• Title/Summary/Keyword: 태양 일사

Search Result 464, Processing Time 0.029 seconds

Modeling Analysis for Thermal Performance of Solar Flat Plate Collector System Through a Year (평판형 태양열 집열기의 연중 열적 성능의 모델링 해석)

  • Kim, Gew Deok;Park, Bae Duck;Kim, Kyoung Hoon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.5
    • /
    • pp.541-549
    • /
    • 2014
  • The monthly-average meteorological data, in particular, the monthly average daily terrestrial horizontal insolation are required for designing solar thermal energy systems. In this paper, the dynamic thermal performance of a flat plate solar collector system is numerically investigated through a year from the monthly average insolation data in Seoul. For a specified data set of solar collector system, the dynamic behaviors of total solar radiation on the tilted collector surfaces, heat loss from the collector system, useful energy and collector efficiency are analyzed from January to December by a mathematical simulation model. In addition, the monthly average daily total solar radiation, useful energy, and daily collector efficiencies through a year are estimated. The simulated results show that the average total radiation is highest in March and the useful energy is highest in October, while the total radiation and the collector efficiency are lowest in July.

Study of the solar radiation and economic evaluation for the expected site of solar power plant on the waterworks site (수도사업장 태양광개발 예정지에 대한 일사량 및 경제성 평가에 관한 연구)

  • Choi, Hyeong-Cheol;Lee, Nam-Hyeong;Chang, Jeong-Ho;Na, Hye-Ran
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.139-142
    • /
    • 2009
  • The worldwide energy market is enlarging rapidly according to current issues like globalization, deregulation, global warming and strengthening for environmental regulation as well as the energy technology is developing speedily by the add of information and communication techniques. In spite of these advanced techniques in the field of the renewable energy, solar power depends on the governmental aid largely in comparison with other renewable energy sources because of the high initial investment cost. Therefore it is important to investigate scrupulously for the expected erection site of solar power plant from the planning stage. This paper shows actual measurement data of solar radiation of scheduled solar power locations in the waterworks site with consideration of waterworks facilities and regional specialties and presents the data which was analyzed comparably with the radiation data of adjacent locations served by national authorities. In addition, these data were analyzed using RETScreen and used for making decision on the business validity.

  • PDF

The Characteristics of PV module under the Partial Shading Condition and with a Failure of Bypass Diode with Short (PV모듈의 음영 상태 및 바이패스 다이오드 단락 고장 특성 분석)

  • Ko, Suk-Whan;Ju, Young-Chul;So, Jung-Hun;Hwang, Hye-Mi;Jung, Young-Seok;Kang, Gi-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.4
    • /
    • pp.41-47
    • /
    • 2016
  • A bypass diode is connected in parallel to solar cells with opposite polarity. The advantage of using the bypass diode is circumvented a destructive efforts of hot-spot heating in the photovoltaic(PV) module. In addition, it is possible to reduce a energy loss under the partial shading on the PV module. This paper presents a characteristic of photovoltaic module under partial shading condition and with defective bypass diode by using the experimental data. The results of field testing for each photovoltaic modules, when photovoltaic system which is connected power grid is operating, the inner junction-box temperature of shading photovoltaic module is high $5^{\circ}C$ because of difference of flowing current through into bypass diode. And incase of not operating photovoltaic system, the inner junction-box temperature of module with defective bypass diode is greatly higher than partial shading PV module.

Analysis of Solar Radiation Components in Korea (국내 일사량의 성분 분석)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heack
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.8-12
    • /
    • 2009
  • The Knowledge of the solar radiation components are essential for modeling many solar energy systems. This is particularly the case for applications that concentrate the incident energy to attain high thermodynamic efficiency achievable only at the higher temperatures. In order to estimate the performance of concentrating thermal systems, it is necessary to know the intensity of the beam radiation, as only this component can be concentrated. The Korea Institute of Energy Research(KIER) has began collecting solar radiation component data since August, 2002. KIER's component data will be extensively used by concentrating system users or designers as well as by research institutes. The Result of analysis shows that the annual-average daily diffuse radiation on the horizontal surface is $1,458cal/m^2$ and daily direct radiation on the horizontal surface is $1,632cal/m^2$ for all over the 16 areas in Korea.

  • PDF

The Evaluation of the Temperature Characteristics at the Spendrels of Curtain wall with a-Si BIPV Window System (스팬드럴 부분 BIPV창호 적용 및 후면마감재 구성에 따른 온도특성 분석 연구)

  • Kim, Dong-Su;Oh, Myung-Hwan;Yoon, Jongl-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.165-170
    • /
    • 2012
  • This study aims to analyze the characteristics of temperature variation of Spandrels. According to the change of SHGC of Window system, air space, insulation performance and absorption factor of inner surface at the Spandrels, It was firstly estimated by using simulation. Secondly, measured to minimize the temperature-rise of inner surface temperature and the intermediate air temperature by using Full-scale Mock-up based on the result of simulation analysis. As a result, it turns out that low SHGC window system such as BIPV system had an advantage of reducing the window surface temperature, and the surface temperature of clear window system was all higher than BIPV system on simulation results. In the experiment results, it had some advantages of increasing the Spandrels volume, decreasing insulation performance and lower absorption factor.

  • PDF

Solar Radiation Estimation Technique Using Cloud Cover in Korea (운량에 의한 일사예측 기법)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heack
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.232-235
    • /
    • 2011
  • Radiation data are the best source of information for estimating average incident radiation. Lacking this or data from nearby locations of similar climate, it is possible to use empirical relationships to estimate radiation from days of cloudiness. It is necessary to estimate the regression coefficients in order to predict the daily global radiation on a horizontal surface. There fore many different equations have proposed to evaluate them for certain areas. In this work a new correlation has been made to predict the solar radiation for 16 different areas over Korea by estimating the regression coefficients taking into account cloud cover. Particularly, the straight line regression model proposed shows reliable results for estimating the global radiation on a horizontal surface with monthly average deviation of-0.26 to +0.53% and each station annual average deviation of -1.61 to +1.7% from measured values.

  • PDF

Evaluating Explanatory Power of Solar Intensity as Determining Factor of Housing Density in Intermontane Basin (산간분지에서 주택밀도의 결정인자로서 태양광도의 영향력 평가)

  • Um, Jung-Sup
    • Journal of the Korean association of regional geographers
    • /
    • v.15 no.6
    • /
    • pp.689-706
    • /
    • 2009
  • It is usual to prioritize the spatial variables that influence housing location by a few specialist's experienced knowledge or intuition. Multiple regression techniques were used to evaluate the spatially prioritized relationships between housing density and seasonal solar intensity parameters for a total of 134 house locations. Solar radiation and duration of sunshine on winter solstice was the most important predictor of house density located in intermontane basin. In contrast to the typical theory, elevation, slope and accessibility to road were not a dominant determining factor upon the dependent variable of house density. A clear verification has been made for the hidden assumptions for the arrangement of typical Korean housing in intermontane basin that its approach is found to be more appropriate in avoiding shadow conditions, rather than exploring the ideal landform location.

  • PDF

An Experimental Study on the Condensation Characteristics of Sea Water in the Tilted Box with Solar Radiation (태양열을 받는 경사진 육면체 내 해수의 응축특성에 관한 실험적 연구)

  • Kim, Beom-Han;Kim, Byung-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.27-33
    • /
    • 2011
  • To find effective way of the production of distilled water for drought and flood with solar radiation, three boxes were made same base each 1000mm ${\times} $1000mm and tops are 45 degree. Individual boxes contained the sea water, rain water and surface water were placed at the same location and same time. Condensation of each box has been compared. On clear day production of distilled water in the box with sea water was 36% and 32% less than boxes with rain water and surface water. The maximum condensation reached when the temperature of the top and bottom parts are equal. As concentration of sea water increased production of distilled water was decreased. In the box with sea water, the surface temperature was lower than 3cm below the surface. Optimum collector area for producing distilled water 2000ml of these three boxes were $3.75m^2$

A Study on Computer Simulation to Investigate Correlations between Temperature Controlling Effect of Green Roof System and the Photovoltaic Power Generation Efficiency (옥상녹화시스템의 기온조절효과와 태양광발전효율간의 상호연관성 규명을 위한 전산해석연구)

  • Kim, Tae Han;Park, Sung Eun
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.4
    • /
    • pp.70-79
    • /
    • 2013
  • These day cities experience serious climatic changes due to environmental load caused by disturbance in the circulation systems of water resources and energy. As technological improvement to respond to various climatic changes and disasters are also requested in the field of construction, inter-disciplinary studies linked to the establishment of sustainable environmental control and energy systems is required in a consilient perspective. This study aims to infer correlations in the impact of environmental changes caused by rooftop greening system on the photovoltaic power generation efficiency through computer simulation in an integrated perspective. By doing so, it seeks to provide basic study for developing a photovoltaic system integrated with building revegetation that is sustainable in environmental and resource aspects. A simulation showed that, in the case of sunshine hours in June, the green surface indicated temperature lowering effects of $9.19^{\circ}C$ on average compared to the non-green surface and temperature was $9.81^{\circ}C$ lower. Due to such greening effects, at the highest sunlight timepoint in June, Pmpp improved 119W and heat loss rate dropped 7.8%.

Intercomparison of Shortwave Radiative Transfer Models for Aerosol-laden Atmospheres (에어러솔 대기에서 단파 영역에서의 복사전달모델들의 상호비교)

  • Yoo, Jung-Moon;Jeong, Myeong-Jae;Lee, Kyu-Tae;Kim, Jhoon;Rhee, Ju-Eun;Hur, Young-Min;Kim, Bo-Mi;Lee, Yun-Gon;Lee, Jae-Hwa;Yoon, Jong-Min;Lee, Won-Hak
    • Journal of the Korean earth science society
    • /
    • v.29 no.2
    • /
    • pp.128-139
    • /
    • 2008
  • Intercomparison among the three radiative transfer models (RTMs) which have been used in the studies for COMS, was carried out on the condition of aerosol-laden atmospheres. Also the role of aerosols in the atmospheric radiation budget was analyzed. The results (hereafter referred to as H15) from Halthore et al.'s study (2005) were used as a benchmark to examine the models. Aerosol Radiative Forcing (ARF) values from the three RTMs, calculated under two conditions of Aerosol Optical Thickness (AOT=0.08, 0.24), were systematically underestimated in comparison to H15 in the following shortwave components; 1) direct and diffuse irradiance at the surface, 2) diffuse upward fluxes at the surface and the top of the atmosphere, and 3) atmospheric absorbance. The ARF values for the direct and diffuse fluxes at the surface was $-10{\sim}-40Wm^{-2}$. The diffuse upward values became larger with increasing both AOT and Solar Zenith Angle (SZA). Diffuse upward/downward fluxes at the surface were more sensitive to the SZA than to the atmospheric type. The diffuse downward values increased with increasing AOT and decreasing SZA. The larger AOT led to surface cooling by exceeding the reduction of direct irradiance over the enhancement of diffuse one at the surface. The extinction of direct solar irradiance was due mainly to water vapor in tropical atmospheres, and to both ozone and water vapor in subarctic atmospheres. The effect of water vapor in the tropics was $3{\sim}4$ times larger than that of the ozone. The absorbance values from the three RTMs agree with those from H15 within ${\pm}10%$.