• Title/Summary/Keyword: 터빈 부하

Search Result 276, Processing Time 0.026 seconds

Study on the Braking Characteristics of Starting System Used for Initial Spin-up of Gas Turbine (가스터빈 초기 구동용 시동시스템의 제동특성 연구)

  • Song, Ju-Young;Park, Jun-Cheol;Lee, Ki-Hoon;Kim, Sung-Hyun;Nam, Sam-Sik
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.379-382
    • /
    • 2011
  • Engine test as well as unload test of starting motor itself was performed to evaluate the braking characteristics of starting system used for initial spin-up of gas turbine for power generation. Through the experimental evaluation of the braking performance with the capacity of braking resistor of the starting motor, we have achieved quantitative data to secure robust braking characteristics in emergency during the starting period of the gas turbine. It is possible to establish a capacity selection criterion of braking resistor to ensure the starting reliability of the gas turbine.

  • PDF

Characteristics of the Shaped Hole Film Cooling in Gas Turbine (가스터빈에서 변형홀을 사용한 막냉각 특성 해석)

  • 이동호;김병기;조형희
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.7-7
    • /
    • 1998
  • 가스터빈 엔진의 효율 및 성능은 터빈입구온도에 크게 좌우되므로, 높은 열효율을 얻기 위하여 최근 가스터빈 엔진은 높은 입구온도(대략 1400-150$0^{\circ}C$)에서 작동되도록 설계되고 있다. 이는 요소재질의 열한계점을 훨씬 상회하며, 이와 같은 입구온도의 고온화 경향은 터빈요소에 대한 열부하를 증가시키고 있다. 따라서 극한의 작동조건하에서의 허용수명 및 안정성의 유지를 위해서 내부대류냉각, 충돌세트냉각과 더불어 막냉각기법이 많이 응용되고 있다. 막냉각기법은 연소기 벽면 혹은 터빈블레이드 표면의 작은 구멍들을 통해서 압축기의 공기를 분사하여 표면에 고온의 유체와 일종의 단열벽을 형성하여 표면을 보호하는 냉각방법이다. 지금까지는 주로 단면적이 일정한 막냉각홀에 대한 연구가 주가 되어왔으나, 이러한 막냉각홀을 이용하는 경우 많은 문제점이 발생한다.

  • PDF

Application of Automatic Generation Control Logic for a Thermal Power Plant (증기터빈 발전소의 자동 부하 증감발 운전(AGC) 제어로직 구현 및 적용)

  • Woo, Joo-Hee;Km, Jong-An
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2147-2149
    • /
    • 2001
  • 국내 한 증기터빈 발전소의 출력증감발 운전을 중앙급전 명령에 의해 가능하도록 하는 제어로직을 구현하였다. 이는 중앙급전으로부터 증감발 펄스 신호를 입력받아 발전기 출력 설정치를 변경함으로써 이루어지고, 증감되는 양은 펄스의 지속시간에 의해 이루어지며 여러 가지 운전상황에 대해 원활한 운전전환이 이루어져야 한다. 본 논문에서는 이를 구현하기 위해 제어로직 및 운전원 조작 화면의 구성을 소개하고자 한다.

  • PDF

Analysis of Start-up System for 200MVA Gas-Turbine Synchronous Generator (200MVA급 가스터빈용 동기발전기의 기동시스템 해석)

  • An, Hyunsung;Lee, Wook-Jin;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.204-205
    • /
    • 2017
  • 본 논문은 복합화력 발전소의 가스터빈용 기동 시스템의 개발을 위해 국내 복합화력 발전소의 동기발전기 파라미터를 적용하여 모델링하였으며, 200MVA급 동기발전기의 기동 시스템 운전 방법을 해석하였다. 200MVA급 동기발전기를 기동하기 위해 10MW의 6-펄스 부하 전류형 인버터와 속도 및 전류 제어기 등을 설계하였으며, 실제 국내 기동 시스템의 운전 특성과 비교하여 모델링을 검증하였다.

  • PDF

Development of Automatic Ultrasonic Testing Techniques of Low Pressure Turbine Blade of Nuclear Power Plants (원자력 발전소 저압 터빈 동익 자동 초음파 검사 기술 개발)

  • Yang, Seung-Han;Lee, Jeong-Bin;Kim, Young-Ho;Yoon, Byung-Sik;Kim, Yong-Sik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.371-377
    • /
    • 2004
  • As the turbine running duration in nuclear power plants increases, cracks have been found in the pin finger type blade root area. The nondestructive examination for the blade root area has been carried out by manual ultrasonic examination during the overhaul period, but because of necessity to improve the reliability, we developed an automatic ultrasonic examination system and technique. To demonstrate the performance of the developed automatic ultrasonic examination system, low pressure turbine blades in the 2nd and 3rd stages of nuclear power plants were examined using the developed system. Its applicability nuclear power plant turbine roots of various types was also confirmed.

A Study on the Response Characteristics of 200MW Gas Turbine Governor System (200MW급 가스터빈 조속기 응답특성에 대한 연구)

  • Han, Young-Bok;Nam, Kang-Hyun;Kim, Sung-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.4
    • /
    • pp.625-632
    • /
    • 2022
  • Gas turbine generators in load-following operation in the domestic power system play a major role in maintaining the rated frequency, but often have poor frequency control. Therefore, after examining the control characteristics of the governor, which is a gas turbine speed control device, and analyzing the failure types, countermeasures were suggested for each case. In addition, it was confirmed through the governor response test that the gas turbine helps in frequency recovery depending on the speed of fuel control, but also acts as a factor impeding stable operation, such as rapid fluctuations in combustion chamber temperature and combustion vibration. Therefore, in order to maintain stable power quality, there was a need for thorough facility management as well as research on the governor control method in which the traditional PID control method and the machine learning algorithm, a core field of the 4th industry, were fused.

Thermal Stress Analysis for Life Assessment of Small Steam Turbine Rotor (소형 기력발전용 터빈로터의 수명평가를 위한 열응력 해석)

  • 이진상;백운봉;윤기봉
    • Journal of Energy Engineering
    • /
    • v.9 no.3
    • /
    • pp.184-191
    • /
    • 2000
  • 본 연구에서는 국내 10MW급 기력발전소의 소형 터빈 로터에 대한 응력 해석을 실시하였다. 터빈 로터의 기하학적 형상, 증기의 온도 및 압력 등의 기동조건 변화, 로터 재료의 온도에 따른 물성값 등을 고려하여 대류 열 전달계수를 계산하는 사용자 부프로그램을 구성하였으며, 이를 바탕으로 열해석을 실시하여 로터의 온도 분포를 결정하였다. 이 온도분포 조건에서 시간 경과에 따른 열응력 해석을 실시하여 로터의 응력 분포를 결정하였으며 그 결과 취약부위에서의 응력변동 범위 및 가동중 정상상태 응력수준을 결정하였다. 이 취약부위의 응력값과 운전이력을 이용하여 크리프 수명과 피로수명을 계산하고 로터의 잔여수명을 결정하는 방법을 논의하였다.

  • PDF

Wind Tunnel Test Results for 12% Wind Turbine Model(NREL Phase VI) (12% 축소형 풍력터빈 풍동시험 결과 NREL Phase VI 모델)

  • Cho, Tae-Hwan;Kim, Yang-Won;Chang, Byeong-Hee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.245-248
    • /
    • 2006
  • 풍력터빈 풍동시험의 경우 모델 축소에 의한 레이놀즈 수 감소가 ?V력터빈 성능에 미치는 영향이 적절히 고려되어야 한다. 본 연구를 통해 수치해석과 축소모델 풍동시험을 통해 모델 축소효과를 파악하여 이를 적절히 보상하는 기법을 개발하고자 한다. 이를 위해 풍력터빈 형상 및 실물모델 시험데이터가 공개되어 있는 NREL Phase VI 모델을 표준모델로 선정하여 수치해석 및 풍동시험을 수행하였다. 풍동시험은 KARI LSWT에서 2006. 10에 수행되었으며, 블레이드 끝단 속도를 실물 모델과 일치시켰으며 시험부 유속은 $0{\sim}25m/s$, 블레이드 설치각은 3도 조건을 기준조건으로 사용하였다. 축소모델 시험결과 최대토크는 약 10% 정도 감소현상을 보이고 있다.

  • PDF