• Title/Summary/Keyword: 토양 성능

Search Result 266, Processing Time 0.03 seconds

Assessment of Soil Stabilization forthe Reduction of Environmental Risk of Lead-contaminated Soil Near a Smelter Site (제련소 주변 납 오염 현장토양의 위해성 저감을 위한 토양 안정화 평가)

  • Yeo, In-Hong;Chang, Yoon-Young
    • Journal of Environmental Impact Assessment
    • /
    • v.30 no.4
    • /
    • pp.215-224
    • /
    • 2021
  • In this study, to investigate the effect of stabilization of Pb-contaminated soil near a smelter site for the reduction of environmental risk of Pb leaching, commercial stabilizers were amended with the Pb-contaminated soil and evaluated leaching characteristics of Pb in soil by TCLP and SPLP leaching test. Also, performing sequential extraction procedure speciation of Pb in the amended soil was investigated. Limestone, AC-2 (Amron), Metafix (Peroxychem) that possess stabilization performance towards heavy metal in soil and mass production is available were selected as candidates. AC-2 contained a CaCO3 and MgO crystalline phase, while Metafix had a Fe7S8 crystalline phase, according to XRD studies. Pb content in SPLP extract was lower than the South Korean drinking water standard for Pb in groundwater at 4% AC-2 and Metafix treatment soil, and TCLP-based stabilization effectiveness was more than 90%. The findings of the sequential extraction method of soil treated with Metafix revealed that fractions 1 and 2 of Pb, which correspond to relatively high mobility and bioavailable fractions, were lowered, while the residual fraction (fraction 5) was raised. As a consequence, the order of performance for Pb stabilization in polluted soil was Metafix>AC-2>limestone.

Performance Evaluation of Hopper Kinetic Trajectory for Riding Type Automatic Transplanter (승용형 채소 정식기의 식부호퍼 운동 궤적 성능평가시험)

  • Kim, Yeon-Soo;Kim, Yong-Joo;Kim, Jeong-Gil;Kim, Tae-Young;Kim, Young-Joo;Lee, Sang-Dae
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.66-66
    • /
    • 2017
  • 국내 농촌의 인구고령화, 여성화 증가로 인한 농촌노동력 감소 문제를 해결하기 위해 농업기계자동화에 관한 연구가 활발히 진행되고 있다. 본 연구는 자동화농업기계 중 자동 이식기의 성능평가 기술을 개발하기 위해 수행되었으며 이를 위해 자동 정식기의 핵심부품인 이식호퍼의 결주율, 이식율, 주간간격, 운동궤적 등을 측정할 수 있는 원형토조 실험장치를 개발하였다. 원형토조 실험장치는 원형토조, 이식호퍼 구동장치, 컨트롤러로 구성되어 있으며 이식호퍼의 회전속도(rpm)를 조절하여 주간간격을 조절할 수 있고 초고속 카메라를 이용하여 이식호퍼의 운동궤적을 측정할 수 있다. 이식작물로 고추, 양배추, 브로콜리의 3종류의 육묘를 이용하여 이식호퍼의 회전속도를 20~60 rpm 구간에서 10 rpm 단위로 속도조건변화를 주고 결주율과 이식율을 측정하였다. 이식호퍼 rpm 속도에 따른 주간거리는 190~560 mm로 나타났다. 각 rpm 단수, 작물별 평균 이식율은 고추육묘가 약 97%, 양배추육묘가 약 94%, 브로콜리육묘가 약 95%로 나타났다. 또한 초고속 카메라를 이용하여 측정한 이식호퍼의 운동궤적을 통해 선진사 제품과 대비하여 차이를 보인 것을 확인하였다. 향후 원형토조 실험장치를 이용해 다양한 작물 및 토양조건에서의 실험 및 토양저항 측정장치 개발을 통해 이식작업 진행중에 호퍼에 걸리는 부하에 대한 성능평가시험을 할 계획이다.

  • PDF

Comparison of efficiency the grounding resistance enhancement materials used organic.inorganic composite (유.무기 복합재료를 이용한 접지저감제의 성능 비교)

  • Cho, D.H.;Lee, K.S.;Kim, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.66-72
    • /
    • 2004
  • 본 연구는 접지저감제의 성분으로 수용성 고분자의 유기물과 층상형 점토의 무기재료를 주재료하여 새롭게 개발한 새로운 형태의 접지저감제의 성능비교에 관한 것이다. 신개발의 접지저감제는 수분을 흡습하여 수분에 용해된 수용성고분자가 수분과 함께 층상형점토의 층으로 삽입되어 접지저감 성능을 발휘하게 된다. 본 연구의 유 무기 복합재료형 접지저감제는 함수율과 팽창률이 매우 우수할 뿐 아니라 300wt%의 수분을 공급 후 측정한 전기전도도도 매우 뛰어나다. 또한 환경친화적인 천연재료들이므로 인체나 환경에 매우 안전하며, 접지전극의 부식과 전식을 방지하는 기능이 매우 뛰어나 염해나 화학적으로 부식성이 높은 토양에서 큰 장점을 갖는다. 본 논문에서는 신개발의 접지저감제와 기존의 여러 접지저감의 성능을 비교 분석하였다. 이를 위해 현장의 대지저항율을 측정 분석하여 각각의 접지저감제의 접지설계에 적용하여 시뮬레이션하였으며, 시뮬레이션 결과와 현장에서 실제 시공한 측정 결과와 비교 분석하였다.

  • PDF

Development of a high Impedance Fault Detection Method in Distribution Lines using Neural network (신경회로망을 이용한 배전선로 고저항 사고 검출 기법의 개발)

  • 황의천;김남호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.80-87
    • /
    • 1999
  • This paper proposed a high impedance fault detection method using a neural network on distribution lines. The $\upsilon-i$ characteristic curve was obtained by high impedance fault data tested in various soil conditions. High impedance fault was simulated using EMTP. The pattern of High Impedance Fault on high density pebbles was taken as the learning model, and the neural network was evaluated on various soil conditions. The average values after analyzing fault current by FFT of even.odd harmonics and fundamental rms were used for the neural network input. Test results were verified the validity of the proposed method .ethod .

  • PDF

Evaluation of Land Surface Model Ensemble GLDAS for drought monitoring (가뭄감시를 위한 지면모델 앙상블 GLDAS의 활용성 평가)

  • Park, Junehyeong;Kim, Moon-Hyun;Park, Hyang Suk;Kim, Yeon-Hee;Kim, Baek-Jo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.227-227
    • /
    • 2016
  • 일반적으로 가뭄은 신뢰성 높고 활용이 쉬운 강수량 자료를 활용하여 판단되고 있으나, 복합적인 대응을 하기 위해서는 증발산량, 토양수분 등 다양한 변수를 고려해야 한다. 이러한 수문기상정보들은 관측자료의 자료 확보기간이 통계 분석을 하기에 짧거나, 시공간적 대표성 부족 등의 단점이 있다. 이러한 문제점을 극복하기 위해 지면모델이 대안으로 널리 활용중이나, 이를 실제로 가뭄에 활용한 응용연구는 상대적으로 부족한 실정이다. 본 연구에서는 미국 NASA의 전지구지표자료동화체계 GLDAS (Global Land Data Assimilation System) 산출물을 활용하여 지면모델 기반의 수문기상정보를 국내 가뭄감시 연구에 적용하고자 하였다. 이를 위해, GLDAS 프로젝트를 통해 제공되는 다중모델 기반의 증발산량, 토양수분 결과를 비교 분석하고 이를 직접 활용할 수 있는 가뭄판단 지수에 적용하여 성능을 검토하였다. 이를 통해 GLDAS 산출 정보가 가뭄판단에 있어 발휘하는 성능을 평가함으로써, 향후 본원에서 구축할 지면 모델 앙상블 시스템의 가뭄감시정보 산출의 효과를 간접적으로 검토하고자 한다.

  • PDF

Process Evaluation of Soil Washing Including Surfactant Recovery by Mathematical Simulation (계면활성제 재사용을 포함한 토양 세척 공정의 전산모사 평가)

  • Ahn, Chi-Kyu;Woo, Seung-Han;Park, Jong-Moon
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.1
    • /
    • pp.32-42
    • /
    • 2008
  • A surfactant recovery and reuse process by selective adsorption with activated carbon was proposed to reduce surfactant cost in a soil washing process. Mathematical model simulation was performed for the whole process, which consists of soil washing, soil recovery, and soil re-washing. The optimal range of surfactant dosage was $6{\sim}10$-fold critical micelle concentration in soil. The efficiency of surfactant reuse process was decreased with increasing the dosage of activated carbon. Effectiveness factor for activated carbon significantly altered the efficiency of the reuse process unlike effectiveness factor for soil. Total requirement of surfactant was reduced to 20-30% with the reuse process compared to the conventional soil washing process. The contamination of wastewater after soil washing was reduced with the reuse process. This mathematical model can be used to estimate performance of the whole process of soil washing including surfactant recovery and to obtain optimal ranges of operating conditions without extra labor-intensive experimental works.

Calculation Method of Transient Potential Rises of Horizontal Ground Electrodes Depending on Injection Point of the Ground Current (접지전류의 입사점에 따른 정보통신설비용 수평접지전극의 과도전위상승 계산 방법)

  • Ahn, Chang-Hwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.197-203
    • /
    • 2014
  • When the lightning current is injected to the ground system of information and communication facilities, analysis of the transient potential rise in the ground system is one of main factors to effectively design the ground system. The performance of grounding systems is normally estimated with the grounding impedance and the transient potential rise which represents the electrical characteristics of the grounding system. The method for calculating the grounding impedance depending on the injection point of the lightning current was proposed. The delta-gap source model was proposed to calculate the grounding impedance in the case that the lightning current is injected to the center of the horizontal ground electrode. A new program which is possible to apply the frequency-dependent soil parameters using the Debye model was developed, because a commercial program for analyzing the performance of the grounding system can not apply to the frequency-dependent soil parameters. The experiment was carried out to confirm the availability of the simulation results with the same condition. Finally, the transient potential rises of a horizontal ground electrode depending on the lightning current waveforms were analyzed by using the results of the grounding impedance which is associated with the frequency-dependent soil parameters.

Frequency-Dependent Resistivity and Relative Dielectric Constant of Soil on Water Content (수분함유량에 따른 토양의 저항률 및 비유전율의 주파수의존성)

  • Choi, Jong-Hyuk;Cha, Eung-Suk;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.98-104
    • /
    • 2010
  • In order to evaluate the performance of a grounding system against lightning or fault currents including high frequency components, the grounding impedance should be considered rather than the steady state ground resistance. To evaluate the ground impedance, the frequency dependence of resistivity and relative dielectric constant of the soil have to be analyzed. This paper deals with the frequency dependence of the resistivity and relative dielectric constant of three types of soil on water content. As a result, the resistivity of soil is getting lower with increasing of water content. It is nearly independent of the frequency in the range less than 1[MHz], and is decreased over the frequency range above 1[MHz]. On the other hand, the relative dielectric constant is rapidly decreased with the frequency in the range less than 1[MHz], but it is nearly independent on the frequency over the range of 1[MHz]. It was found from the experiments that the frequency-dependant resistivity and relative dielectric constant of soil should be considered when designing the grounding systems for protection from lightning or switching surges.

Breakdown Characteristics of Soils Caused by Impulse Currents (임펄스전류에 의한 토양의 절연파괴특성)

  • Lee, Bok-Hee;Lee, Kang-Soo;Kim, Hoe-Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.103-109
    • /
    • 2010
  • In this paper, breakdown characteristics of soil in a coaxial cylindrical electrode system stressed by impulse currents were experimentally investigated. The breakdown voltage and current waveforms for 4 types of soils were measured, and the threshold electric field intensity, the time-lag to breakdown and the voltage-current (V-I) curves were analyzed and discussed. As a result, the breakdown voltage and current waveforms are strongly dependent on the grain size of soil, and the voltage and current waveforms for gravel and sand differ from those for silt and loess. The threshold electric field intensity Ec is increased in the order of gravel, sand, loess and silt. The V-I curves for all test samples show a 'cross-closed loop' of ${\infty}$-shape. Also, the time-lag to breakdown for gravel and sand are longer than those for silt and loess. It is expected that the results presented in this paper will provide useful information on the design of improving transient performance of a grounding electrode system subjected to lightning current considering the soil ionization.

Three-Dimensional Subsurface Resistivity Profile using Electrical Resistance Tomography for Designing Grounding Grid (접지 그리드 설계를 위한 전기 저항 단층촬영법에 기반한 지표의 3차원 저항률 분포 추정)

  • Khambampati, Anil Kumar;Kim, Kyung Youn
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.4
    • /
    • pp.117-128
    • /
    • 2016
  • Installation of earth grounding system is essential to ensure personnel safety and correct operation of electrical equipment. Earth parameters, especially, soil resistivity has to be determined in designing an efficient earth grounding system. The most common applied technique to measure soil resistance is Wenner four-point method. Implementation of this method is expensive, time consuming and cumbersome as large set of measurements with variable electrode spacing are required to obtain a one dimensional resistivity plot. It is advantageous to have a method which is of low cost and provides fast measurements. In this perspective, electrical resistance tomography (ERT) is applied to estimate subsurface resistivity profile. Electrical resistance tomograms characterize the soil resistivity distribution based on the measurements from electrodes placed in the region of interest. The nonlinear ill-posed inverse problem is solved using iterated Gauss-Newton method with Tikhonov regularization. Through extensive numerical simulations, it is found that ERT offers promising performance in estimating the three-dimensional soil resistivity distribution.