• Title/Summary/Keyword: 타워 구조물

Search Result 64, Processing Time 0.028 seconds

Trends of Research and Practical Use on Explosive Spalling Properties and Performance Based of Structural Design of the High-Strength Concrete (고강도콘크리트의 폭렬대책공법에 대한 국내외 현황과 성능적 구조내화설계를 위한 과제)

  • Kwon, Young-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.935-940
    • /
    • 2008
  • When reinforced concrete is subjected to high temperature as in fire, there is deterioration in its properties of particular importance are loss in compressive strength, cracking and spalling of concrete, destruction of the bond between the cement paste and the aggregates and the gradual deterioration of the hardend cement paste. Assessment of fire-damaged concrete usually starts with visual observation of color change, cracking and spalling of the surface. In this paper, it was reported the trends of research and practical use on the Explosive Spalling Properties and Performance Based of Structural Design of the High-Strength Concrete.

  • PDF

Visualization Study of Wave Generation in Short-Distance Wave Maker (소형 조파기 내의 조파생성에 대한 가시화연구)

  • Jung, Eui-Chul;Yuan, Zhen-Zhong;Lim, Hee-Chang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.3
    • /
    • pp.293-300
    • /
    • 2013
  • This study used a water tank and wave maker to generate conditions similar to the real ocean environment. Given that the waves were properly generated in the water tank, a precise analysis indicated the quantitative value of the wave force acting on a body. A high-speed camera and wave-level gauge were used to measure the temporal wave motion and period. A series of artificial water waves were successfully generated using three different wave periods and amplitudes. Each of the waves captured by a high-speed camera was sinusoidal and did not maintain its shape properly without a wave absorber, but it was substantially improved and well shaped when the wave absorber was installed.

Optimal Sensor Placement for Structural Parameter Estimation Using Genetic Algorithm (유전자 알고리즘을 이용한 구조계수추정 목적의 최적 계측점 선정)

  • Bahng, Eun-Young
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.4
    • /
    • pp.9-16
    • /
    • 2010
  • In the health monitoring of civil engineering structures, the optimal sensor placement has a major influence on the quality of the results. This paper considers the problem of locating sensors with the aim of maximizing the data information so that structural parameters or damage of structures can be assessed. An proposed technique using a genetic algorithm is introduced to find the optimal placement of sensors. The sensitivity on modal vectors by structural parameters and the orthogonality of modal vectors have been taken as the fitness function of the genetic algorithm. A simple tower structure is used for example analyses to investigate the feasibility and applicability of the proposed approach. The example analyses show the way how the modal sensitivity and the modal orthogonality in the fitness function have influence on the optimal sensor placement. It is shown that the present method using the proposed fitness function can provide the reliable results.

Determination of optimum protection potential for cathodic protection of offshore wind-turbine-tower steel substructure by using potentiostatic method (정전위법에 의한 해상풍력 타워 구조물용 강재의 음극방식을 위한 최적방식전위 결정)

  • Lee, Jung-Hyung;Jung, Kwang-hu;Park, Jae-Cheul;Kim, Seong-Jong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.230-237
    • /
    • 2017
  • In this study, electrochemical methods were used to determine the optimum protection potential of S355ML steel for the cathodic protection of offshore wind-turbine-tower substructures. The results of potentiodynamic polarization experiments indicated that the anodic polarization curve did not represent a passivation behavior, while under the cathodic polarization concentration, polarization was observed due to the reduction of dissolved oxygen, followed by activation polarization by hydrogen evolution as the potential shifted towards the active direction. The concentration polarization region was found to be located between approximately -0.72 V and -1.0 V, and this potential range is considered to be the potential range for cathodic protection using the impressed current cathodic protection method. The results of the potentiostatic experiments at various potentials revealed that varying current density tended to become stable with time. Surface characterization after the potentiostatic experiment for 1200 s, by using a scanning electron microscope and a 3D analysis microscope confirmed that corrosion damage occurred as a result of anodic dissolution under an anodic polarization potential range of 0 to -0.50 V, which corresponds to anodic polarization. Under potentials corresponding to cathodic polarization, however, a relatively intact surface was observed with the formation of calcareous deposits. As a result, the potential range between -0.8 V and -1.0 V, which corresponds to the concentration polarization region, was determined to be the optimum potential region for impressed current cathodic protection of S355ML steel.

Evaluation of the Shaft Resistance of Drilled-in Steel Tubular Pile in Rock Depending on the Proportion of Annulus Grouting Material (주면고정액 배합비에 따른 암반매입 강관말뚝의 주면지지력 평가)

  • Moon, Kyoungtae;Park, Sangyeol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.1
    • /
    • pp.51-61
    • /
    • 2018
  • Foundation of tower structures such as wind turbine, pylon, and chimney have to resist considerably large overturning moment due to long distance from foundations to load point and large horizontal load. Pile foundations subjected to uplift force are needed to economically support such structure even in the case of rock layer. Therefore, this research performed the laboratory model tests with the variables, W/C ratio and sand proportion, to evaluate the effect of the mix proportion of grouting material on shaft resistance. In the case of cement paste, maximum and residual shaft resistance were distributed in uniform range irrespective of the changes of W/C ratio. However in the case of mortar, they were decreased with increasing W/C ratio, while they were increased and then decreased with increasing sand proportion. In the case of no sand, the maximum shaft resistance was about 540~560kPa regardless of the W/C ratio. When the sand proportion was 40%, it was about 770~870kPa depending on W/C ratio, which was about 40~50% higher than that without sand. The optimum proportion found in this research was around 40% of sand proportion and 80~100% of W/C ratio.

Model Test on Motion Responses and Anchor Reaction Forces of an Articulated Tower-Type Buoy Structure in Waves (아티큘레이티드 타워 형태의 부이 구조물에 관한 파랑 중 운동응답 및 앵커 지지력에 관한 모형시험 연구)

  • Kwon, Yong-Ju;Nam, Bo Woo;Kim, Nam Woo;Won, Young-Uk;Park, In-Bo;Kim, Sea-Moon
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.3
    • /
    • pp.214-221
    • /
    • 2019
  • A series of model tests was performed to evaluate the survivability of an articulated tower-type buoy structure under harsh environmental conditions. The buoy structure consisted of three long pipes, a buoyancy module, and top equipment. The scale model was made of acrylic pipe and plastic with a scale ratio of 1/22. The experiments were carried out at the ocean engineering basin of KRISO. The performance of the buoy structure was investigated under waves only and under combined environmental conditions from sea state (SS) 5 to 7. A nonlinear time-domain numerical simulation was conducted using the mooring analysis program OrcaFlex. The survivability of the buoy was analyzed based on three factors: the pitch motion, submergence of the top structure, and anchor reaction force. The model test results were directly compared to the results of numerical simulations. The effects of the sea state and combined environment on the performance of the buoy structure were investigated.

Experimental Study on Bond Behavior of 1/12.5 Scale Model of the Steel Tubular Joint Connection Subjected to Compressive Loads (압축하중을 받는 1/12.5 축소모형 강관 연결부의 부착전단 거동에 대한 실험적 연구)

  • Hongseob Oh
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.3
    • /
    • pp.19-26
    • /
    • 2024
  • In this study, the compressive behavior of a 1/12.5 scale model of a wind tower support structure connection was experimentally analyzed. A high-performance cementitious grout with a compressive strength of 140 MPa was used to fill the connection, and experiments were conducted with shear key spacing, the shape, and connection length as variables. When the number of shear keys in the connection is the same, the smaller the spacing of the shear keys than the length of the connection, the higher the shear strength, and for the same spacing and connection length, the higher the height of the shear keys, the higher the strength. In addition, it was found that the strength showed a linear behaviour until the connection slip reached 1.0 mm, and it reached the maximum strength at 7.0 mm connection slip showing a non-linear behaviour as the load increased. It was found that the failure mode changed from interfacial shear failure to grout failure as the strength increased according to the shape and spacing of the shear key, and brittle failure did not occur due to steel fibers.

Experiments for the Vibration Control of Steel Frame Structure Using Toggle Brace and Lead Rubber Damper (토글가새와 납-고무 제진장치를 적용한 구조물 진동제어 실험)

  • Park, Jung-Woo;Park, Jin-Young;Lee, Wan-Ha;Kim, Ki-Man;Park, Kun-Nok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.171-176
    • /
    • 2011
  • The purposes of the research were to evaluate system performance and response of building structure under external load for full scale modal-testing-tower applied toggle bracing and lead rubber damper(LRD). The dynamic properties of the structure were measured before and after installing damper under harmonic excitation using the AMD and the results were compared. The harmonic excitation condition is to increase 0.01Hz sine sweep signal from 0.49Hz to 0.63Hz. As a result of measuring resonant frequency, before installing damper is 0.55Hz and after installing damper is 0.62Hz. The experimental results after installing damper were also distinguished from simulation results and the main cause of this results is temperature dependency property of rubber material.

  • PDF

The Application of Post-tensioned Slab System to Tall Buildings (초고층 건축물의 포스트텐션 슬래브 시스템 적용)

  • Chung, Kwang-Ryang
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.879-882
    • /
    • 2008
  • The market of Korea of post-tension system for building is growing up since 2000 and many engineers and construction companies show interest in it. This paper introduces the structure system and construction of post-tension tall buildings including recent trend in the industry of post-tension system for buildings in Korea and the point to be considered when design post-tensioned tall building. Park Polis is composed of two towers of 39 stories with a level to the top of the roof +144m and is currently under construction at Ulsan in Korea. This building designed as the unbonded post-tension floor system and will be the tallest and first high-rise post-tensioned building in Korea. The structural system is composed of the flat slabs, perimeter columns and core walls. At first, this building had designed as regular RC flat slab with perimeter beams. However, floor structure system was reconsidered because the construction company wants to improve efficiency of construction. As a result, the floor system of PARK POLIS re-designed as PT flat slab.

  • PDF

An Structural Design for Cyclone Tower's Connections Using Diagrid System (다이아그리드 구조시스템의 접합부개발과 성능평가)

  • Lee, Se-Jung;Lee, Seong-Hui;Kim, Jin-Ho;Choi, Sung-Mo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.2
    • /
    • pp.105-115
    • /
    • 2010
  • Recently, High-rise building are irregular-shaped to be city landmarks and function as vertical cities to enable the efficient use of land. 3T (Twisted, Tilted & Tapered) designs are being suggested for irregular buildings and studies to develop new structural system have been actively made to satisfy slender shape ratio. In diagrid system, not only gravity load but also lateral load is delivered based on the triangular shape of diagrid, so most of columns are eliminated. Because shearing force is delivered by the axial behavior (tensile/compressive) of diagrid to minimize shearing deformation, the system is more applicable to irregular buildings than existing system where shearing force is delivered by the columns. In this study, the process of selecting connection details and the structural safety of the selected details are verified using the finite element analysis with focus given to the construction overview of the Cyclone Tower. However, the relersed methods of stress concentration are suggested and the performance of stress concentration relieves that it's suggested for the appropriate cap plate thickness and extended length.

  • PDF