택을 할 수 있지만 사용자의 서비스 경험을 연장하고 사용자의 콘텐츠도 수용하는 방향이 적절하다.