• Title/Summary/Keyword: 토릭소프트콘택트렌즈

Search Result 8, Processing Time 0.021 seconds

Correlations between Axial Rotation of Toric Soft Contact Lenses and Corneal Eccentricity according to the Wearing Time and Gaze Directions (착용시간 및 응시방향에 따른 토릭소프트콘택트렌즈의 축 회전과 각막이심률과의 상관관계)

  • Seo, Woo Hyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.35-45
    • /
    • 2016
  • Purpose: The present study was aimed to investigate the effect of corneal eccentricity on the axial rotation when wearing toric soft contact lenses were worn for certain time and changing the gaze directions. Methods: Toric soft contact lenses with double thin zone design applied on 85 of with-the-rule astigmatic eyes. Then, rotational direction and amount of contact lenses were measured after 15 minutes and 6 hours of lens wear. The difference was further compared and analyzed according to corneal eccentricity. Results: The rotation of toric lens showed a tendency to rotate to temporal direction in all gaze directions except temporal-upper direction in all groups of corneal eccentricity. The amount of lens rotation in the frontal gaze direction exhibited a negative correlation since the amount was decreased with increasing corneal eccentricity after both 15 minutes and 6 hours of lens wearing. In many cases, the cornea with small eccentricity also showed the lens rotation larger than $10^{\circ}$. The difference in rotational amount after 15 minutes of toric lens wear was small according to the corneal eccentricity however, the change of rotational amount of contact lens according to corneal eccentricity was shown after 6 hours of lens wear. Conclusions: The present study revealed that the amount of axial rotation was largely varied according to the wearer's corneal eccentricity when wearing toric lens and the rotational amount after certain time of lens was also affected by corneal eccentricity. Thus, it is suggested that the selection of toric soft contact lenses based on corneal eccentricity is necessary.

Change in Axial Rotation of Toric Soft Contact Lens according to Tear Volume (눈물양에 따른 토릭 소프트콘택트렌즈의 축 회전양 변화)

  • Seo, Woo Hyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.445-454
    • /
    • 2015
  • Purpose: The present study was aimed to investigate the effect of tear volume on a change of axial rotation according to wearing time of toric soft contact lens and gaze directions. Method: Toric soft contact lenses with double thin zone design applied on 62 eyes. Then, changes in non invasive tear film break-up time and the rotational direction/amount of lens when changing gaze direction were respectively measured after 15 minutes and 6 hours of lens wear. Results: Lens rotation to temporal direction was more found when changing gaze direction after lens wear. However, its rotation was varied according to wearing time and the subjects' tear volume. Furthermore, the frequency of lens rotation to temporal direction was higher in dry eyes compared with normal eyes at nearly all gaze directions after 15 minutes and 6 hour of lens wear. The rotational amount of lens was generally greater in dry eyes after 15 minutes of lens wear. However, its difference between normal eyes and dry eyes was not great after 6 hours of lens wear. Conclusion: The present study revealed that axial rotation of toric soft contact lens was varied according to the wearer's tear volume and lens rotational patterns at the initial, and extending periods of lens wear were different. The change in rotational pattern of toric soft contact lens from these results means the possibility of visual change after extending lens wear, and the identification of its correlation with tear volume suggests the necessity of considering factors for choosing appropriate toric soft contact lens.

Difference in Rotation Pattern of Toric Soft Contact Lenses with Different Axis Stabilization Design (축 안정화 디자인이 상이한 토릭소프트콘택트렌즈의 회전 양상 차이)

  • Park, So Hyun;Kim, Dong Yeon;Choi, Joo Hee;Byun, Hyun Young;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.133-140
    • /
    • 2015
  • Purpose: It was investigated whether two different stabilization designs of toric contact lenses changed the rotational axis and degree of toric lenses according to body posture and gaze direction in the present study. Methods: Toric soft contact lenses with Lo-Torque$^{TM}$ design and ASD design (accelerated stabilized design) were fitted on 52 eyes aged in 20s-30s. Then, rotational degree was measured at the five gaze directions including front gaze and the lying position. Results: When gazing the front and vertical directions in the upright posture, lens was much rotated to nasal side for the Lo-Torque$^{TM}$ design and temporal side for the ASD design. When gazing horizontal direction, both design lenses were rotated against to the gaze direction. Rotation degree was the smallest at superior direction gaze and the largest at nasal gaze. In case of the rotation degree less than $5^{\circ}$, Lo-Torque$^{TM}$ design was more frequent when gazing front and vertical directions, and ASD design was more frequent when gazing horizontal direction. In addition, the lens with Lo-Torque$^{TM}$ design was lesser rotation degree than with ASD design immediately after lying. On the other hand, the lens with ASD design was lesser rotation degree than with Lo-Torque$^{TM}$ design 1 minute later after lying. Conclusions: This study confirmed that axis rotation of the lens induced by gaze direction and posture was different according to axis stabilization design during wearing toric soft contact lens.

Clinical Evaluation of Prism-stabilized Toric Soft Contact Lens Fit (프리즘 안정화 디자인 토릭 소프트 콘택트렌즈 피팅에 대한 임상 평가)

  • Kim, Soo-Hyun;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.137-144
    • /
    • 2010
  • Purpose: This study was to evaluate the clinical performance of 1-Day disposable toric soft contact lenses (TSCL) and to compare the visual performance with glasses and TSCL. Methods: In a two-week investigation of 'prism ballast' designed TSCL, occular refractions in 15 (30 eyes) healthy subjects were within the range of -2.75 D TO -8.00 D spherical power and -0.75 DC to -2.25 DC cylinderical power (with-the-rule). Subjects were assessed the clinical performance (orientation, centration, movement, tightness, rotation recovery, symptoms) of TSCL and compared binocular vision and contrast sensitivity with corrected glasses and TSCL at initial and two-week follow-up visits. Results: The prism-ballast design TSCL achieved better orientation, rotation recovery and symptoms over 2 week period. There was no statistically significant difference between spectacles and TSCL with respect to measuring binocular vision and contrast sensitivity. Conclusions: The clinical performance was good with prism-ballast design toric soft contact lenses. Evaluation of binocular vision and contrast sensitivity did not show the differences between spectacles and TSCL correction. This study suggests that TSCL wearers can be achieved similar visual performance for spectacles wearers.

Contrast Sensitivity and Glare with Spherical and Toric Soft Contact Lenses in Low-astigmatic Eyes (구면과 토릭 소프트 렌즈로 교정한 약도 난시안의 대비감도와 눈부심)

  • Lee, Min-Ah;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.39-45
    • /
    • 2009
  • Purpose: The purpose of this study is to compare the visual performance by contrast sensitivity (CS) and disability glare (DG) in low astigmatic eyes corrected with toric soft lenses and other optical corrections. Methods: Twenty university students with myopia (-1.00 to -6.50D Sph. with astigmatism up to 1.50 cyl) were enrolled and corrected by five different methods: 1) soft toric lenses; 2) spherical soft contact lenses; 3) RGP lenses; 4) best spectacle corrected visual acuity; 5) spherical equivalent spectacles. All subjects had corrected vision acuity of 20/20 or better. Contrast sensitivity and disability glare were measured using the OPTEC 6500 contrast sensitivity view-in tester included the EyeView Functional Vision Analysis software at photopic or mesopic conditions with glare. Results: At photopic condition, best corrected spectacle wearers had the highest monocular contrast sensitivity at all spatial frequency followed by soft toric lenses, RGP lenses, spherical equivalent spectacles, and spherical soft contact lenses. However, all of them were in normal contrast sensitivity value at photopic condition. At mesopic condition with glare, toric soft lenses were the highest and followed by RGP lenses, spherical equivalent spectacles, best spectacle corrected visual acuity and spherical soft contact lenses. It was observed that spherical soft contact lens wearers demonstrated lower range than normal contrast sensitivity value at mesopic condition with glare. Conclusion: Toric soft lenses gave better visual performance than spherical soft lenses in low astigmatic eyes. Subjects requiring the use of contact lenses under mesophic conditions could benefit from toric soft lenses.

  • PDF

Analysis of Axial Mis-alignment After Wearing of Toric Soft Contact Lenses (토릭소프트콘택트렌즈의 착용 후 축 정렬 상태의 변화 분석)

  • Kim, Sang-Yoeb;Lee, Dong Yeol;Lee, Sun-Haeng;Kim, Kun-Kyu;Song, Sop;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.213-217
    • /
    • 2010
  • Purpose: To emphasize the necessity of post-fitting by follow-up test, the mis-alignment was analyzed after initial wearing of toric soft contact lenses (TSCL). Methods: After trial contact lenses were worn to 87 eyes with myopic astigmatism for 1 week, we observed the alignment of axis mark on trial contact lenses using slit lamp and corrected the rotated axis by method of LARS. After final fitting, rotation ratio, rotation degree and rotation position were analyzed compared to initial prescription divided to amount of cylinderical and spherical powers. Results: Rotation ratio of TSCL's axis was increased as increment of both cylinderical powers and (-)spherical powers. An average of rotation degree was $10^{\circ}{\sim}13^{\circ}$ which was not related to amount of their powers. Rotation position of TSCL's axis was more to temporal than to nasal. Conclusions: Because mis-alignment of axis after TSCL wearing induce the poor sight, adjustment of axial alignment as a result of follow-up must be performed.

Contact lens Prescription and Satisfaction with Astigmatism Eye (난시안의 콘택트렌즈 처방과 만족도에 관한 연구)

  • Kim, Mi-Yeon;Kim, Yeong-Mi;Kim, Tae-Hun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.4
    • /
    • pp.317-322
    • /
    • 2006
  • For this study we made up a question investigation to analyze a grade of satisfaction and a side effect about the prescription actual condition of contact lens of person with astigmatism among the person who has a error of refraction. The whole patient of refractive error was 46 person, there were 11 person who only wear spectacles by correction of visual acuity among person to a question investigation and 35 person who only wear contact lens. Under investigation 35 person who only wear contact lens, there were 25 person who experience the problem which occurs because of contact lens wearing for a long time. The most patient who made up a question investigation very choose remainder item except for item of very satisfaction. The their reason that could not satisfaction was non corrected astigmatism, wrong prescription, wrong Base curve, out of life span etc.

  • PDF

Contact Lens Prescribing Pattern in Korean During 2010 to 2013 (대한민국의 최근 4년간(2010-2013) 콘택트렌즈 처방 추세)

  • Lee, Jong-Ha;Lee, Ki-Seok;Chu, Byoung-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.323-329
    • /
    • 2014
  • Purpose: To understand the pattern of prescribing contact lenses in Korea from 2010 to 2013. Methods: Four hundred survey questionnaires were randomly posted to Korean Optometric clinics for 4 years. The questionnaire was the same form as a form used for International Contact Lens Prescribing Trend. It was also designed to collect information about the contact lenses prescribed to the first 10 patients after its receipt. Results: 1937 fits were used for the analysis among the four hundred survey questionnaires. The average patient age was $26.2{\pm}7.0$ in 2010, $26.1{\pm}7.6$ in 2011, $24.7{\pm}6.6$ in 2012 and $24.8{\pm}7.2$ in 2013. The patients were mainly women (75%). Of all the soft contact lenses, silicon hydrogel lenses were 18% of fits (17% in 2010, 10% in 2011, 20% in 2012, 24% in 2013). By degine, the percentage of toric design lenses accounted for 17% of soft lenses fits and had increased during 4 years (10% in 2010, 18% in 2011, 16% in 2012, 22% in 2013), and cosmetic contact lens made up for 29% (15% in 2010, 20% in 2011, 40% in 2012, 41% in 2013). Conclusions: The contact lenses wearers were mostly women and the average patient age becomes slightly younger. In relation to the increase in the mumber of younger female contact lens wearers,the percentage of cosmetic lenses prescription was much higher (29%) than the global average (7%), and it has gradually increased for last 4 years. This trend could be related to the growth of beauty market in Korea. By emphasizing on toric lens marketing in manufactures, the prescription rate has been gradually increased.