• Title/Summary/Keyword: 타설 온도

Search Result 135, Processing Time 0.023 seconds

Development Ultra Rapid Hardening Construction Materials on Cold Weather Environment Considering Curing Temperature (양생온도를 고려한 극한지용 초속경 건설재료 개발)

  • Cho, Hyun-Woo;Shin, Hyun-Seop;Lee, Jang-Hwa
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.59-66
    • /
    • 2013
  • Because ordinary concrete cannot be hardened well under sub-zero temperatures, anti-freeze agents are typically added to prevent the frost damage and to ensure the proper hardening of concrete. With the advantage of a rapid exothermic reaction property, jet set concrete may be used as a cold weather concrete because it can reach the required strength before being damaged by cold weather. Recent studies are reported that magnesia-phosphate composites can be hardened very quickly and hydrated even in low temperature, which can be used as an alternative of severe cold weather concrete in arctic regions. This study developed the magnesia-phosphate composites that can be used in severe cold regions and suggested an appropriate mixture design from the experimental results.

Field Measurement and Analysis of Post-Tensioned Prestressed Concrete Pavement Behavior under Tensioning (현장실험을 통한 포스트텐션드 프리스트레스트 콘크리트 포장의 긴장 시 거동분석)

  • Park, Hee-Beom;Kim, Seong-Min;Kim, Dong-Ho
    • International Journal of Highway Engineering
    • /
    • v.11 no.1
    • /
    • pp.247-256
    • /
    • 2009
  • This research was conducted to analyze the behavior of PTCP (Post-Tensioned prestressed Concrete Pavement) under tensioning by performing field tests when the experimental PTCP slab was being constructed. The displacements in the slab under the environmental loading and tensioning were measured using temperature measurement sensors and displacement transducers. Tensioning was performed three times and appropriateness of tensioning could be determined by investigating the relationship between temperature and displacement, behavior of transverse crack, and daily change in displacement. The results of this study showed that under the first tensioning at very early age, large displacements were observed only near the joints because of the friction between slab and underlying layer and concrete inelasticity. Under consecutive tensioning, displacements were clearly observed all over the slab, but still affected by the friction. In addition, appropriate tensioning ensured the one-slab behavior of the PTCP slab even though cracks existed.

  • PDF

Influence of Bubble Sheet Applying Methods on Temperature of Exposed Joint Rebar at Wall Surface of Load-Bearing Wall Structure Building During Winter (동절기 벽식구조 건축물 벽부분의 버블시트 포설방법 변화가 이음부 노출철근의 온도에 미치는 영향)

  • Han, Cheon-Goo;Lee, Jea-Hyeon;Kim, Min-Sang
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.2
    • /
    • pp.149-155
    • /
    • 2017
  • In this research, the surface covered curing method using the double-layered bubble sheet was evaluated. This double-layered bubble sheet has outstanding insulating performance with its low heat conductivity and high economic feasibility with its high durability. However, in the case of wall-typed building construction, the area of exposed rebar is curious on curing performance with the double-layered bubble sheet in spite of the double-layered bubble sheet showed favorable performance for slab. Therefore, in this research, regarding the actually constructed wall-typed apartment building, the most efficient curing method was suggested based on the evaluation of curing performance depending on temperature distribution depending on various location of covered or exposed rebar. As a result, the D method was determined as the most efficient curing method without any concern of early-age frost damage. However, by considering easiness of construction, the B method of covering the pieced double-layered bubble sheet on gap between rebars can be another option of desired result.

Analysis on the Heat Insulation Performance of Cold Weather Concrete according to Change of Laid Construction Conditions of Double Bubble Sheets (이중버블시트의 포설 시공조건 변화에 따른 한중 콘크리트의 단열보온 성능 분석)

  • Han, Cheon-Goo;Han, Min-Cheol;Baek, Dae-Hyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.5
    • /
    • pp.121-128
    • /
    • 2010
  • The present research examined heat insulation performance according to change of various laid construction conditions of double bubble sheet being used as material for heat insulation & curing construction of cold weather concrete, and its results are as follows. First, the change in a laid period of bubble sheet within 4 hours and the change in water content inside bubble sheet overall showed similar temperature history and maturity without a big difference in terms of the temperature history of concrete according to construction factors, but it could be confirmed that when a structure was thin or several bubble sheets are laid, requisites unfavorable for initial curing of concrete can occur if a lagger distance between sheets is generated. In terms of the compressive strength of concrete core specimens, it appeared that the initial compressive strength is declined when conditions unfavorable for concrete curing such as delay of a laid period of bubble sheets, induction of large distance between sheets, increase of water content inside bubble sheets and thinness of a structure of placing concrete, etc. were applied, but it appeared that as its age passes, the difference becomes small.

A Case Study on Cause Analysis for Longitudinal Crack of Duct Slab in Tunnel (터널 덕트슬래브의 종방향 균열에 대한 원인 분석 사례 연구)

  • Park, Sung Woo;Park, Seung Su;Hwang, In Baek;Cha, Chul Joon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.5
    • /
    • pp.19-28
    • /
    • 2012
  • In this study, cause of longitudinal crack which is found on duct slab of road tunnel is studied. In-depth investigation, such as visual inspection, non-destructive testing and geometrical surveying of duct slab, is carried out. In order to perform cause analysis, the investigated results are compared to the results of numerical analysis. Many factors, which cause longitudinal crack, are classified as constrained condition of the duct slab, location of the rebar, temperature, shrinkage and so on. According to the classified causes of longitudinal crack, numerical analysis is performed considering construction stage of the tunnel lining. Especially, in order to predict shrinkage stain due to discrepancy of curing date, ACI-209 model, KCI structural design code and other researcher's shrinkage test results are compared. The results show that shrinkage strain is one of the main factors causing longitudinal crack. Other investigated tunnels are classified along with the construction method of duct slab and patterns of cracks. As a result, improving ways to construct duct slab are suggested.

A Study on the Resistance to Sea Water and High Flowing Properties of Concrete Using Blended Low Heat Cement (혼합형 저발열 시멘트를 사용한 콘크리트의 초유동성 및 내해수성에 관한 연구)

  • 송용순;노재호;강석화
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.6
    • /
    • pp.281-289
    • /
    • 1998
  • This study has been performed to test the flowability and filling ability of high flowing concrete as well as distribution of aggregate and pore of core specimen, heat of hydration, compressive strength and core strength of concrete. In addition, the resistance to chloride ion penetration and chemical solutionof concrete was tested in order to evaluate the resistance to sea water of concrete and its application of high flowing concrete using blended low heat cement in the field of Seohae Grand Bridge. The properties of high flowing concrete with blended low heat cement were compared with ordinary 25-240-15 concrete using Type V cement. As the results of this study, the flowability and filling ability of high flowing concrete with blended low heat cement is satisfied without vibration. Though the cement content of high flowing concrete with blended low heat cement was 400kg/m$^2$, the rising temperature of it was relatively lower than that of the ordinary 25-240-15 concrete with Type V cement. Also, the compressive of high flowing concrete with blended low heat cement is similar to that of the ordinary 25-240-15 concrete with Type V cement.

A Proposal of Autogenous Deformation and Self-induced Restrained Stress Test Using Thermal Analysis Results to Predict Early-Age Cracks of Externally Restrained Concrete Members (외부구속 콘크리트 부재의 초기균열 예측을 위해 온도해석 결과를 이용한 자가변형 및 구속응력 측정 실험의 제안)

  • Byun, Jong-Kwan;Kang, Won Ho;Kang, Jeong-Kil;Bae, Seong-Jae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.1
    • /
    • pp.1-10
    • /
    • 2018
  • It is difficult to predict the early-age cracks of strain restrained concrete members due to environmentally sensitive parameters. A new method is proposed to predict the cracks by test of autogenous deformation and self-induced restrained stress of specimens which simulates early-age crack state by hydration heat of the'Wall-On-Foundation'members. For this purpose, thermal analysis of entire structure considering the environmental condition is performed at first, and the specimens are set up where hydration heat was electronically controlled according to the analysis results. By measuring free deformation and force to compensate the autogenous strain including relaxation, feasibility of cracks can be estimated. The proposed method can predict the occurrence of cracks better than the material test of the early age concrete which has large variance. The method of this study is particularly useful when it is used as a preliminary experiments to predict the crack more precisely before full-scale concrete placement in construction of large structures.

A Study on the Strength Properties of High-Strength concrete under Various curing conditions (각종 양생방법에 따른 고강도 콘크리트의 강도발현 특성에 관한 연구)

  • Cho, Hyun-Dae;Jaung, Jae-Dong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.965-968
    • /
    • 2008
  • The KS F 2403 method used on domestic sites for checking the compressive strength of a structure, sets the compressive strength of the concrete used in structural specimens as the compressive strength of testing specimens. Under this regulation, the curing method used for testing the specimens must be the standard ponding curing method (20$\pm$2$^{\circ}$C). However, because in-placed concrete is exposed to open air and cured under the seasonal temperature changes, the compressive strength of a real structure is different from the tested compressive strength. (Therefore,) This thesis first identifies the distinct characteristics of the strength development by applying the curing method listed under the KS and used for testing specimens on compressive strength tests; the atmospheric curing method, the sealed curing method, and the structural specimen core strength testing methods used for the in-sites quality checks including reckoning of the compressive strength of the structural specimens and form-demolding period; and the curing method suggested in this research, which sets the internal conditions of the structural specimens as the conditions of the applied curing method. Then, the thesis suggests the specimen curing method that most closely reenacts the compressive strength of the concrete used on the structural specimens

  • PDF

Exothermic Curing System with Hot Wire in Cold Weather (열선을 사용하는 동절기 발열양생 평가시스템 개발)

  • Lee, Tae-Gyu;Lee, Jin-Sun
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.1
    • /
    • pp.52-59
    • /
    • 2016
  • For almost of concrete structures by placing in cold weather, it is very important that the selection of curing method at early aged construction stage. The Exothermic curing method with hot wire and rapid hardening cement is used mostly to prevent the initial cracks and the strength decrease. Most of the construction sites, however, have not been applied to the optimal curing method caused by the simple approaches and the empirical judgements. Therefore, this paper has proposed a evaluation algorithm of the exothermic curing method for representing heating temperature, period, position of hot wire by analyzing the transient heat transfer solution. This has been implemented, moreover, using an object oriented programming language to develop structural analysis system taking account risk parameters. This system is composed of input module, database module, database store module, analysis module, and result generation module. Linkage interface between the central database and each of the related module is implemented by the visual c# concept. Graphic user interface and the relational database table are supported for user's convenience.

State-of-the-Art Research and Experimental Assessment on Fire-Resistance Properties of High Strength Concrete (고강도 콘크리트의 내화 특성에 관한 기존연구 고찰 및 실험적 연구)

  • Kim, Woo-Suk;Kang, Thomas H.K.;Kim, Wha-Jung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.28-39
    • /
    • 2014
  • This paper reviews past literatures relevant to fire-resistance properties of high strength concrete and investigates spalling mechanism of high strength concrete in fire. First, literatures were reviewed on spalling occurrence and fire-resistance methods. Second, a chemical change of concrete components in an elevated temperature was presented. Finally, the mechanism of the spalling occurrence and spalling resistance were examined in terms of hybrid fiber content. The focus of the experimental study as part of this research is to investigate the effects of fire on the variation of thermal properties of high strength concrete, which tends to be used in super tall buildings. This experimental study was devised to investigate the fire-resistance performance of high strength concrete containing hybrid fibers. A total of 48 test specimens were exposed to high temperature ranging from $100^{\circ}C$ to $700^{\circ}C$, including room temperature (${\sim}20^{\circ}C$). Test results provide valuable information regarding fire-resistance properties of strength concrete with 100 MPa or greater.