The Gravity Drainaged Underpass Design considering the Topography and the Ground Specific (지형 및 지반특성을 고려한 자연배수식 지하차도 설계사례)

  • An, Seok-Jun;Kim, Sun-Kon;Choi, Yong-Gue;Lee, Sang-Heon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.607-619
    • /
    • 2009
  • In case that there is not an influence of river influx because the foundation is a good rock and the mountain topography, we present the design case for the reasonable underpass foundation form, bearing capacity and drainage process considering the topography and the ground condition.

  • PDF

An Electrical Resistivity Survey for the Characterization of Alluvial Layers at Groundwater Artificial Recharge Sites (지하수 인공함양 지역 충적층 특성 평가를 위한 전기비저항탐사)

  • Won, Byeongho;Shin, Jehyun;Hwang, Seho;Hamm, Se-Yeong
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.3
    • /
    • pp.154-162
    • /
    • 2013
  • Vertical electrical sounding and 2D electrical resistivity survey were applied for evaluating the characteristics of alluvial layers at a groundwater artificial recharge site. The fine particles in alluvial layer, main target layer of groundwater artificial recharge, may cause clogging phenomena. In this case, electrical resistivity method is an effective technique to verify the spatial distribution of low-resistivity layers, such as saturated silts and clays. On the other hand, much attention should be paid to interpret the resistivity data in unconsolidated layers, because thick clayey overburden sometimes produces a masking effect on underlying interbedded resistive sands and gravels. Considering these points, we designed 35 points arranged in a grid form for vertical electrical sounding and 10 lines for 2D electrical resistivity survey, and concentrated our effort on enhancing the vertical and horizontal resolution of resistivity images. According to the results, 15 meters thick layers consisting of sands and gravels are located in 30 meters below ground. And the spatial distribution of silts and clays are mapped, which may cause clogging. Consequently, this approach can contribute to design and determine the location and depth of injection and observation wells for groundwater artificial recharge.

Bond Characteristics of Scale According to the Drainage Pipe's Material in Tunnel (터널 배수공의 재질에 따른 스케일 부착 특성에 관한 연구)

  • Chu, Ickchan;Nam, Seunghyuk;Baek, Seungin;Jung, Hyuksang;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.11
    • /
    • pp.51-57
    • /
    • 2011
  • The calcium hydroxide($Ca(OH)_{2}$) which is flowed into the deteriorated tunnel by groundwater is reacted with carbon dioxide($CO_{2}$) and the vehicle's exhaust gas ($SO_{3}$). So its by-products are precipitated at the drainage pipe and these cause the drainage clogging. Most by-products are composed of $CaCO_{3}$ with calcite from a chemical experiment. The purpose of this study is mainly focused on comparison of attachment on each material of drainage pipe (teflon-coated steel pipe, silicon-Oil coated pipe, acrylic pipe and PVC pipe). The test was progressed to disembogue the CaO aqueous solution and tunnel outflow into each of the pipes. The experimental results show that the most produced scale pipe is PVC material and the followings are Acrylic pipe, Silicon-Oil coating pipe and Teflon coating pipe. But the long-term test results showed that teflon-coated steel pipe had a problem with durability because soil which was contained in the tunnel outflow occurred detachment of coating and corrosion of the steel pipe.

Previous road type GI/LID demonstration test facility design and construction (투수 도로형 GI/LID 실증실험시설 설계 및 구축)

  • Park, Jae Rock;Kim, Gun;Lee, Jae Hyeok;Shin, Hyun Suk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.171-171
    • /
    • 2016
  • 최근 도시화가 진행되면서 지표의 불투수화가 급격하게 진행되고 강우의 지표면 유출량이 급격하게 증가하여, 강수 시 첨두유출 시간이 감소하고 단기간 집중유출이 증대되어 폭우로 인한 도시 홍수등이 발생하고 있다. 이러한 현상에 효과적으로 적응하기 위해 환경적으로 지속가능한 도시 개발을 위한 그린인프라(GI, Green Infrastructure) 및 저영향개발기법(LID, Low Impact Developpment)이 국내에 도입되고 있다. 하지만 아직까지 투수성 포장의 물순환 성능 평가 및 설계 방법에 대한 기준이 명확하지 않으며, 많은 경우 투수성 포장의 적용은 유출저감효과에 대한 정량적 해석 없이 적용되고 있는 실정이다. 이에 본 연구에서는 경남 양산시 부산대학교 제 2 캠퍼스에 있는 "한국형 GI&LID 실증실험단지"에 투수 도로형 실증실험시설을 구축하였다. 실험 시설은 불투수 아스팔트와 투수 아스팔트, 불투수 콘크리트와 투수 콘크리트 비교실험 할 수 있으며 도로표면 유출수 및 침투수에 대한 유량 및 수질 측정 모니터링을 통해 침투효과 및 특성을 분석할 수 있으며 차후 투수성 포장의 클로깅 현상으로 인한 투수성능의 감소 등 여러 가지 실험을 할 수 있을 것이다.

  • PDF

The Study of Appropriate Mixture Ratio and Replacement Ratio of Bottom Ash Mixture Compaction Pile in Soft Ground (연약지반에서 저회혼합다짐말뚝의 적정 혼합비 및 치환율 산정에 관한 연구)

  • Do, Jong Nam;Chu, Ick Chan;Chae, Hwi Young;Chun, Byung Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.4C
    • /
    • pp.139-147
    • /
    • 2012
  • In this study, various laboratory tests using bottom ash, which has similar engineering properties with sand, were conducted in order to solve the problem of clogging in granular compaction pile and to address sand supply and demand. In particular, testing was performed to help reduce clogging and minimize voids in a crushed stone compaction pile constructed in soft ground. Based on compaction tests and large diameter direct shear tests, an optimum mixing ratio was determined to be 80:20 (crushed stone to bottom ash) because an 80:20 mixing ratio showed the highest shear strength. Test results showed that as the bottom ash content increased above 20%, internal friction angle decreased. Another test method showed freezing and thawing had little effect when the replacement ratio was over 40%. Therefore, bottom ash mixed compaction piles in soft ground are most economical at a 40% replacement ratio.

A Study on Utilization of Recycled Aggregates as Lateral Drain for Soft Ground Improvemnet (연약지반 개량을 위한 수평배수층 재료로 순환골재의 적용 방안에 대한 연구)

  • Lee, Jong-Yoon;Chun, Hae-Pyo;Jeong, Woo-Chul;Lim, Hae-Sic
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.10
    • /
    • pp.5-15
    • /
    • 2008
  • The purpose of this study is to examine the validity of recycled aggregates (RAs) as a substitute for Sand-Mat material for soft ground improvement in the housing site development. To evaluate the possibility of RAs as a substitute for sand mat material, first of all, the criteria and regulations related with the quality of lateral drain layer were collected and checked. Secondly, both of the properties of RAs were compared with the properties of natural sand for the lateral drain layer. The material properties related to coefficient of permeability, pressure at-rest state and so on satisfied most standards. On the basis of the test results, RAs were used to the construction site as lateral drain layer. Accordingly, if the quality of RAs can be managed well, the application of these RAs as lateral drain layer to replace natural sand was highly effective. Also, based on cost analysis of two materials, RAs are proved to be very competitive.

Study on the Specification for the Filter of the PBD (국내 연약지반특성을 고려한 연직배수재 필터 시방기준에 대한 기초연구)

  • Ko, Young-Hi;Kwon, Soo-Young;Lee, Jong-Sung;Hyun, Seung-Hoon;Lee, Joo-Gong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1102-1107
    • /
    • 2005
  • In this study, a specification for the filter system of plastic board drain using in korea. When PBDs was installed in the soft ground, bridging, blocking, blinding and clogging phenomena could be appeared near the PBD. Especially, clogging phenomena near the filter of PBD is very important factor to determine the life span of the vertical drainage system. Therefore, in this study, we proposed the specification on the filter of PBD considering the size of soil particle. To verify the proposed specification, model tests were conducted by using filter seepage tester. From the model test, newly proposed specification which considered the size of soil particle maintained the ability of seepage of the filter system of PBD.

  • PDF

Numerical Study of Settlement Reduction Ratio for the Bottom Ash Mixture Compaction Pile (수치해석적 방법에 의한 저회혼합다짐말뚝의 침하저감비에 관한 연구)

  • Chu, Ickchan;Kim, Gooyoung;Do, Jongnam;Cho, Hyunsoo;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.3
    • /
    • pp.53-58
    • /
    • 2012
  • In general, sand compaction pile(SCP) method and gravel compaction pile(GCP) method have been mainly used to reinforce soft soils such as soft clay or loose sandy ground. But the sand compaction pile method has problems such as lack of sand supply and destroying the nature while collecting sand, the gravel compaction pile method has a problem such as decreased permeability of the drainage material due to clogging. Recently, the study to replace sand with bottom ash which has similar engineering properties with sand is in active. As a fundamental research on bottom ash mixture compaction pile utilizing bottom ash, its behavioral characteristics depending on granular materials and replacement ratio has been simulated numerically. In particular, Settlement Reduction Ratio(SRR) according to the distance from the center of pile was calculated. The main findings were as follows. Change values of Mixture Compaction Pile's SRR according to granular materials showed similar patterns and stiffness of the composite soil is increased depending on the replacement ratio so SRR showed decreased patterns. Especially, when the replacement ratio is in 20~40%, it increase significantly. When the replacement ratio is over 40%, it increase slowly. When considering the economics, 30~40% replacement ratio is appropriate.

Stress Concentration Ratio of GCP Depending on the Mixing Ratio of Crushed Stone and Sand (GCP의 쇄석과 모래의 배합비 별 응력분담비)

  • Na, Seung-Ju;Kim, Min-Seok;Park, Kyung-Ho;Kim, Daehyeon
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.9
    • /
    • pp.37-50
    • /
    • 2016
  • Gravel compaction pile (GCP) is widely used as it increases the bearing capacity of soft ground and reduces the consolidation settlement. Stress concentration ratio for GCP design is dependent on the area replacement, surcharge pressure and depth. However, a range of stress concentration ratio obtained through field, laboratory experiments and numerical analysis is large. Little study has been done on the stress concentration ratio for the mixing ratio of gravel and sand. The main objective of the study is to evaluate the stress concentration ratio for both area replacement ratio and mixing ratio through literature review and numerical analysis. Numerical analysis using the finite element program ABAQUS 6.12-4 has been performed for the composite ground with GCP. The excess pore water pressure and stress concentration ratio of composite ground have been analyzed for both the area replacement ratio and the mixing ratio. Based on the previous research results, a range of stress concentration ratio obtained from the field tests, laboratory tests, numerical analysis on the GCP studies is found to be 1.7-3.2, 2.0-7.5 and 2.0-6.5, respectively. Based on the numerical analysis results, as the area replacement ratio increases, the stress concentration ratio increases up to 30% and then decreases at 40%. Also, the stress concentration ratio tends to increase up to 70:30 and then to decrease after 60:40.